Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online, Page 1 of 5 BCIS Home I Log In I User Registration i Hot Topics I submit surcharge ( Stabs ®Facts Publications I FBC Staff BCIS Site Map Llnks ( search db ([�y)90 Product Approval lriv USER: Public User t " orm PmduR Aooroval Menu > ProduR or Aoolication search > Aoolicabon tist> Application Detail - FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Certification Agency Validated By Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL5678-R3 Affirmation 2014 Approved Clopay Building Products Company 8585 Duke Blvd. Mason, OH 45040 (513) 770-6062 mwesterfjeld@clopay.com Scott Hamilton shamilton@clopay.com Exterior Doors Sectional Exterior Door Assemblies Certification Mark or Listing SCANNED BY St. Lucie Comb, Intertek Testing Services NA, Inc. Gary Pfuehler L Validation Checklist - Hardcopy Received Standard ANSI/DASMA 108 ASTM E330 Year 2002 2002 Wit affirm that there are no changes in the new Florida Building Code which affect my product(s) and my products) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity ;Yes ONO ON/A Product Approval Method Date Submitted Method 1 Option A 02/26/2015 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsTDgv2o9Yg3... 1 /11 /2017 Florida Building Code Online Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page = a Page 2 of 5 02/26/2015 F 1 � 03/07/2015 d 10 Page t/20 0 FL # Model, Number or Name Description 698.21 10-22 C-PAN-SE448: 524, Ribbed Steel (min. 24 ga.) WINDCODE@ WS Sectional Door, 524V, 524S, 520, 520S, 224, 224S, 16'4" to 222" wide C4ST C4SV, C4SS, COST, COSS Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5678 R3 C CAC Letter with proof of contract and proof of inspection.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A FL5678 R3 C CAC WS C Listing Intertek pdF Design Pressure: +30 PSF/-30 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL5678 R3 11 103319-Rev03.Ddf windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 5678.22 22 W5-12 C-AL-1F499: 902, 903, Service Station WINDCODE@ W5 Sectional Door, up to 122" C2AL, C3AL wide Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5678 R3 C CAC Letter with Proof of contract and Proof of inspection.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A FL5678 R3 C CAC WS C Listing Intertek.odf Design Pressure: +32 PSF/-32 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL5678 R3 11 103275-RevOS.Ddf windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the Impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 5678.23 23 W5-16 C-AL-1F499: 902, 903, Service Station WINDCODE@ WS Sectional Door, 12'4" to C2AL, C3AL 162" wide (c-channel) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5678 R3 C CAC Letter with Proof of contract and proof of inspection.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A FL5678 R3 C CAC W5 C Listing Intertek.Pdf Design Pressure: +32 PSF/-32 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available For this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL5678 R3 11 103294-RevO2.odr windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the Impact resistant requirement for windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 5678.24 24 W5-16 C-AL-SF499: 902, 903, Service Station WINDCODEO W5 Sectional Door, 12'4" to C2AL, C3AL 16'2" wide (AL angle) Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5678 R3 C CAC Letter with proof of contract and proof of inspection.Pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A FL5678 R3 C CAC W5 C Listing Intertek odf Design Pressure: +30 PSF/-30 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 meets the wind load requirements of the building code but Installation Instructions DOES NOT meet the impact resistant requirement for FL5678 R3 II 103295-RevO5.pdf windborne debris regions. The product without glazing DOES Verified By: Intertek Testing Services NA, Inc. comply with the impact resistant requirement For windborne Created by Independent Third Party: debris regions (ref 1609.1.4 FBC). Evaluation Reports Created by Independent Third Party: 5678.25 25 W5-20 C-AL-1F499: 902, 903, Service Station WINDCODE@ W5 Sectional Door, 16'4" to C2AL, C3AL 20'2" wide Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL5678 R3 C CAC Letter with r f contract and Proof of insoection.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A FL5678 R3 C CAC W5 C Listing Intertek.odf Design Pressure: +30 PSF/-30 PSF Quality Assurance Contract Expiration Date Other: The OPTIONAL glazing available for this product 05/21/2028 http://www.floridabuilding.org/pr/Pr_app dtl.aspx?paratn=wGE VXQwtDgsTDgv2o9Yg3... 1 / I 1 /2017 GARAGE DOOR DESIGN PRESSlMW TABLE t60a.3.1 WIND SPEED CONYEHSIO1 S%k' V,e '10D 110 120 130 140` '150 .1 160 170 180 190 200 Vim' 7B 85 93' 101 108 116 124 132 139 147 155" For SL• lmilepahour=0.44 m1s. a Ltnearintespolstlon Ispamitted., b.lf tau uinsl design wind speedapplicable'mmedrods'gzcfflediaEmp9ow l tbmugb 5 of Section 1609.1:7. e. V,e=elti4oatcdeaign ivied speak detennioed fiomFgmes ]609A, I(A9B, or 1609C... A MEAN ROOF HE16HT OF. 30 FEET ULTIMATE DESIGN WIND SPEED (VjDE'TERMINED INACCORCANCE WITH SECT10N 1609.3 (MPH -a SECOND OUST) W(dtl1 fah HelOht (�h .1o0 MPH ' 110MPH 120NPH ISOMPH 140MM Isoilpfl 1sampit litimm tail A1PH.: �tt3umm 200 MPH Reol Ang19.0-f00ogroee.. _ .. , 8 8� 1 87-9.8 1 105-119 125-142- 14Z-16.6 17.1-19$. 99.6-222. 273=251 23"1-78S =-31.9 11.4-355 .349-39A 10 .10 " 9i-9A 1D2-11.4 1 )2.1-13.6 I 14.2-I6.0 16.5-185 '109-212 215-74.2 24.3-273 -773-30.6 30d-3' 1 317-37.8 14: 14 6.0-8.9 9.7-109" 11.5-129 ,135-ISAI I J5.7-17A I 18.0-2D.o. 2&5-.22.8 211-25.7 .239-28.8 28.9-32.1 32A-35.6 .Root Anslo,>tO a�Bmtn 9 7' -9.6- 119 IIA-12.9 13.7-133 9&1-192 1 783=209 213-24.1 24.3-275 1 27.6-312 1 30:6-34.6 1 34.2-.3&6 3g0-43.0 16 '7 "92-103 109-122 13.1-14.6. 153=172 17.7-19"7 7DA-227� .._.c1 233=26.0 2E.4=29A '293-326' 327-30 '36A-4DA 781APH 85aAPR 93M% ]OI MPH 109MPIi I 116MPH . 17AMPH I 132htiQ 139WH I 147MPH I IWMPH P"Sh:Ifoot.S 4.8ma4lm0epahm-1,609Wkf 1paI='47.BBNlms. NomioaIDesbw WaSPwdYVead)coavcsWfn 1 plus and minus signs slgniP, 4. Negative pressisus A S. Table vilaes include the 0:6 TABLE1609.7)ADJUSTMENTFACTO Pon BUILDING DEAN ROOFHEIGHT(roo0 _ SUflE' .. eItZ53 n 15 - 1.00'4A7 ' 25 ' 1.00,F 2.61 30. - 1.00' ,L66 35.1.05 1.70 40..._ - - - 1.09 . -;1.74 45 1:12;1.78 50 1.16. im 1.81 55 1.19 ;1.59' 1.84 60 - - 122 1.62: 1.87 --' Irate Design Wu)d Speed Per SeWnn.16093.1 apolnted, od awlse use the load a«odated with the Iowa effeedya area. mcenteoeffideatin Table 2609.7(2) surf nuns. R612.4.1,Garage door labeling. Gatagg doors sball;be labeled `with a permanent label provided by,'the garep dots maatdaCh=.,The label Shall identify "the garage door maoafaclurer, the gauge door modevaeries number, the positive and negative design pressum rating indicate impact_ rated if applicable, the installation hudroction drewiag reference number. the Florida 13oduct Approval or Mami-Dade Product Approval number if applicable, and the applicable'test standards, The'required garage door components for an approved gamp door amrablymay be indicated using'a checklist form on the label. if a checklist format is used on the label ,the door installer of the garages door matiitfecturer shall mask die selected components an the checklist that are required. to assemble on approved garage door System. '!he installation instructions shall be provided and available on the job site. FLORIDA-BUILDINGCODE-DUIIDING, 6th EDITION,(2014) onc, E v";'M P Y