St. Lucie Countv
FL1654-R19
Revision
2014
Approved
0
y -
lk
� , I �
K
Now uwr'.bem, ,DBPR.bYr1eN)ee obxrICTbeM4
POLYGLASS USA
150 Lyon Drive
Fernley, NV 89408
(570) 384-1230 Ext 242
jakins@polyglass.com
) jFj{j d t t
i HESE PLANS AND ALL PROPOSED VV09 h
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO { I
COMPLY( WITH ALLAPPLICABLE CODES.`
CONCEUD FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBUN OF THE
CONTRACTOR OF RECORD
Authorized Signature James Akins
jakins@polyglass.com
ST. LVCIE COU1 _ _ RUILD?NC DIVISION
Technical Representative Steve wadding RENTER ED FOR L`PLIANCE
Address/Phone/Email 150 Lyon Drive REVILRrE1),Y$
Fernley, NV 98408 DATE
(602) 363-7139PLANS AND PERMIT MUST RE KEPT ON JOE
stevew@polyglass.com OR NO INSPECTION WILL ME MADE.
Quality Assurance Representative James Akins
Address/Phone/Email 555 Oakrldge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800) 894-4563
jakins@polyglass.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method Evaluation Report from a Florida Registered Architect or a Ucensed
Florida Professional Engineer
Ll Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nleminen
the Evaluation Report
Florida Ucense
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
PE-59166
UL U-C
10/06/2018
John W. Knezevich, PE
Z Validation Checklist - Hardcopy Received
Standard
Year
ASTM D6162
2000
ASTM D6163
2000
ASTM D6164
2005
ASTM D6222
2008
ASTM D6509
2009
FM 4470
1992
https:tMww.fltuidabdlrGng.orglpr/pr app dtl.aspx7param=wGEVXQwtDgvgqu2w%2bnFgUPv2pw6pKxAh16SHQFy2kzdQRng46uFTrw%3d%3d 112
99=W# F
Florida Building Code Online
FM 4474 2004
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 04/18/2016
Date Validated 04/19/2016
Date Pending FBC Approval 04/20/2016
Date Approved 06/08/2016
Summary of Products
I
FL 7t
Model, Number or Name
Description
1654.1
Polyglass SBS and APP Modified
SBS and APP modified bitumen roof systems
Bitumen Roof Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL1654 R19 IT 2016 04 FINAL AlR POLYGLASS MODBrr FL 54
R19.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure In this application
Evaluation Reports
relates to one particular assembly over concrete
FL1654 R19 AE 2016 04 FINAL ER POLYGLASS MODBI7
R39.odf
deck. Refer to the ER Appendix for other systems and
deck types. 2.) Refer to ER, Section 5 for other Limits
Created by Independent Third Party: Yes
of Use.
Back Next
Conte s :: 2001 Blair Stone Road, Tallahassee F 32399 Phone: 850-487-1824
The state of Florida is an AA/E employer. Coovricht 2007-2013 State of Florida.:: Pdwu v Statement :: Accessibility statement :: Refund Statement
Under Florida law, email addresses are public records. If you do net want your e-mail adder released in response to a public -records request, do not send electmNc
mail to this entity. Instead, contact the office by phone or by treditional mail. If you have any questions, please mnGd 850.487.1395. 4'ursuant to Section
455.275(1), Florida Statutes, effective Odober 1, 2012, licensees licensed under Chapter 455, F.S. must povide the Department with an email address if they have
one. The entails provided may be used for ofndal cammuniration with the limmee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address wNN can be made avallable to the public To determine if you are a licensee under Chapter
455, F.S., please dids hIi
product Approval Accepts:
®® a
sccu rilYAl hrnlcs
htWslA r .floridabUlding.orgfpr/pr app O.aspx7param=wGEVXQwtDgvgqu2%2bnFgUPv2pw6pKxAhf6SHQFy2kzdQRrg46UF7fw%3d%3d 212
�! TRWITY ERD
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPUFr RESISTANCE
Table Deck Application Type Description Page
IA Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5
18-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9
1B-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-11
1C Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 12
1D Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 13-14
1E Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 15-16
1F-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 17-19
1F-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 20-22
16 Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 22 l
2A Steel or Conc. New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 23
2B Steel or Conc. New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 24-25
2C Steel or Conc. New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 26-27
3A Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 28-32
3B
Concrete New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
32
4A
LWIC New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
33-34
4B
LWIC New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
34
4C
LWIC New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
35-37
SA
CWF New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
38
5B
CWF New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
39
SC
CWF New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
40
51)
CWF New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
40
SE
CWF New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
40
6A
Gypsum Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
41-42
6B
Gypsum Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
42
6C
Gypsum Reroof (Tear -Oft) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
42
61)
Gypsum Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
42
7A
Various Recover
A-1
Bonded Insulation, Bonded Roof Cover
43-45
7B
Various Recover
F
Non -Insulated, Bonded Base Sheet, Bonded Roof Cover
45
The following notes apply to the systems outlined herein:
1.
The roof system evaluation herein pertains to above -deck roof components.
Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the AHI.
Load resistance of the
roof deck shall be documented through proper codified and/or FBC Approval
documentation.
2.
Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢ Wood: Minimum 0.75-Inch penetration.
➢Steel: Minimum 0.75-Inch penetration and engage the top flute
ofthesteel deck.
➢ Concrete: Minimum 1-Inch embedment into pilot hole in accordance with fastener manufacturers published Installation Instructions.
3.
Unless otherwise noted, insulation may be any one layer or combination
of polyisocyanurate,
polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA
requirements of F.A.C. Rule 61G20-3 and Is documented as meeting FBC 1505.1 and, forfoam plastic, FBC Chapter 26, when Installed with the roof cover.
Exterior Research and Design, U.C. d/b/a Trinity) ERD
Evaluation Report P9290.02.08-R37 for FL3654-R39
Certificate of Authorization 99503
Revision 17:04/18/2016
Prepared by: Robert Nleminen, PE-59166
Appendix 1, Page 1 of 45
NTINITYIERD
4. Minimum 200 psi, minimum 2-Inch thick lightweight Insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base
sheet fasteners are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the AHI. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
S. Unless otherwise noted, Insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted In the manufacturer's published Instructions.
➢ Hot asphalt (HA): Full coverage at 25-30 Ibs/square.
➢ Dow Insta-Stik Roofing Adhesive (D-IS): Continuous 0.75 to 1-Inch wide ribbons, 12-Inch o.c.
➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-Inch wide ribbons, 12-Inch o.c.
D OMG OlyBond 500 (OB500): Continuous 0.75 to 1-Inch wide ribbons, 12-Inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where 01yBond 500 Is
referenced.
D OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
D ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-Inch wide ribbons, 12-Inch o.c.
D Note: When multiple layers(s) of insulation and/or coverboard are Installed In ribbon -applied adhesive, boardjoints shall be staggered.
D Note: The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the specified ribbons spacing.
6. Unless otherwise noted, all Insulations are Rat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'Increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material listed In the table:
➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick)
➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3)
D OMG OlyBond 500(OB500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+GL)
D OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3)
D OMG OlyBond 500 (013500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II)
➢ ICP Adhesives & Sealants CR-20: MDP -117.5 psf (Min. 1.0-Inch thick)
7. Bonded polyisocyanurate insulation boards shall be maximum 4 x4 ft.
8. For mechanically attached components or partially bonded Insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure crlteria. Commonly used methods are RAS 117 and FM LPDS 1-29.
Assemblies marked with an asterisk• carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPD51-29 for Zone 2/3 enhancements.
9. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted.
10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be In accordance with TAS 105 orANSI/SPRI FX-1.
11. For existing substrates Ina bonded recover Installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of
resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing In accordance with ASTM E907, FM LPD51-52, ANSI/SPRI IA-1 or TA5124.
12. For Recover Applications using System Type D, the Insulation is optional; however, the existing roof system shall be suitable for a recover application.
13. LWIC shall be cast In accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck
construction and limitations. For systems where specific LWIC Is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness Is 2-Inches. For LWIC over structural concrete,
reference is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Design, LLC, d/b/a Trinity] ERD Evaluation Report P9290.02.08-R37 for FL1654-R19
Certlficate of Authorization #9503 Revision 17: 04/18/2016
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 2 of 45
�I I KINITY ERD
14. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
TABLE 1:'.POLYGLAss ROOF COVERS '
Reference
Layer
Material
Application
BP -AA
Base Ply
One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Tye II
Hot Asphalt at 20-40
(Base and Ply sheets, Asphalt-
Ply
One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or A
Ibs/square
Applied)
Note.
Asphalt -applied sheets or Insulation shall not be applied to poly -film surfaced membranes.
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Polyglass HT Base 650
PG350 at 1.5-2.0
SBS-CAS
Cap
Elastoflex VG, ElastoRex VG FR, Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR, Polyfresko G
gal/square
SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6
Polyplus 35 at 1.5-2.0
SBS-CA2
Cap
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshleld TS-G FR, Polyfresko G
gal/square
SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply or Ply
One or more plies Etastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex 56, Polyglass
SBS-AA
Asphalt
Cap
HT Base 650
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield TS-G, Elastoshield TS-G FR,
Hot Asphalt at 20-40
Ibs/square
(SBS, -Applied)
Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Note:
Asphalt-appliedsheets or Insulation shall not be applied to poly -film surfaced membranes.
Base Ply or Ply
One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Polyglass HT Base 650
SBS-TA
(SBS, Torch -Applied)
Cap
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, ElastoRex S6 G, Elastoflex 56 G FR, Elastoshleld TS-G, Elastoshield TS-G FR,
Torch -Applied
Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed)
Base Ply
One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR
SBS-SA
Cap
Elastoflex SA P, Elastoflex SA P FR, Polyreflect
Self
(SBS, Self -Adhering)
Unlessotherwise noted, permissible membrane substratesfor5B5-SA arellmfted to the SBS-SA Base Ply options herein,
-Adhering
Note:
Elastobase (poly/sand) or Elastobase (paty/poly).
APP-TA
Base Ply or Ply
One or more plies Polyglass APP Base, Polyflex, Polybond
(APP, Torch -Applied)
Cap
Polyflex, Polyflex G, Polyflex G FR, Pol bond, Pol hand G. Polyfresko G, Polyfresko G FR
Torch -Applied
Cap
I Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool
APP SA
(APP, Self -Adhering)
Note:
Unless otherwise noted,permissible membrane substrotesforAPP-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
Elastobase (poly/sand) or Elastobase (poly/poly).
15. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance.
associated with coating usage.
D PG200 Non Flbered Roof Coating;
D PG300 Fibered Roof Coating;
➢ PG600 Non-Fibered Aluminum Roof Coating;
➢ PG650 Fibered Aluminum Roof Coating;
➢ PG700 High Quality Elastomeric Roof Coating or KM Acryl 25;
D PG700QS (Quick Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (for granule -surfaced APP or SBS only);
➢ PG800 Asphalt Emulsion Roof Coating;
➢ Polyplus 60 Premium Nan-Fibered Aluminum Roof Coating;
➢ Polyplus 65 Premium Fibered Aluminum Roof Coating;
➢ Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15;
D Polybrite 70Q5 (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (for granule -surfaced APP or SBS only);
➢ Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
Exterior Research and Design, U.C. d/b/a TrinitylERD
Certificate of Authorhation R9503
Prepared by: Robert Nieminen, PE-59166
Refer to current Roofing Materials Directory for fire ratings
Evaluation Report P9290.02.08-1117 for FL1654-R19
Revision 17: 04/18/2016
Appendix 1, Page 3 of 45
\1 1 KINITY ERD
16. The following represent priming requirements for gypsum -based coverboards:
➢ Dens Deck and Dens Deck Prime shall be field -primed with PG100 prior to self -adhering or torch -applied membrane application. No priming is required for hot -asphalt membrane applications.
➢ SECU ROCK Gypsum -Fiber Roof Board does not require field priming for any membrane application.
17. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those In Table 3A
applies:
VAPOR BARRIER OPTIONS; SMUCTURAL CONCRETE DECRI ADHERED IMUTAMON PER T"U 3A
Option p
Primer
Vapor Barrier
Insulation Adhesive
MDP (psf)
Type
Attach
1
PG100
Elastoflex SA V Plus
Self -Adhering
Inta-Stik or CR-20, 12-inch o.c.
-60.0
2
PG100
Polyglass APP Base
Torch -applied
Inta-Stik or CR-20, 12-inch o.c.
-75.0
3
PG100
ElastoBex SA P
Self -Adhering
Insta-Stik, 12-Inch o.c.
-75.0
4
PG100
Elastoflex SA P
Self -Adhering
Millennium One Step Foamable Adhesive, 12-Inch o.c.
-157.5
5
PG100
Elastoflex SA P
Self -Adhering
CR-20, 12-inch o.c.
-270.0
18. "MDP" = Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, I.I.C. d/b/a TrinitylERD Evaluation Report P9290.02.08-R37 for FL1654-R39
Certificate of Authorization R9503 Revision 17: 04/18/2016
Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 4 of 45
�I I KINITY ERD
TABLE3A: CONCRETE DECKS —NEW CONSTRUCTION OR REROOF(TEAR-OFF)
SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER
NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17
System
Deck
Base Insulation layer
Top Insulation Layer
Roof Cover (See Table 1)
MOP
No.
(See Note ll
Primer
Type
Attach
Type
Attach
Base Ply
Ply
Cap
(psi
(Optional if using AA Basel
C-67
Concrete
PGS00
Min. 0.25-inch Dens Deck Prime
Hot
None
N/A
(Optional If using AA
BP -AA, SBS-AA, SBS-TA or
SBS-ATA A, SBS-TA,
-510,0
asphalt
Ply) BP -AA, SBS-AA
APP
APP-TA
Cot APPDED BASE:'
Min. 0.25-Inch Dens Deck
C-68
Concrete
None
Min. 1.5-inch ACFDam ll or H-Shield
03500
Primeor SECUROCK
OBSOO
SBS-CAS, SBS-CA2
None
SBS-CA1, SBS-
-90.0
Gypsum -Fiber Roof Board
CA2
Min. 0.25-Inch Dens Deck
C-69
Concrete
None
ACFoam III,
Minld,
CR-20
Prime or SECUROCK
CR-20
SBS-CAI, SRS-CA2
None
SBS-CA3, SBS-
-90.0
HInch
r ISO95ENRGYGL
Shield, H-Shield CG, Multi -Max FA3 or ISO 95+GL
Multi -Max
Gypsum -Fiber Roof Board
CA2
TABLE 3B: CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF)
SYSTEM TYPE F: NON -INSULATED, BONDED BASE SHEET, BONDED ROOF COVER
Deck
i Roof Cover (See Table 1)
System No.
(See Note 1)
Primer
MOP (psf)
Base Ply
Ply
Cap
C-70
Concrete
PG100
SBS-SA
(Optional) SBS-SA, SBS-TA, APP-TA
SBS-SA, APP-SA, SBS-TA, APP-TA
-315.0
GI
t
PE
odyfe ,SA 8a
(p u. .'.P:T
APP>F
.35.0
C-72
Concrete
PG300
BP -AA (Optional if using asphalt applied Ply)
(Optional if using asphalt applied Base) BP -AA, SBS-
SBS-AA, SBS-TA, APP-TA
-622.5
AA, SBS-TA or APP-TA
Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report P9290.02.08-1137 for FL7654-R39
Certificate of Authorization R9503 Revision 17:04/18/2016
Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page 32 of 45