Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL9272016 '! Florida Building Code Online - Business & Professional - — NMI 116 Regulation r BM Home I Lag M I User Regisbatlon I Ha T0p16 submit Sun'Jalge I Slats a F.M Publlrabons FBC SUff BCLS Site Map Llnks Seartli a SGApNNED db'pr Product Approval BY Pu USER: blic User Si. Lucie COUntV L PmduRAvomvalMenu>PmtluRorAoalitaHonSearcb>gvvllatlonList >ApplicationDetan FL # F1-1654-1119 Application Type Revision 1rtlfftr�a46CU FASTENERS RATTANMEM Code Version 2014 Application Status Approved ARE THE iQROPOONSU C , v TmE Comments ^rr r rnY IY11 VP fIGW(1y Archived D 1 Product Manufacturer POLYGLASS USA THESE PLANS AND ALL PROPOSED WORK Address/Phone/Email elen18Fr y NV 9408 ARE SUBJECT TO ANY CORRECTIONS 384-12Ext 242 jakf REQUIRED BY FIELD INSPECTORS THAT jakins@polyglass.com com iNAY`NE,tCESIARV•IN QRDER-TO Authorized Signature James Akins -� NIPLY_VNITH ALL APPLICABLE CODES: jakins@polyglass.com Technical Representative Steve Wadding Address/Phone/Email 150 Lyon Drive Fernley, NV 98408 ST. UCTE COIJ� R nrvG nn7SION (602) 363-7139 ti1Ai *CE stevew@polyglass.com REVIEWED FOR C -p iREVIEWED Y Quality Assurance Representative James Akins DATE r Address/Phone/Email 555 Oakridge Road PLANS AND PERMIT MUST AE KEPT ON JO_ Humboldt Industrial Pkwy OR NO INSPECTION WILL BE MERE, Hazleton, PA 18201 (800) 894-4563 jakins@polyglass.com Category Roofing Subcategory Modified Bitumen Roof System Compliance Method Evaluation Report from a Florida Registered Architect or a Ucensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Robert Nieminen the Evaluation Report Florida Ucense PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/06/2018 Validated By John W. Knezevich, PE OO Validation Checklist- Hardcopy Received Certificate of Independence F1,1654 R19 COI 2b16 01 COI Nieminen.odf Referenced Standard and Year (of Standard) Standard Year ASTM D6162 2000 ASTM D6163 2000 ASTM D6164 2005 ASTM D6222 2008 ASTM D6509 2009 FM 4470 1992 https:twww.floridabLilding.orgfpdpr app dU.aspx?paam=wGEVXQwtDpwplPw%2bnFgUPv2pw6pKxAhfBSHQFy2kzdQRng46uF7Tw%3da/o3d 1/2 9W12016 Florida Building Code Online FM 4474 2004 Equivalence of Product Standards Certified By Sections from Lite Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products �—I Method 1 Option D 04/18/2016 04/19/2016 04/20/2016 06/08/2016 FL # Model, Number or Name Description 1654.1 Polyglass SBS and APP Modified SBS and APP modified bitumen roof systems Bitumen Roof Systems Limits of Use Installation Instructions Approved for use in HVHZ: No FL1654 R19 II 2016 04 FINAL Al ER POLYGLASS MODBIT FL1654- R19.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other. 1.) The design pressure in this application Evaluation Reports relates to one particular assembly over concrete FL1654 R19 AE 2,016 04 FINAL ER POLYGLASS MODBIT FL1654- R19.odf deck. Refer to the ER Appendix for other systems and deck types. 2.) Refer to ER, Section 5 for other Limits Created by Independent Third Party: Yes of Use. Back Next Canted Us :: 2WI 91a1r Stone Read. Tallahassee M 32399 Phone: 850-487-1824 The State of Florida is an AA/H employer. Loovrinht 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addmsses are public recoNs. If you do not want your e-mail addnaa released In response to a publlr records request, do not send eleamnic mall to this entity. Instead, contact the office by phone or by tradlUoral mail. If you have any questions, please contact 850.487.1395. [Pursuant to Section 455.275(1), Florida Statutes, effective OQaber 1, 20I2, licensees llansed under Chapter 455, F.S. moat provide the Department with an email addreoi If they have one. The entails provided may be used for of dal communication with the licoroem However email addresses are public record. If you do not wish to supply a personal addrea, please provide the Department with an email address wNcti an be made available to the public To determine if you are a licensee under Chapter 455, F.S., please dick brere . Product Approval Accepts: ® ® Wq ".Sccurit�"� htfps:IA w .floridabdlcirg.orgtpr/pr app rill.aspx?param=wGEVXQwIDgvgqu2w%2bnFgUPv2pw6pKxAhf6SHQF12kzdQRng461FTFw%3d%3d 2/2 �l I KINITY J ERD Table Deck Application Type Description Page 1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5 1B-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5-9 18-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 10-11 1C Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 12 SD Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 13-14 1E Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 15-16 SF-1 Wood New or Reroof (Tear -Of) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 17-19 1F-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 20-22 SG Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 22 2A Steel or Conc. New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 23 2B Steel or Conc. New. Reroof (Tear -Of) or Recover C Mech. Attached Insulation, Bonded Roof Cover 24-25 2C Steel or Conc. New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 26-27 3A Concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 28-32 3B Concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 32 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 33-34 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 34 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 35-37 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 38 SB CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 39 5C CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 40 SD CWF New, Reroof (Tear -Oft) or Recover C Mech. Attached Insulation, Bonded Roof Cover 40 SE CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 40 6A Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 41-42 68 Gypsum Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 42 6C Gypsum Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 42 6D Gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 42 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 43-45 713 Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 45 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: D Wood: Minimum 0.75-Inch penetration. ➢ Steel: Minimum 0.75-Inch penetration and engage the top flute of the steel deck. ➢ Concrete: Minimum 1-inch embedment Into pilot hole in accordance with fastener manufacturer's published Installation Instructions. 3. Unless otherwise noted, Insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA requirements of FA.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. Exterior Research and Design, LLC. d/b/a Trinityl ERD Evaluation Report P9290.02.08-1137 for FL1654-1139 Certificate of Authorization ft9503 Revision 17:04/18/2016 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 1 of 45 rTRINITY I ERD 4. Minimum 200 psi, minimum 2-inch thick lightweight Insulating concrete may be substituted for rigid Insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Unless otherwise noted, Insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted In the manufacturer's published Instructions. ➢ Hot asphalt (HA): ' Full coverage at 25-30lbs/square. ➢ Dow Insta-Stlk Roofing Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons,12-Inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons,12-Inch o.c. ➢ OMG OlyBond 500 (08500): Continuous 0.75 to 1-Inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-Inch o.c. -, ➢ Note: When multiple layers(s) of Insulation and/or coverboard are Installed in ribbon -applied adhesive, board)ofnts shall be staggered. ➢ Note: The maximum edge distancefrom the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the specified ribbons spacing. - 6. Unless otherwise noted, all Insulations are Flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather If MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listedibelow may be used as a drop -In for the equivalent thicker material listed In the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-Inch thick) ➢ OMG OlyBond 506 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG OlyBond 506 (013500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+GL) ➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-Inch thick ENRGY 3) ➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-Inch thick ACFoam ll) ➢ICP Adhesives & Sealants CR-20: MDP -117.5 psf (Min. 1.0-inch thick) 7. Bonded polylsocyanurate Insulation boards shall be maximum 4 x 4 ft. 8. For mechanically attached components or partially bonded Insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117 and FM LPDS 1-29. Assemblies marked with an asterisk` carry the limitations set forth In Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 9. For fully bonded assemblies, the maximum design pressure forthe selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements,forthe system. Testing and analysis shall be In accordance with TAS 105 or ANSI/SPRI FX-1. 11. For existing substrates in a bonded recover Installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the AHJ, as documented through field uplift testing in accordance with ASTM E907, FM LPDS 1-52, ANSI/SPRI IA-1 or TA5124. 12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 13. LWIC shall be cast In accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck construction and limitations. For systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-Inches. For LWIC over structural concrete, reference Is made to FBC section 1917.4.1, Point 1. Exterior Research and Design, U.C. d/b/a Trinity] ERD Evaluation Report P9290.02.08-R37 for FL3654-R19 Certificate of Authorization #9503 Revision 17: 04/18/2016 Prepared by: Robert Nleminen, PE-59166 Appendix 1, Page 2 of 45 \ TRINITY ERD 14. Unless otherwise noted, refer to the following references for bonded base, ply or up sheet applications. TABLE II. POLVGLAss ROOF COVERS Reference Layer Material Appliwtlon BP -AA Base Ply One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II Hot Asphalt at 20-40 (Base and Ply sheets, Asphalt- Ply One or more plies Polyglass Ply IV, Polyglass Ply VI, FBC Approved ASTM D2178, Type IV or VI Ibs/square Applied) Note: Asphalt -applied sheets or Insulation shall not be applied to poly -film surfaced membranes. Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Polyglass HT Base 650 SBS-CA3 Cap Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshleld TS-G FR, Polyfresko G p6350 at 1.5-2.0 gal/square SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6 Polyplus 35 at 1.5-2.0 SBS-CA2 Cap Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshleld TS-G, Elastoshleld TS-G FR, Polyfresko G gal/square SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Base Ply or Ply One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex 56, Polyglass HT Base 650 SBS-AA (SBS, Asphalt -Applied) Cap Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 G, Elastoflex 56 G FR, Elastoshleld TS-G, Elastoshleld TS-G FR, Hot Asphalt at 20-40 Ibs/square Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed) Note: Asphalt -applied sheets or Insulation shall notbe applied to poly film surfaced membranes. Base Ply or Ply One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex 56, Polyglass HT Base 650 SBS-TA (SBS, Torch -Applied) Cap Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex 56 G, Elastoflex S6 G FR, Elastoshleld TS-G, Elastoshleld TS-G FR, Torch -Applied Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly-fllm backed) Base Ply One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR SBS-SA Cap Elastoflex SA P, Elastoflex SA P FR, Pal reflect Self -Adhering (SBS, Self -Adhering) Unless otherwise noted, permissible membrane substratesfor SBS-SA are limited to the SBS-SA Base Ply options herein, Note: Elastobase(poly/sand) or Elostobase(poly/poly). APP-TA Base Ply or Ply One or more plies Polyglass APP Base, Polyflex, Polybond Torch -Applied (APP, Torch -Applied) Cap Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR Cap Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool APP-SA (APP, Self -Adhering) Note: Unless otherwise noted, permissible membrane substratesforAPP-SA are limited to the SBS-SA Base Ply options herein, Self -Adhering Elastobase (poly/sand) or Elastobase (poly/poly). 15. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance. associated with coating usage. ➢ PG200 Non Fibered Roof Coating; ➢ PG300 Flbered Roof Coating; ➢ PG600 Non-Fibered Aluminum Roof Coating; D PG650 Fibered Aluminum Roof Coating; D PG700 High Quality Elastomeric Roof Coating or KM Acryl 25; D PG700Q5 (Quick Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS (for granule -surfaced APP or SBS only); ➢ PG800 Asphalt Emulsion Roof Coating; ➢ Polyplus 60 Premium Non-Flbered Aluminum Roof Coating; D Polyplus 65 Premium Fibered Aluminum Roof Coating; ➢ Polybrite 70 Premium Grade Elastomeric Roof Coating or KM Acryl 15; D Polybrite 70QS (Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-QS (for granule -surfaced APP or SBS only); ➢ Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating. Exterior Research and Design, U.C. d/b/a Trinity) ERD Certificate of Authorization h9503 Prepared by: Robert Nieminen, PE-59166 Refer to current Roofing Materials Directory for fire ratings Evaluation Report P9290.02.08-R17 for FL1654-R19 Revision 17: 04/18/2016 Appendix 1, Page 3 of 45 VTRINITYIERD 16. The following represent priming requirements for gypsum -based coverboards: ➢ Dens Deck and Dens Deck Prime shall be field -primed with PG300 prior to self -adhering ortorch-applied membrane application. No priming is required for hot -asphalt membrane applications. ➢ SECUROCK Gypsum -Fiber Roof Board does not require field priming for any membrane application. 17. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MOP) limitations. The lesser of the MDP listings below vs. those In Table 3A applies: VAPOR BARRIER OPNONSI STRUCNHAL CONCRETE DECK, ADHERED INSULATION PER TABLE 3A _ Option# Primer Vapor Barrier Insulatlon Adhesive MOP(psf) Type Attach 1 PG300 Elastoflex SA V Plus Self -Adhering Inta-Stik or CR-20, 12-inch o.c. -60.0 2 PG300 Polyglass APP Base Torch -applied Inta-Stik or CR-20, 12-Inch o.c. -75.0 3 PG100 Elastoflex SA P Self -Adhering Insta-Stik, 12-Inch o.c. -75.0 4 PG100 Elastoflex SA P Self -Adhering Millennium One Step Foamable Adhesive, 12-Inch o.c. -157.5 5 PG300 Elastoflex SAP Self -Adhering CR-20, 12-Inch o.c. -270.0 18. "MDP" = Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, I.I.C. d/b/a Trinity[ ERD Evaluation Report P9290.02.08-1117 for FL1654-R39 Certificate of Authorization #9503 Revision 17: 04/18/2016 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 4 of45 \1 I KINITY ERD TABLE IA: WOOD DECKS —NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Deck Base Insulation Layer Top Insulation layer Roof Cover (See Table 1) MOP No. (See Note 1) Type Attach Type Attach Base Ply PlyCap (PsQ SEL ADHERING BASE PLY: MIn. 15/32- Min.1.5-Inch ACFoam II, ACFoam III, ENRGY-3, H- D-IS, M-OSFA, (Optional) additional ID -IS, M-OSFA, SBS-SA (Optional) SBS-SA, 5B5-TA, SBS-SA, APP-SA, 52.5 W-1 Inch plywood Shield, H-Shield CG, Multi -Max FA3 OB%0 or CR-20 layers(s) of base insulation OB500 or CR-20 APP-TA SBS-TA, APP-TA W 2 Min. 15/32- Min. 1.5-Inch ACFoam II, ACFoam III, ENRGY-3, H- D-IS, M-OSFA, (Optional) additional I D-IS, M-OSFA, Polyflex SA (Optional) APP-TA APP-TA -52.5 Inch plywood Shield, H-Shield CG, Multi -Max FA3 OB500 or CR-20 layers(s) of base Insulation I OB500 or CR-20 Base TABLE IS-1: WOOD DECKS— NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE A-2: MECHANICALLY ATTACHED ANCHOR SHEET, BONDED INSULATION, BONDED ROOF COVER Anchor5heet Base Insulation Top Insulation Roof Cover (See Table 1) MOP System Deck No. (See Note 1) Type Fasten Attach Type Attach Type Attach Ply Ply Cap (PFH ASPHALT -APPLIED OR TORCH -APPLIED BASF PLY: ' 9-Inch o.c. at 2-Inch (Optional) Min. 1.5- Min. 0.75-Inch Fesco Board Elastobase, lap and 18-Inch o.c. Inch ACFoam It, (homogeneous) or min. Hot BP -AA (Optional) SOS -AA, W-3 Min. 15/32- Elastobase P Simplex MAXX in two (2), equally ENRGY-3, H-Shield, Hot asphalt 0.5-Inch Structodek High or SBS- BP -AA or 585-TA, -45.0• Inch plywood (sanded -top) Cap spaced, staggered H-Shield CG, Multi- Density Fiberboard Roof asphalt AA SBS-AA APP-TA center rows Max FA3 Insulation - 9-Inch ox. at 2-Inch (Optional) Min. 1.5- Min. 0.25-Inch Dens Deck, BP -AA, (Optional) Min. Elastobase, Slmplex MAXX lap and 18-Inch ox. Inch ACFoam II, Dens Deck Prime, Hot SBS-AA, BP -AA, 505- SBS-AA, W-4 ywoo inch plywood ElastobaseP Cap In two (2), equally ENRGY-3, H-Shield, Hot asphalt SECUROCK Gypsum -Fiber asphalt 585-TA, AA, 5B5-TA, SBS-TA, -45.0• (sanded -top) spaced, staggered H-Shield CG, Multi- Roof Board APP-TA APP-TA APP TA center rows Max FA3 9-Inch o.c. at 2-Inch (Optional) Min. 1.5- Min. 0.75-Inch Fesco Board Elastobase, lap and 12-Inch o.c. inch ACFoam II, (homogeneous) or min. BP -AA (Optional) SOS -AA, W-5 Min. ElastobaseP Simplex MAXX in two (2), equally ENRGY-3, H-Shield, Hot asphalt 0.5-Inch Structodek High Hot or 585- BP -AA or SBS-TA, -52.5 Inch pllywood plywood (sanded -top) Cap, spaced, staggered H-Shield CG, Multi- Density Fiberboard Roof asphalt AA SBS-AA APP-TA center rows Max FA3 Insulation 9-Inch o.c. at 2-Inch (Optional) Min. 1.5- Min. 0.25-Inch Dens Deck, BP -AA, (Optional) MIn. Elastobase, Simplex MAXX lap and 12-Inch o.c. Inch ACFoam II, Dens Deck Prime, Hot SBS-AA, BP -AA, SBS- SBS-AA, W-6 ywoo Inch plywood ElastobaseP Cap in two (2), equally ENRGY-3, H-Shield, Hot asphalt CK Gypsum -Fiber asphalt SBS-TA, AA, SBS-TA, SBS-TA, -52.5 (sanded -top) spaced, staggered H-Shield CG, Multi- Roof BoSECUR Roof Board APP-TA APP-TA APP TA center rows Max FA3 Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report P9290.02.08-R17 for FL1654-R19 Certificate of Authorization #9503 Revision 17: 04/18/2016 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 5 of 45 \l TRINITY ERD TABLE 3A: CONCRETE DECKS —NEW CONSTRUCTION DR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER NOTE: FOR VAPOR BARRIER OPTIONS REFER TO NOTE 17 System Deck Base Insulation layer Top Insulation Layer Roof Cover (See Table 1) MOP No. (see Note L) Primer Type Attach Type Attach Base Ply Ply Cap (Psf) Hot (Optional if using AA (Optional if using AA Base) SBS-AA, SBS-TA, C-67 Concrete PGI00 Min. 0.25-Inch Dens Deck Prime asphalt None N/A Ply) BP -AA, SBS-AA BP -AA, SBS-AA, SBS-TA or APP TA -510.0 APP-TA COID-APPDEO BASE: Min. 0.25-Inch Dens Deck C-68 Concrete None Min. 1.5-Inch ACFoam II or H-Shield OBS00 Prime or SECUROCK OB500 SBS-CA3, SBS-CA2 None SBS-CAS, SBS- -90.0 Gypsum -Fiber Roof Board �2 Min. 1.5-Inch ACFoam II, ACFoam III, 3, H- Min. 0.25-Inch Dens Deck SBS-CAL, SBS- C-69 Concrete None Shield, H-Shield CG, Multi -Max FA3 orr ISO ISO 95+GL CR-20 Prime or SECUR CR-20 SBS-CAI, SBS-CA2 None CA2 -90.0 Gypsum -Fiber Roofoof Board TABLE 3B: CONCRETE DECKS— NEW CONSTRUCTION OR REROOF (TEAR -OFF) SYSTEM TYPE F: NON -INSULATED, BONDED BASE SHEET, BONDED ROOF COVER Deck Roof Cover (See Table 1) System No. (See Note 1) Primer MDP(psf) Base Ply Ply Cap C-70 Concrete PG100 SBS-SA (Optional) SBS- SA, SBS-TA, APP-TA SBS-SA, APP-SA, SBS-TA, APP-TA -315.0 G71 _ C ety 100 poi, le .i4 80 Ogt- GP 7A p•TA .O C-72 Concrete PG100 BP -AA (Optional if using asphalt applied Ply) (Optional if using asphalt applied Base) BP -AA, SBS- SBS-AA, SBS-TA, APP-TA -622.5 AA, SBS-TA or APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report P9290.02.08-1117 for FL3654-R39 Certificate of Authorization R9503 Revision 17: 04/18/2016 Prepared by: Robert Nieminen, PE-59166 Appendix 1, Page 32 of 45