Loading...
HomeMy WebLinkAboutMISC EMAIL.p 3&017 G&0- ng Construction Inc Mail- Treasure Cove Dww PMN rBdstirg Assembly O -- - RECElt._p j1q-. 1, - -- -Mark-Flicidnger<mark@cflroofing.com> Treasure Cove Dunes-PMMA over Existing Assembly 1 message Raukfls, Todd <Todd.Rauktis@jm.com> Wed, Mar 8, 2017 at 2:56 PM To: Mark Flickinger<mark@cflroofing.com> OUANNED BY 3t Lucie Countv Mark- - - — _ . �• Please be advised that ttt RR sirng:ro ,JJ a Johns"Manville Hot Applied SHS sysfe n over insulation and pedite/ fesco coverboard, also applied in hot asphalt, over a concrete deck. Please see�attacftedtBG. re isflee Lie ex+slmg';r instaUedsystf have highlighted the system on the Tdnity/ERD report, C4. This should satisfy the below requirement of "FBC Approval Documentation. From the Submitted PMMA FBC Report ... Noted Item from Building Department 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the AHJ. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. Let me know if you have any questions. Thanks Todd Rauldis Sr. Sales Representative - Central Florida j Roofing Systems Group Johns Manville i A Berkshire Hathaway Company C: 407-429-8626 Email: Todd.Rauktis@jm.com I M" Johns Manville 91 U 0 MHOOMILNEWS This email, including attachments, is intended for the person or company named and may contain confidential and/or legally privileged information. Unauthorbmd disclosure, copying or use of this information may be untawful and is prohibited. ti you are not the intended recipient, please delete this message and notify the sender. Johns Manville is a manufacturer of commercial roofing products and offers this general conceptual information to you as a courtesy only. This complimentary as is not to be used or relied upon by anyone as a substitute for professional engineering design and documentation required by building code, contract or applicable law. By accepting these comments you agree they do not constitute any representations, endorsements of, or an assumption by Johns Vn aSW7 GBG-'-;igConstruction Inc: MWI- Treasure Cove DunesPMM'- ' ; NstingAsserntdY Manville of any responsibility/liatinny or either the adequacy of the design of thi: dinghoofing system, code compliance, material or any other material not supplied by Johns Manville. �r TDC Existing Assembly JIW SBS FL2948-R11.pdf —.. .. _ 1923K__---- --- W RZ -DJr-1E5 IIRCASu 12c07 AS_,5 L_ ^6LY TRII�I�TYER® TABLE 3A-1: STRUCTURAL CONCRETE DECKS —NEW CONSTRUCTION oR REROOF (TEAR -OFF) SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER NOTE: FORVAPORBARRIER OPTIONS, REPERTO NOTE 15 Base Insulation layer Top Insulation layer Roof Cover (Note 141 MOP 1psA System Deck primer Attach Type Attach Base Ply Ply Cap PIY' No. IN.m t1 Type (Optional) MIn.1.5-Inch ENRGY 3, -Panel, ENRGV325 PSI, R-Panel P51, ENRGY3 JM BaseGrlp (optional) SBS-AA, SBS- SBS-AA, SBS- _755.0 Structural ASTM AGF or CGF, ENRGY 325 PSI AGF or CGF, HA Min. 1.5-Inch lnvinsa Foam HA SD/SA TA TA C-1, concrete D41 ValuTherm AGF or CGF, ValuTherm 25 PSI AGFor CGF (Optional) Min. 0.75•Inch BP - AA, BP•CA2, (Optional) BP -AA, SBS- SSS-AA,SBS- _167.5 Structural ASTM MIn.0.75-Inch FeswBoard or DuraBoard HA FescoBoard or DuraBoard NA SBS•AA or SBS- AA, SBS-C42 or SBS •TA CA2, SBS-TA C-2. concrete D41 (homogeneous) (homogeneous) CA2 MIn. 1.5-Inch ENRGY 3, R-Panel, ENRGY 3 25 BP -AA, 5B5-AA, (Optional) BP -AA, BP- 585•AA, SBS- SWctural ASTM PSI, R•Panel 25 PSI, ENRGY 3 AGF or CGF, Min. 0.25-Inch SECUROCK HA HA SBS-CA2or SBS- CA2, SB5-AA, SBS-CA2 CA2 or5B5- -247.5 C-3. concrete D41 ENRGY 325 PSI AGF or CGF, ValuTherm AGF Gypsum -Fiber Roof Board TA or5B5-TA TA or CGF, ValuTherm 25 PSI AGF or CGF Min. 0.5-Inch Retro-Fit Board, BP -AA, BP-CA2, SBS-AA, SBS ¢Y""'�;E'. 2775-': ,:S'. C Structural ASTM MIn. 1.5-Inch ENRGY3CGF, ENRGV325 P51 RetroPlus Board or HA DuraBoard or min. 0.75-Inch HA SBS-AAor SBS- AA(opSBS-CA2•AA,S-TABS- AA, SBS-012 or 5B5.7A CA2 or SBS- TA ,t concrete D41 CGF, ValuTherm CGF, ValuTherm 25 PSI CGF Fesco Board CA2 Min. 1.5-Inch Fesco Foam or HA BP -AA, BP-CA2, SBS-AA or SBS- (Optimal) BP -AA, SBS_ SBS-AA, SBS- CA2 or SBS- -277.5 O anal) Min. 1.5-Inch ENRGY 3 CGF, (optional) (� ASTM ENRGY 3 25 PSI CGF, ValuTherm CGF, DureFoam CA2 AA, SBS-CA2 or SBS-TA TA C•5. concrete D41 ValuTherm 25 PSI CGF Structural ASTM Min.1.5-Inch ENRGY 3 CGF, ENRGY 325 PSI HA Min, 0.5-Inch DumBoard HA SBS-TA (Optional) 585.7A SBS-TA -277.5 C-6, concrete D41 CGF, ValuTherm CGF, ValuTherm 25 PSI CGF Mil n.1.5-Inch ENRGY 3, R•Panel, ENRGY 325 (optional) sas-7A 5BS TA -300.0 Structural ASTM PSI, R-Panel 25 PSI, ENRGY 3 AGF, ENRGY 3 HA Min. 0.5•Inch DuraBoard HA Sss-Tw C-7. concrete D41 2S PSI AGF, ValuTherm AGF, ValuTherm 25 PSI AGF Min.1.5-Inch ENRGY 3, R-Panel, ENRGY 3 25 MIn.0.5-Inch RaVaPlus BP -AA, BP-CA2, SBS- SBS-AA, 585- for SBB- -300.0 Structural ASTM PSI, R•Pane125 P51, ENRGY 3AGF, ENRGY3 HA Board or DurdBoard HA SBS-AA or S85- AA SBS•CA2er585•TA AA,(opSBS-CA2 or TA C-8. concrete D41 25 P51 AGF, ValuTherm AGF, ValuTherm 25 CA2 PSI AGF MIn. 1.5•Inch ENRGY 3, R-Panel, ENRGY 325 Mtn..0.5-Inch Retra-Fit Board BP -AA, BP-CA2, (Optional) BP -AA, SBS- SBS•AA,SfiS- CA2 or 585- -305.0 structural ASTM PSI; R-Panel 25 PSI, ENRGY 3 AGF, ENRGY 3 HA or min. 0.75-Inch Fesco Board HA SBS-AAor SBS- SBS-CA2 or SB5-TA TA C-9. D41 25 P51 AGF, ValuTherm AGF, ValuTherm 25 or ouraBoard CA2 concrete PSI AGF 58S•AA, SBS- (Optional) MIn.1.5-Inch ENRGY 3, R-Panel, Min. 1.5•Inch Fesco Foam or BP -AA, BP-CA2, SBS-AAor SBS- (optional) SP-AA, SBS- CA2 er SBS• -305,0 Structurel ASTM ENRGY 325 PSI, R•Panel 25 PSI, ENRGY3 HA HA AA, 585-CA2 ar585-TA AA TA C-10. concrete D41 AGF, ENRGY PSI AGF, ValuTherm AGF, DuraFoam CA ValuTherm 25 PSI AGF Evaluation Report 18230.03.08-1110 for F12948•1171 Exterior Research and Design, LLG d/b/a TrinitY(ERD FBC NON-HVHZ EVALUATION Revisio16 Appendix 1, Page 22 of 52 ppendln 1, :age 22 of 52 Cert(llco[e of Authorization N9503 Prepared by: Robert Nleminen, PE-59166