Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE) f/j'jY� n �•i Planning & Development Services Department • Building & Code Regulations Division Om16'qu '19 2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-1553 SCANNED BY • Certification for Design Load Compliance St. Lucie Counts Project Name: Barclay Beach Club Project Address: 2800 North Highway Al A, Fort Pierce, Florida 34949 Permit#: Occupancy Type: R-2 Construction Type: II -A • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I _II X III _ IV Exposure Category: _B _C X D 4. Design Wind Velocity 170 mph X ASD _LRFD End Zone Width: 10 ft 5. Mean Roof Height 15 ft Roof Pitch: N/A :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: N/A Zone 2: N/A Zone 3: N/A Zone 4:70-76 Zone 5: 70-80 Garage: N/A 7. Design Loads: Floor: NSA PSF Roof/Dead: NIA PSF Roof/Live: N/A Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? _Yes X Not Applicable Explain Why Not: DOOR REPLACEMENT ONLY 9. Is A Continuous Load Path Provided? _Yes X Not Applicable Explain Why Not: DOOR REPLACEMENT ONLY 10. Design Soil Bearing Pressure: NSA PSF Soil Test Reports Submitted? N/A Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also tcl� l f (Tat structural elements depicted on these plans provide adequate resistance to the design forces suaoia FF v., 11'. Gary L. Karel P.E. FL PE #51406 y� {��p e. /y * Print Name Cent # & Co. Cent Auth. _ f iV . 51406 i OC= G.L. KAREL - Building & Engineering EU Sig Dag;q80— 6675 Flamingo Road, Melbourne Village, Florida 32904 �(OFttpP , `C7�\N Company Name & Address Revised 07/�A,. 'rlllllll��� Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance Project Name: Barclay Beach Club Project Address: 2800 North Highway A1A, Fort Pierce, Florida 34949 Permit #: Occupancy Type: R-2 Construction Type: 11=A INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I _II X III _ IV Exposure Category: _B _C X D 4. Design Wind Velocity 170 mph X ASD _LRFD End Zone Width: 10 ft 5. Mean Roof Height 15 ft Roof Pitch: N/A :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: N/A Zone 2: N/A Zone 3: N/A Zone 4: 70-76 Zone 5: 70-80 Garage: N/A 7. Design Loads: Floor: NSA PSF Roof/Dead: NIA PSF Roof/Live: N/A Balcony: N/A PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? _Yes X Not Applicable Explain Why Not: DOOR REPLACEMENT ONLY 9. Is A Continuous Load Path Provided? _Yes X Not Applicable Explain Why Not: DOOR REPLACEMENT ONLY 10. Design Soil Bearing Pressure: NIA PSF Soil Test Reports Submitted? N/A Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. �IL�15bidAdtl9yj��t structural elements depicted on these plans provide adequate resistance to the design Gary L. Karel P.E. FL PE #51406 Print Name Cert # & Co. Cert Auth. Z. G.L. KAREL - Building & Engineering -01 e, eall` 6675 Flamingo Road, Melbourne Village, Florida 32904 '�� �0W Company Name &Address