Loading...
HomeMy WebLinkAboutPLANSverizonl/ l 4700 EXCHANGE COURT — SUITE 100 BOCA RATON, FLORIDA 33431 PHONE (561) 995-5500 SCANNED BY VERIZON WIRELESS SITE NAME / GOZER NUMBER St. LucieCounty WEST M I DWAY/ # 69032 CROWN BU# 800642 lcp��l�® 16800 OKEECHOBEE ROAD MAR 0 9 2017 FORT PIERCE, FL 34945 PERMITTING LATITUDE 27°22'53.30"N, LONGITUDE 80'29'48.40"W NAD 83 St. Lucie County, FL i I I ` i i VICINITY MAP D FROM VERIZON OFDCE: HEAD SOUTH ON EXCHANGE CT TOWARD 'TECHNOLOGY WAY, TURN LEFT ONTO TECHNOLOGY WAY, USE THE RIGHT 2 LANES TO TURN RIGHT ONTO NW 51ST ST/YAMATO RD, TURN LEFT TO MERGE ONTO 1-95 N TOWARD W PALM BEACH, MERGE ONTO 1-95 N. TAKE EMT 126 FOR COUNTY RD 712/MIDWAY RD. SHARP LEFT ONTO W MIDWAY RD. TURN LEFT ONTO FL-70 W. TURN RIGHT ONTO S HEADER CANAL RD, THE SITE WILL BE ON THE RIGHT. LDRIVING DIRECTIONS I THE SCOPE OF WORK CONSISTS OF MODIFYING THE EXSTINC WIRELESS INSTALLATIONS: 1. REMOVE (6) EXISTING ANTENNAS 2. REUTLTZE (3) EXISTING ANTENNAE 3. REUTUZE EXISTING (12) 1 5/8- COAX CABLES 4. INSTALLATION OF (5) NEW ANTENNAS 5. INSTALLATON OF (3) TOWER MOUNTED BIAS-T 6. INSTALLATION OF (6) TOWER MOUNTED DIPLEXERS (DBC-]CAP) ]. INSTALLATION OF (0) GROUND MOUNTED DIPLEXERS (DBC-]CAP) SCOPE OF WORK I ALL WORK AND MATERMI-S SHALL BE PERFORMED AND INSTA11E0 IN ACCORDANCE WITH THE CURRENT EOMONS OF THE FOLLOWNG CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORTES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1. STH EOITON, 2014 PLORIOA BUILDING 6. AMERICAN INSDIDTE OF SMO- CODE CONSTRUCTION PECIRCATONS (AISC) 2. NATONAL ELECTRIC CODE (NEC) qDN >. UNDERWRITERS LABORATMICS LOCAL AMENDMENTS LAT:ST ED. (OL) APPROVED EECi CAL 1 ANSI/DA/ETA APPUCABIE STANDARDS PRODUCTS 4. UFE SAFETY COPE NMA-101-2015 8. LOCAL BUILDING ME 5. SIP EDITION. FLOBDA RRE S. CITY/COUNTY ORDINANCES PRE D CODE COMPLIANCE APPLICANTILESSEE MOCK NAME: VERIZON WIRELESS PROJECT MANAGER: KATHY CICERO PHONE: 561-995-5590 PROPERTY INFORMATION TOWER OWNER: CROWN CASTLE INTERNATIONAL 6420 CONGRESS AVE SUITE 2000 BOCA RATON. FL 33487 HANDICAP REQUIREMENTS: FACIUTY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS NOT REQUIRED. PARCEL 10: 3201-244-0039-00C-S JUMSDICTON: ST. LUCIE COUNTY PROJECT INFORMATION EQUIPMENT LOCATION: ® OUTDOOR ❑ INDOOR PROJECT SUMMARY KIMLEY-HORN AND ASSOCIATES, INC. 192D WEKIVA WAY WEST PALM BEACH, FLORIDA 33411 MARTIA MARTIN (561) 845-0665 STRUCTURAL ENGINEER: N/A ELECTRICAL ENGINEER: N/A SHEET DESCRIPTION REV. 1 COvER SHEET 0 2 SITE PLAN LAYOUT. ENLARGED PLAN AND NOTES 0 3 TOWER ELEVATION AND ANTENA ORIENTATION 4 ANTENNA DETAILS 0 5 VERIZON REDS 0 SHEET INDEX ISSUED FOR: RET/4XRX UPGRADE DATE: FEBRUARY 2017 DESIGN: - 5TH`EDITON, 2014 FLORIDA BUILDING CODE WINO LOADS (ASCE ]-10) ULTIMATE SPEED - 160 MPH SURVEYOR: NOMINAL NOD PEED - 124 MPH N/A RISK CATEGORY II WIND EXPOSURE = C I PROJECT TEAM I v riz n 47M EXCHANGE CT, SUITE 100 BOCA RAION, P. 33431 (551) 93 mm PROJECT INFORMATION: WEST MIDWAY SITE No. 69032 16800 OKEECHOBEE ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY URRENT ISSUE DATE: 11 FEBRUARY 2017 ISSUED FOR: RET/4XRX UPGRADE :====DESCRIPTION• , s ` 9, i23V ACeY.. off,^IS� �• �R/P�N fk!� 4'Horn © =7 MY -HORx Axo ASSCCUIES MC 1920 WEKIVA WAY WEST PALM BEACH, FLORIDA J3411 (561) 845-0665 PEPE CA000W96 ROJECT DATA (AWN BY:=CHK.: APV.: RHO I MM MM CENSURE ARNWO A ARMES PE ]0845 MARIA V. MARTIN PE >2!9] KENN K MA4AM PE W455 FEET COVER SHEET HEET NUMBER• 1 OF 5 KHA Job $: 044290115 P �X X X X X—� A A A A A X E%MLR A �Qp GENERATOR ON CONCRETE PAD EXISTING FIBER HAND HOLE X EXISTING EMPTY CONCRETE PAD X EXISTING EQUIPMENT ON EXISTING CONCRNCRETEEPAD EQUIPMENT SHELTER X EXISTING ICE BRIDGE (TYP.) V X 0 EXISTING VEMZON WIRELESS 500 GALLON UP TANK X X X— EXISTING VERIZON WRELESS EQUIPMENT ON CONCRETE PAD NORTH a s Iz SCALE FEET EXISTING SELF-SUPPORT TOWER +"/^'�X X X X EXISTING CHAIN NK FENCE X X EXISTING GENERATOR ON CONCRETE PAD X /c X EXISTING EOUIPMENT SHELTER X EXISTING ICE BRIDGE (TYP.) X X X X X---j SITE PLAN EXISTING VERIZCN WIRELESS CONCRETE PAD EXISTING VERIZON WIRELESS ICE BRIDGE (TYP.) EXISTING MERIZON WIRELESS TELCO CABINET EXISTING VERIZON WRELESS TELCO CABINET o EXISTING MERIZON WIREIPSS AC PANEL EXISTING VERRON .I. DISCONNECT W/GEN PLUG BELOW ENLARGED EXISTING VERIZON WIRELESS EQUIPMENT PLAN 111xel2112IF OA EXISTING VERIZON WIRELESS GENERATOR NORTH OB EXISTING VERIZON WIREI-ESS BRAN © EXISTING VERIZON WIRELESS COMA ON BRAM 9L� 5]II•��sII Op EXISTING VERIZON WIRELESS 6101 CABINET SCALE O PROPOSED (6) DIPLEXERS (DBC-7CAP) MOUNTED TO PROPOSED RAC( (SEE SHEEP 4) EXISTING VERIZON WIRELESS CONCRETE PAD NOTE: WE CONTRACTOR SHALL VERIFY CABLES/REINFCRCEMENT LOCATION BEFORE ANY CONCRETE ANCHOR INSTALLATION EXISTING VERIZON WIRELESS ICE BRIDGE (TYP.) BASTING VERIZON WIRELESS TELCO CABINET EXISTING VERIZON WIRELESS TELCO CABINET D EXISTING VERIZON WIRELESS AC PANEL EXISTNG VERIZON WRELESS DISCONNECT W/GEN PLUG BELOW ENLARGED PROPOSED VERIZON WIRELESS EQUIPMENT PLAN CONSTRUCTION NOTES SCOPE OF WORK: FURNISH ALL LABOR, MATERIALS, TOOLS, SUPPLIES. EQUIPMENT AND MACHINERY NECESSARY TO COMPLETE TIRE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. MATERIALS OR WORK DESCRIBED IN WORDS WHICH HAVE A WELL KNOWN TECHNICAL TRADE MEANING SHALL BE HEFT TO REFER TO THE RECOGNIZED STANDARD. ALL MATERIALS SHALL BE NEV. UNLESS OTHERWISE SPECIFIED. CODES: ALL WORK PERFORMED AND MATERIALS USED SHALL MEET ALL REQUIREMENTS OF THE LATEST ADOPTED EDITION OF THE BUILDING CODE, STATE CODES, AND LOCAL CODES, ORDINANCES, AND REGULATIONS HAVING JURSDICTON. -WE-CONTRACTOR SHALL -SECURE-AND-PAY-FOR4HE-BUILDING-PERMfEAND-ALL REQUIRED -OTHER PERMITS AND FEES, UCENSES. AND INSPECTIONS NECESSARY FOR THE PROPER EXECUTION AND COMPLETION OF WE MRK. WE EXISTING CONDITIONS SHOWN IS DIAGRAMMATIC AND BASED UPON THE BEST INFORMATION AVAILABLE HOWEVER, MAY NOT REFLECT ALL MEW CONDITIONS AT THIS TIME. VERIFY ALL DIMENSIONS IN WE FIELD PRIOR TO BEGINNING WORK. THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE ENGINEER OF ANY DISCREPANCIES BETWEEN TRESS PLANS AND EXISTING FIELD CONDITIONS. STORAGE h INSTALLATION: ALL MATERIALS AND EQUIPMENT SHALL BE STORED AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS UNLESS OTHERWISE NOTED. PROTECTIONS: PROTECT WITH TEMPORARY BARRICADES, COVERINGS, OR OTHER PROTECTONS TO PREVENT IN.NRY OR DAMAGE TO PERSONS OR PROPERTY. WE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY HIS OPERATIONS. �verizon 47M EXCHANGE IT. SUITE 100 BOLA RATON, FL 130.T1 (551) 995-55DO WEST MIDWAY SITE No. 69032 16800 OKEECHOBEE ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY :CURRENT ISSUE DATE: FEBRUARY 2017 REf/4XRX UPGRADE © 20F7 HIMI£Y-HQTN A ASSOCIART. INC. 1920 WEKIVA WAY WEST PALM BEACH, FLORIDA J3411 (561) 845-0655 RHO 1 MM MM ARNO DO A. ARTLES PE 70645 MARIA V. MARTIN PE 72197 KEWN K. MmR PE 71455 SITE PLAN LAYOUT, NLARGED PLAN AND NOTES 2 OF 5 :KHA Job #: 044290115 EXISTING VERIZON WIRELESS ANTENNA TO BE REMOVED (1 PER SECTOR) (3 TOTAL) TD p1PM0{ NOTE: FCC REGISTERED HECHT 1 W/APPURTENANCES IS 255' TOP OF T0� FL = 245'2 A.G.L RAD CENTER OF EXISTING AND PROPOSED�AANTENNAS CL `,VERIZON Y r'zn P SOP.OMMIN (9) EXJSTNG ANTENNAS, 6 EXISTING )REPLACED 4100 E%CHANGE CL SANE iW BOCA RAT4N, FL 334]1 (361) 99S-5500 TO EXISTING VERIZON WIRELESS MM ANTENNA TO BE REMOVED (1 PER SECTOR) (3 TOTAL) ANTENNAS TO BE REMOVED AND WITH (6) NEW ANTENNAS, EMSRNG MOUNT TO REMAIN. PROJECT INFORMATION: WEST MIDWAY pT,\MOM EXISTING VERIZON WIRELESS EXISTING ANTENNA 250 ANTENNA TO BE RELOCATED SITE No. 69032 (I PER SECTOR) (3 TOTAL) pVM3M EXISTING YERIZON 5EG: WIRELESS MOUNT TO EXISTING ANTENNA FORT PIERCE, FL 3 9445 ST. LUCIE COUNTY REMAIN URRENT ISSUE DATE: FEBRUARY 2017 SSUED FOR: MM Rp,DMUtM .o - EXISTING ANTENNA RET/4XRX UPGRADE S GS 250 sd yL'3 EV.:=DATE:—DESCRIPTION: 9 SEAL:;1F.4`+1F�/ Sd EXISTING 245' L{y SELF-SUPPORT TOWER 0..V.,>/ �// •,,,�.,�G�P EXISTING ANTENNA ORIENTATION DIAGRAM N.T.S z t�De is��`j�_(,, = PROPOSED VERIZON WIRELESS ANTENNA PROPOSED VERIZON WROESS OAS-T PROPOSED NERIZON WIRELESS k pOM OIPLE)fER (TYP. OF 2)� as TO PDM S F#E - ` 4 •�"R '•S4/;I.Cir1�fiorn PROPOSED VERIZON WIRELESS ANTENNA RELOCATED VERIZON MM p1\ 2� Mp O p2\MXXN 2` PROPOSED VERIZON WIRELESS ANTENNA—� M CS p1\MMN 250 PROPOSED VERIZON WHELESS (2) BIAS-T pg NOTES: a 1. SAFETY CUMB AND CLIMBING PATH MAY NOT BE OBSTRUCTED IN ANY WAY. s `g IF DEVIATION FROM THE DESIGN IS REQUIRED, SUCH BUT NOT UNITED TO THAT DIPLEXERS, BIA-rS(; DESIGN, ETC- CANNOT BE INSTALLED AS DESIGNED BEHIND THE ANTENNAS. NE VERIZON CONFESS CM IS TO CONTACT THE CROWN CM TO BEST PATH FORWARD AND ENSURE THE MAAS MA AS WELL AS THE SA ARE STILL CONSIDERED � PASSING. CS�p ow' TO' PROPOSED VER12ON WIRELESS ANTENNA MN SF-T vrO '4QW PROPOSED VERIZON WIRELESS DIPLEXER (TYP. OF 2) PROPOSED V IZON WREESS BIAS-T '1 PROPOSED �MIZCN CRElE55 ANTENNA �y L� , PROPOSED yQN� RE-ESANTENNA VERIZON PROPOSED ANTENNA ORIENTATION DIAGRAM N.T.S )'101I [I{I1I OI?N Al A66CCIARM INC 1920 WEKIVA WAY WEST PALM BEACH, FLORIDA 33411 (561) 64�0665 FBPE CAOO 696 NOTE: THIS DRAWING IS INTENDED TO DEPICT THE GENERAL LOCATION AND HECHT OF THE PROPOSED LOADS ON THE EXISTING TOWER CONSTRUCTION SHALL NOT PROCEED UNTIL RAWN BY: CHK.: APV.: p STRUCTURAL OPINION PROFESSIONAL HAS BEEN RHO MM MM COMPLETED IN A PROFESSIONAL ENGINEER REGISTERED IN THIS STATE, CONCWDINC THAT THE EXISTING TOWER IS STRUCTURALLY ADEQUATETO RESIST THE CENSURE EXISTING AND PROPOSED LOADS ARNDL00 A M1RE5 170.1- MARA V. MARTIN KENN K. MARA.H HEET TITLE TOWER ELEVATION AND ANTENNA ORIENTATION HEET NUMBER: TOWER ELEVATION N.T.S. F 5 11..D LL EXISTING & PROPOSED ATTACHMENTS TO TOWER BASED ON STRUCTURAL ANALYSIS BY OTHERS. O 2. FOR CLARITY, EXISTING GROUND EQUIPMENT FOR OTHER CARRIERS NOT SHOWN. $: J. CONTRACTOR TO COORDINATE ANTENNA MOUNTS W/ VERIZON GPM. P-KHA Job 4. CONTRACTOR TO REFER N STRUCTURAL ANALYSIS (BY OTHERS) 044290115 ]00 0 ,t AWS/PCS. ws ws -0i K5 NOTE: ANTENNA DIAGRAMS ARE BASED ON RFDS DATED 07-12-16 AlPHA2 as ]� TRUE o NORTH C 1 0 Axrt AWSIPCSANT.: ws ws -45 i9 1 1 ANTENNA LAYOUT N.T.S. NOTE 1. ADD (6) NEW ANTENNA 2. VERI20N WIRELESS CURRENTLY HAS (12) 1 5/8' COAXIAL CABLES INSTALLED. 3. ADD (3) BIAS-T 4. ADD (6) OIPLEXERS 5. REQUEST CURRENT RFOS BEFORE INSTALLATION. VERIZON WIRELESS ANTENNA PROPOSED PIPE MOUNTING BRACKETS PROVIDED W/ANTENNA (TYP.) PROPOSED ANTENNA TILT BRACKET PROVIDED W/ANTENNA MOUNTING PIPE PROPOSED ANTENNA J I BRACKET PROMDED U W/ANTENNA PROPOSED ANTENNA MOUNTING DETAIL N.TS SHELTER 270' GAMMA SECTOR (2: SECTOR (70') (140') 18U' CONTRACTOR SHALL USE SURVEY INFORMATION TO AUCN ORIENTATION OF ANTENNA SUPPORT STRUCTURE(S) WITH BEARINGS SHOWN IN DIAGRAM ABOVE. ANTENNA ORIENTATION DIAGRAM N.T.S. EXISTING ICE BRIDGE POST MAX. BETWEEN VERTICAL EXISTNG COAX MEMBERS SHALL BE 4B' BRIDGE POST TYR. PROPOSED DIPLEXERS (DEC -]CAP) MOUNTED TO PROPOSED RACK. rxFs <wzw (TYP. OF 6) o Ei�m PROPOSED GALV. UNISTRUT W/ SS HARDWARE 12' DIPLEXER FRAME DETAIL N.T.S MECH. BOND TO PIPE, TVP. 12'0x36'D CONCRETE SECTOR EXISTING � DNA EXISTING NANiFNNA PROPOSED ANTENNA PER SECTOR EL (E) (P) EG 91A5-T COAX (CABLES REUSE COAX CABLES OWWN BAN. BAND ALPHA BSA-185025/12 X7CQAP-FRO-645-WO 1 24B'3E 0' 2 2 1 (1) 1 5/8' (2) 1 5/8' ALPHA BSA-185025/12 1 248'20' (2) 1 5/8' _ ALPHA X]C-FRO--940-4 _ _ - _X7CDAP-FRO-645-_VRO- —1._ . 248'f-0'._ _2_ _2_ _ (1) 1 5/8' (2) 1 5/8' BETA BSA-185055/12 2 DEG X]CQAP-665-VRO 1 248'20' 2 2 1 (1) 1 5/8' (2) 1 5/8' BETA BSA-185065/12 2 DEG 1 248'S40' (2) 1 5/8' BETA X]-665-4 X]COAP-665-VRO 1 248'i40' 2 2 (1) 1 5/8' (2) 1 5/8' GAMMA SSA-185065/12 2 DEG X]COAP-FRO-645-VRO 1 248@50, 2 2 1 (1) 1 5/8' (2) 1 5DEG 1 248't50' (2) 1 5/8' -440-4 X]COAP-FRO-645-VRO 1 248';50' 2 2 1) 1 5/8' KEEP 3 EXISTING LTE ANTENNAS AS PLACE HOLDER FOR LEASE PURPOSE ANTENNA AND COAX CABLE REQUIREMENTS �verizoWl 4700 EXCHANGE CT. SUITE 100 COCA RATON. FL M431 (561) 995-5500 PROJECT INFORMATION: WEST MIDWAY SITE No. 69032 16800 OKEECHOBEE ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY URRENT ISSUE DATE: FEBRUARY 2017 UED FOR: RET/4XRX UPGRADE cV..--DATF--====DESUKl PTION: SEAL: MWA1 Y IjIl 1..0.7 a �� W e Q� > orn t C 1 INIEY-H0.PN PND A$$OClA 1E$, IN4 1920 WEKIVA WAY WEST PALM BEACH. FLORIDA 33411 (567) 845-0665 FSPE CAMON96 ROJECT DATA: RAWN BY:=CHK.: APV.: RHO I MM MM CENSURE NWIXpO A MULES PE 70645 NARIA V. MARPN PE 7219E KENN K. NARAM PE 714M HEET TITLE: ANTENNA DETAILS HEET NUMBER: 4 OF 5 KHA Job #: 044290115 x a £ H a s a se e € g F a n e ¢ � § 5 S # 6 8 p a i n g PROPOSED CONFIGURATION laszss .� `r ... 'sue RF ENGINEERING ANTENNA SPECIFICATION SHEET New Service - New Antennas (Like -for -Like) ALPHA BETA GAMMA AntepaidQ�y0d1y. _ 0 0 0 A61eo-n AAt�e� _ __ _ - RecbmID9nded.Etecuic�D,o`�bTilE;(4egj _ _ . rd1t a NO NO NO 0 NO NO NO "0 NO NO NO Hybrid Cable (Fiber&Power) Co D Hybrid Cable (Fiber&Power) Hybrid Cable (Fiber&Power) D 0 C Sibs &'ENs 266 P.CS ,1900MHz ANTENNA' CONFIGURATIONS Existing Service -Antennas Unchanged ALPHA BETA GAMMA Antenna Quantity _--_- - _- 0 0 0 Antenna Model - X7CQAP-FRO-645-VR0 X7COAP-665-VRO X7CQAP-FRO-60,VR0 AntennaOrientation 70 140 250 Antenna Centerline:(feetAGL) --'- - 248 248 248 Recommended EleckiealDowd-Tilt(Deg.)— 2 2' 2 __ giplexed'Antenna YES YES YES _ DipluenModei ptpi� __ _-_-6 DBC-7CAP DBC-7CAP DEC-7CAP TMA'Model gly7' 0 NO _' NO NO Coa)ialiType -- 15B" 1518" 1518° Coaxial Quantity' -_--- - 2 2' 2 P,CS SitoNumben&'P,Ns �25fi - - LTE 700MHzANTENNA CONFIGURATIONS Existing Service - Antennas Modified ALPHA BETA GAMMA Antenna Quantity... _.. _ --- _ 2 2 2 Antenna Model' _ - - 1 _ _ _ = X7CQAP-FRO445-VR0 X7CQAP-665-VRO X7COAP-FRO.645.VRO Antenna Orientation 70 140 250 Antenna Centerline (feetAGL) 24B 248 248 Recommended Electrical DowmTgt(Deg.) `- _ 2 2 2 Oiplexed'Antenna _ ___- _ YES YES YES DiplexenModel Qty: _ 6 DBC-7CAP DBC-7CAP DBC-7CAP TMA Model, qry;-. _ - _ 0 NO NO NO Coaxial Type:. _-. _ 1518" 1518, 1518 ° ComdaTQuantity _ '_. __ �- 2 2 2 DUL Quantity LTE Site Number &PNs- ._. -- _146256 L'TE 2100 z,(AWS'ANT-NNA CONFN6 710.5 Existing Service -Antennas Modified ALPHA BETA GAMMA n .Oa.QuaOtity 0 0 AnteOnaJ;iodel � __ _ _ Antapna 0ueptitmn __ pn(enga Ceritcvlirie {feet RGL) Oe Reto�t0sde0d n b W I D'owji Tilt ---- - - ('I 1PIe%adrAp III, --_ NO NO NO biplexe oriel Q �� _ _-'0 NO NO NO TMA"Mo eI Qtyi � 0 NO NO NO ColkialiTil 1SRI" 1518" 1518" Coax@( QuanQry.-. 0 0 0 AWS Site Number;6'P,Ns _ W446256 _ . . /19DDT700 ANTENNA:Replace(6)Antennaswith(6) RETAntennas. Keep(3) existing LTE antennas as "dummy" antennas.Add 4xRxwIth Di lexers. COAX: Existing Coax Lines DIPLEXER: 12 Diplexers, (3) Commscope AISG Smart Bias -Ts COMMENTS: , & starting electrical downtift values for NET EQUIPMENT SUMMARY Metebegafkrfe 0 SITB. (1°OVMfIa) Tofai NurnggOof;Cosxlal: 0 iTotal Num6enofAntennas:— 0 eP,CS (1 900MHz)® _ LTE(700MHz) Total Numtierofcoaxial:1111111111111 -- Total Number of Coaxial: 6 Total Number of Antennas: -- 6 - 6 _ ota�NumbepofAntennas: 0 AVJS (2f00MHzJ 'Total Num6ev,of Coaxial: 0 -- TOTAL ANTENNA COUNT:_ 613LEASEONLYI.. - TOTAL TOTAL COAXIAL COUNT: - - -: _;_..- 12- ;CSLTEA1pb . NO P,C5 L�Ei(.9DOMH C*j iT.Goajdal:5""ize. Hybrid Cable (Fiber&Power) ®P,CSOiple%e YES ®PGS(190OMHz)� LTE(NOMHz) Coaxial LTE Coaxial Size: 1518" LTE DiplexW YES 1518" AWSDtPlaxed: NO _ _ AWS {2100MNz) COMBINER SETNEEDEDATBTS: _ - - - SAWS Cea10e Sixe; 1518" DBC-750(BTS Rack Mount Muldport) , NOTE: ANTENNA DIAGRAMS ARE BASED ON RFDS DATED 07-12-16 TOTALDIPLEXER COUNT: -'12_';- -_; v riz n 470 " NMW a.. WITE iae 30C RAttRy FL 33IJ1 (561) 995-5500 PROJECT INFORMATION: WEST MIDWAY SITE No. 69032 16800 OKEECHOBEE ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY CURRENT ISSUE DATE: FEBRUARY 2017 SSUED FOR: RET/4XRX UPGRADE EV. DATE: —DESCRIPTION: i •r + ri e.. OENS� °'• ���'r r _ s I�0. 72331 S"iA-[EO i 7 'Mley)))Horn © ]01] puLEY-X0.PN M'0..A1ES C. 1920 WFKIVA WAY WEST PALM BEACH, FLORIDA 33411 (567) 845-0665 FHPE CA0000s9s ROJECT DATA: RAWN BY:=CHK.: ARV.: RHO MM MM (CENSURE: P Dwo A AR¶1E5 PE 70615 NgWA V. MMPN PE 7097 KENN K. M~ PE T455 HEET TITLE VERIZON RFDS _j HEET NUMBER. 5 OF 5 KHA Job #: 044290115 I verionv VICINITY MAP 4700 EXCHANGE COURT — SUITE 100 BOCA RATON, FLORIDA 3343 1 WN,SETBACK REQ. PHONE (561) 995-5500 FRONT SIDES CNR DES VERIZON WIRELESS SITE NAME / GOZER NUMBER WEST M I DWAY/ # 69032 CROWN BU# 800642 16800 OKEECHOBEE ROAD FORT PIERCE, FL 34945 LATITUDE 27°22'53.30"N, LONGITUDE 80°29'48.40"W NAD 83 FROM V IZON OFFICE: HEAD SOUTH ON EXCHANGE CT TOWARD TECHNOLOGY WAY, TURN LEFT ONTO TECHNOLOGY WAY, USE THE RIGHT 2 LANES TO TURN RIGHT ONTO NW 51ST ST/YAMATO RD. TURN LEFT TO MERGE ONTO 1-95 N TOWARD W PALM BEACH. MERGE ONTO 1-95 N. TAKE EXIT 126 FOR COUNTY RD 712/MIDWAY RD. SHARP LEFT ONTO W MIDWAY RD. TURN LEFT ONTO FL-70 W. TURN RIGHT ONTO S HEADER CANAL RD, THE SITE WILL BE ON THE RIGHT. DRIVING DIRECTIONS THE SCOPE OF WORK CONSISTS OF MODIFYING THE EXISTING WRR FEE INSTALLATIONS: 1. REMOVE (6) EXISTING ANTENNAS 2. REUTILIZE (3) EXISTING ANTENNAS 3. REUTILIZE EXISTING (12) 1 5/5- COAX CABLES 4. INSTALLATION OF (6) NEW ANTENNAS 5. INSTALLATION OF (3) TOWER MOUNTED BIAS-T 6. INSTALLATION OF (6) TOWER MOUNTED DIPLEXERS (DEC-7CAP) 7. INSTALLATION OF (6) GROUND MOUNTED DIPLEfIERRS (DBC-7CAP) SCOPE OF WORK ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1. STH EDITION, 2014 FLORIDA BUILDING 6. AMERICAN INSTNTE OF SMEL CODE CUNSTRUOTOV SPECIRCATONS (AISC) Z NATIONAL ELECTRIC CODE (NEC) WTH 9. UNDERWRITERS LABORATORIES LOCAL AMENOMENTS LATEST GO. (U L) APPROVED ELECTRICAL S ANSI/RA/BA APPLICABLE STANDARDS PRODUCTS 4. UPS SAFETY MOE NMA-101-2015 8. LOCAL BUILDING CODE S 5TH EDITION. FLORIDA FIRE 9. CITY/COUNTY ORDINANCES PREYIIITON CODE 2014 CODE COMPLIANCE APPLICANTILESSEE MDCMC NAME: VERIZON 'WIRELESS PROJECT MANAGER: KATHY CICERO PHONE: 561-995-5590 PROPERTY INFORMATION TOWER OWNER: CROWN CASTLE INTERNATIONAL 6420 CONGRESS AVE SUITE 2000 BOCA RATON. FL 33487 HANDICAP REQUIREMENTS: FACILITY IS UNMANNED AND NOT FOR HUMAN HABITATION. HANDICAPPED ACCESS NOT REQUIRED. PARCEL ID: 3201-244-0039-DOD-e JURISDICTION: ST. LUCIE COUNTY PROJECT INFORMATION EQUIPMENT LOCATION: N OUTDOOR 0 INDOOR PROJECT SUMMARY CIVIL ENGINEER: KIMLEY-HORN AND ASSOCIATES, INC. 1920 WEKIVA WAY WEST PALM BEACH, FLORIDA 33411 MARIA MARTIN (561) 845-C665 STRUCTURAL ENGINEER: N/A ELECTRICAL ENGINEER: N/A SURVEYOR: N/A PROJECT TEAM FED . MAR 0 9 2017 PERMITTING St. Lucie County, FL SHEET DESCRIPTION REV. 1 COVER SHEET 0 2 SITE PLAN LAYOUT, ENLARGED PLAN AND NDTES 0 •J TOWER ELEVATON AND ANTENA ORIENTATION 0 4 ANTENNA DETAILS O 6 VERIZON RHOS 0 PLANS AND ALL-PR(),0c)3Ct) V,0T R DOM 4. J I A h +1 APPLICABLE C 9. SHEET INDEX ISSUED FOR: GET/4MX UPGRADE DATE: FEBRUARY 2017 DESIGN: -- 5TH-EDITION; 2014 FLORIDA BUILDING CODE BUILDING DIVIBION REVIEWED FOR COMPLI R :D BY__ V �Z 4709 EXCHANGE U.. SU11E l00 BOCA RATON. R W431 (561) 995-5500 WEST MIDWAY SITE No. 69032 16800 OKEECHOBEE ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY :CURRENT ISSUE DATE: FEBRUARY 2017 RET/4XRX UPGRADE No•1239� P) In © $OIJ gYfF 19HORN ANO ASSCLUIN[ 1920 WEKWAY FLORIDAFL WEST PALM BEACH, 33411 (561) 845-0665 RHO MM MM ARNIX00 A ARTIES PE 70645 MARIA V. MARTIN PE 7097 KENN X. KARAM PE 7105 COVER SHEET 1 OF 5 =KRA Job #: 044290115 IX X X X X /+' EXISTING GENERATOR ON CONCRETE PAD EXISTING FIBER HAND HOLE EXISTING EQUIPMENT SHELTER EXISTING ICE BRIDGE (TYP.) x x c EXISTING VERIZON WIRELESS ICE BRIDGE (TYP.) EXISTNG VERIZON WIRELESS EQUIPMENT ON CONCRETE PAD EXISTING EMPTY CONCRETE PAD EXISTING EQUIPMENT ON CONCRETE PAD EXISTING CHAIN LINK FENCE EXISTING ICE BRIDGE (TYP.) X 0 x EXISTING GENERATOR ON CONCRETE PAD X EXISTING SELF-SUPPORT TOWER C C X EXISTING EQUPMENT SHELTER X EXISTING ICE BRIDGE (TYP.) X —X X X XI SITE PLAN NORTH o s 12' SCALE FEET THESE PM8 AND ALL PROPOS "D WORK ARE SUBJECT TO ANY COPIREC T 2N3 REQUIRED BY FIELD INSPECTORS THAT NIAY BE NECESSARY IN O€IDER TO CJP,iPLf 111ITI-I ALL APPLICABLE CODE9. EXISTING VERIZON WRELESS EXISTING YERIZON WIRELESS CONCRETE PAD ICE BRIDGE (TYP.) EXISTING WIRELESS TEICONCABINET V 'Z J 470D EXCHANGE CT, SUITE 100 BOCA BATCH, FL 33431 EXISTING VTELCO (561) 99f 5500 WIRELESSTELcO CABINET PROJECT INFORMATION: o EXISTING VEAIZON WEST MIDWAY N1REIJ=SS AC PANEL SITE No. 69032 O O ® O 16800 OKEECHOBEE ROAD EXISTING VERIZON FORT PIERCE, FL 34945 WIRELESS DISCONNECT W/GEN PLUG BELOW S!. LUCIE .COUNTY II C i QA CURRENT ISSUE DATE: FEBRUARY 2017 SSUED FOR: RET/4XRX UPGRADE ENLARGED EXISTING VERIZON WIRELESS EQUIPMENT PLAN EV, DATE:===DESCRIPTION: LEGEND OA EXISTING VERIZON WIRELESS GENERATOR NORTH BO EXISTING VHRIZON WIRELESS GRAM � SEAL:X , © EXISTING VERIZON WIRELESS CDMA ON BRAIN U� OD EXISTING VERIZON WIRELESS 6101 CABINET Q�'GENSE•',1'��/`//� scALE FEET O PROPOSED (6) OIPLEJINS (DBCr7CAP) MOUNTm TO :' \/ •'', -� i PROPOSED RACK (SEE SHEET 4) EXISTING VERIZON WIRELESS // EXISTING WRIZON WRELESS ? \`30 J CONCRETE PAD O J >5f ICE BRIDGE (TYP.)EXSTING )) WIRELESS TENLICOCABINET i EXISTING VERIZON rLmYXo •o�.,...I GL �' w.f,�a WIRELESS TELCO CABINET wfl'ifll@��lorn o EXISTING VERIZON ©zBIR KrMLEl- ..0 A550CA ES, we WIRELESS AC PANEL 1920 WEKIVA WAY DO BO ® BO WEST PALM BEACH, FLORIDA 33471 EXISTING VERIZON (561) 845-0665 WIRELESS DISCONNECT fEPE CADOG0696 c W/GEN PLUG BELOW ROJECT DATA: 1 i Oi ENLARGED PROPOSED VERIZON WIRELESS EQUIPMENT PLAN' -DRAWN BY=CHK.: APV.: RHO MM MM CONSTRUCTION NOTES CENSURE: ARNOL00 A. ARTItES PE 70645 SCOPE OF WORK: FURNISH ALL LABOR, MATERIALS, TOOLS, SUPPLIES, EQUIPMENT AND MACHINERY NECESSARY TO MARIA v.'MAR➢N BE 72397 COMPLETE WE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. MATERIALS OR WORK DESCRIBED IN KEMN K MARAJH M 71455 WORDS WHICH HAYS A WELL KNOWN TECHNICAL MADE MEANING SHALL BE HELD TO REFER TO WE RECOGNIZED STANDARD. ALL MATERIALS SHALL BE NEW UNLESS OTHE RWISE SPECIFIED. CODES: ALL WORK PERFORMED AND MATERIALS USED SHALL MEET ALL REQUIREMENTS OF THE LATEST ADOPTED EDITION OF HEET TITLE' THE BUILDING CODE, STATE CODES, AND LOCAL CODES, ORDINANCES, AND REGULATIONS HAVING JURISDICTION. WE CONTRACTOR SHALL SECURE AND PAY FOR WE BUILDING PERMIT AND ALL REQUIRED OTHER PERMITS AND FEES, SITE PLAN LAYOUT, UCENSES, AND INSPECTIONS NECESSARY FOR WE PROPER EXECUTION AND COMPLETION OF WE WORK. WE EXISTING CONDITIONS SHOWN IS DIAGRAMMATIC AND BASED UPON WE BEST INFORMATION NLARGED PLAN AND NOTES AVAILABLE HOWEVER, MAY NOT REFLECT ALL FIELD CONDITIONS AT THIS TIME. WE CONTRACTOR SHALL VEIT THE SIZE AND BECOME FAMILIAR WITH THE EXISTING CONDNONS AND THE SHEET NUMBER' COORDINATION OF WE WORK. ANY OMISSIONS OR CONFUCT IN THE WORKING DRAWNGS OR BETWEEN WE DRAWINGS AND EXISTING FIELD CONDITIONS WHICH MAY INTERFERE WITH THE PROPER EXECUTION AND COMPLETION OF THE DESCRIBED WORK SHALL BE BROUGHT TO TILE ATTENTION OF THE ENGINEER PRIOR TO PROCEEDING WITH THE WORK. VERIFY ALL DIMENSIONS IN THE FIELD PRIOR TO BEGINNING WORK. THE CONTRACTOR SHALL IMMEDIATELY 2 OF 5 NOTIFY THE ENGINEER OF ANY DISCREPANCIES BETWEEN THESE PLANS AND EXISTING FIELD CONDITIONS. L STORAGE & INSTALLATION: ALL MATERIALS AND EQUIPMENT SHALL BE STORED AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS UNLESS OTHERWISE NOTED. �KHA Job #: TI PROTECTONS: PROTECT WTEMPORARY BARRICADES, COVERINGS, OR OTHER PROTECTIONS TO PREVENT INJURY OR 044290115 NOTE: THE CONTRACTOR SHALL VERIFY CAELES/REINFORCEMENT DAMAGE TO PERSONS OR PROPERTY. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REPAIRING ANY DAMAGE CAUSED BY LOCATION BEFORE ANY CONCRETE ANCHOR INSTALLATION HIS OPERATIONS. 7 i S X EXISTING VERIZON WIRELESS ANTENNA TO BE REMOVED (1 PER SECTOR) (3 TOTAL) NOTE: FCC REGISTERED HEIGHT W/APPURTENANCES 15 255' TOP OF TOWER w 245'2 A RAD CENTER OF EXISTING AND PROPOSED VERIZON ANTENNAS EL=24B't AGL EXISTING—/ tOR,DMOtN ANTENNAS TO BE REMOVED AND REPLACED TOP EXISTING VERIZON WIRELESS WITH (6) NEW ANTENNAS, EXISTING MOUNT MMP ANTENNA TO BE REMOVED TO REMAIN. O t (1 PER SECTOR) (3 TOTAL) P,y1MOM 250 EXISTING VHRIZON WIRELESS v EXISTING ANTENNA ANTENNA TO BE RELOCATED (I PER SECTOR) (3 TOTAL) MU N AOUNTZON TO� TO PI EXISTING ANTENNA OpMM Ct pSMUtM .50 Ct piWp" 1`� PROPOSED VERIZON WIRELESS BIAS-T PROPOSED VERIZON WIRELESS DIPUEXER PROPOSE (TYP. OF 2)� PROPOSED VERIZON WIRELESS ANTENNA � ib. PMM t p11MOM 1111F.TeiN_1di PROPOSED VERIZON WRELESS ANTENNA Gt g'% O p Np s oOpyMMN TO RELOCATED EXISTING VERIZON WRELESS PROPOSED VERIZON ANTENNA WRO-ESS ANTENNA ` \\ Np S,DDDP-L1MUN EXISTING 245' SELF-SUPPORT TOWER s EXISTING ANTENNA NOTE: PROPOSED VERIZON THIS DRAWING IS INTENDED TO DEPICT THE WIRELESS OWRIZOR GENERAL LOCATION AND HEIGHT OF THE WIRE OF DI PROPOSED LOADS ON THE EASING TOWER. CONSTRUCTION SHALL NOT PROCEED UNTIL ° RELOCATED EXISTING A STRUCTURAL OPINION LETTER HAS BEEN VERIZON WIRELESS PROPOSED VERIZON COMPLETED BY A PROFESSIONAL ENGINEER j ANTENNA WIRELESS BIAS-T REGISTERED IN THIS STATE., CONCLUDING THESk' P ANS,ApaDSTRUPn^o�9 1 THAT THE EXISTING TOWER IS ET ALL RO OSr T % p�tN ,C E STING ANDPROPOSEDLOADS.ADEQUATE TO SST THE ARE G{ 4CCT TO ANY 'r J VL' i 6 P 0 Yp, PROPOSED A�IZONNTENNA ..Jf3• r- , o $ 1r30 � WREIE55ANTENNA { VCI•,iiEC{11„1f R 4JIREll BY FILELE) INSp ECTOFj Tffr PROPOSED VERIZON 6TAY B'E r4EcE '� , R 5 WIRELESS ANTENNA MM v��Gl3 RELOCATED WIRELESS G .+Jp1 71 •,/ 1P ! T�'�1,:Y IN e PVMD ^Xll rl P�I{1'I AX.� !�f1 Vie.. VV A, F L}, 25O _-PROPOSED -VERIZON 3 WIRELESS (2) BIAS-T i PROPOSED VERIZON WRELESS ANTENNA J NOTES: PROPOSED VERIZON yL WIRELESS DIPLEXER TOWER ELEVATION 1. SAFETY CLIMB AND CUMBING PATH MAY NOT (TYP, OF 2) N.T.S. 8 BE OBSTRUCTED IN ANY WAY. i NOTE. 2. IF DEMATION FROM THE DESIGN IS REQUIRED, 1. ALL EA"NG k PROPOSED ATTACHMENTS TO TOWER BASED ON STRUCTURAL ANALYSS BY OTHERS. SUCH BUT NOT LIMITED TO THAT DIPLEXERS, BIA-YS, ETC. CANNOT BE INSTALLED AS 2. FOR CLARITY, EXISTNG GROUND EOUIPMENT FOR OTHER CARRIERS NOT SHOWN. DESIGNED BEHIND THE ANTENNAS THE VERIZON 3 WIRELESS CM IS TO CONTACT THE CROWN CM TO 1 CONTRACTOR TO COORDINATE ANTENNA MOUNTS W/ VERIZON CPM. - 3 CONFIRM BEST PATH FORWARD AND ENSURE THE ' S MA AS WELL AS THE SA ARE STILL CONSIDERED PROPOSED ANTENNA ORIENTATION DIAGRAM 4. CONTRACTOR TO REFER TO STRUCTURAL ANALYSIS (BY OTHERS) S PASSING' § N.T.S v riz 4700 EXCHANGE CT, STITE 100 90CA RATON. R 33431 (561) 995-5500 PROJECT INFORMATION: WEST MIDWAY SITE No. 69032 16800 OKEECHOBEE ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY CURRENT ISSUE DATE: FEBRUARY 2017 SSUED FOR: RET/4XRX UPGRADE EV.:=DATE:====:DESCRI PTION: SEAL unn,uu. INS 7 �10 STAT��� P d�f�i,��lorn C �1 qNp g550C1AlES INC 1920 WEKIVA WAY WEST PALM BEACH, FLORIDA 33411 (561) 845-0665 FHPE CAOOOOfi96 ROJECT DATA RAWN BY:=CHK.: APV.: RHO MM MM (CENSURE: ARNO DO A. ART6E5 PE 70645 MAMI V. MARTIN PE i2197 KEMN K. MARA,M PE 714M HEET TITLE• TOWER ELEVATION AND ANTENNA ORIENTATIONS HEET NUMBER: 3 OF 5 KHA Job #: 044290115 B M 700 wRi AWB/PCs �. gas bas 45 ANTENNA LAYOUT N.T.S. NOTE: ANTENNA DIAGRAMS ARE BASED ON RFD5 DATED 07-12-16 NOTE: 1. ADD (6) NEW ANTENNA. 2. VERIZON WIRELESS CURRENRY HAS (12) 1 5/8" COAXIAL CABLES INSTALLED. 3. ADD (3) BIAS-T 4. ADD (5) DIPLE%Efts 5. REQUEST CURRENT RROS BEFORE INSTALLATION. VERIZON WIRELESS ANTENNA PROPOSED ANTENNA BRACKET PROVIDED, W/ANTENNA -as M ANT} AWS/PCSAy ws ws PROPOSED PIPE MOUNTING BRACKETS PROVIDED W/ANTENNA (TYP-) PROPOSED ANTENNA TILT BRACKET PROVIDED W/ANTENNA MOUNTING PIPE PROPOSED ANTENNA MOUNTING DETAIL N.T.S SHELTER 270' GAMMA SECTOR (25 TRUE NORTH (o') 180, SECTOR (70') (14Q') CONTRACTOR SHALL USE SURVEY INFORMATION TO AUGN ORIENTATION OF ANTENNA SUPPORT STRUCTURE(S) WITH BEARINGS SHOWN IN DIAGRAM ABOVE. ANTENNA ORIENTATION DIAGRAM N T.S. EXISTING ICE BRIDGE POST MAX. BETWEEN VERPCAL EXISTING COAX MEMBERS SHHALL BE 40' A BRIDGE POST PROPOSED OIPLE%PRPOSE AP) MOUNTEp TO PROPPROPOSEDR RACK.(TYP. OF 6) A Em PROPOSED GALV. UNISTRUT W/ SS HARDWARE MECH. BOND TO PIPE. TYP. BOND TO EXIST.J y i GROUND RING �vDp' h, lNS AND ALL Pnoposco V� .-; CONCRETE J' AND K AIRE SUBJECT TO ANY C0 �44EC7iG� LJIn_U GY FIELD INPECTORS T!; F2i,aY 5E R?ECFSsA,DY IN ORDEN TO DIPLEXER FRAME DETAIL C:C11ITI-1AL APPUCAD. LECCU N.T.S SECTOR I TO BE EXISTINGANTENNA ETT RINGANTENNA TO PROPOSED ANTENNA PERSE SECTOR EL (E) AZ (P) AT BIAS-T (CABLES M Com CABLES LOW BANO HI BAND ALPHA BSA-185025/12 X7CQAP-FRO-645-VRO 1 248'3 70' 70' 2 2 1 1 (1) 1 5/8" (2) 1 5/8" ALPHA BSA-155025/12 1 248'2 7D' 70' (2) 1 5/8- ALPHA X7C-FRO-440-4 %7CQAP-FRO-645-WO 1 248'} 70' 70' 2 2 (1) 1 5/8" (2) 1 5/8- BETA BSA-185065/12 2 DEG X7CQAP-665-VRO e 1 248'3 140' 140' 2 2 1 (1) 1 5/8" (2) 1 5/8' BETA BSA-185065/12 2 DEG 1 248'3 140, 140' (2) 1 5/8" BETA X7-665-4 X7CQAP-665-VRO 1 248'2 140' 140' 2 2 (1) 1 5/8" (2) 1 5/8" GAMMA BSA-185065/12 2 DEG X7CQAP-FRO-645-VRO 1 248'3 250' 250' 2 2 1 (1) 1 5/8- (2) 1 5/8- GAMMA BSA-185065/12 2 DEG i 2484 250' 250 (2) 1 5/8" GAMMA X7C-FRO-440-4 X7COAP-FRO-645-WO 1 2a8't 250' 250' 1 2 2 (1) 1 5 KEEP 3 EXISTING LTE ANTENNAS AS PLACE HOLDER FOR LEASE PURPOSE ANTENNA AND COAX CABLE REQUIREMENTS v riz n 4700 EXCHANGE LT, loo 90LA RATION, (561) 995-5 3343 50000 WEST MIDWAY SITE No. 69032 16800 OKEECHOBEE ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY CURRENT ISSUE DATE: FEBRUARY 2017 RET/4XRX UPGRADE 2011 kINLEY-HQPN RNO ASSCLUIES INC 1920 WEKIVA WAY K/EST PALM BEACH, FLORIDA 33411 (561) 845-0665 DUPE GA0000696 RHO I MM MM ARNCUDC A ARTLES PE 70645 MARA V. MARTIN PE 72397 KEVIN K. MARAM PE 714M ANTENNA DETAILS 4 OF 5 =KHA Job #: 1 044290115 1 Y 8 x c p _ g 4 a 8 3 k 8 € p p a 9 7 -�Taa)Numba%o(Antapnas: A g £ PROPOSED CONFIGURATION 146256 i HI uC. PL,h,NPj ACID ALL Pt P -+❑ C OS)^C WCPi( AKSU0JECTTOANY V0111 RECtIOilJ; RLG JlY{CU oY PIi:LD IiIS3�,ECiG�,S T1 f.3T 1 7n � C.CENlAy LSE 1'?ISuFr:7�eY lkj Gtlu l't I!� P A APPLICABLE c.ABLE CC;'Eq" RF ENGINEERING ANTENNA SPECIFICATION SHEET L`TEIi FBI,iz"ANTENNA'CONBIGURA`[R1N.S New Service - New Antennas (Like -for -Like) ALPHA BETA GAMMA Antaona Quan. ___.. _ 0 0 0 Antehn3Mo" - - Antenna.0lrimtatioa _ - Acbm0,Cenkrgnilfe4t*GL) RCopmmartded Elodrioal DoYm riH( iIlllllllllllplll D1Ploacd'AnHnna _ -_-- NO NO NO Dlpla`tier;Mo q'Ji».----0 NO NO NO TMA111 _ :� 0 NO NO NO CoaxtallTy`pe Hybrid Cable Fiber&Power) Hybrid Cable FiberBPower Hybrid Cable (FiberBPower) - Ct11Sle Numbaf&:PNe 258 PCS 1900MHzANTENNA CONFIGURATIONS Exist ng Service - Antennas Unchanged ALPHA BETA GAMMA Antenna Quantity - 0 0 0 Antenna Model _ - X7CQAP-FRO-645.VRO X7COAP-665-VRO X7COAP-FR0.64SVR0 Antenna Orientation _ _ 70 140 250 Antenna Centerline feetAGL) _ - _ - 248 248 248 Recommended Electrical DowmTiit(Deg.) - - --- 2 2 2 Diplexed Antenna YES YES YES Diplexer Model Qly: --- --- -6 DBC-7CAP DBr TCAP DBC-7CAP TMA Model --0 NO NO NO Coaxial Type 1518" I BIB" 1 BIB' Coaxial Quantity - 2 2 2 PCS Site Number &PNs LTE 701 ANTENNA CONFIGURATIONS Existing Servlce - Antennas Modified ALPHA BETA GAMMA Antenna Quantity _ 2 2 2 Antenna Model X7CCAP-FRO-645-VR0 X7COAP-665.VRO X7COAP-FRO-64SVR0 Antenna Orlentaflon 70 140 250 Antenna Centerline (feet AGL) 248 24B 248 Recommended Electrical Dow Tilt (Deg.) 2 2 2 Diplexed Antenna - YES YES YES Diplaxer Model-_ _ 6 DBC-7CAP DBC-7CAP DBC-7CAP TMA Model _ QI _.- 0 NO NO NO Coaxial Type _ 1518" 1518" 1518" Cwxial Quantity _ 2 2 2 DUL Quantity. _ Qty: II I LTE Site Number& PNs 1 146256 _ Existing Service -Antennas Modified LTE 2100MHz AWS)'ANTENNA 'CONFIGURATIONS ALPHA BETA GAMMA Antenna quantity - --- - 0 0 0 Anterum Model 'Antenna Orientation Antenna Centerline(feet AGU) Recommended Electrical Downjut(Deg, _ - Diplezed'Anterm - - -- NO NO NO Diplaxer;Model 0 NO NO NO TMA'Modsl� 0 NO NO NO CoaaialiT pe -- 1518" 1 SIB" 1518" Conial.Quantf 111111110 1 -_ _ 0 0 0 DUL'Quant.. AWSSita Number,S, PNs 1111�446256 TECH TYPE: n90DN001 ANTENNA: Replace(6)Antennas with (6)RET Antennas. Keep(3) existing LTE antennas as "dummy" antennas. Add 4zRx with Diplexers. COAX: Existing Coax Lines DIPLEXER: 12 Diplexers,(3) Commsca eAISG Smart Bias -Ts COMMENTS: ,& starling electrical downtilt values for RET EQUIPMENT SUMMARY — D —PCS LTE09008IHt) PCS 1900MHz Total Nurrilier;oFCaaxkl; -- Total Number afAntennas: 0 Total Number of Antennas: 6 _ LTE((700MHz)) Total Number of Coaxial: 6 iTota1Number ofAmmrnasI 0 �AWS.(210OMliz)—iTot5l TOTAL Numberoof Coazlal:® - TOTAL COAXIAL COUNT: 0 TOTALANTENNA COUNT: _ 613 LEASE ONLY] 12 PCS;LTED , _ fd; NO P.CS'LTE.(1g00MHX C -w'cm xlalSasi Hybrid Cable (Flber&Power) PCS Diplexed: YES PCS (1900MHz) - _ PCS Coaxial Size: _ 1 Sr8" _ LTE Diplexed: YES LTE (700MHz)- _ LTE Coaxial Som: - 1518 ° FAWS Diplexed:�. NO �AWS(210OMHfSffi0lllllllllllAWS,Coaxial Siie:llllllllllllllllll� 1518" IN DIAGRAMS ARE BASED ON RFDS DATED 2-16 "TOTAL OIPLEXERCOUNT: 12 - -COMBINER SETNEEDEOATBTS: DBC- 750(BTS Rack Mount Multipart) V IZ 4700 EYC MR CT. SLIM 100 SOCA RATON. FL 33431 (561) 995-5500 PROJECT INFORMATION: WEST MIDWAY SITE No. 69032 16800 OKEECHOBEE ROAD FORT PIERCE, FL 34945 ST. LUCIE COUNTY CURRENT ISSUE DATE: FEBRUARY 2017 SSUED FOR: RET/4XRX UPGRADE EV.:ZDATE:ESCRIPTION: L No.72397 ' S�/T..ATE OF l i ey*Horn © 2017 TINLEl- . ANO ASSOLIA iES ING 1920 WEKIVA WAY WEST PALM BEACH, FLORIDA 33411 (561) 845-0665 FSPE CA0000696 ROJECT DATA: RAWN BY:=CHK.: API RHO MM MM CENSURE: A1LNIX➢O & ARTUS PE 70641 WM A V. V ARTN PE 7339) KE I4 K. V.AM PE 714M HEET TrrLE: VERIZON RFDS _]l HEET NUMBER: 5 OF 5 KHA Job #: 044290115