HomeMy WebLinkAboutPLANSCONTRACTOR: Jensen Beach Aluminum. DESIGN CRITERIA: 1. The 5th Edition (2014) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. ASCE 7-10. Wind Loads 1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5: Risk Category 2. 2. Basic Wind Speed, Table 1609C, State of Florida Debris Region & Basic Wind Speed, Paragraph 1609.3.11609.3.1 Equivalent Basic Wind Speed: Vm r =*an, VmD =132 MPH 3. Exposure Category, Paragraph 1609.4. Scope of Work: 1. Replacement of (2) Impact Sliding Glass Doors And (3) Impact Rated Windows. 2. Windows not within 20.0 ft of building comers. Builder / Permit Application is to provide Florida Product Approvals meeting required design pressures. WIND SPEED AND EXPOSURE HAVE BEEN DETERMINED USING THE ADVANCED TECHNOLOGY COUNCIL'S WEBSUE AND GOOGLE EARTH. OPENING SCHEDULE MARK SIZE (W"xH") MANUFACTURER SERIES # APPROVALS DESIGN PRESSURES ALLOWABLE STRESS M AM SFf-Z00' Faa 2' r1rAq PSF 80.0/-80.0 PSF 44" x 6 PGT H L23 -R 7 / 6• .0 SF 80.0/-80.0 PSF 144" 96"A RMT SG 770-3}ySI L 8 6�-3Z,*-5r'2 SF 60.0/-90.0 PSF FL24• - 9 5/ 6�1 PSF 68.2/-68.2 PSF ,5 51EB 8 -60!8 P 60.0/-90.0 PSF 6GANNED BY St. Lucie County z LLJ J J O WLLM^ U K�a^ '^_.0 Z (D g g�. to W F11�§ N K W C3 0 QO ¢U t- = W W V)W z� 0m N u l J C. u- KN _ 02/23/17 SHEUNO: A-1