HomeMy WebLinkAboutPLANS35 LF 12 ,; CONIC.
BEAM (TYP.) � CEILING BOARD
'12"O CONCRETE
\COLUMN (TYP.)
POSSIBLE—
COL/BEAM
FAILURE
EXPOSED
REBAR
(ROOF)
PP
- -- -
C- PP
emu- T
D
PP
LHS'
C.
--
-C
_C
-C
C3
E,3
-c
22' U.N.O. 4 4 10'-U"
F LE" C (0 PY
CARPORT B _
SCALE: 1/16" = 1'-0" z
SCOPE OFWORK: REMOVE UNSOUND STUCCOAND CONCRETEATDAMAGEDAREASPER DETAILS FOLLOWINTERNA770MAL CONCRETERESTORA770i
INSTITUTES RECOMMENDATION AND DETAILS ON THE PLANS. WATERPROOF THE TOP OF THE CONCRETE DECK FINISH TO MATCH EXISTING BUILDING.
DESIGN CRITERIA AND LOADS:
1. WIND DESIGN:
WIND SPEED (MPH)
V(ADJ)=124 V(UL7)=160
RISK CATEGORY
11
EXPOSURE CATEGORY
D
ENCLOSURE CLASSIFICATION
ENCLOSED
INTERNAL PRESSURE COEFFICIENT
CPI-�F 0.1H
TOPOGRAPHICFACTOR
KZT=1.0
GENERAL REQUIREMENTS
L PLANAND DETAIL N07ESAND SPECIFIC LOADING DATA PROVIDED ON INDIVIDUAL PLANS AND DETAIL DRAWINGS SUPPLEMENTS IMFORMA710MIN THE
STRUCTURAL GENERAL NOTES.
2 THE DESIGN AND CONSTRUCTION OF THIS PROJECT IS GOVERNED BYTHE 'FLORIDA BUILDING CODE (FBC)', FIFTH EDITION, HEREAFTER REFERRED TO
AS THE FBC, AS ADOPTED AND MODIFIED BY THE AUTHORITY HAVING JURISDICTION (AHQ.
3. WHERE OTHER STANDARDS ARE NOTED IN THE DRAW/NGS, USE THE LATESTEDIT/ON OF THE STANDARD UNLESS SPECIFIC DATE IS INDICATED.
REFERENCE 70A SPECIFIC SEC77ONINA CODE DOES NOT RELEVE 7HE CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE STANDARD.
A THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING DETAILS AND ACCURACY OF THE WORK WITH ENGINEERS, FOR CONFIRMING AND
CORRELATING ALL QUANNNES AND DIMENSIONS' FOR SELECTING FABRICATION PROCESSES FOR TECHNIQUES OF ASSEMBLY,AND FOR PERFORMING
WORKINASAFEAND SECUREMANNER
5. IN CASE OF DISCREPANCIES BETWEEN THE GENERAL NOTES, SPECIFICATIONSPLAWDETAILS REFERENCE STANDARDS THE ENGINEER SHALL
DETERMINE WHICH SHALL GOVERN.
& THE STRUCTURAL DRAWINGS ARE INTENDED TO SHOW THE GENERAL CHARACTER AND On ENT OF THE PROJECTAND ARE NOT INTENDED TO SHOW
ALL DETAILS OF THE WORK ARCHITECTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL DIMENSIONS.
7. ALTERNATE PRODUCTS OF SIMILAR STRENGTH, NATURE AND FORM FOR SPECIFIED ITEMS MAY BE SUBMITTED WITH ADEQUATE TECHNICAL
DOCUMENTATION TO THE ARCHITECDENGINEER FOR REVIEW. ALTER&TEMATER/ALS THATARE SUBMITTED MTHOUTADEQUATE TECHNICAL
DOCUMENTATION THATSIGNIFICANTLYDEVIATEFROM THEDESIGNINTENTOFMATER/ALS SPECIFIED MAYBERETURNED WNHOUTREWEW.
ALTERNATES THATREQUIRESUBSTANNAL EFFORTTOREV/EW MLLNOT BEREWEWED UNLESSAUTHORT/FD SYTHEOWNER
& DISCREPANCIES OMISSIONS OR INCONSISTENCIES WIIHAPPLICABLE CODEREQUIREMENTSSHALL BEBROUGHTTO THEATTENTIONOF THE
ARCHITECTIFWGINEER IN WRITING BEFORE SUBMIMNG A BID OR PROCEEDING WITH THE WORK
9. THE CONTRACTOR SHALL VERIFYALL DIMENSIONSAND CONDITIONS AT THE SITE CONFLICTS BETWEEN THE DR41WNGS AND ACTUAL SITE CONDITIONS
SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING BEFORE PROCEEDING WITH THE WORK
10. THE CONTRACTOR IS RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE STRUCTURE DURING CONSTRUCITONAND SHALL PROVIDE
TEMPORARY SHORING, BRACING AND OTHER ELEMENTS REQUIRED TO MAINTAIN STABILITYUN77L THE S TRUCTURE IS COMPLETE DO NOT LOAD
STRUCTURES, NEW ORSGSTINB, WITH WEIGHT THAT KILL ENDANGER STRUCTURE IT IS THE CONTRACTOR'S RESPONSIBILITY TO BEFAM/LIAR WIN
THE WORK REQUIRED IN THE CONSTRUCTION DOCUMENTS AND THE REQUIREMENTS FOR E)ECU77NG IT PROPERLY.
STRUCTURAL CERRFICA770N
1. 1 CER77FYTHAT THE PLANS AND SPECIFICATIONS COMPLY WITH THE STRUCTURAL PORTION OF THE FLORIDA BUILDING CODE FIFTH EDITION.
2 I ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROWDEADEQUATE RESISTANCE TO THE WIND LOADS SPECIFIED IN
SECTION 1609INTHEFBC.
LEGEND:
—CR— CRACK IN BEAM
—C — CRACK IN COLUMN
— U CRACK IN BOTTOM OF SLAB
PP PEELED PAINT
THESE PLANS AND ALL PROPOSCD Ve OR;:
ARE SMECT TO ANY C011REC T ICNS
—R OL'IRED BY FIELD INSPECTORS THAT
I AY BE NECESSARY 1.11 OiTDEK TG
CJ':l! Lt WITH H ALL A"P LIC1.
N ILE CUM&
�uANNED
BY
► -ucie County
6' THICK PRE -CAST
CONCRETE SLAB(TYP.)
CARPORTB
20'-9' --n- 'V 40'-6'
SITE MAP
SCALE: 1132'=1W NORTH
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COMEWANCEI
REVIEWED BY
DATE r, 2-z4 /7 A
MUST BE KEPT ON dbB OR
NO INSPECTION WILL BE MADE
\CENs,
No. 61000
STATE OF
" ORM' -.
_'TONAL ?*
wfH
1'
Z
IM W
COLUMN DELAMINATIONS
REPAIR
REPAIR PROCEDURE:
EXISTING CONDITIONS
1. SHORE STRUCTURE TO RELIEVE LOAD FROM COLUMN
SEVERE SPALL
AS MUCH AS POSSIBLE.
2. REMOVE ALL DAMAGED OR UNSOUND CONCRETE
FOLLOWING THE COND17IONING OF CONCRETE
GUIDELINES.
3. SAWCUT THE PERIMETER OF THE REPAIR AREA
FORMING A SHOULDER PERPENDICULAR TO THE
SUBSTRATE.
4. THE WR71CAL AND HORIZONTAL SURFACES SHALL BE
ROUGHENED WITH #" AMPLITUDE.
STEP 1
5. SANDBLAST OR HYDROBLAST THE EXPOSED CONCRETE
AND REBAR TO REMOVE DUST, LAITANCE AND 07HER
r AROUND
BOND INHIBITING MATERIALS. AVOID DAMAGING OR
TER OF SPALL
CUTTING EXIS77NG REINFORCEMENT.
6. INSERT NEW BARS OF EQUAL DIAMETER NEXT TO
THOSE THAT HAVE DETERIORATED BY MORE THAN 159
)NCRETE OUT TO
ALL NEW STEEL SHALL BE ASTM A-615 GRADE 60.
CONCRETE AND
LAP SPLICES SHALL BE IN ACCORDANCE WITH ACI 318.
STEEL TO PRODUCE
METAL FINISH.
Z COAT ALL NEW AND EXISTING REBAR WITH TWO 10 MILS
OF EPDXY, POLYMER CEMENT SLURRY OR A ZINC -RICH
COATING FOR CORROSION PROTECTION. INSTALLATION
SHALL BE DONE FOLLOWING THE MANUFACTURER
SPECIFICATIONS.
8. THE BONDING AGENT SHALL BE INSTALLED AS
DESCRIBED IN THE MANUFACTURER SPECIFICATIONS
z
TO SSD CONCRETE SURFACE.
SURFACES
9. FILL THE EXCAVATION WITH REPAIR MORTAR OR READY
AND
MIX CONCRETE PLACED AS DESCRIBED IN THE
)N AGENT.
MANUFACTURER SPECIFICATIONS.
10.REPAIR MIX SHALL HAVE A COMPRESSIVE RESISTANCE
OF 5,000 PSI AT 28 DAYS AND A WATER CEMENT
RA710 OF 0.45 OR LESS OR HAVE NON -SHRINKABLE
PROPERTIES.
11. FINISH SURFACE TO TEXTURE AND SM007HNESS
STEP 3
REQUIRED FOR THE SPECIFIC APPLICATION.
-FILL PREPARED AREA
12. PROVIDE THE ARCHITECTURAL FINISH AS REQUIRED BY
WITH REPAIR MORTAR
THE OWNER.
13. FOR MATERIAL SELECTION, PHYSICAL PROPERTIES,
STEP 4
MIXING, APPLICATION AND CURING INFORMATION REFER
-
TO APPROPRIATE TECHNICAL
DR07ECT SURFACE WITH
SPECIFICATIONS FROM
APPROPRIATE COATING
MANUFACTURER.
THESE E! ANIS AND ALL P' OPOar'd WORK
ARE SUUMT TO ANY CORRECT !CINS
R=OUIRE1) BY Fi LD 1RSFECTORS T1I AT
MAY mdE NECGSSAIR, Y IN 0R0ER T v
CO "i:f VJITI'I ALL AP
,�l E C0"MS.
EXPOSING AND UNDERCUTTING
OF REINFORCING STEEL
THESE DETAILS ARE APPLICABLE TO HORIZONTAL, VERTICAL AND
OVERHEAD LOCATIONS. THEY ARE ALSO APPLICABLE TO REMOVAL BY
HYDRO -DEMOLITION, HYDRO-MILLLING, AND ELECTRIC, PNEUMATIC OR
HYDRAULIC IMPACT BREAKERS.
1. REMOVE LOOSE OR DELAMINATED CONCRETE ABOVE CORRODED
REINFORCING STEEL.
2. ONCE IN171AL REMOVALS ARE MADE, PROCEED WITH THE
UNDERCUTTING OF ALL EXPOSED CORRODED BARS. UNDERCUTTING
WILL PROVIDE CLEARANCE FOR UNDER BAR CLEANING AND FULL BAR
CIRCUMFERENCE BONDING TO SURROUNDING CONCRETE, AND WILL
SECURE THE REPAIR STRUCTURALLY. PROVIDE MINIMUM J/ INCH
(19 MM) CLEARANCE BETWEEN EXPOSED REBARS AND SURROUNDING
CONCRETE OR % INCH (6MM) LARGER THAN LARGEST AGGREGATE IN
REPAIR MATERIAL, WHICHEVER IS GREATER.
3. CONCRETE REMOVALS SHALL EXTEND ALONG THE BARS TO
LOCATIONS WITH MINIMUM SIX INCHES FREE OF BOND INH1817ING
CORROSION, AND WHERE THE BAR IS WELL BONDED TO
SURROUNDING.CONCRE7E
4. IF NON -CORRODED REINFORCING STEEL IS EXPOSED DURING THE
UNDERCUTTING PROCESS, CARE SHALL BE TAKEN NOT TO DAMAGE
THE BARS BOND TO SURROUNDING CONCRETE. IF BOND BETWEEN
BAR AND CONCRETE IS BROKEN, UNDERCUTTING OF THE BAR SHALL
BE REQUIRED,
5. ANY REINFORCEMENT WHICH IS LOOSE SHALL BE SECURED IN PLACE
BY TYING TO 07HER SECURED BARS OR BY 07HER APPROVED
METHODS.
\\CENS 7
No. 61000
STATE OF
'� ORID '
'TONAL �Nc
z
O
wt=vi
J
z0j
Uf_w
U W
w
SLAB WATER PROOFING
SLAB FULL DEPTH REPAIR
ADDITIONAL TOP COATS
TOP COAT WITH AGGREGATE TO REFUSAL
BACKROLLED INTO WET TOP COAT
BASE COAT
SUBSTRATE. CONCRETE OR LEVELING OVERLAY
:aNG GUARD RAILS, SET BOTTOM RAIL 1/4" MIN.
OFF DECK TO ALLOW WATER FLOW OFF DECK.
REPAIR PROCEDURE.
PRODUCTS SHALL BE SIKAGARD FLEXCOAT SYSTEM UNLESS N07ED OTHERWISE.
ALLOW CONCRETE DECKS TO DRY FOR 48 HOURS MINIMUM WITHOUT RAINFALL.
CONCRETE MUST BE VISIBLY DRY WITH MAXIMUM 47. MOISTURE CONTENT. IF REQUIRED
BY THE ENGINEER, A MAT TEST SHALL BE PERFORMED ON ONE OR MORE DECKS
PRIOR TO BASE COAT APPLICATION. TEST SHALL COVER AN AREA OF FOUR SQUARE
FEET, MAT SHALL BE A 6 MIL CLEAR POLYURETHANE SHEET, SEALED ALL AROUND WITH
ADHESIVE TAPE AND IT SHALL REMAIN IN PLACE FOR A MINIMUM OF 16 HOURS.
CONCRETE DECKS SHALL BE DRY, CLEAN, SOUND AND FREE OF ALL CONTAMINANTS
WHICH MAY INTERFERE WITH ADHESION OR PROPER CURING.
2. APPLY BASE COAT TO TOP OF SLAB AND VERTICAL EDGES PER MANUFACTURER'S
SPECIFICATIONS AND ALLOW IT TO CURE BEFORE TOP COAT APPLICATION. EXTEND
APPLICATION TO VERTICAL EDGE OF SLAB AND TO DRIP EDGE IF APPLICABLE.
3. AFTER SUFFICIENT CURE TIME, SURFACE DEFECTS SHALL BE REMEDIED, CONTRACTOR
SHALL BE RESPONSIBLE FOR CORRECTING PONDING AREAS WITH COATINGS 3/16" OR
LESS. ALLOW IT TO CURE FOR 72 HOURS MINIMUM BEFORE OPENING THE BALCONY TO
TRAFFIC. TOP COAT APPLIED PER MANUFACTURER'S SPECIFICATIONS. BROADCAST SILICA
SAND IMMEDIATELY INTO THE WET TOPCOAT AND BACK ROLL TO EVENLY DISTRIBUTE
THE AGGREGATE. TOP COAT TO BE COMPATIBLE WITH BASE COAT.
4. APPLY FINAL TOP COATS PER MANUFACTURER'S INSTRUCTIONS.
THU-E PL AN$ AND ALL PROPOSr7 1AICIRR
ARE SU9JE'CT TO ANY COnRECTICHS
R-EOUIRED BY FIELD WSPECTORS THAT
I'AAY /P.EI►,IECESSA PaY IN CrRDEri T 0C'J!�.IPL V-11 I H Ai' A7, �L►CASL C CMES.
►.T�J.V:r••�d�Iy�r19:T�
a
py
1. REMOVE ALL DAMAGED OR UNSOUND CONCRETE
FOLLOWING THE CONDITIONING OF CONCRETE
GUIDELINES.
Ott
2. SAWCUT THE PERIMETER OF THE REPAIR AREA
FORMING A SHOULDER PERPENDICULAR TO THE
SUBSTRATE.
EXISTING CONDITIONS 3. CHIP OUT THE FULL DEPTH. REMOVAL SHALL
CONTINUE ALONG THE LENGTH OF THE
SEVERE SPALL
REINFORCING STEEL UNTIL AT LEAST 6" OF THE
UNCORRODED REBAR IS OBSERVED.
4. THE VERTICAL AND HORIZONTAL SURFACES SHALL
STEP I
BE ROUGHENED WITH }" AMPLITUDE.
SAWCUT AROUND
5. SANDBLAST OR HYDROBLAST THE EXPOSED
PERIMETER OF SPALL
CONCRETE AND REBAR TO REMOVE DUST,
LAITANCE AND OTHER BOND INHIBITING MATERIALS.
AVOID DAMAGING OR CUTTING EXIS77NG
REINFORCEMENT.
CHIP CONCRETE OUT TO
SOUND CONCRETE AND
6. INSERT NEW BARS OF EQUAL DIAMETER NEXT TO
CLEAN STEEL TO PRODUCE
THOSE THAT HAVE DETERIORATED BY MORE THAN
A WH17E METAL FINISH.
15% ALL NEW STEEL SHALL BE ASTM A-615
GRADE 60. LAP SPLICES SHALL BE IN
ACCORDANCE W1771 ACI 318.
7. COAT ALL NEW AND EXISTING REBAR WITH TWO 10
STEP 2
MILS OF EPDXY, POLYMER CEMENT SLURRY OR A
ZINC -RICH COA7ING FOR CORROSION PROTECTION.
COAT EXPOSED SURFACES
INSTALLA77ON SHALL BE DONE FOLLOWING THE
M7H APPROVED BONDING
MANUFACTURER SPECIFICATIONS.
AND AN71-CORROSION
AGENT.
8. 714E BONDING AGENT, IF REQUIRED, SHALL BE
INSTALLED AS DESCRIBED IN THE MANUFACTURER
SPECIFICATIONS.
STEP 3
9. FILL EXCAVA71ON WITH APPROPRIATE REPAIR
MORTAR, CONSOLIDA7E, FINISH AND CURE. REPAIR
FILL PREPARED AREA WI7H
MORTAR OR READY MIX CONCRETE SHALL BE
REPAIR MORTAR.
PLACED AS DESCRIBED IN THE MANUFACTURER
SPECIFICATIONS. REPAIR MIX SHALL HAVE A
COMPRESSIVE RESISTANCE OF 5,000 PSI AT 28
STEP 4
DAYS AND A WATER CEMENT.RATIO OF 0.45 OR
LESS.
PROTECT SURFACE V47H
APPROPRIATE COA7ING.
10. FINISH SURFACE TO TEXTURE AND SM007HNESS
REQUIRED FOR THE SPECIFIC APPLICATION.
11. UPON COMPLETION OF FINISHING OPERATIONS,
ALLOW MATERIAL TO CURE IN ACCORDANCE WITH
MANUFACTURERS S
RECOMMENDA710NS.
12 PROWDE THE
ARCHITECTURAL FINISH AS iVlu 9i
REQUIRED BY THE OWNER. ,�� Q. \CENSF'
* r' No.61000
STATE OF
FCOR0'
70NAL E
w
z
0
'm
w
z
w
N �O
�mwa>-m
°w
ZUSW UW�
owaexe9
1000 UON
f
_BEAM OR JOIST SPALLS: MODERATE
CONCRETE BEAM OR JOIST SPALLS: SEVERE
EXISTING CONDITIONS
MODERATE SPALL
(SEE N07E 1)
STEP i
SAW CUT AROUND
PERIMETER OF SPALL
CHIP OUT TO
SOUND CONCRETE
(SEE N07E 2)
STEP 2
COAT EXPOSED SURFACE
WITH BONDING AND ANTI-
CORROSION AGENT.
STEP 3
FILL PREPARED AREA WITH
REPAIR MORTAR
(SEE NOTE 6)
STEP 4
PR07ECT SURFACE WITH
APPROPRIATE COATING
(SEE NOTE 7)
NOTES.-
1. MODERATE SPALL DEEPER THAN ;"
(7MM) WITH SOME AGGREGATE LOSS,
BUT NO EXPOSED RE -BAR.
2. REMOVE ALL DAMAGED OR UNSOUND
CONCRETE.
3. THE EXPOSED SURFACES SHALL BE
ROUGHENED WITH 4• AMPLITUDE.
4. PRESSURE WASH AFTER EXCAVATION
TO REMOVE DUST, LAITANCE, AND
OTHER BOND INHIBITING MATERIALS,
SSD (SATURATED -SURFACE -DRY)
SUBSTRATE.
5. APPLY A 20 MIL COA71NG OF
BONDING AND AN77-CORROSION
AGENT ONTO THE PREPARED SSD
SURFACE TO INSURE PROPER BOND
OF THE REPAIR MATERIAL.
6. FILL EXCAVATION W17H APPROPRIATE
REPAIR MORTAR, CONSOLIDATE, FINISH
AND CURE. REPAIR MORTAR OR
READY MIX CONCRETE SHALL BE
PLACED AS DESCRIBED IN THE
MANUFACTURER SPECIFICATIONS.
REPAIR MIX SHALL HAVE A
COMPRESSIVE RESISTANCE OF 5,000
PSI A T 28 DAYS AND A WATER
CEMENT RA710 OF 0.45 OR LESS.
7. APPLY PR07EC71VE WATERPROOF
COATING TO PREPARED SUBSTRATE.
8. PROVIDE THE ARCH17ECTURAL FINISH
AS REQUIRED BY OWNER.
EXISTING CONDITIONS
SEVERE SPALL
STEP 1
SAW CUT AROUND
PERIMETER OF SPALL
CHIP OUT TO
SOUND CONCRETE
AND CLEAN STEEL
TO PRODUCE A
WHITE METAL FINISH
TEP 2
OAT EXPOSED
URFACE WITH
'ONDING AND
N77-CORROSION
GENT.
STEP 3
FILL PREPARED
AREA WITH
REPAIR MORTAR
STEP 4
PROTECT SURFACE
WITH APPROPRIATE
COATING .
NOTES.-
1. SEVERE SPALLS ARE DEEPER THAN }' (7MM) WITH AGGREGATE
LOSS, AND EXPOSED RE -BAR.
2. REMOVE ALL DAMAGED OR UNSOUND CONCRETE FOLLOWING THE
CONDITIONING OF CONCRETE GUIDELINES.
3. SAWCUT THE PERIMETER OF THE REPAIR AREA FORMING A
SHOULDER PERPENDICULAR TO THE SUBSTRATE.
4. THE VERTICAL AND HORIZONTAL SURFACES SHALL BE ROUGHENED
WITH 4° AMPLITUDE.
5. SANDBLAST OR HIDROBLAST THE EXPOSED CONCRETE AND REBAR
TO REMOVE DUST, LAITANCE AND OTHER BOND INHIB17ING
MATERIALS. AVOID DAMAGING OR CUTRNG EXISTING
REINFORCEMENT.
6. INSERT NEW BARS OF EQUAL DIAMETER NEXT TO THOSE THAT
HAVE DETERIORATED BY MORE THAN 157. ALL NEW STEEL SHALL
BE ASIM A-615 GRADE 60. LAP SPLICES SHALL BE IN
ACCORDANCE WITH ACI 318.
Z COAT ALL NEW AND EXIS71NG REBAR WITH TWO 10 MILS OF EPDXY,
POLYMER CEMENT SLURRY OR A ZINC -RICH COA71NG FOR
CORROSION PROTECTION. INSTALLA71ON SHALL BE DONE FOLLOWING
THE MANUFACTURER SPECIFICATIONS.
8. THE BONDING AGENT SHALL BE INSTALLED AS DESCRIBED IN THE. -
MANUFACTURER SPECIFICATIONS TO SSD (SA TURA 7ED-SURFACE-
DRY) CONCRETE SURFACE
9. FILL THE EXCAVATION WIIH REPAIR MORTAR OR READY MIX
CONCRETE PLACED AS DESCRIBED IN THE MANUFACTURER
SPECIFICATIONS REPAIR MIX SHALL HAVE A COMPRESSIVE
RESISTANCE OF 5,000 PSI AT 28 DAYS AND A WATER CEMENT
RA710 OF 0.45 OR LESS
10. FINISH SURFACE TO TEXTURE AND SMOOTHNESS REQUIRED FOR
THE SPECIFIC APPLICATION.
11. UPON COMPLE71ON OF FINISHING OPERA DONS, ALLOW MATERIAL TO
CURE IN ACCORDANCE K17H MANUFACTURERSS RECOMMENDATIONS.
14. APPLY PROIEC71VE WATERPROOF COATING TO PREPARED
SUBSTRA7E
15. PROVIDE THE ARCHITECTURAL FINISH AS REQUIRED BY THE OWNER.
16. FOR MATERIAL SELECTION, PHYSICAL PROPERTIES, MIXING,
APPLICA7ION AND CURING INFORMATION REFER TO APPROPRIATE
TECHNICAL SPECIFICATIONS FROM MANUFACTURER.
TNi.SE PsrhilS Ai1Q Ai.L RF?OAOSL"r7 WGBia
ASS: SUBJECT TO ANY CORRECT VIS
F'CUIFIEDByFIELD If1SPECTORSTHAT
BE NECESSA -W IN OF3Ccti T Cr
CO ,PLS' WITH ALL A; ;'- UC DLECGiMS.
\CENSF'
No. 61000
STATE OF
ORO%
OVERHEAD CONCRETE SPALLS: MODERATE
KISTING CONDITIONS
ODERATE SPALL
EP 1
W CUT AROUND
RIME7ER OF SPALL
°2
T EXPOSED SURFACE
BONDING AND ANTI-
ROSION AGENT.
STEP 3
FILL PREPARED AREA WITH
REPAIR MORTAR
STEP 4
PROTECT SURFACE W17H
APPROPRIATE COATING
NOTES:
1. MODERATE SPALL DEEPER THAN Tq" (7MM)
K17H SOME AGGREGATE LOSS, BUT NO
EXPOSED RE -BAR.
2. REMOVE ALL DAMAGED OR UNSOUND
CONCRETE.
3. THE EXPOSED SURFACES SHALL BE
ROUGHENED W17H 4" AMPLITUDE.
4. PRESSURE WASH AFTER EXCAVATION TO
REMOVE DUST, LAITANCE, AND OTHER
BOND INHIBI7NG MATERIALS, SSD
SUBSTRATE.
5. APPLY A 20 MIL COATING OF BONDING
AND ANTI -CORROSION AGENT ONTO THE
PREPARED SSD SURFACE TO INSURE
PROPER BOND OF THE REPAIR MATERIAL.
6. FILL EXCAVATION WITH APPROPRIATE
REPAIR MORTAR, CONSOLIDATE, FINISH
AND CURE.
Z APPLY PR07EC77VE WATERPROOF COATING
TO PREPARED SUBSTRATE.
8. PROVIDE THE ARCH17ECTURAL FINISH AS
REQUIRED BY OWNER.
THESE P_4P•113 AND ALL PROPOSED WORK
ARE SUBJECT TO ANY C01-1.9ECTIM-13
REQUIREDr SY FLD IINSPECTOR'STHAT
IMAY BE NECIESSAIRY IN
yEK TO
CO iPLY WITH ALL ARPL}CA"; E C0i;-ES.
EDGE AND SURFACE CONDITIONING
OF CONCRETE
L
3 u (O PY EDGE AND SURFACE CONDITIONING OF CONCRETE
�����s�" t� 1. THESE DETAILS ARE APPLICABLE TO HORIZONTAL,
VERTICAL, AND OVERHEAD LOCATIONS. THEY ARE ALSO
APPLICABLE TO REMOVAL BYHYDRO-DEMOLITION,
HYDROMILLING, AND ELECTRIC, PNEUMATIC OR
HYDRAULIC IMPACT BREAKERS.
BOUNDARY OF LOOSE AND RECOMMENDED
DELAMINATED CONCRETE LAYOUT
i d<
'a a
° <°
e.d e4.
VA
2. REMOVE DELAMINATED CONCRETE, UNDERCUT
N N
REINFORCING STEEL, REMOVE ADDITIONAL CONCRETE AS
o
REQUIRED TO PROVIDE MINIMUM REQUIRED THICKNESS
In LL 2
OF REPAIR MATERIAL.
N r c
3. CHIP OUT THE CONCRETE TO EXPOSE THE ENTIRE
m o a
CIRCUMFERENCE OF THE REBAR. REMOVAL SHALL
->
CONTINUE ALONG THE LENGTH OF THE REINFORCING
STEEL UNTIL AT LEAST 6" OF UNCORRODED STEEL
IS OBSERVED.
4. AT EDGE LOCATIONS, PROVIDE RIGHT ANGLE CUTS TO >uz
THE CONCRETE SURFACE WITH EITHER OF THE
FOLLOWING METHODS: (- S
4.1. SAWCUT 112 " (13 MM) OR LESS AS REQUIRED M W u
TO AVOID CUTTING REINFORCING STEEL. w
4.2. USE POWER EQUIPMENT SUCH AS $
HYDRODEMOLITION OR IMPACT BREAKERS. AVOID '=W� FEATHER EDGES.
4.3. REPAIR CONFIGURATIONS SHOULD BE KEPT AS
SIMPLE AS POSSIBLE, PREFERABLY WITH Z
SQUARED CORNERS. w O
or Q J
5. AFTER REMOVALS AND EDGE CONDITIONING ARE
COMPLETE, REMOVE BOND INHIBITING MATERIALS (DIRT, O � p
CONCRETE SLURRY, LOOSELY BONDED AGGREGATES) BY ui
v Lu
ABRASIVE BLASTING OR HIGH PRESSURE WATERBLASTING or
WITH OR WITHOUT ABRASIVE.
6. CHECK THE CONCRETE SURFACES AFTER CLEANING TO
INSURE THAT SURFACE IS FREE
FROM ADDITIONAL
_
LOOSE AGGREGATE, OR THAT ADDITIONAL DELAMINATIONS
U y
ARE NOT PRESENT.
=
a
7. IF HYDRODEMOLITION IS USED,
¢wt
m w z
CEMENT AND PAR77CULATE
i
>- 8
SLURRY MUST BE REMOVEDFROM PREPARED SURFACES
'
BEFORE SLURRY
01f� ��F�......�q
HARDENS.
,PQC)�: �ENSF
'Iolk
No. 61000
TRIF
- STATE OF
p
ET