HomeMy WebLinkAboutSTRUCTURAL CALCULATIONSTHOMAS Sign & Awning Company, Inc. 4590 118th Avenue North Clearwater. Florida 33762 Installation Location: Prime Vista & Floresta, Port St. Lucie, FL Description: 2 Ft Tall X 20Ft Long Gas Pump Canopy Spanner Panel Engineering Calculations Table of Contents Structural Calculations Client: WaWa #5220 Project Identity No.: 63870 Design No.: 55825 Structural Engineering Calculations Prepared by: John F. Dougherty, P.E. Florida P.E. No. 80640 Code: Florida Building Code, 5th Edition (2014) - Building 6UANNED BY St. Lucie Countv Pages 1-2 `DOUGH*///' O�, ��GENS�c•• R��// i No 80640 *; * ;i_ % It STATE OF i Oita P,•' THOMAS Sign & Awning Company, Inc. 4590 118th Avenue North Clearwater, Florida 33762 Florida Certificate of Authorization No. 31751 Installation Location: Prime Vista & Floresta, Port St. Lucie, FL Structural Calculations Client: WaWa Project No.:.64461 Design No.: 56990 Prepared by: John F. Dougherty Florida P.E. License No. 80640 Sign geometry: Sign Height, s 2 feet Sign Width, B 19.67 feet Sign Face Area, As 39.34 square feet Height from grade to top of sign, h 15 feet Say sign weighs 2 psf Then total weight = 78.68 Ibs Thickness of sign, t 0.25 feet Lateral wind area, Alat = t s = 0.5 square feet Florida Building Code 5th Edition (2014) Building (FBC 5th) Table 1604.5; Risk Category II Figure 1609A; Vult 160 mph Vasd = Vult (0.6)1/2 123.9 mph 1609.4.2; Surface Roughness B 1609.4.3; Exposure Category C grasslands and river flats nearby 1609.6.1 S. For ... solid free-standing... solid signs..., apply ASCE 7 provisions. ASCE 7-10 Chapter 29 Wind Loads on Other Structures Figure 29.4-1 Clearance ratio, s/h = 0.133 Aspect ratio, B/s = 9.84 Cf for Case A or B 1.85 Cfc1 for Case C, 0 to s 3.75 Cfc2 for Case C, s to 2s 2.45 Cfc3 for Case C, 2s to 3s 1.85 Cfc4 for Case C, 3s to 4s 0.95 Table 29.3-1 Kh = Kz 0.85 Table 26.6-1, Directionality Factor, Kd 0.85 for solid sign Section 26.8.2, Topographic factor, Kzt 1.00 Velocity pressure, qz = qh = 0.00256 Kz Kzt Kd Vasdz = 28.4 psf 1 of 2 2/10/17 Section 26.9 gust effect factor, G 0.85 Design wind pressure (Case A) = qz G Cf = 44.7 psf Eq. 29.4-1, F = qh G Cf As Case A and Case B, FIB = 1757 lb Case B, F applied 0.28 = 3.93 feet from center of sign Torsion = 6914 ft-lb Base moment, Mx,e = FAB(h-s/2) = 24,605 ft-lb Case C, F1= qh G Cfc1 s2 = 362 lb applied s/2 = Case C, F2 = qh G Cfc2 s2 = 237 lb applied 3s/2 = Case C, F3 = qh G Cfc3 s2 = 179 lb applied 5s/2 = Case C, F4 = qh G-Cfc4 s2 = 92 lb applied 7s/2 = Max pressure in Case C = 362 lb / sA2 = 91 psf Screw spacing, Ss = 1.3 ft .Shear in single screw, Vs = 90.6 psf x s/2 x Ss = 121 lb 1.00 feet from end of sign 3.00 feet from end of sign 5.00 feet from end of sign 7.00 feet from end of sign To be shown on construction documents: i ULTIMATE DESIGN WIND SPEED, Vult (3-SECOND GUST): 160 mph NOMINAL DESIGN WIND SPEED, Vasd: 123.9 mph RISK CATEGORY: II EXPOSURE CATEGORY: C DESIGN WIND PRESSURE: 44.7 psf { Refer to International Code Council (ICC) Evaluation Service Report ESR-2196 for Hilti, Inc. Self -Drilling and Self -Piercing Screws Table 4A Thickness of support frame (by others) is unknown, but assume 0.0625 inch Thickness of Spanner Panel 0.125 -inch For#8-18screws Fv/Q = 373 lb Stress ratio = Vs / (Fv/4) = 0.324 <= 1.00; OK 2 of 2 2/10/17