Loading...
HomeMy WebLinkAboutPLANS 1,10� CONTRACTOR: C&C CANVAS AND AWNING DESIGN CRITERIA APPLICABLE CODES, REGULATIONS, AND STANDARDS 1. THE STH EDITION (2014) FLORIDA BUILDING CODE, SPECIFICALLY CHAPTER 16 STRUCTURAL DESIGN, CHAPTER 20 ALUMINUM, AND CHAPTER 23 WOOD. 2. ASCE 7-10. WIND LOADS 1. BUILDING OCCUPANCY CATEGORY, PARAGRAPH 16D4.5 AND TABLE 1604.5: RISK CATEGORY II. 2. BASIC WIND SPEED, PER SECTION 3105.4.5.1. WIND DESIGN LOADS FOR FABRIC COVERED STRUCTURE WITH QUICK REMOVAL OR BREAKAWAY FABRIC. WIND SPEED: VULT=105 MPH, VASD = 82 MPH. 3. EXPOSURE CATEGORY, PARAGRAPH 1609.4.3: D 4. ROOF FABRIC SHALL BE REMOVED AT SUSTAINED WIND SPEEDS OF 75 MPH AND GREATER SCOPE OF WORK: 1. CANVAS AWNING WITH ALUMINUM FRAME. SPECIFICATIONS: THE FOLLOWING SPECIFICATIONS ARE APPLICABLE TO THIS PROJECT. 1. ALL WORK SHALL BE IN ACCORDANCE WITH THE 5TH EDITION (2014) FLORIDA BUILDING CODE, AND ANY OTHER APPLICABLE LOCAL CODES AND REGULATIONS. 2. AWNING AND / OR CANOPIES SHALL BE DESIGNED TO REQUIREMENTS OF CHAPTER 31, SPECIAL CONSTRUCTION, SECTION 3105.1, AWNINGS AND CANOPIES, OF THE FLORIDA BUILDING CODE, BUILDING, STH EDITION (2014). 3. ALL FABRIC SHALL COMPLY WITH THE FIRE PROPAGATION PERFORMANCE CRITERIA OF NFPA 701 OR HAVEA FLAME SPREAD INDEX NOT GREATER THAN 25 WHEN TESTED ACCORDING WITH ASTM E 84 OR UL723. 4.. FABRIC ATTACHMENT TO THE FRAME SHALL BE MADE IN A READILY REMOVABLE OR BREAK AWAY FASHION. S. AWNINGS AND CANOPIES SHALL BE DESIGNED SUCH THAT THEIR FABRIC COVERINGS SHALL BE READILY REMOVABLE DURING PERIODS OF HIGH WIND VELOCITY. A LEGIBLE AND READILY VISIBLE DECAL SHALL BE INSTALLED ON THE AWNING OR CANOPY INSTRUCTING THE OWNER OR TENANT TO REMOVE THE FABRIC COVERING FILM SUCH PERIODS AS ARE DESIGNATED BY THE U.S. WEATHER AS BEING A HURRICANE WARNING OR ALERT. (SUSTAINED WIND SPEEDS OF 75MPH AND GREATER). 6. ALL FRAME MEMBERS SHALL BE CONNECTED WITH 1/4" FILLET WELD AROUND ALL INTERSECTING EDGES. ALL WELDS SHALL USE GAS METAL ARC WELDING PROCESS THAT CONFORM TO THE AMERICAN WELDING SOCIETY'S STRUCTURAL WELDING CODE -ALUMINUM (131.2). WELD WIRE SHALL BEALLOY 4043, 5198, OR 5356. 7. MECHANICAL FASTENERS ARE REQUIRED TO BE CORROSION RESISTANT, MINIMUMS ARE GRADE 2 OR BETTER ZINC PLATED TO ASJM B633. OR COATED STAINLESS STEEL SERIES "300" OR UNCOATED STAINLESS STEEL SERIES "400". S. ALL FRAME MATERIAL SHALL BE 1" 6053-T52 SCHEDULE 40 ALUMINUM PIPE UNLESS OTHERWISE NOTED. 9. WHERE CONCRETE SPECIFICATIONS ARE REQUIRED, WHETHER IN THE SCREEN ENCLOSURE SCOPE OR NOT, BY ONE OR MORE REGULATORY AGENCY, THE FOLLOWING SPECIFICATIONS ARE APPLICABLE: A CONCRETE SHALL CONFORM TO ASTM C94 FOR THE FOLLOWING COMPONENTS: 1. PORTLANDE CEMENT TYPE 1, -ASTM C 150 11. AGGREGATES - LARGE AGGREGATE 3/4" MAX - ASTM C 33 III. AIR ENTRAINING +/_1%-ASTM C260 IV. WATER REDUCING AGENT- ASTM C 494 V. CLEAN POTABLE WATER M. OTHER ADMIx URES NOT PERMITTED B. METALACCESSORIES SHALL CONFORM TO: I. REINFORCING BARS-ASTM A615, GRADE 60 II. WELDED WIRE FABRIC - ASTM A185 C. CONCRETE SLUMP AT DISCHARGE CHUTE NOT LESS THAN 3" OR MORE THAN 5". WATER "F ADDED AFTER BATCHING IS NOT PERMITTED. D. PREPARE AND PLACE CONCRETE PER AMERICAN CONCRETE INSTITUTE MANUAL OF STANDARD PRACTICE, PART 1, 2, AND 3INCLUDING HOT WEATHER RECOMMENDATIONS. E MOIST CURE OR POLYETHYLENECE CURING PERMITTED. F. PRIOR TO PLACING CONCRETE, TREAT THE ENTIRE SUBSURFACE ARE FOR TERMITE IN COMPLIANCE WITH THE FBC. G. CONCRETE SHALL BE PLACED OVER A POLYETHYLENE VAPOR BARRIER. H. ALL ALUMIMUM COMPONENTS EMBEDDED WITHIN CONCRETE SHALL BE COATED WITH A BITUMINOUS PAINT OR EPDXY. 10. ALL FLASHING AND WEATHER PROOFING SHALL BE PROVIDED BY THE CONTRACTOR Y'^v, 01401A 01. Frame Attachment detail Existing CBS Wall 3 1/4" x 1/4" Tapcons set Pipe and into Concrete structure on 40" centers or less 40" or less I-10' O]rIPSS 1 r--I THESE PLANS AkD ALL PROPOSED WOW ARE SOJECT TO ANY COPIRECTIONS REOUIRED BY PIELD INSP.EC'PDRS THAT MAY BE NECn8Ai1Y M OMM To COMPLY WITtI ALL APPLICABLE COflES, ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIA :D BY DATE MUST BE KEPT OWJOB OR NO INSPECTION WILL BE MADE ;C7 �W i i ' <ing - Clear Silicon SCANNEL, BY St. Lucie Count, RECEIVE® NOV 2 2 2016 PERMITTING St. Lucie County, FL PR( ►lien 0 z SHi. 1 0 LU -i CYD I"- C.i CD J r m 000 m J 85 M o ZZp o w -J O 0) Ln U w LLL. z LL M w Q d Q 2 d Q U O LL 0 N U 00 a W of F- XQLLLL Ld Q�U DO = J Ujco J r F- �oEL