HomeMy WebLinkAboutWELDER QUALIFICATION TEST RECORDP�lAlUlT Z.f Welder Qualification Test Record
WQTR No. YC-0GSMAW Welder Name YOEL CABRERA
WPS No. B2.1-001-90 Revision SO Date 3r
Variables Record Actual Values Used In Qualification
Process (Table 4.10, Item (2)) SMAW
,
Transfer Mode (GMAW): Short-Cir. ❑ Globular ❑
Spray ❑
Type Manuai ® Machine ❑ Semi -Auto ❑
Auto ❑
Number of Electrodes Single 21Multiple ❑
Current/Polarity AC ❑ DCEP ® DCEN ❑
Pulsed ❑
Position (Table 4.10, Item (5)) 3G
Weld Progression: (rable 4.10, Item (7)) Up ®
Down ❑
Backing [Table 4.10, Item (8)) Use Backing
Consumable Insert (GTAW) Use Insert ❑
MateriaUSpec. A36 to A36
Thickness (Plate): Groove in ). .375
Filet ( ) WA
Thickness (Pipettube): Groove ( ) WA
Fillet ( ) WA
Diameter(Pipe): Groove ( ) WA
Filet ( )N/A
YC-3GSMAW
Welder Id �CY•3G/n1SppppM��/�AW
015 LnJ NNED
Qualification Range St. Lucie,
SMAW Countv'
Short -Circuiting ❑ Globular ❑ Spray ❑
Manual ® Machine ❑ Semi -Auto ❑ Auto ❑
Single ® Multiple ❑
AC ❑ DCEP ® DCEN ❑ Pulsed ❑
Flat, Vertical, Horizontal
Up ® Down ❑
With Backing 0 Without Backing ❑
With Insert ❑ Without Insert ❑
GROUPI
.750 in
.126 - UNLIMITED in -
.125 - .760 in
.125 - UNLIMITED in
?R - UNLIMITED in
ANY - UNLIMITED in
Notes NONE NONE
Filer Metal (Table 10, Item (3))
Spec. A5,1/AS.5 EXXIS,EXXI6,EXX18,EXXi6-X,EXXIS X E)0C18-X
Class. 7018 EXXI5,EXX16,EXX18,EXXIS-X,EXX75•X,EXX18-X
F-No. F-4 F1 t0 F4
Gas/Fux Type (Table 4.10, Item (4)) WA
Other WA
VISUAL INSPECTION (4.8.1) Acceptable Yes
GUIDED BEND TEST RESULTS (4.30.5)
Type Result Type Result
FACE PASS
ROOT PASS
Fillet Test Results (4.30.2.3 and 4.30.4.1)
Appearance WA Fillet Size WA Marxoetch WA
Fracture Test Root. Penetration WA Description
Inspected By ALBERT HERMIDA SCW112010018 No. CY3GSMAW OrganizationCONTINENTAL WELDING INSPE0/7/2015
RADIOGRAPHIC TEST RESULTS (4.30.3.1)
Film Identification No. Result Remark
N/A Interpreted By WA
Alberto H rmida Organization CWI
' ® SCWI 1 10018 Test No. CY3GSMAW
QC7 EXP. 111/2018 Date 3/7/2015
We, the undersigned, certify that the statements in this record are correct and that the test welds were prepared, welded, and
tested in accordance with the requirements of section 4 of ANSUAWS D1.1, (10 ) Structural Welding Code -Steel.
Manufacturer CONTINENTAL WELDING INSPECTION Authorized By ALBERT HERyMI-DA SC M20100018 Date 3/7/2015
'erAWSDI.1
AUG 3 0 29V
PERMITTING
St. Lucie County, FL
521 NW Ent ".j'/ir&fk Me)POrt St. Lercle, Florida 34986
Phone: (772) 924-3575 Fax: (772) 924.3580
BY \' STRUCTURAL STEEL
St. Lucie COUntV _ _• „ INSPECTION REPORT
L�P
GFA PROJECT# PURSUIT BOATS MILL SHOP AND yTF N DATE Friday, May 19, 2017
PROJECT WARRANTY BUILDING
3901 ST. LUCIE BOULEVARD S I M I T w I TH F S
LOCATION FORT PIERCE, FLORIDA DAY 19TH
PERMIT NO. N/A
BRIGHT SUN CLEAR OVERCAST RAIN
OWNER PURSUIT BOATS WEATHER X
RICHARD K DAVIS BELOW 60 60-7e 75-90 AeoVE 90
CONTRACTOR CONSTRUCTION CORP. TEMPERATURE X
LOW MODERATE HIGH Report No
ARCHITECT N/A WIND X
LOW MODERATE HIGH
ENGINEER N/A HUMIDITY X
MEMBERS/AREA INSPECTED: -®Re-inspection -
ALL BOLTED CONNECTIONS.
THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED SCANNED
CONTRACT DOCUMENTS AND ACCEPTED PRACTICES. BY
COMPLIES St. Lucie Countv
YES NO N/A
X 1 MILL CERTIFICATION AND TEST REPORTS
X 2 DISTORTION, EXCESSIVE RUST, BURNED HOLES Ems
FILt
X 3 CAMBER
X 4 SIZE, THICKNESS, WEIGHT
X 5 SPLICES
X 6 BOLTS IN ALL BOLT HOLES
X 7 ANCHOR BOLT SIZE, LENGTH, PLUMBNESS, EMBEDMENT, THREAD PROJECTION
X 8 HIGH TENSILE BOLT -SIZE, LENGTH, TYPE, WASHERS, NUTS
X 9 BOLT TORQUEING
X 10 COLUMN ALIGNMENT, BASE PLATE SIZE AND FIT
X 11 GROUTING OF BASE PLATES
X 12 BAR -JOIST SIZE, SPACING, BEARING, CONDITION
X 13 BAR -JOIST BRIDGING AND BRACING
X 14 CORRUGATED ROOF DECK GAUGE, CONDITION, SIDE AND END LAPS
X 15 HEADED STUDS PLACEMENT AND WELDING
DISPOSITION OF INSPECTION:
F—TiSection / Area Approved =Work In Progress =Re -Inspection Required
COMMENTS / ACTION REQUIRED: DUE TO MISPLACED ANCHOR BOLTS, COLUMN BASE PLATES WERE CUT
TO FIT ANCHOR BOLT PATTER. ENGINEERS LETTER WILL BE REQUIRED, %111tit t tatrr
Inspection Performe(oy: TE I SOE, BJV 4��8
Inspection Certifies By, 612017
ONALD WytMOLER, P.Er
Registered Professional ND: P.E. 60675
9 ' STATE OF : 41i
Certified Special InspectorNM N/A: .(t,
form revised 11I21/06 FBPE Certificate Ifdj : R I �• e♦
a.0.
Environmental • Geolechnical • Construction Materials Testing • Special & Threshold Inspections • Plan Review & f ftll' ygplt%'
Florida's Leading Engineering Source
521 NW
AUG 0 4. 20V
St.
GFA PROJECT#
17-0156.01
Pursuit Boats
PROJECT
Mill Shop and Warranty Building
LOCATION
3901 St. Lucie Boulevard
PERMIT NO.
N/A
OWNER
Pursuit Boats
CONTRACTOR
Richard Davis
ARCHITECT N/A
ENGINEER N/A
Phone: 72 924.3575 Fax: 72 924-3580
I WELDING
INSPECTION REPORT
DATE Monday, June 26, 2017
WEATHER
TEMPERATURE
WIND
HUMIDITY
S M T W TH F S I
DAY 26th
BRIGHT SUN
CLEAR
OVERCAST
RAIN
X
BELOW 60
60-75
75-90
ABOVE90
X
LOW
MODERATE
HIGH
Report No
X
LOW
MODERATE
HIGH
X
TYPE OF INSPECTION: vlsuAL ULTRASONIC= =Re -Inspection
DYE PENETRATION RADIOGRAPHIC
MAGNETIC PARTICLEx
MEMBERSIAREA INSPECTED: Base plates if four columns required new holes to be burned out to fit anchor
bolts. Unused holes were plug welded. These columns were in frames line two. _
THE FOLLOWING HAVE BEEN INSPECTED FOR COMPLIANCE WITH THE APPROVED
CONTRACT DOCUMENTS AND ACCEPTED PRACTICES.
COMPLIES
YES NO N/A
X 1 VERIFICATION OF WELDERS CERTIFICATIONS
X 2 WELD SIZE, LENGTH, SPACING, TYPE, SHAPE, LOCATION
X 3 BASE METAL
X 4 WELDING RODS AND WIRE
X 5 WELDS CLEAN AND FREE OF SLAG
X 6 POROSITY
X 7 WARPAGE AND DISTORTION
X 8 NON-METALLIC INCLUSIONS
X 9 IMPERFECT FUSION
X 10 UNDERCUTTING P IS
X 11 CRACKING
X 12 SURFACE HOLES FILE C01
X 13 DEFECTIVE WELDS MARKED
DISPOSITION OF INSPECTION:
AAIAA III/f/f
Section / Area Approved Work In Progress t }3r,-,I l�pKO*ired
COMMENTS/ACTION REQUIRED: Work wad.pl~Lfprmedas,requifg9 if�yapr�okyiE'rgs�C
form revised 11/21/06
st ;
Inspection Performed:.
r
Inspection Cerfa
Registered Professio",
Certified Special Inspector
FBPE Certificate No:
Envim..W. GmWl nl.l. Construction Materiels Tesgng.Spedal&Thmandd Insped.ns. Plan Review& Code Compliance
Florida's Leading Engineering Source
www.I.,ogiacan