Loading...
HomeMy WebLinkAboutNOAMIAMI•DADE DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION n SCANNEL/ �l I BY St. Lucie Count MIAMI-DADr COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (796) 31525-99 NOTICE OF ACCEPTANCE (NOA) RECEIVE[) www.miamidade.gov/economy Johns Manville Corporation 71717th Street NOV 2 9 2016 Denver, CO 80202 PERMITTING SCOPE: St. Lucie County, FL This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Johns Manville Modified Bitumen Roofing Systems over Cementitious Wood Fiber Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically. terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature: If any portion of the NOA is displayed, then it shall be done in its entirety. ' INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official.' This-NOA renews and revises NOA No. 13-0529.17 and consists of pages I through 18. The submitted documentation was reviewed by Jorge L. Acebo. NOA No.: 16-0413.26 MIAMMADE COUNTY Expiration Date: 07/19/21 Approval Date: 07/14/16 FILE Page 1 of 18 ROOFING SYSTEM APPROVAL Category: Roofing Sub -Category: Modified Bitumen Materials: SBS Deck Tvpe: Cementitious Wood Fiber Maximum Design Pressure: -105 psf. TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Dimensions Specification Product Description DynaBase 39-3/8" x 49'2" ASTM D6163 A glass reinforced SBS modified bitumen DynaBase HW 39-3/8" x 49'2" DynaBase PR 39-3/8" x 49'2" DynaBase XT 39-3/8" x 49'-2" DynaClad 39-3/8" x 33'10" DynaFast 180 HW 39-3/8" x 49'2" DynaFast 180 S 39-3/8" x 49'2" DynaFast 250 HW 39-3/8" x 32' 10" DynaGlas 39-3/8" x 32'40" DynaGlas 30 FR 39-3/8" x 32'-10" DynaGlas FR 39-3/8" x 32'-10" DynaGlas FR CR 39-3/8" x 32'-10"; DynaGlas FR CR 39-3/8" x 32' 10" G DynaGlas-FR XT 39-3/8" x 32'-10" MIAMMADE COUNTY base sheet. ASTM D6163 A glass reinforced SBS modified bitumen base sheet for heat welded applications. ASTM D6164 A polyester reinforced SBS modified bitumen base sheet. ASTM 136163 A glass reinforced SBS modified bitumen base or inner ply sheet. ASTM D6298 A glass reinforced base sheet SBS modified_ bitumen membrane surfaced with foil. ASTM D6164 A polyester reinforced SBS modified bitumen base or inner ply sheet for use in heat weld applications. ASTM D6164 A polyester reinforced SBS modified bitumen base or inner ply sheet. ASTM D6164 A polyester reinforced SBS modified bitumen base or inner ply sheet for.use in heat weld applications. ASTM 136163 A glass reinforced SBS modified bitumen membrane surfaced with granules. ASTM D6163 A fire resistant, glass reinforced SBS modified bitumen membrane surfaced with granules. ASTM D6163 A fire resistant, glass reinforced SBS modified bitumen membrane surfaced with granules. ASTM D6163 A fire resistant, glass reinforced SBS modified bitumen membrane surfaced with granules and a reflective white coating for use in heat weld,applications. ASTM D 6163 A fire resistant, glass reinforced SBS modified bitumen membrane surfaced with granules and cool roof coating. ASTM D6163 A fire resistant, -glass reinforced SBS modified bitumen membrane surfaced with granules. . NOA No.: 16-0413.20 Expiration Dater 07/19/21 Approval Date: 07/14/16 Page 1 of 18 APPROVED ASSEMBLIES Membrane Type: SBS Deck Type 5I: Cementitious Wood Fiber, Insulated Deck Description: Cementitious Wood Fiber System Type A(1): All layers of insulation adhered. Roof membranes subsequently fully adhered. All General and System Limitations apply. Base Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 ENRGY 3, ENRGY 3 25 PSI, ValuTherm, ValuTherm 25 PSI, R-Panel, R-Panel 25 PSI, ENRGY 3 AGF, ENRGY 3 AGF 25 PSI, ValuTherm AGF, ValuTherm AGF 25 PSI, ENRGY 3 CGF, E*25 R1; ValuTherm CGF, ValuTherm CGF 25 PSI, ENRGY 3 FR, ENRGY 3 FR I Minimum 1.5" thick N/A N/A op Insulation Layer Insulation Fasteners Fastener (Table 3) Density/ft2 o- 't Boaid Minimum'/:" thick N/A N/A No e: ayers of insulation shall be adhered with JM Roofing System Urethane Adhesive applied in %" ribbons spaced 12" o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Composite insulation boards used as a top layer shall be installed with the polyisocyanurate face down. Base Sheet: One ply of DynaBase, DynaBase PR, DynaBase XT, DynaMax S, DynaLastic 180 S, DynaFast 180 S, DynaPly Tl, or DynaLastic 250 S adhered to the substrate with JM MBR Cold Application Adhesive fully adhered at an application rate of 1.5 — 2.0 gal/sq. Ply Sheet: (Optional) One or more plies of DynaBase, DynaBase PR, DynaBase XT, . DynaMax S, DynaLastic 180 S, DynaFast 180 S, DynaPly Tl or DynaLastic 250 S fully adhered to the base sheet with MBR Cold Application Adhesive applied at an application rate of 1.5 — 2.0 gal/sq., Or, ne or more lie ynaBas DynaBase PR, DynaBase XT, DynaMax S, DynaLastic 180 S, Dyn ast 180 S, DynaPly T I or DynaLastic 250 S fully , /J adhered to the base sheet with approved mopping asphalt at an application rate of (�/(v 20-401bs./sq. Or. One or more plies of DynaBase HW, DynaWeld 180 S, DynaWeld Base, DynaFast 180 HW, DynaWeld 250 S or DynaFast 250 HW heat welded. NOA No.: 16-041120 Mwra•onne Courrry Expiration Date: 07/19/21 Approval Date: 07/14/16 Page 10 of 18 Membrane: One or more plies of DynaGlas 30 FR, DynaGlas, DynaGlas F , DynaGlas FR CR, DynaGlas FR CR G, DynaLastic 180, DynaLastic 0 FR, DynaLastic 180 FR i CR, DynaLastic 180 FR CR G, DynaGlas FR XT, DynaKap FR T1, DynaKap FR Tl CR G, DynaLastic 250 FR, DynaLastic 250 FR CR, DynaLastic 250 FR CR G, DynaMax FR, DynaMax FR CR, or DynaMax FR Plus fully adhered to the base sheet with MBR Cold Application Adhesive or fully adhered at an application rate of 1.5 — 2.0 gal/sq. Or, One or more plies of DynaGlas 30 FR, DynaGlas, DynaGlas FR, DynaGlas FR CR, DynaGlas FR CR G, DynaLastic 180, DynaLastic 180 FR, DynaLastic 180 FR CR, DynaLastic 180 FR CR G, DynaGlas FR XT, DynaKap FR Tl, DynaKap FR TI CR G, DynaLastic 250 FR, DynaLastic 250 FR CR, DynaLastic 250 FR CR G, DynaMax FR, DynaMax FR CR or DynaMax FR Plus fully adhered to the base sheet with approved mopping asphalt at an application rate of 2040 lbs./sq. Or, One or more plies of DynaWeld Cap FR, DynaWeld Cap FR CR, DynaWeld Cap FR CR G, DynaWeld Cap 180 FR CR, DynaWeld Cap 180 FR DynaWeld Cap FR XT, DynaWeld Cap 250, DynaWeld Cap 250 FR, DynaWeld Cap 250 FR CR, DynaWeld Cap 250 FR CR G, DynaKap FR Tl HW CR G, DynaMax FR HW, or DynaMax FR HW CR heat welded. Maximum Design Pressure: -105 psf. (See General Limitation 49) MIAMI-DADE COUNIY NOA No.: 16-0413.10 Expiration Date: 07/19t2i Approval Date: 07/14/16 Page 11 of 18 GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbsJsq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F) value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 Ibf. Insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter-nailers, metal profile, and/or flashing termination designs. shall conform to Roofing Application Standard RAS I I I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis; nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA No.:16-0413.20 Expiration Date: 07/19/21 Approval Date: 07/14/16 Page 18 of 18