Loading...
HomeMy WebLinkAboutPLANSBUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS d CLADDING (&S.F,) FOR ASCE 7 10 PEAK ROOF HEIGHT LEW THAN OR EQUAL TO 60 FEET ar BASIC WIND SPEED = 170 mph RISK CATEGORY R BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT To ANY CORRECTIONS REQUIRED BY FIELD INSPCCTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALLAPPLICABLE CODES. PEAK ROOF L•` LESS THAN 7'-9" L- GREATER OR EQUAL THAN 7'-9" AND L£55 THAN 12'-3" L GREATER OR EQUAL THAN 12'-3" HEIGHT POSITIVE NEGATIVE PoS/TNE NEGATIVE POSITIVE NEGATIVE (h) ULTIMATE A.S.D. ULTIMATE A.S.D. ULTIMATE I ASD. ULTIMATE ASD. UL77M4TE AS.D. ULTIMATE A.S.D. 0' - 15' 76.4 45.8 102.4 61.4 73.0 43.8 95.5 57.3 68.5 47.1 86.4 51.8 > 75'-20' 80.4 48.2 107.6 64.6 76.8 46.1 100.4 60.2 72.0 43.2 90.8 54.5 > 20'-25' 83.6 50.2 111.9 671 79.8 47.9 104.4 62.6 74.8 44.9 94.4 56.6 > 25'-30' 86.2 51.7 115.5 69.3 82.4 49.4 107.7 64.6 77.3 46.4 974 58.4 D'- 90.7 54. 121.4 72.8 86.6 62.0 7133 68.0 81.2 48.7 102.4 61.4 > 40'-50' 94.3 6.6 126.2 75.7 90.0 54.0 1177 70.6 84.4 50.6 106.5 63.9 > 50'-60' 973 58.4 1 130.3 1 78.2 92.9 55.7 121.5 72.9 872 52.3 109.9 65.9 J�ByVtL Cnnnhl * INDICATED DESIGN WIND PRESSURES CORRESPOND TO THE MAXIMUM END ZONE AND INTERIOR ZONE CONDITIONS AND FOR ALL ROOF SLOPES. Aeat L = STORM PANEL LENGTH, ACCORDION SHUTTER BLADE LENGTH OR BANANA SHUTTER HEIGHT. *** PRODUCTS WHICH BEAR A MDIMI-DADE COUNTY OR A STATE OF FLORIDA APPROVAL BUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADDING (P S F) FOR AkE 7 10 PEAK ROOF HEIGHT GMTFR IMAM 60 FEET* BASIC WIND SPEED = 170 mph RISK CATEGORY ll BUILDINGS RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE) CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD RECEIVED MAR 0 2 2018 ST. Lucie county, Permitting - UQ /(. ST LUCIE COUNTY BUILDING DIVISION REVIEWED FOR C iIANCE REVIEWED BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE 111%.3 IL PEAK ROOF L•• LESS THAN 12-3" L" GREATER OR EQUAL THAN 12'-3' HEIGHT POSITIVE NEGATIVE POSRNE NEGATIVE (h) ULTIMATE A.S.D. UL71MATE A.S.D. ULTIMATE A.SD. ULTIMATE A.S.D. > 60' - 70' 91.5 54.9 167.7 100.6 84.3 50.6 148.4 89.0 > 70' - 80' 93.6 56.2 171.6 103.0 86.2 51.7 751.9 91.1 > 80' - 90' 95.5 574 175.2 105. 1 88.0 52.8 155.0 93.0 > 90' - 100' 973 58.4 178.4 107.4 89.7 53.8 1579 94.7 > 100' - 120' 100.5 60.3 184.2 110.5 92.5 55.5 1630 97.8 > 120' - 140' 103.2 61.9 189.2 7 13.5 95.1 57. i 1674 100.4 > 140' - 160' 105.E 63.4 193.6 116.2 973 58.4 171.3 102.8 > 160' - 180' 1078 64.7 1976 118.6 99.3 59.6 174.9 104.9 > 180' - 200' 109.8 65.9 201.3 120.8 101.1 60.7 178.1 1 106.9 > 200' - 250' 114.1 68.5 209.2 1 125.5 105.2 63.1 185.1 111.1 > 250' - 300' 1178 70.1 216.0 129.6 108.5 65.1 191.1 114.7 > 300' - 350' 121.0 72.6 9 133.1 111.5 66.9 196.3 117.8 > 350' - 40o' 123.9 74.3 1 136.3 114. 1 68.5 200.9 120.5 > 400' - 450' 126.4 75.8 8 L23 139.1 116.5 69.9 205.1 123.1 > 450' - 500' 128.8 77.3 1 141.7 118.6 71.2 208.9 125.3 1.) THIS CERTIFIED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-10, FOR A BASIC WIND SPEED OF 170 MPH, AND APPLICABLE RISK CATEGORY BUILDING & EXPOSURES IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT. 2.) THIS WMD LOAD CHART MUST BE SIGNED, SEALED AND GATED BY THIS ENGINEER 1F USED TO OBTAIN A ONE TIME BUILDING PERMIT. 3) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELECTION OF DESIGN WWD PRESSURE BASED ON THIS GENERIC WIND LOAD CHART. WIND PRESSURES ARE ULTIMATE AND ASD. PRESSURES. 4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID IF ALTERED BY ANY MEANS 5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS WIND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUMENT PREPARED BY THE CONTRACTOR OR PERMIT HOLDER (e.9., SPREADSHEET, OPENING SCHEDULE/TAKE OFF SHEET, ERG). A $jEQF L, No. 44167 •o t STALE VILL 8110) PE pF �� 1 �E`G\Al 2017 (6th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDUW RIMER ASC£ 7-10 / WIND PRESSURE CHART L.C. STORM PANELS, ACCORDION & 84H" SHUTTERS 'R•• DRAWN BY RISK CAT. If BLDGS 08109117 L E C O INC. WIND PRESSURE CHART DATE T TESANG & ENGINEERING QOMPANY BASIC WIND SPEED = 170 mph % 7- 194 'w .urA. s5G., Sre. ,mS VM" G+RDD'b: TL micG IXPoSURE D. Kd = 0.85 (J05197r-rxTo . F= : (ms)e7r-rsTr DRAWING No ES-0006719 m. ne 1ormvM.w an Arr. ". aamvmx ua WALTER A RLUT Jr. P.E. ' am ro-rrM 7r • SHEET i Of 1 _ _ FLORIDA Uc. # 44167 2