Loading...
HomeMy WebLinkAboutPRODUCT APPROVALBcls Nome Lag In I User"U'atba Hot Tap. Submit Surcharge Stats & Facts lvblicaWns rae Statf 1, acts site Map � Links Saa,d, � ra p�. o Product Approval r USER: Ppp iter J1 ROCu[L ApaGral NMJ> Pmautt at llodknMen iea2a> Appik. l4nLn\> /WPllydtlan Detail yrylll'\,f� r 1 FL# RECEIVED L389-R9 It `(l APDlication Ty0 evasion (,'/(� Count, Code Version 017 Application Sta 5 JUL 0 2 2018 PProved Comments ST. Lucie County, Permitting Archlved ❑ Product Manufacturer American Shutter Systems Association, Inc. Address/Phone/Emall 4268Westroads Drive West Palm Beach, FL 33407 (561) 200-6263 bfeeiey@eastemmetal.cam Authorized Signature Bill Feeley Irodriguez@easternmetal.com Technical Representative Address/Phone/Email Quality Assurance Representative THESE PLANS AND ALL PROPOSED WORK Address/Phone/Email ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT Category shutters MAY BE NECESSARY IN ORDER TO Subcategory Accordion COMPLY WITH ALL APPLICABLE CODES. Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed. Florida Professional Engineer ❑ Evaluation Report - HaMcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract ExpirationDate Validated By Certificate of Independence ggN9 ALED FASTENERS OR 4TTACHMFNTS ARE.THEAESPONSI II ; T.:' F THE GONTPXCTOR r , ,I.: Walter A.. Tillit, Jr. P.E. PE-44167 National Accreditation and Management Institute 12/31/2018 John Henry Kampmann Jr. 0 Validation Checklist- Hardcopy-Received Referenced Standard and Year (of Standard) Standard Equivalence of Product Standards Certified By LL ASTM E-1886 ASTM E-1996 ASTM E-330 TAS 201, 202, 203 QEn>µ t Igo-T ST. LUCIE COUNTY BUILDING D1 N REVIEWED FOR C0MPL1ANrF %1k year 2005 2005 2002 1994 SITE OR NO iNSREGTION(S) wILLrBE MADE Sections from the Code Product Approval Method Method I Option D Date Submitted 09/18/2017 Date Validated 10/18/2017 Date Pending FBC Approval 10119/2017 Date Approved 12/12/2017 Summary. of Products FL S Modely Number or Name Description 389.1 Bertha HV Accordion Shutter -. Blade - (Non-HVHZ)- Drwg 17- Extruded aluminum Interlocking blades retained by tracks (top and bottom) for storm protection 108 Limits of Use Installation Instructions Approved for use in HVHZ: No n 189 R9 11 AMERICAN SHl M:ER SYSTEMS DRAWING 17-IOB. BERTHA HV ACCORDION SHU R s3'STFM.PDF Approved: foruse outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile Level "D".Max span Is 12'-3" for 40 psf Verified By: American Test Lab of South Florida Inc. Created by Independent Third Party: Yes Evaluation Reports positive ASO load and 13'-0' for 35 psf negative ASD load the HV3 blade w/o window blade,5'-2" for 110 psf ASD load for HV3 blade w/o window. blade and 8'-11" for 62 psf, W-111 F19R9 R9 AE- AMERICAN SHInTFR-SYSTEMS ORAWING 0.108 PRODUCT EVALUATION REPORT.PDF Created by independent Third Parry: Yes for 55 psf HV3 blade w/window blade working in unison.Max.spanfor HV3 blade w/o window blade for installations Into Metal Stud walls is 79' for max. ASD pressure rating. of +72,-72:and 841 for +64,-64.psf. See sheet 5for other spans and ASD pressures. 389.2 Bertha HV Accordion Shutter -Blade Y Only-(Nan-HVHZ)- Drwg 17-107 Extruded aluminum interlocking blades retained by tracks (top and bottom) for storm protection Limits of use Installation Instructions FS 169 R9 It AMERICAN SHUTTER SYSTEM ASSOC,- Approved for use in HVHZ: No INC, DRAWING 17-107 BERTHA HV ACCORDION. SHUTTER Approved for use Outside HVHZ: Yes SYSTEM.PDF Verified By: American Test Lab of South Florida Inc Created by Independent Third Party: Yes Evaluation Reports FI389 R9 AE AMERICAN SHLrTTFR SYSTEM ASSOC., Impact. Resistant: Yes Design. Pressure: N/A Other: Large missile level'D". Max. Span is 16'-0" for 30 p.s.f negative loaddepending on centermates and locking rod configuration for the HVl blade, 8'-0" for +64, - 72. p.s.f. A.S.D. load for HV blade for Keystone mountings T-0" p.s.f. for metals stud mountings and 8'-0' for 110 p.s.f. for HV1A working in unison. See sheets: 7, 11 and.20 INC, DRAWING 17-107 PRODUCT OF EVALUATION BLEUBTADF Created by Independent Third Party Yes respectively of installation drawings for other spans and pressures. 389.3 Bertha`.HV Accordion Shutter- COMBO- (Non-HVHZ)- Drwg 17-106. Extruded aluminum interlocking blades retained by tracks (top. and bottom). for storm protection Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Installation Instructions FI iog R9 if AMERICAN SHI UM SYSTEMS A550_C., INC, .DRAWING 17-106 BERTHA HV ACCORDION SHLTTrER SYST.POF Verified By: American Test Lab of. South Florida Inc. -' Created by Independent Third Party: Yes Evaluation Reports Pn 389 R9 AE AMERICAN SHUTTER SYSTEMS A550C Impact Resistant: Yes Design Pressure: N/A other. Large missile. Max. 16'-0" span at 30 p.s.f ASD load. for Blade 1 and 18'.0" for Blade 2. Seeschedules on sheet 12. 25 and 28 respectively INC,. DRAMIING 17-196 PRODUCTEVALUATION REPORT.PDF Created by Independent Third Party: Yes , balad US n 2NI B,j,S 2399 Paare- 850-487,1824 The State Or Hoods is an AAyEEO employer. rOuvdnht 2007-2013 Stam a Fbnde.:: w m, Statement 1: AcceSmbllev statement :: Rehma Statement Under Flemn, Ind, emit add.. am pYNe Menlo. If YOU d0 hat net year e-mail Hd ., mimed In w,mm! 10 a W OEP'RtOrd9 rMYelt, a0 nOt6Md ltedMic melt to thin entay. IwtW, contaR the effee by phone or by traddbnai mall. If you hove any Ouenmen, please caned 850.4aL1395. •Pursuant to seetmn 455,275 (1), Fends Smmms, effMlme Cem e,1, 2012, btenseen IhObamd under chapter 455, F.S. main proviee the cat wa ent WIN an ¢mall aMme, If they have One. The ¢malls pmma veed y....be use fordf dai mmmunlmrlon with Me licensee. HOwever.em it sentry ec are Wblic record. Ir raw do not-"ah m supdy a personal addmsa. .. .. . .. . -- -_-�. -..�. _a...-.. r......a. "...rr.u" m rndb�uuc. Te d¢termin! If v9u am admnsee under ChdPmr CSS; F.S., Plees4 Product Approval Accapv: