HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
J(;HIVIVtU
Certification for Design Load Compliance BY
Project Name: Pepj2er Park Boardwalks St. Lucie County
Project Address: SRA-1-A St Lucie County North Beach Pepper Park
Permit#: Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
o This certification must be completed, signed, and sealed by the design professional of record.
o Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family) I
o Residential Addition
Any accessory structure requiring a building permit
Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida +odes Zip ition with 20Supplements using ASCE 7-10 SeeNote 1 below
13 Structure Designed as (check one): _Enclosed _Partially Enclosed _Open Not Applicable
Risk Category: _I _II _III _IV ExoosuYe Category: B _C _D Not Applicable
4. Design Wind Velocity 170 mph _ASD X LRFD End Zone Width: N/A it
N/A R Roof Pitch: N/A :12 Parapet: N A
�5. Mean Roof Height ft Not Applicable—
�by Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Not Applicable
® Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage:
7. Design Loads: Floor: PSF Roof/Dead: PSF Roof/Uve: Balcony: PSFNot Applicable
Dock: PSF Deck: PSF Stairs: PSF Fence: PSF Railings• PSF
8. Were Shear Walls Considered For Structure? Yes _Not Applicable Explain Why Not: Not Applicable
This is for a pedestrian bridge and not a building
9. Is A Continuous Load Path Provided? R Yes _Not Applicable Explain Why Not:
.tip. -Design Soil Bearing Pressure: PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
1 certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
J�,WDate,
��CEl11S''�gTj�sie
iS
'0. .' W
9SiL�YF�nmt(?2p-�iEy ��15/12(is)
Stefan K. Matthes, P.E.
Print Name
Culpepper & Terpening, Inc.
38723
Cert # & Co. Cert Auth.
2980 South 25th Street Ft. Pierce, FL 34981
Company Name & Address
Al �'%%% Note• AASHTO LRFD Bridge Design Specs., 7 Ed. with
11111
2fFU7rWED=Structures Design Manual
1 <.
N
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: Pepper Park Boardwalks
Project Address: SRA-1-A, North Beach Pepper Park, St. Lucie County
Permit#: Occupancy Type: Construction
e This certification must be completed, signed, and sealed by the design professional of record.
o Submit (2) copies for residential, (3) copies for commercial with all permi a�lrlvin foil PY
o New Residences (single ormultl-family)
i
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
2014 Building Sth Edition
1. DESIGN CODE: Florida g Code2-010. Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): _Enclosed _Partially Enclosed X Open
3. Risk Category: _I X II _III —IV Exposure Category: _B X C _D
4. Design Wind Velocity 170 mph _ASO X LRFD End Zone Width: N/A ft
5. Mean Roof Height N/A ft Roof Pitch: N/A :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): N/A
Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage:
JZ
7. Design Loads: Floor: N/A PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony: N/A PSF Q
N/A N/A SOLb/LF Q
Dock: 30 PSF Deck: 90 PSF Stairs: PSF Fence: PSF Railings: PSF �O
� n
8. Were Shear Walls Considered For Structure? Yes g,NotApplicable Explain Why Not: ai 0j O
U ti
This is for a boardwalk which does not have walls 2 C.,
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: cCZ C0 ^'
C tm
10. Design Soil Bearing Pressure: See Below PSF Soil Test Reports Submitted? Yes Q�
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
corrkqoWt�i�tFILaftk; ble structural portions of the building codes currently adopted and enforced by St. Lucie
(Dtlr*. y@IQVI%$t%Vtructural elements depicted on these plans provide adequate resistance to the design
C h 0 Stefan K. Matthes Fla PE, 38723
%pj; NO 38723 :N;
* 1 * Print Name Cert # & Co. Cert Auth.
-p-* I I _ ; CrC Culpepper & Terpening, Inc.
+���e�.' p yt��� 2980 South 25th Street, Ft. Pierce, F134981
rim �� ...... C` Company Name & Address
AL
SLCCDV MAIN# I)WI! Revised 3/15/12 (IS)
Pile support design is based upon a conservative effective unit weight of 100 pcf - 62.4 pcf with a resultant 37.6 pcf, 28 degree
friction angle and SPT blow count, N=5 blows/Ft.