HomeMy WebLinkAboutREVIEW COMMENTS�'.�uaie �iocm� Planning & Development Services Building 8 Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(T72)462.6d43 REVIEW COMMENTS S(:HNNtL, BY St. Lucie Crnln+ 1 Address: 3375 N Al a (Pepper Park W Of Ala) Owner(s): St Lucie County City / State / Zip: Fort Pierce, FI 34949 Parcel #: 1425-220-0003-000/5 Jurisdiction: SAINT LUCIE COUNTY Zoning: I Lot#: 1 Block: APPLICATION INFORMATION Permit Number: 1702-0130 Stories: Automatic Sprinkler System? No Permit Type: DOCK CONTRACTOR INFORMATION Contractor Name: Steve B Greenman Fax Number: 772-337-0294 Business Name: Underwater Engineering Services Inc Email: Tpeterson@Uesi.Com Business Addr: 3306 Enterprise Rd Ste 203 City / State / Zip: Port St Lucie, FI 34962 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released ENVIRONMENTAL REVIEW COMPLETE Ben Balcer 2/812017 219/2017 21912017 Comment: FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 2/712017 21712017 2/712017 Comment: PLANS EXAMINER REVIEW INCOMPLETE Joe Clclo 2110/2017 2/1012017 Comment: PLAN SHEET AND ST LUCIE COUNTY"DESIGN LOAD COMPLIANCE SHEETS" MUST BE DESIGNED TO THE 2014 FLORIDA BUILDING CODE, 5TH EDITION Comment: AASHTO SPECS AND FDOT SPECS ARE NOT REFERENCE STANDARDS TO THE BUILDING CODE •• SEE 2/10/2017 CHAPTER 35 REFERENCE STANDARDS' WE DO NOT REVIEW TO FDOT OT BRIDGE STANDARDSPLEASE REMOVE ALL REFERANCE NOTES TO FDOT OR AASHTO SPECS FROM THE STRUCTURAL PLANS 2/10/2017 Comment: IDENTIFY THE EXPOSURE CATEGORY ON" CERTIFICATION FORM" PER FBC 1609.4.3 FOR THE INCREASED PRESSURES 2/10/2017 Comment: IDENTIFY ALL UNIFORM AND / OR CONCENTRATED APPLICABLE LOADS ON THE" CERTIFICATION SHEET" PER FBC TABLE 1607.1 2/10/2017 Comment: IDENTIFY THE GEOTEC LOAD BEARING VALUE OF THE SOILS PER FBC 1603.1.6 ON THE " CERTIFICATION SHEETS"OR PLANS 2/10/2017 Comment: HANDRAILS AND GUARDRAILS MUST BE DESIGNED TO FBC 1607.8.1 2/10/2017 Comment: IDENTIFY THE RISK CATEGORY ON PLANS / CERTIFICATION SHEETS FBC 1604.5 2/10/2017 Comment: ENGINEER TO COMPLETE ITEM #2 ON DESIGN LOAD SHEET PER ASCE7-10 CRITERIA 2/10/2017 Comment: COMMENTS E-MAILED TO MATT AS OF THIS DATE 2/10/2017 Comment: PLEASE RESUBMIT ALL REQUIRED DOCUMENTS IN DUPLICATE Planning 8 Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(72)462-6443 ZONING REVIEW Comment: REVIEW COMMENTS COMPLETE Lydia Galbraith 2/8/2017 21912017 219/2017