HomeMy WebLinkAboutREVIEW COMMENTS�'.�uaie �iocm�
Planning & Development Services
Building 8 Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34982
Phone:(772)462.2172 Fax:(T72)462.6d43
REVIEW COMMENTS
S(:HNNtL,
BY
St. Lucie Crnln+
1
Address:
3375 N Al a (Pepper Park W Of Ala) Owner(s):
St Lucie
County
City / State / Zip:
Fort Pierce, FI 34949
Parcel #:
1425-220-0003-000/5 Jurisdiction: SAINT LUCIE COUNTY
Zoning:
I Lot#: 1 Block:
APPLICATION INFORMATION
Permit Number:
1702-0130 Stories: Automatic Sprinkler System? No
Permit Type:
DOCK
CONTRACTOR INFORMATION
Contractor Name:
Steve B Greenman Fax Number: 772-337-0294
Business Name:
Underwater Engineering Services Inc
Email: Tpeterson@Uesi.Com
Business Addr:
3306 Enterprise Rd Ste 203
City / State / Zip:
Port St Lucie, FI 34962
REVIEWS AND COMMENTS
Review Type
Status Reviewed By Date Started Date Completed Date Released
ENVIRONMENTAL REVIEW COMPLETE Ben Balcer 2/812017 219/2017 21912017
Comment:
FRONT COUNTER REVIEW COMPLETE Audrey Humphrey 2/712017 21712017 2/712017
Comment:
PLANS EXAMINER REVIEW INCOMPLETE Joe Clclo 2110/2017
2/1012017
Comment: PLAN SHEET AND ST LUCIE COUNTY"DESIGN LOAD COMPLIANCE SHEETS" MUST BE DESIGNED TO
THE 2014 FLORIDA BUILDING CODE, 5TH EDITION
Comment: AASHTO SPECS AND FDOT SPECS ARE NOT REFERENCE STANDARDS TO THE BUILDING CODE •• SEE
2/10/2017
CHAPTER 35 REFERENCE STANDARDS' WE DO NOT REVIEW TO FDOT OT BRIDGE STANDARDSPLEASE
REMOVE ALL REFERANCE NOTES TO FDOT OR AASHTO SPECS FROM THE STRUCTURAL PLANS
2/10/2017
Comment: IDENTIFY THE EXPOSURE CATEGORY ON" CERTIFICATION FORM" PER FBC 1609.4.3 FOR THE
INCREASED PRESSURES
2/10/2017
Comment: IDENTIFY ALL UNIFORM AND / OR CONCENTRATED APPLICABLE LOADS ON THE" CERTIFICATION SHEET"
PER FBC TABLE 1607.1
2/10/2017
Comment: IDENTIFY THE GEOTEC LOAD BEARING VALUE OF THE SOILS PER FBC 1603.1.6 ON THE " CERTIFICATION
SHEETS"OR PLANS
2/10/2017
Comment: HANDRAILS AND GUARDRAILS MUST BE DESIGNED TO FBC 1607.8.1
2/10/2017
Comment: IDENTIFY THE RISK CATEGORY ON PLANS / CERTIFICATION SHEETS FBC 1604.5
2/10/2017
Comment: ENGINEER TO COMPLETE ITEM #2 ON DESIGN LOAD SHEET PER ASCE7-10 CRITERIA
2/10/2017
Comment: COMMENTS E-MAILED TO MATT AS OF THIS DATE
2/10/2017
Comment: PLEASE RESUBMIT ALL REQUIRED DOCUMENTS IN DUPLICATE
Planning 8 Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL. 34982
Phone:(772)462.2172 Fax:(72)462-6443
ZONING REVIEW
Comment:
REVIEW COMMENTS
COMPLETE Lydia Galbraith 2/8/2017 21912017 219/2017