Loading...
HomeMy WebLinkAboutREVIEW COMMENTSv Planning 8, Development Services Building &Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982. Phone:(772)462.2172 Fax:(772)46246443 Address: 8243 Business Park Or City / State / Zip: Port St Lucie, FI 34952 Parcel#: 3426-702-0004-000/0 Zoning: PNRD APPLICATION INFORMATION Permit Number: 1703-0686 Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Raxcie L Ledgister Business Name: Dlr General Construction Inc Business Addr: 134 Ne Jettie Terr City / State / Zip: Port St Lucie, Fill 34983 REVIEWS AND COMMENTS Review Type DOCUMENTS MISSING 3/31/2017 Comment: 3/31/2017 Comment: 3/3112017 Comment: i FIRE DEPARTMENT REVIEW Comment: FRONT COUNTER REVIEW Comment: PE REVIEW COMMENTS (2) Comment: 4/4/2017 Comment 4/4/2017 4/13/2017 Comment: 4/13/2017 Comment: i 1 4/13/2017 Comment: REVIEW COMMENTS SCAvlyti_ oUANNED B , B\ RV `S11PLAUP i .r,. Owner(s): A Holdings 1000 Llc Jurisdiction: ST LUCIE COUNTY Lot#: S 12' 2, Block: ALL3,4 Stories: Automatic Sprinkler System? No Fax Number: 772-873-2311 Status Reviewed By Date Started PENDING Lashahna Ingram NEEDS NOC NEEDS SUB FOR PLUMBING NEEDS SUB FOR ELECTRIC PENDING Tony Jerger COMPLETE Lashahna Ingram 3/31/2017 INCOMPLETE Joe Ciclo 511512017 Email: Rledgister2@Gmail.Com Date Comoleted Date Released 3/3112017 3/3112017 SHOW THE LOCATION ON THE FRONT BUILDING ELEVATION FOR THE MALTESE CROSS PER F.A.C.69A- 60.0081 "THE MALTESE CROSS IS THE FIRE SYMBOL AS STATED FAC 69A-60.0081 ' THIS MUST BE POSTED ON THE FRONT ELEVATION OF THE SPACE PER DIRECTION OF THIS SECTION PROVIDE VERTICAL ACCESSIBILITY TO THE STAGE AND CHOIR AREA PER FBC ACCESSIBILITY 206.2.6 SECOND REVIEW "' WE DO NOT GRANT EXCEPTIONS TO THE ACCESSIBILITY CODES I DESIGN PROFESSIONAL MAY NOTE ON PLANS THE SPECIFIC CODE SECTIONS OR OTHER CRITERIA WHICH EXEMPTS CHURCHES FROM THIS CODE ARCHITECT TO INCLUDE AN INTERIOR FINISHES TABLE ON PLANS PER FBC 808.9 "' TABLE 803.9 UPON RE -SUBMITTAL DESIGN PROFESSIONAL TO SUBMIT A BREAKDOWN SHEET ADDRESSING COMMENTS BY ALL REVIEWERS COMMENTS E-MAILED AS OF THIS DATE r %G• f.laG1G l/Oi.as.� Planning B Development Services REVIEW COMMENTS Building& Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462.6443 3 Comment: ***ARCHITECT TO CALCULATE THE OCCUPANT LOAD FOR ALL AREAS OF THE TENANT SPACE PER FBC 511212017 TABLE 1004.1.2 ON THE NET AREA PER FBC DEFINITIONS IN CHAPTER 2 `SHOW THE SQ.FTG AND OCCUPANT COUNT BREAKDOWN ON PLANS FOR THE LOBBY[ STANDING SPACE ] , OFFICE, PULPIT AND STORAGE AREAS • UN -FIXED SEATS ARE 7 S.F. PER PERSON IN THE ASSEMBLY AREAS 5/15/2017 Comment: SEE FBC 1028.9 FOR ASSEMBLY AISLE WIDTH / 24" WIDTHS DO NOT COMPLY 5/15/2017 Comment: DESIGN PROFESSIONAL TO SHOW THE REQUIRED CORRIDOR AND OPENING RATING ON PLANS PER FBC TABLE 1018.1 FOR THE REAR CORRIDOR 5/15/2017 Comment: SECOND REVIEW COMMENTS E-MAILED AS OF THIS DATE PLANS EXAMINER ELECTRIC INCOMPLETE Carl Peterson 411812017 4/18/2017 Comment: PLEASE FURNISH A PANEL SCHEDULE PER 107.2.1 OF THE FLORIDA BUILDING CODE PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 411712017 411812017 4118/2017 Comment: PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 4/4/2017 4/4/2017 Comment: PLEASE SHOW CORRECTED OCCUPANT LOAD PER SECTION 403 FLORIDA PLUMBING CODE 2014 1. 4/4/2017 Comment: PLEASE SHOW THE REQUIRED TWO WATER CLOSETS FOR THE FEMALE RESTROOM PER TABLE 403.1 FLORIDA PLUMBING CODE PLANS EXAMINER REVIEW COMPLETE Joe Cicio 4/312017 511212017 5/12/2017 Comment: ZONING REVIEW COMPLETE Lydia Galbraith 3/31/2017 3131/2017 313112017 Comment: Planning 8 Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 8243 Business Park Dr City / State / Zip: Port St Lucie, FI 34952 Parcel#: 3426-702-0004.000/0 Zoning: PNRD r i 'APPLICATION INFORMATION i f Permit Number: 1703-0686 Permit Type: COMMERCIAL RENOVATION Contractor Name: Raxcie L Ledgister Business Name: Dlr General Construction Inc Business Addr: 134 Ne Jettie Terr City / State / Zip: Port St Lucie, FI 34983 REVIEW COMMENTS SCANNED BY St. Lucie Countv 1 Owner(s): FI Holdings 1000 Llc Jurisdiction: ST LUCIE COUNTY Lot#: S 12' 2, Block: ALL3,4 Stories: Automatic Sprinkler System? No Fax Number: 772-873-2311 Email: Rledgister2@Gmail.Com REVIEWS AND COMMENTS Review Tvoe Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram { 3/3112017 Comment: NEEDS NOC 3/31/2017 Comment: NEEDS SUB FOR PLUMBING 3/31/2017 Comment: NEEDS SUB FOR ELECTRIC FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 3/31/2017 313112017 3131/2017 Comment: PLANS EXAMINER ELECTRIC INCOMPLETE Carl Peterson 411812017 4118/2017 Comment: PLEASE FURNISH A PANEL SCHEDULE PER 107.2.1 OF THE FLORIDA BUILDING CODE PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 4117/2017 4118/2017 4/18/2017 Comment: PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 41412017 4/4/2017 Comment: PLEASE SHOW HIGH LOW DRINKING FOUNTAIN PER SECTION 211 FLORIDA ACCESSABILITY CODE 2014 4/4/2017 Comment: PLEASE SHOW HOT WATER TO ALL SINKS PER 607.1 FLORIDA PLUMBING CODE 2014 4/4/2017 Comment: PLEASE SHOW CORRECTED OCCUPANT LOAD PER SECTION 403 FLORIDA PLUMBING CODE 2014 4/4/2017 Comment: PLEASE SHOW SERVICE SINK PER TABLE 403.1 FL PLUMBING CODE I iti �cfGZG UDx`����ry� Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462.6443 REVIEW COMMENTS Page 2 414/2017 Comment: PLEASE SHOW THE REQUIRED TWO WATER CLOSETS FOR THE FEMALE RESTROOM PER TABLE 403.1 FLORIDA PLUMBING CODE PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 41312017 Comment: IS THIS TENANT SPACE SPRINKLED 77 [ ARCHITECT TO NOTE ON PLANS ] / IF NOT [ ARCHITECT TO NOTE 4/3/2017 ON PLANS ] , TENANT SEPARATION WALLS MUST BE DESIGNED AS 2 HOUR RATED PARTITIONS • SHOW ALL TESTING DETAILS AND TEST NUMBERS ON PLANS " [ SEE FBC TABLE 508.4 ] 4/3/2017 Comment: ARCHITECT TO STATE THE CONSTRUCTION TYPE ON PLANS • FBC SECTION 602 Comment: ARCHITECT TO CALCULATE THE CORRECT OCCUPANT LOADS ON PLANS PER FBC TABLE 1004.1.2 / USE 4/3/2017 EITHER 7,5 OR 15 S.F.P.P. PER TABULAR VALUES, UNFIXED SEATS [ MUST HAVE AN OCCUPANT LOAD BREAKDOWN FOR ALL AREAS 4/3/2017 Comment: ARCHITECT TO CALCULATE THE MEANS OF EGRESS DOOR SIZING SIZES ON PLANS PER THE CALCULATED OCCUPANT LOADING' FBC 1005.3.2 4/3/2017 Comment: SUBMIT LIFE SAFETY PLANS W/ ALL TRAVEL DISTANCES FBC 1014.3 4/4/2017 Comment: SHOW THE LOCATION ON THE FRONT BUILDING ELEVATION FOR THE MALTESE CROSS PER F.A.C.69A- 60.0081 4/4/2017 Comment: CHOIR RISER IS NOT PER CODE • SEE FBC 1009.7.2 4/4/2017 Comment: PROVIDE VERTICAL ACCESSIBILITY TO THE STAGE AND CHOIR AREA PER FBC ACCESSIBILITY 206.2.6 4/4/2017 Comment: ARCHITECT TO SHOW THE REQUIRED INSIDE MANUEVERING CLEARANCES [ CLEAR FLOOR SPACES ] ON PLANS FOR THE RESTROOM DOORS AND ALL RESTROOM FIXTURES' SEE FBC ACCESSIBILITY 404.2.4.1 4/4/2017 Comment: ARCHITECT TO SHOW ALL ACCESSIBLE RESTROOM DETAILS ON PLANS LE: DISPENSOR HEIGHTS, GRAB BAR HEIGHTS ETC FOR BOTH RESTROOMS 4/4/2017 Comment: SHOW THE REQUIRED NON-ABSORBANT WALL COVERINGS ON PLANS FOR THE RESTROOMS AND SERVICE SINK AREAS `SEE FBC 1210.2.1 AND 1210.2.2 4/12/2017 Comment: SHOW THE TEST STANDARDS ON PLANS FOR THE GYPSUM BOARD WI ACCESORIES' SEE FBC 2506.2 4/1212017 Comment: ARCHITECT TO SHOW THE MARKING AND IDENTIFICATION ON PLANS FOR THE REQUIRED SIGNS OR STENCILLING IN THE ABOVE CEILING AREA' SEE FBC 703.7' DESIGN PER CODE 4/1312017 Comment: ARCHITECT TO INCLUDE THE ACCOUSTICAL CEILING W/ METAL GRID TESTING STANDARDS ON PLANS PER FBC 808 WI DETAILS FOR INSTALLATION 4/1312017 Comment: ARCHITECT TO SHOW THE FLAME SPREAD AND SDI FOR THE INSULATION ON PLANS PER FBC 720 4/13/2017 Comment: ARCHITECT TO INCLUDE AN INTERIOR FINISHES TABLE ON PLANS PER FBC 808.9 4/13/2017 Comment: DOUBLE 30" DOORS IN THE MEANS OF EGRESS ARE NOT COMPLIANT WITH FBC 1008.1.1 /ARCHITECT TO CORRECT 4/13/2017 Comment: UPON RE -SUBMITTAL DESIGN PROFESSIONAL TO SUBMIT A BREAKDOWN SHEET ADDRESSING COMMENTS BY ALL REVIEWERS 4/1312017 Comment: COMMENTS E-MAILED AS OF THIS DATE ZONING REVIEW COMPLETE Lydia Galbraith 3131/2017 3/31/2017 3/31/2017 Comment: Planning 8, Development Services Building & Code Regulation. Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462-6443 Address: 8243 Business Park Dr City I State I Zip: Port St Lucie, FI 34952 Parcel#: 3426-702-0004-000/0 Zoning: PNRD REVIEW COMMENTS SGANNED BY St. Lucie Countv Owner(s): FI Holdings 1000 Llc Jurisdiction: ST LUCIE COUNTY Lot#: S 12- 2, Block: ALL3,4 1 APPLICATION INFORMATION Permit Number: 1703-0686 Stories: Automatic Sprinkler System? No Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Raxcie L Ledgisler Fax Number: 772-873-2311 Business Name: Dlr General Construction Inc Business Addr: 134 Ne Jettie Terr Email: Rledgistet2@Gmail.Com City / State / Zip: Port St Lucie, FI 34983 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 3/31/2017 Comment: NEEDS NOC 3/31/2017 Comment: NEEDS SUB FOR PLUMBING 3/31/2017 Comment: NEEDS SUB FOR ELECTRIC FIRE DEPARTMENT REVIEW PENDING Tony Jerger ( Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 3/3112017 313112017 3/31/2017 Comment: PLANS EXAMINER ELECTRIC INCOMPLETE Carl Peterson 4/18/2017 4/18/2017 Comment: PLEASE FURNISH A PANEL SCHEDULE PER 107.2.1 OF THE FLORIDA BUILDING CODE PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 4/1712017 4118/2017 4/18/2017 Comment: PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 4/4/2017 4/4/2017 Comment: PLEASE SHOW HIGH LOW DRINKING FOUNTAIN PER SECTION 211 FLORIDA ACCESSABILITY CODE 2014 4/4/2017 Comment: PLEASE SHOW HOT WATER TO ALL SINKS PER 607.1 FLORIDA PLUMBING CODE 2014 4/4/2017 Comment: PLEASE SHOW CORRECTED OCCUPANT LOAD PER SECTION 403 FLORIDA PLUMBING CODE 2014 4/4/2017 Comment: PLEASE SHOW SERVICE SINK PER TABLE 403.1 FL PLUMBING CODE .a-1 4o0= Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:.(772)462.2172 Fax:(772)462.6443 REVIEW COMMENTS 4/4/2017 Comment: PLEASE SHOW THE REQUIRED TWO WATER CLOSETS FOR THE FEMALE RESTROOM PER TABLE 403.1 FLORIDA PLUMBING CODE PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 41312017 Comment: IS THIS TENANT SPACE SPRINKLED ?? [ ARCHITECT TO NOTE ON PLANS ) / IF NOT [ ARCHITECT TO NOTE 4/3/2017 ON PLANS ) , TENANT SEPARATION WALLS MUST BE DESIGNED AS 2 HOUR RATED PARTITIONS' SHOW ALL TESTING DETAILS AND TEST NUMBERS ON PLANS •• [ SEE FBC TABLE 508.41 4/3/2017 Comment: ARCHITECT TO STATE THE CONSTRUCTION TYPE ON PLANS' FBC SECTION 602 Comment: ARCHITECT TO CALCULATE THE CORRECT OCCUPANT LOADS ON PLANS PER FBC TABLE 1004.1.21 USE 4/3/2017 EITHER 7,5 OR 15 S.F.P.P. PER TABULAR VALUES, UNFIXED SEATS [ MUST HAVE AN OCCUPANT LOAD BREAKDOWN FOR ALL AREAS 4/3/2017 Comment: ARCHITECT TO CALCULATE THE MEANS OF EGRESS DOOR SIZING SIZES ON PLANS PER THE CALCULATED OCCUPANT LOADING • FBC 1005.3.2 4/3/2017 Comment: SUBMIT LIFE SAFETY PLANS W/ ALL TRAVEL DISTANCES FBC 1014.3 4/4/2017 Comment: SHOW THE LOCATION ON THE FRONT BUILDING ELEVATION FOR THE MALTESE CROSS PER F.A.C.69A- 60.0081 414/2017 Comment: CHOIR RISER IS NOT PER CODE • SEE FBC 1009.7.2 4/4/2017 Comment: PROVIDE VERTICAL ACCESSIBILITY TO THE STAGE AND CHOIR AREA PER FBC ACCESSIBILITY 206.2.6 4/4/2017 Comment: ARCHITECT TO SHOW THE REQUIRED INSIDE MANUEVERING CLEARANCES [ CLEAR FLOOR SPACES ] ON PLANS FOR THE RESTROOM DOORS AND ALL RESTROOM FIXTURES • SEE FBC ACCESSIBILITY 404.2.4.1 4/4/2017 Comment: ARCHITECT TO SHOW ALL ACCESSIBLE RESTROOM DETAILS ON PLANS I.E: DISPENSOR HEIGHTS, GRAB BAR HEIGHTS ETC FOR BOTH RESTROOMS 4/4/2017 Comment: SHOW THE REQUIRED NON-ABSORBANT WALL COVERINGS ON PLANS FOR THE RESTROOMS AND SERVICE SINK AREAS `SEE FBC 1210.2.1 AND 1210.2.2 4/12/2017 Comment: SHOW THE TEST STANDARDS ON PLANS FOR THE GYPSUM BOARD W/ ACCESORIES • SEE FBC 2506.2 4/1212017 Comment: ARCHITECT TO SHOW THE MARKING AND IDENTIFICATION ON PLANS FOR THE REQUIRED SIGNS OR STENCILLING IN THE ABOVE CEILING AREA • SEE FBC 703.7' DESIGN PER CODE 4/13/2017 Comment: ARCHITECT TO INCLUDE THE ACCOUSTICAL CEILING W/ METAL GRID TESTING STANDARDS ON PLANS PER FBC 808 W/ DETAILS FOR INSTALLATION 4/13/2017 Comment: ARCHITECT TO SHOW THE FLAME SPREAD AND SDI FOR THE INSULATION ON PLANS PER FBC 720 4/13/2017 Comment: ARCHITECT TO INCLUDE AN INTERIOR FINISHES TABLE ON PLANS PER FBC 808.9 4/1312017 Comment: DOUBLE 30" DOORS IN THE MEANS OF EGRESS ARE NOT COMPLIANT WITH FBC 1008.1.1 /ARCHITECT TO CORRECT 4/1312017 Comment: UPON RE -SUBMITTAL DESIGN PROFESSIONAL TO SUBMIT BREAKDOWN SHEET ADDRESSING COMMENTS BY ALL REVIEWERS 4/13/2017 Comment: COMMENTS E-MAILED AS OF THIS DATE ZONING REVIEW COMPLETE Lydia Galbraith 3/3112017 3/3112017 313112017 Comment: r �f.GrG1r✓ UOw�wv� Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:V72)462.2172 Fax:(772)462-6443 .PROPERTY INFORMATION Address: 8243 Business Park Dr City / State / Zip: Port St Lucie, FI 34952 Parcel#: 3426-702-0004-000/0 Zoning: PNRD APPLICATION INFORMATION Permit Number: 1703-0686 REVIEW COMMENTS SGANNELj BY St. Lucie Countv 1 Owner(s): FI Holdings 1000 Llc Jurisdiction: ST LUCIE COUNTY Lot#: S 12' 2, Block: ALL3,4 Stories: Automatic Sprinkler System? No Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION I Contractor Name: Raxcie L Ledgister Fax Number: 772-873-2311 Business Name: Dlr General Construction Inc Business Addr: 134 Ne Jettie Terr Email: Rledgiste2@Gmail.Com City / State / Zip: Port St Lucie, FI 34983 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Lashahna Ingram 3/31/2017 Comment: NEEDS NOC 3/31/2017 Comment: NEEDS SUB FOR PLUMBING 3/31/2017 Comment: NEEDS SUB FOR ELECTRIC FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 3131/2017 313112017 313112017 Comment: PLANS EXAMINER ELECTRIC PENDING Carl Peterson Comment: PLANS EXAMINER MECHANICAL PENDING Carl Peterson Comment: PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 4/412017 4/4/2017 Comment: PLEASE SHOW HIGH LOW DRINKING FOUNTAIN PER SECTION 211 FLORIDA ACCESSABILITY CODE 2014 4/4/2017 Comment: PLEASE SHOW HOT WATER TO ALL SINKS PER 607.1 FLORIDA PLUMBING CODE 2014 4/4/2017 Comment: PLEASE SHOW CORRECTED OCCUPANT LOAD PER SECTION 403 FLORIDA PLUMBING CODE 2014 4/4/2017 Comment: PLEASE SHOW SERVICE SINK PER TABLE 403.1 FL PLUMBING CODE Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982. Phone:]772)4622172 Fax:[7772]462-6443 REVIEW COMMENTS 2 4/4/2017 Comment: PLEASE SHOW THE REQUIRED TWO WATER CLOSETS FOR THE FEMALE RESTROOM PER TABLE 403.1 FLORIDA PLUMBING CODE PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 413/2017 Comment: IS THIS TENANT SPACE SPRINKLED ?? [ ARCHITECT TO NOTE ON PLANS ] I IF NOT [ ARCHITECT TO NOTE 4/3/2017 ON PLANS ] , TENANT SEPARATION WALLS MUST BE DESIGNED AS 2 HOUR RATED PARTITIONS' SHOW ALL TESTING DETAILS AND TEST NUMBERS ON PLANS ** [ SEE FBC TABLE 508.41 4/3/2017 Comment: ARCHITECT TO STATE THE CONSTRUCTION TYPE ON PLANS' FBC SECTION 602' " Comment: ARCHITECT TO CALCULATE THE CORRECT OCCUPANT LOADS ON PLANS PER FBC TABLE 1004.1.2 / USE 413/2017 EITHER 7,5 OR 15 S.F.P.P. PER TABULAR VALUES, UNFIXED SEATS [ MUST HAVE AN OCCUPANT LOAD BREAKDOWN FOR ALL AREAS 4/3/2017 Comment: ARCHITECT TO CALCULATE THE MEANS OF EGRESS DOOR SIZING SIZES ON PLANS PER THE CALCULATED OCCUPANT LOADING * FBC 1005.3.2 4/3/2017 Comment: SUBMIT LIFE SAFETY PLANS W/ ALL TRAVEL DISTANCES FBC 1014.3 4/4/2017 Comment: SHOW THE LOCATION ON THE FRONT BUILDING ELEVATION FOR THE MALTESE CROSS PER F.A.C.69A- 60.0081 4/4/2017 Comment: CHOIR RISER IS NOT PER CODE' SEE FBC 1009.7.2 4/4/2017 Comment: PROVIDE VERTICAL ACCESSIBILITY TO THE STAGE AND CHOIR AREA PER FBC ACCESSIBILITY 206.2.6 4/4/2017 Comment: ARCHITECT TO SHOW THE REQUIRED INSIDE MANUEVERING CLEARANCES [ CLEAR FLOOR SPACES ] ON PLANS FOR THE RESTROOM DOORS AND ALL RESTROOM FIXTURES' SEE FBC ACCESSIBILITY 404.2.4.1 4/4/2017 Comment: ARCHITECT TO SHOW ALL ACCESSIBLE RESTROOM DETAILS ON PLANS LE: DISPENSOR HEIGHTS, GRAB BAR HEIGHTS ETC FOR BOTH RESTROOMS 4/4/2017 Comment: SHOW THE REQUIRED NON-ABSORBANT WALL COVERINGS ON PLANS FOR THE RESTROOMS AND SERVICE SINK AREAS * SEE FBC 1210.2.1 AND 1210.2.2 4/1212017 Comment: SHOW THE TEST STANDARDS ON PLANS FOR THE GYPSUM BOARD W/ ACCESORIES * SEE FBC 2506.2 4/12/2017 Comment: ARCHITECT TO SHOW THE MARKING AND IDENTIFICATION ON PLANS FOR THE REQUIRED SIGNS OR STENCILLING IN THE ABOVE CEILING AREA' SEE FBC 703.7 * DESIGN PER CODE 4/13/2017 Comment: ARCHITECT TO INCLUDE THE ACCOUSTICAL CEILING W/ METAL GRID TESTING STANDARDS ON PLANS PER FBC 808 W/ DETAILS FOR INSTALLATION 4/13/2017 Comment: ARCHITECT TO SHOW THE FLAME SPREAD AND SDI FOR THE INSULATION ON PLANS PER FBC 720 4/13/2017 Comment: ARCHITECT TO INCLUDE AN INTERIOR FINISHES TABLE ON PLANS PER FBC 808.9 4/13/2017 Comment: DOUBLE 30" DOORS IN THE MEANS OF EGRESS ARE NOT COMPLIANT WITH FBC 1008.1.1 /ARCHITECT TO CORRECT 4/13/2017 Comment: UPON RE -SUBMITTAL DESIGN PROFESSIONAL TO SUBMIT BREAKDOWN SHEET ADDRESSING COMMENTS BY ALL REVIEWERS 4/13/2017 Comment: COMMENTS E-MAILED AS OF THIS DATE ZONING REVIEW COMPLETE Lydia Galbraith 3/31/2017 3131/2017 3131/2017 Comment: