Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONIMM M BV ENGINEERING, INC. MOIA BOWLES VILLAMIZAR & ASSOCIATES www.mbveng.com CA #3728 August 29, 2017 Mr. Joseph Cicio, Plans Examiner St. Lucie County Building Department 2300 Virginia Avenue Ft. Pierce, FL 34982 RECEIVED AUG 9 J 2017 Subject: Roofing at Moose Lodge - 325 Pandora Avenue Fort Pierce, Florida Permit Number: 704-0065 Engineer's Project Number: 17-0077 Dear Mr. Cicio: Mul JI,AI ILL BY St. Lucie rnnntl Below is the information regarding the roofing system at the subject property: Roofing System: Gulf Coast Supply & Manufacturing, LLC GulfPBR, 36" wide with 1 '/4" high ribs, Min. 26 ga. 80 ksi steel Florida Product Approval No. FL 11650.3-R2 Florida Product Approval Uplift Allowable: -40.0 psf (maximum ROOF GIRT spacing of 60" with a fastener pattern of 12"- 12"-12") Design Parameters for FL Building Code 5`h Edition 2014: Wind Speed: 160 mph ultimate, 124 mph allowable (3 sec.) Exp. Category: C, Risk Category: II, Directionality Factor Kd = 0.85 Design Mean Roof Height: 17.17 feet, Kh = 0.87, Edge Zone Width, a = 3.93 feet Design Pressures (DP) in the table below are allowable pounds per square foot for the building. Internal Pressure Coefficient and Enclosure Classification: Main roof = Open, CPI = +/- 0.00 Note: All zones in this project meet the stated maximum allowable design pressures. The 2 x 4 Syp. Pressure Treated No. 2 wood planks shall be spaced at 2.5' o.c. max. at the perimeter (zone 2 and 3) and at 5' o.c. max. in zone 1. Each plank shall be attached with (2) #12 x 3" wood screws at each -truss. -The screws shall be installed with a 1.5" space between them. Plank spacing was determined based on the maximum bending 1250 W. Eau Gallie Blvd., Suite L 1835 20th Street 806 Delaware Avenue Melbourne, FL 32935 Vero Beach, FL 32960 Ft Pierce, FL 34950 321.253.1510 772.569.0035 772.468.9055 Fax:321.253.0911 Fax:772.778.3617 Fax:772.778.3617 759 S. Federal Highway, Suite 200B Stuart, FL 34994 772.266.9795 Fax: 772.778.3617 Mr. Joseph Cicio August 29, 2017 Page 2 of 2 Project Number 17-0077 -, - r-75 rs a ~� capacity of the GULFPBR metal panel as well as the capacity of a 2 x 4 bending along its weak axis. 2. The metal roof panels shall be installed with #10 - 16 x 2" SDS screws with self-sealing washers, attach per FL Product Approval specification and tables below. The fastener spacing at the panel side laps shall be 1/4 - 14 x 7/8" HWH SD screws with self-sealing washers and shall be spaced per the table below. The #10 - 16 x 2" SDS screws were designed for a metal to wood attachment for pullout and pullover. OPEN ROOF AREAS LOCATION FASTENER AT SIDELAP SPACING FASTENER AT RIB SPACING BLDG ALLOWABLE DESIGN PRESSURE (PSF) Zone 1 Interior 20" c/c 12" c/c -32 Zone 2 (Edge) 6" c/c 12" c/c -73 Zone 3 Corner 6" c/e 12" c/c -100' All other installation details shall meet current code requirements and typical construction industry practices. MBV Engineering, Inc. has designed these items utilizing all current and applicable codes and we believe an equivalence of product standards for Florida Product Approval 11650.3 — R2 has been met. The above products and specifications provide adequate resistance to the wind load and forces specified by current code provisions. Please see the attached five pages of engineering calculations for reference. Based on our review of the above products and their pertinent installation details, we deem acceptable the request to install these products. This report was reviewed by Rodolfo Villamizar, P.E., Vice President of MBV Engineering. Should you have any questions regarding the above subject, please feel free to contact our office at any time. \01I I I I I/ I, \N GE SC . Sincerely, �Q�4?`�ENgF �IJ� No.81238 Terence Schlitt, P.l��'. STATE OF W FL PE#81238 l��X1 %- ORID "C2\ TS/cw immsv ENGINEERING, INC. MOIA BOWLES VILLAMIZAR & ASSOCIATES CONSULTING ENGINEERING CA #3728 1835 20TH STREET PROJECT — VERO REACH, FL 32960 _ r (772) 569-0035 L"A-f`�HF•i• www.mbveng.com ADDRESS Melboume (321) 253-1510 Fort Pierce:(772) 468-9055 1611111 1,114,11!, =w DATE DESIGNED CHECKED SHEET NO. SCALE - (9 , rA JCl' S �- - 4JO4- VLA , s�ati LO.�as�C-�-3�..•3(I��(x.(;�a1=3�-s eb-�—���;�a FILE UOPY —Ito =-Z-O r-a3 3 33-s x = 60co (a•s a-) _ -f a s&0 A- -u�1Cs (t� - a,� *-6--------- - iMM By ENGINEERING, INC. MOIA BOWLES VILLAMIZAR & ASSOCIATES CONSULTING ENGINEERING CA #3728 1835 20TH STREET PROJECT VERO BEACH, FL 32960 (772) 569-0035 www.mbveng.com Melboume (321) 253-1510 Fort Pierce: (772) 468-9055 Lw) -a. `LL tbs t0O� ADDRESS Lwj a��Lj L4D DATE DESIGNED CHECKED SHEET NO. p� SCALE wv-z-v-.- j � � At -� AZ&Nis ls. N♦ COMPANY PROJECT Woodworks® SOfTYAR(SOF W000 DFSIC.Y Aug. 28, 2017 09:18 1 Purlin Design Design Check Calculation Sheet Wood Works Sizer 10.42 Loads: Load Type Distribution Pat- Location [ft] Magnitude Unit tern Start End Start End Loadl Wind C&C Full UDL No -417.0 plf Load2 Dead Full UDL No 30.0 plf Load3 Roof live Full UDL Yes 60.0 plf Self -weight Dead Full UDL No 1.4 plf Maximum Reactions (lbs), Bearing Capacities (lbs) and Bearing Lengths (in) : 11 12' 1'-10.8" T-10.8" 5'-10.8" 7'-10.8" 9'-10.8" 11 Unfactored: Dead Wind Roof Live 26 -352 58 69 -915 142 61 -812 139 64 -845 142 61 -812 139 69 -915 142 26 -352 58 Factored: Uplift 195 507 450 468 450 507 195 Total 84 211 200 206 200 211 84 Bearing: Capacity Beam 2966 1730 1730 1730 1730 1730 2966 Support 3284 1211 1211 1211 1211 1211 3284 Anal/Des Beam 0.03 0.12 0.12 0.12 0.12 0.12 0.03 Support 0.03 0.17 0.17 0.17 0.17 0.17 0.03 Load comb #26 #48 #27 #50 #31 #58 #47 Length 1.50 0.50* 0.50* 0.50* 0.50* 0.50* 1.50 Min req'd 0.50* 0.50* 0.50* 0.50* 0.50* 0.50* 0.50* Cb 1.00 1.75 1.75 1.75 1.75 1.75 1.00 Cb min 1.00 1.75 1.75 1.75 1.75 1.75 1.00 Cb support 1.11 1.11 1.11 1.11 1.11 1.11 1.11 Fcp sup 565 625 625 625 625 625 565 *Minimum bearing length setting used: 1/2" for end supports and 1/2" for interior supports Lumber n-ply, S. Pine, No.2, 2x4, 1-ply (1-1/2"x3-1/2") Supports: 1,7 - Lumber n-ply Beam, S. Pine No.2; 2,3,4,5,6 - Timber -soft Beam, D.Fir-L No.2; Total length: 12'; volume = 0.4 cu.ft.; Lateral support: top= at supports, bottom= at supports; Oblique angle: 90.0 deg; R'1 •, r Woodworks® Sizer SOFTWARE FOR WOOD DESIGN Purlin Design Woodworks® Sizer 10.42 Page 2 Analysis vs. Allowable Stress and Deflection using Nos 2012: Criterion Analysis Value Design Value Unit Analysis/Design Shear x-x fv = 0 Fv' = 280 kips fv/Fv' = 0.00 y-y fv = 76 Fv' = 280 psi fv/Fv' = 0.27 Bending(+) x-x fb = 0 Fb' = 1738 kip-ft fb/Fb' = 0.00 y-y fb = 832 Fb' = 1936 kip-ft fb/Fb' = 0.43 Bending(-) x-x fb = 0 Fb' = 1738 kip-ft fb/Fb' = 0.00 y-y fb = 578 Fb' = 1936 kip-ft fb/Fb' = 0.30 Live Defl'n -0.02 = <L/999 0.38 = L/60 in 0.05 Total Defl'n -0.02 = <L/999 0.38 = L/60 in 0.04 Additional Data: FACTORS: F/E(psi)CD CM Ct CL CF Cfu Cr Cfrt Ci Cn LC# Fvy' 175 1.60 1.00 1.00 - - - - 1.00 1.00 - 4 Fby' 750 1.60 1.00 1.00 1.000 1.467 1.10 1.00 1.00 1.00 - 4 Fby'- 750 1.60 1.00 1.00 1.000 1.467 1.10 1.00 1.00 1.00 - 4 Fcp' 565 - 1.00 1.00 - - - - 1.00 1.00 - - E' 1.4 million 1.00 1.00 - - - - 1.00 1.00 - 4 Emin' 0.51 million 1.00 1.00 - - - - 1.00 1.00 - 4 CRITICAL LOAD COMBINATIONS: Shear : LC #4 = .6D+.6W, V = 267, V design = 267 lbs Bending(+): LC #4 = .6D+.6W, M = 91 lbs-ft Bending(-): LC #4 = .6D+.6W, M = 63 lbs-ft Deflection: LC #4 = .6D+.42W (live) LC #4 = .6D+.42W (total) D=dead L=live S=snow W=wind I=impact Lr=roof live Lc=concentrated E=earthquake All LC's are listed in the Analysis output Load Patterns: s=S/2, X=L+S or L+Lr, =no pattern load in this span Load combinations: ASCE 7-10 / IBC 2012 CALCULATIONS: Deflection: EI = 7.50e06 lb-in2 EIy = 1.38e06 lb-in2 "Live" deflection = Deflection from all non -dead loads (live, wind, snow...) Total Deflection = 1.50(Dead Load Deflection) + Live Load Deflection. Lateral stability (+): Lu = 1'-10.75" Le = 3'-5.88" RB = 2.26 Lateral stability (-): Lu = l'-10.75" Le = 3'-5.88" RB = 2.26 Design Notes: 1. Wood Works analysis and design are in accordance with the ICC International Building Code (IBC 2012), the National Design Specification (NDS 2012), and NDS Design Supplement. 2. Please verify that the default deflection limits are appropriate for your application. 3. Continuous or Cantilevered Beams: NDS Clause 4.2.5.5 requires that normal grading provisions be extended to the middle 2/3 of 2 span beams and to the full length of cantilevers and other spans. 4. Sawn lumber bending members shall be laterally supported according to the provisions of NDS Clause 4.4.1. 5. FIRE RATING: Joists, wall studs, and multi -ply members are not rated for fire endurance. : k~ NONEam-1104 T URIP. METAL-To-WooD FASTENERS Product Report No. 02711 ................................................................................................................................... Selector Guide a Drlll & Materialad Dnll Box escnptlon Tap ;Attach"menypp Polnt L - '.z: Stylekw Capacity Ran9e.Fx Oty .. 1271000 9-15 x 1" HWH Sharp .012-.048 0-.250 7,000 Metal wall panel to wood 1272000 9.15 x 1.1/2" HWH Sharp .012-.048 0-350 4,000 structure 1273000 9-15 x 2" HWH Sharp .012-.048 .500-1.250 3,000 1275000 9-15 x 2-1/2" HWH Sharp .012-.048 1.000-1.750 1,500 • Metal panel over insulation to 1276000 9-15 x 3" HWH Sharp .012-.048 1.500-2.250 1,500 wood 1558000 14-10 x 1-1/2" 5/16" AF HWH Type 17 .0 2- 048 .445 3.000 1277000 12.14 x 314" HWH Sharp .012-.048 --- 4,000 • Stitching of metal wall panel WRh-1/2"'handed as er t TSTF5T___9-T5 xSharp .0112,048 0-.250 4,000 • Metal roof and wall panel to 1264053 9.15x1-1/2" HWH Sharp .012-.048 0-.750 2,500 wood 1267053 9-15 x 2" HWH Sharp .012-.048 .500.1.250 2,000 1268053 9-15 x 2-1/2" HWH Sharp .012-.048 0-.250 1,500 • Metal panel over insulation to 1269053 9-15 x 3" HWH Sharp .012-.048 1.500-2.250 1,000 wood 1801053 10.16 x 1" HWH A.P.T. .012-.048 0-.250 2,500 1802053 10-16 x 1-112" HWH A.P.T. .012-.048 0-.750 2,500 1803053 10-16 x 2" HWH A.P.T. .012-.048 .012-.048 2,000 1804053 10.16 x 2-1/2" HWH A.P.T. .012-.048 1.000-1.750 1,500 1805053 10-16 x 3" HWH A.P.T. .012-.048 1.500.2.250 1,000 1525053 14-10 x 1" 5/16" AF HWH Type 17 .012-.048 0-.445 2,500 1526053 14.10 x 1-1/2" 5/16" AF HWH Type 17 .012-.048 0-.750 2000 1270053 12-Nx314" 'HWH Sharp .012-.048 -• 4,000 •Sftlirrlrodandivallpardl -won ana- uu. Berea wasner ................................................................................................................................... Performance Data for a10 Diameter `PULLOUTLVALUESIN STEEL (ab"emgeili uitimlae), Fastener Steel Gauge Dia. 26 24 22 20 18 9 171 252 329 401 634 12 199 271 360 426 656 10 151 238 291 359 478 PULLOUT*VALUES.IN WOOD (avemge Ibs ultimate)*, Fastener Embedment in 2" x 4" Dia. 112" 3/4" 1" 1.114" 1-1/2" 9 198 328 571 728 872 12 210 335 10 256 710 753 1121 1358 The values listed are ultimate averages achieved under laboratory can0 and apply to Buildex manutamured lasteners only. Fppmpdate safety factors should be applied to these values for design purposes. ,1' ',FASTENERLVALUES 'spr' ..,t Fastener (dia-tpi) Tensile (Ibs. min.) Shear (avg.lbs. ult) Torque (min. in. lbs.) 9-15 1800 1200 50 12-14 2778 2000 92 10-16 1927 1200 71 „; PULLOVER VALUES`"(average lhs;ultlmate)'« ' Fastener Steel Gauge Dia. 26 24 22 20 18 9 Unwashered 465 623 815 1049 1549 9 Washered 515 674 875 1100 1627 12 Unwashered 527 699 863 912 1185 12 Washered 587 744 915 993 1246 10 Washered 548 932 1122 1444 1894 '" SHEET STEEL l'*,;` _"GAUGES Gauge No. Decimal Equivalent 18 .048" 20 .036" 22 .030" 24 .024" '26 .018" 28 .015" 30 .012" .................................................................................................................................. Installation Guidelines f.� A standard screwgun with a depth sensitive nosepiece should A� Overdriving may result in torsional failure of the fastener or be used to install TruGrip-. For optimal fastener performance, stripout of the substrate. the screwgun should be a minimum of 6 amps and have an RPM range of 0-2500. At The fastener must penetrate beyond the metal structure a ,2°2 Adjust the screwgun nosepiece to properly seat the fastener. j�1 New magnetic sockets must be correctly set before use. Remove chip build-up as needed. imauddex toile Waef Rn,n KAmur a"amm r _ m of minimum of 3 pitches of thread. Properly Seated Washers UMerNHen Ormn CortV Werddven '. trademarks of ITW Buildex and lilinois Tool 60143 Fax: 630-595.3549 77 ® 2010 nW Buildex and lilinois Tool works, Inc. Ccom "' 34