Loading...
HomeMy WebLinkAboutEVALUATION REPORTRECEIv,:D APR" `t017 O Metal Roof and Wall Systems -)UMNNED BY :+ Illriarnno, OGANNED BY 3t. I uciP County PRODUCT EVALUATION REPORT PBR Wall Panel THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT &IAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES. CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD State of Florida Professional Engineer: Terrence E. Wolfe, P.E. # 44923 19530 Ramblewood Drive Humble, TX 77338 ST. LUCIE COUNTY BUILDrT DIVIOION REVIEWED FOR CO LIAR CE REVIEWED BY crJ DATE PLANS ANVPEPMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE. •20?n ,1111NI•l48I %NCE 1i �Q.'• ENS.'•,( N0.44323 STATE l� ' P •• At - OR •\� APR 2 7 2015 Manufacturer: MBCI, L.P. a division of NCI, L.P. Houston 14031 West Hardy Houston, TX 77064 Lubbock 5711 FM40 Lubbock, TX 79401 Oklahoma City 7000 S. Eastern Ave. Oklahoma City, OK 73149 San Antonio 86771-10 East Converse, TX 78109 Atlanta 2280 Monier Ave. Linda Springs, GA 30122 Richmond 801 South Ave. Colonial Heights, VA 23834 Indianapolis 1780 McCall Drive Shelbyville, IN 46176 Omaha 1011 Ellison Ave. Omaha, NE 68110 Memphis 300 Highway 51 North Hernando, MS 38632 Rome 6168 State Route 233 Rome, NY 13440 Adel 1600 Rogers Road Adel, GA 31620 Phoenix 660 South 91R sheet Tolleson, AZ 85353 Salt Lake City 1155 West 2300 North Salt Lake City, UT 84116 Oskaloosa 515 1P Ave E. Oskaloosa, IA 52577 Atwater 550 Industry Way Atwater, CA 95301 Ennis 1804 Jack McKay Blvd. Ennis, TX 75120 Nlcholasvlllo 6975 Danville Rd. Nicholesville, KY 40340 Skis clRodda C-QA d 26M iGE E, ."** . V • �Q'.• �GENS '•�T: No.44923 STAT�Oj'9 l M SUBJECT: Panel walls, siding DESCRIPTION: PBR — a 36", wide, through fastened, structural, metal wall panel, available in 29-ga. (.015), 26-ga. (.019), 24-ga. (0.023"), or 22-ga. (0.029") ga. PBR is typically applied over open framing. CODE CRITERIA: PER RULE 61G20-3, CHAPTER 14, FLORIDA BUILDING CODE — BUILDING, 5TH EDITION (2014), EXTERIOR WALLS SECTION 1403 PERFORMANCE REQUIREMENTS 1403.3 Structural. Exterior walls, and the associated openings, shall be designed and constructed to resist safely the superimposed loads required by Chapter 16, erm,rq„f, a0.2 s 25M ,AGE E .• G E No.44923` Q� P �• ''�'••.�ORti� G\ SSrOIv'Al 106,41 APR 2 7 2015 LIMITATIONS OF USE FOR NON -HIGH VELOCITY HURRICANE ZONES Substrate: Substrate Description: Substrate Attachment: Insulation: Minimum Substrate Thickness: Steel Girls or FL P.E. designed equal. Designed by FL P.E. per FBC 5th Edition (2014). (Optional) Vinyl or reflective foil faced fiberglass batten insulations that have a flame spread rating of no more than 25 and a smoke development rating of not more than 450. 16-ga purlins or FL P.E. designed equal per FBC 5th Edition (2014). Documentation Supporting the Compliance Statement: The product has been tested in accordance with: ASTM E 1592-01: Test Report 07-0045T-07 A-D, E-H dated 4-03-07 by Force Engineering & Testing, Inc, located in Humble, Texas. The ASTM E 1592-01 test standard is equivalent to the ASTM E 1592-05 test standard. Maximum Uplift Pressure: Application: Test Pressures: See Attached Section Properties & Load Tables Install PBR Panel per the manufacturers approved details. 29 ga. PBR -55 psf, +60 psf @ 4 ft o.c. spans 26 ga. PBR -80 psf, +90 psf @ 4 ft o.c. spans 24 ga. PBR -90 psf, +100 psf @ 4 ft o.c. spans 22 ga. PBR -142.5 psf, +160 psf @ 4 ft o.c. spans �•.•�NGE E. '••,� No.44923 APR 2 7 Go-k O 29ns �G E N SF'+fit tso. Is ' STA •. /ONAL .+ 'pals.....••` ArK 27 2015 KAaux AWN)om-ce UK smm 2 t/x 7' APPLOM FRINARMW PBR PANEL SIDE LAP DETAIL �Y PBR PANEL FASTENER PATTERN (AT INTERMEDIATE SUPPORTS) s _ r s IN PBR PANEL FASTENER PATTERN (AT PANEL ENDS) c" 5.