Loading...
HomeMy WebLinkAboutPROJECT INFORMATIONJ cy- 03 o,:;),! 7-epm i - — File copy I Encon Services. Inc. Job Description PGA Village POA 2140 N.W. Reserve Park Trace Ft. Pierce, FL Signature 46 St SCANNED BY St 1 rrn; n_ Florida Building Code, 5th Edition (2014) ASCE 7-10, Load Case = 0.6W + D Risk Category II Kzt 1 Exposure C J r Kd 0.85 Kz 0.85 „ VULT (MPH) 160 Aaron Biedenbach, P.E. # 52949 VASO(MPH) 124 Date Signed: 6/23/2017 Cf 1.69 G 0.85 1 Wind Pressure (ULT) 68 PSF Sign Area s Distance to Center ft(lb) P = Force Moment (it -lb) Can 1 28.08 5.83 1143 6661 Pole 9.33 1.75 380 665 Totals 1,523 7,326 Required Flexural Strength (kip-ft) 7.33 Provided Flexural Strength (kip-ft) 8.42 HSS 4x4x3/16" Grade A500 B Steel Tube 0.870062 Auger Foundation Design Per Support Diagonal B (FT) 6.00 Base Size Required Lateral soil pressure (LB/SF/FT) 150 4.0 FT Deep Depth (Estimated) (FT) 4 6.0 FT Parallel S1 400 2.5 FT Perpendicular Design Depth (FT) 3.63 Ft Anchor Bolt and Base Plate Design Per Support Distance Between Bolts 9 4884 Tension on Bolts (LB) Number of Bolts per Base Plate 4 Use 1" Dia. F1554 Gr36 Bolts Plate Width B (IN) Bolt Spacing d (IN) Width of Pole (IN) 12 0.67 Plate thickness (IN) 9 Use314' A36 Plate 4 RECE ' 4-� JUN27 2017 6/23/2017 PGA Village POA Ft Pierce Signature 46 Customer 3106356 File Cbpy "covestro Makrolon° SL sheet UV resistant sign grade Makrolon® SL Sign Grade sheet is a polycarbonate product with an advanced UV resistance technology that promotes long lasting outdoor weathering performance. It features outstanding impact strength, excellent dimensional stability, high temperature resistance, and high clarity. This lightweight thermoformable sheet is also easy to fabricate and decorate. Makrolon SL is offered in clear, a wide range of standard sign colors, or can be custom matched to any color. The product, available in either sheet or reels, has a proven track record of outstanding performance in extreme environments and meets the UL 879 standard for electric sign components. A ten (10) year limited product warranty is available for both clear and colors for breakage resistance. Clear sheet is also covered forweathering resistance. The terms of the warranty are available upon request. Applications Flat and formed sign faces and channel letters PDS013 SL0915 Typical Properties Property Test Method Units Values PHYSICAL Specific Gravity ASTM D 792 — 1.2 Refractive Index ASTM D 542 — 1.586 Light Transmission, Clear @0.118" ASTMD 1003 % 86 Light Transmission, 859 White @0.118- ASTM D 1003 % 27 Light Transmission, 354 White @0.1SO- and 0.177- ASTMD 1003 % 27 WaterAbsorpton, 24 hours ASTM D 570 % 0.15 Poisson's Ratio ASTME 132 — 0.38 MECHANICAL Tensile Strength, Ultimate ASTM D638 psi 9.500 Tensile Strength, Yield ASTM D638 psi 9.000 Tensile Modulus ASTM D 638 psi 340.000 Elongation ASTM D 638 % 110 Flexural Strength ASTM D 790 psi 13,500 Flexural Modulus ASTM D 790 psi 345.000 Compressive Strength ASTM D 695 psi 12,500 Compressive Modulus ASTM D 695 psi 345,000 Izod Impact Strength, Notched @ 0.125- ASTM D 256 fli 18 Izod Impact Strength, Unnotched @ 0.125- ASTMD 256 ftibsfln 60(no failure) Instrumented Impact @ 0.125- ASTM D3763 ftlbs >46 Shear Strength, Ultimate ASTM D732 psi 10,000 Shear Strength, Yield ASTM D732 psi 6,000 Shear Modulus ASTM D732 psi 114,000 Rockwell Hardness ASTM D 785 — M70/11118 THERMAL Coefficient of Thermal Expansion ASTM D 696 inAn/°F 3.75 x 10'B Coefficient of Thermal Conductivity ASTMC 177 BTU-in/hrft"F 1.35 Heat Deflection Temperature @ 264 psi ASTMD648 °F 270 Heat Deflection Temperature @ 66 psi ASTM D 648 'F 280 Brittleness Temperature ASTM D 746 -F -200 ELECTRICAL Dielectric Constant @10 His: ASTMD 150 — 2.96 Dielectric Constant @ 60 Hz ASTM D 150 — 3.17 Volume Resistivity ASTM D 257 Ohmcm 8.2x 101' Dissipation Factor @60 Hz ASTMD 150 — 0.0009 Arc Resistance — — — Stainless Steel Strip electrode ASTM D 495 Seconds 10 Tungsten Electrodes ASTM D 495 Seconds 120 Dielectric Strength, in air @0.125- ASTMD 149 V/mil 380 FLAMMABILITY Horizontal Burn, AEB ASTM D 635 in. <1 Flame Class@0.060- UL94 — HE Ignition Temperature, Self ASTM 01929 °F 1022 Ignition Temperature. Flash ASTMD1929 °F 824 e Makrolon° SL Makrolon° SL sheet 9 Impact Resistance* r� >46 10 30 !0 to 0.5 2 n Glass Acrylic Makrolon'SL 'Instrumented Impact per ASTM D 3763. sample thickness 0.125- nominal -Pile CO PY Regulatory code compliance and certifications UL 879: Electric Sign Components, UL File #E146154 UL94: Flammability, UL File #E351891 Miami -Dade NOA #12-0605.05 Florida Building Code 2010 Hiqh Velocitv Hurricane Zone Classified 119 Salisbury Road Sheffield, MA 01257 COVeStfO Toll Free,800.254.1707 Fax: 800.457.3553 sfdinfo@covestro.com sheets.covestro.com ®Copyright Covestro, 2015 Makrolon^ is a registered trademark of Covestro N 7 C 6 y 5 In d 4 C O 3 } 2 } 1 0 UV Weather Resistance Uncoated Polycarbonate , , ' Makrolon'SL Polycarbonate Sheet , Acrylic 0 2 4 6 8 10 Years Visible yellowness at 8 or greater The manner in which you use and me purpose to which you put and utilize our products. technical assistance and Information (whether verbal, mitten or by way of production evaluations). including any suggested formulations and recommendations, are beyond our control.Therefo(e.it isImperativethat you test our products. technical assistance. information and recommendations to determine to your own sadisfacton Mather our products. technical assistance and information are suitable for your intended uses and applications This application -specific analysis must at least include testing to calamine suitabllity, from a technical aswell as realm, safety. and environmental standpoint. Such testing has not necessarily been done by Covestro. assistance, and Information Any statement or recommendation not contained herein Is unauthorized and shall not bind us. Nothing herein shall be consimed as a recommendation to use any product in conflict with any claim of any patent relative to any material or its use No license is implied or In fact granted under the claims of any patent. With respect to health, safety and em4ronment precautions. the relevant Safety Data Sheets(SDS) and product labels must be observed prior to working with our products.