Loading...
HomeMy WebLinkAboutMISC EMAILSCANNED BY St. Lucie Cnnntt, May 12, 2017 PAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pwelchinc@aol.com Re: Shutter Installation 10660 South US Highway 1 Port St. Lucie, FL To Whom It May Concern: RECrz MAY 15 2917 PERfNF�TIu St. Lucie Gouniy, FL Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2014 for the installation of accordion shutters di the above referenced address. Wind speed: Vwt: 165 mph, V.,a: 128 mph Exposure: C Enclosure Type: Enclosed Shutter Size: 92" Maximum Height for Accordion 116" Maximum Width for Roll Up Shutter Location: (See Attached Sketch) Required Design Pressure: +41.2 / -55.2 PSF Shutters to be installed shall be equal to, or exceed the required design pressures as listed above "Required Design Pressure". Shutters shall be installed in accordance with the shutter manufacturer's installation instructions and Florida Product Approval and Florida Building Code 2014. Accordion Shutters shall be FL# 1850.3 Roll Up Shutters shall be FL# 5790.1 Thank you for your attention to this matter. Submitted by: PAUL WELCH INC., Paul Welch, P.E. ,MAY 1 2 7017 Reg. No 29945