Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online R. V LE" I. 1 BCIS Home Log to User Registration Hot Topics submit Surcharge Stats S Facts Publications FBC Staff acts Site Map Units Search 'Ofl�d d b pr � Product USER: PublicAUeer oval THESE PLANS AND ALL PROPOS@D WOPF1 ARE SUBJF.CTTO ANY COP49ECTIONS Proauct Approval Menu> Product or Application Search> Application List> Appliptlon Detail `R>EOUIRED BY FIELD INSP$CTORS THRT .oiL'i�`�i'"V•r FLS Application Type Code Version Application Status SCANNED Comments BY Archived St. Lucie Connhr Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FLI0674-R12 MAY BE NECESSARY IN 014OM TO Revision COMPLY WITH ALL APPLICMXE CCfX8, 2014 Approved `Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owensccrning.com Greg Keeler greg.keeler@owenscarning.com Mel Sancrant 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Roofing Asphalt Shingles as ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COMPLIANCFl DATE MUST Bf_ KEPT ON As OR NO INSPECTION WILL BE MADE Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert J.M. Nieminen CONCEALED FASTENERS OR ATTACHMENTS PE-59166 ARE THE RESPONSIBILITY OF THE UL LLC URACTOROFAECORD 08/20/2017 John W. Knezevich, PE Validation Checklist - Hardcopy Received FL10674 R12 COI 2016 01 COI Nieminen.odf Standard Year ASTM D3161 2009 ASTM D3462 2009 ASTM D7158 2008 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 Vd/o2... 1 /19/2017 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 04/18/2016 04/19/2016 04/20/2016 06/08/2016 FL # Model, Number or Name Description 10674.2 Owens Corning Asphalt Roofing 3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R12 11 2016 04 FINAL ER CC ASPHA 7 SHINGLES FL10674-R12 ndf Approved for use outside HVHZ; Yes Impact Resistant: N/A Verified By: Robert 1. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Parry; Yes Other: Refer to ER, Section 5. Evaluation Reports FL10674 R1204 FINAL ER OC ASPHALT SHINGLES FL10674-R32 odf Created by Independent Third Party: Yes Back Neat Contact Us :: 2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1624 The State of Florida Is an AA/EEO employer. Coovrioht 2007-2013 State of Florida,a: pdvacv Statement :: Accesslbllity Statement:: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a publlarecords request, do not send electronic mail to Nis entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emalls provided may be used for official Communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please pmvitle the Department with an email address which can be made available to the public. To determine ifyou are a Ilceneee under Chapter 455, F.S., please click here . Product Approval Accepts: mm ® yf t[4 Credit Card Safe x:— SCCUI'ItYh1ETRICS r •• � ;�; Copy '- lo http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEV XQwtDgtBNbEY5 Vd/b2... 1/19/2017 TRINITY ER® EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization X9503 353 CHRISTIAN STREET, UNITg13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 037940.02.12-R7 FL10674-R12-gisopius, Date of Issuance:02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the Sul Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles �u>ic��n�erw� LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida OCA ANE1983 CERTIFICATION OF INDEPENDENCE: The facs8nile seal appearing was authorized by Robert Nieminen, P.E, on W/I8/2016. This does not serve as an electronleally signed doament. Signed, sealed hardcophs have been transmitted to she Product Approyal Adm lnistotor and to the named client 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. E TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM 03462 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM 03161 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Entity Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation, R2453 Exp. 08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Devonshire'" are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition Duration', Duration Premium Cool, TruDefinition Duration Designer Color Collection, TruDefinition* Oakridge, Oakridge* and WeatherGuard* HP are fiberglass reinforced, laminated asphalt roof shingles. www� 4.2 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge'" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7 Certificate ofAuthorieotion 09503 FL30674-R12 Revision 7: 04/18/2016 Page 2 of 8 6. OF" LE COPS TRINITY ERA 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R9O5.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph (Volt = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R9O5.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasa = 150 mph (Vass = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G2O-3. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G2O-3, per FBC Sections 1507.2.3, 1507.2.4 or R9O5.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R9O5.2, with the following exceptions: ➢ Berkshire shingles require minimum five (5) nails per shingle. D WeatherGuard HP shingles require minimum six (6) nails per shingle. D DevonshireT" shingles require minimum six (6) nails per shingle. D Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R9O5.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus: Fet underlaywril---ItK Desk Sell mhe,toc k• unhat Underlayment Da'r Ddp edge 9 —Nails located V" 3'4om eave Insta0 first Sellsea6ng adhesive Start&9- C positioned along eave ahingte whh '-., O'remeved $tart& Strip Wngle ovethangs eaves and rakes'/0"A Exterior Research and Design, LLC. Certificate of Authoritarian #9503 Ddp. edge Insult Ent sunar Strip Pin wn 6'rempved---^- Ded Srfl¢dhe,ed woNmLpdv urd.l.,rn.M Rua overhangs eave and rakes 1/4--014' Evaluation Report 037940.02.12-R7 FL10674-R32 Revision 7: 04/18/2016 Page 3 of 11 6.2.6 Minimum Nailing —Classic®&Supreme: Normal M.ns.rd or Area pare Wind Area. High Wind viendor ruart.a Area pere vientor norm Yee SExposum E.Posicidn Fi2.7 Minimum Nailing— Rerkchirce- manoaro rastenine stern TRINITY ERA Normal Mansard or Area pare Wind Areas High Wind d.rvene. y Area pore vientos norm iss Areas vientor raerter tut (A)tz t t 5 5/8' Exposure Exposicidn r Sealer grip / La t➢s de ugador vt" i 81A. e l e 8'A. i 8 %" 6-Nail Fastening Pattern Seabm strip is t6a dr sdlatkr or sesame o.---ya.---tea ,.1 t r i' Asph.1 roelingcem.nt G'rtxnto da teoaa draslatro Mansard or Steep Slope Fastening Pattern FCOP g,trY 'J �atr Exterior Research and Design, LLC. Evaluation Report 037940.02A2-R7 Certificate of Authorization 99503 F1.10674-1112 Revision 7: 04/18/2016 Page 4 of 8 6.2.8 Minimum Nailing —Devonshire'": _ I 7" I 8" I 8" f S. 7" 5-5/8' exposure Sealant location Exposicidn de 5.5/8 pulg Ubicaci6n del sellador TRINITY ERD WAS — sa Ten i" Spols of Asphah Roof Cement Standard 6-Nail Fastening Pattern Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition Duration Designer Color Collection: 4Nall Fastening Pattem aurtxuiiDhmMnBanaMM d Tw.t I w FnY- S.N• Standard Fastening Pattern sw.xnmh".Mnv., .ram 1. ' awu.1 x.e^•a a -In. c—I Mansard or Steep Slope Fastening Pattern 6.Nall Fastening Pattern sunxmimhmrmaw.rmn 2-11-i- 1T 1' 'ue' n��.•-a 6-Nail Fastening Pattern t j a+ni j o,ro4t g f Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R7 Certificate ofAuthorlxation 99503 FL10574-R32 Revision 7: 04/18/2016 Page 5 of 8 6.2.1 Minimum Nailing—TruDefinition Oakridge°, Oakridge°: 4 Nail Patton Esquevna con 4 claws r 1• Imo— 1r —>I N— 1r—•I 5 SIT Exposure Nas 65Exposure &pWdaof 55/BpuO� Clayos Expostonce5 5/Bpufg. Standard Fastening Pattern 6 Nail Pattern Esquema con 6 clavos r r N— a• � fi— 1r Nails Etposi6hde6 4'�ypv E p.si rr mode Eapasicion de 55/BpWg frpasirionM 55/8p Ng 6-Nail Fastening Pattern Fastenlnn for Slopes Greater Than 21:12 Mlesrexnv err•.1N It- e.n. ryry �r vox 1^soon ou.e••n ao.nw c•m•x Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing— WeatherGuard® HP: 1. I I<-- 2' %1�1 �{ •; as Exterior Research and Design, I.I.C. Certificate of Authorization 99503 single sire View Ile" Ybnl 1:611,61milor 1"{! Claaw w Nlits i 4= Evaluation Report 037940.02.12-R7 Ft10674-1112 Revision 7: 04/18/2016 Page 6 of 8 6.3 Hip & Ridge Shineles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles and Pro Edge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of DuraRidger" Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge: Fig. 1 9 r he✓tlWq wnd UteaNn P Hai15 P P I I 9 I I I 1 I P I I i I + + Y e Emosve Fig. 2 ran�ra Smewen Xa's Xd15 Fa �I 1 �I i i 6.3.4 Minimum Nailing— WeatherGuard® HP Hip and Ridge: Fig.A qq emvao— w.md � —DIIMbn P Has�/� \ A 1 1 1 i I I Ya i i I, I ETDOSYR Fig. C Hip & Ridge Shingle Fastening reovbw rlal6 Nalk 2.. a.. - t• 1' 1° t" S• fYFOsunl t ] Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7 Certifltate ofAuthari]anon C9503 FL10674-R12 Revision 7: 04/18/2016 Page 7 of 8 FILE COPY Tnwitt ew 6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles: Prevailing Wind Direction sealant strip i__� 6' Exposure Fasten 71h' Cover Exposed Fasteners with Roof Cement Standard ^71•-^ Fastening Pattern 12' 1 Sealant 7•i,• 6' Exposure {I 1171 I�12•—II 6.3.6 Minimum Nailing— DuraRidge'" Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. Top Vi pee �• Y"M raswerlor i-tl i Ncie: = r" I' Ovrem Cwrinq SureNaT _ Id lea fr a�' Iloc I-z I le 10 �I 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named CIA entity for information on which plants produce products covered by Florida Rule 9N-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625 ; (414) 248-6409; karen.buchmannPul.com - END OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization 99503 FL10674-R12 Revision 7: 04/18/2016 Page 8 of 8 — Florida Building Code Or' `% ge 1 of 2 0P (w FILE BCIS Home I Log In User Registration I Hot Topics I Submit Surcharge S Stats & Facts i Publications i FBC Staff i BCIS Site Map L Rona „'13, Product Approval � USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # FL10450-R8 Application Type Revision THESE PLANS AND ALL PROPOSED WORK Code Version 2014 ARE SUBJFXTTO ANY COMECTIONS Application Status Approved `REOUIRED BY FIELD fNSPfiCTORS THAT SCANNED . MAY BE NECESSASY IN ORM TO Comments Archived BY ❑ COMPLY WITH ALL APPLICABLE CODES, St. Lucie Countv Product Manufacturer Tarco Roofing Address/Phone/Email One Information Way Suite 225 Little Rock, AR 72202 (254)913-7750 smohseen@tarcoroofing.com Authorized Signature Shaik Mohseen smohseen@tarcorooflng.com Technical Representative Shaik Mohseen Address/Phone/Email 2403 Taylors Valley Road Belton, TX 76513 (254) 913-7750 smohseen@tarcoroofing.com Quality Assurance Representative Shaik Mohseen Address/Phone/Email 2403 Taylors Valley Road Belton, TX 78717 (254)939-3775 Ext 210 smohseen@tarcorooflng.com Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licen Professional Engineer ❑ Evaluation Report - Hardcopy Received CONCEALED PAITINERS OR ATTACHMENTS Florida Engineer or Architect Name who developed the Robert Nieminen At THE RESPONSIBILITY OFTHE Floridation Li enseort PE-59166 Quality Assurance Entity UL LLC lf4JUCOWMORD Quality Assurance Contract Expiration Date 10/13/2017 Validated By John W. Knezevich, PE ® Validation Checklist - Hardcopy Received Certificate of Independence FL10450 R8 COI 2016 01 COI Nieminen.ndf Referenced Standard and Year (of Standard) Standard ASTM D1970 ASTM D226 ASTM D3909 ASTM D4869 ASTM D6164 http://www. flon dabuilding. org/pr/pr_app_dtl. aspx?param=wGE VXQwtDqu... 5/ 18/2017 Florida Building Code Orr"= — Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved ASTM D6380 FM 4474 FRSA/TRI April 2012 (04-12) TAS 103 Method 1 Option D 04/18/2016 04/25/2016 O6/08/2016 FL # Model, Number or Name Description 10450.1 Tarco Roof Underlayments Roof underlayments for use in prepared roof assemblies Limits of Use Installation Instructions Approved for use in HVHZ: No FL10450 R8 II 2016 04 FINAL ER TARCO UNDERLAYMENT Approved for use outside HVHZ: Yes RB.odf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-217.5 Created by Independent Third Party: Yes Other: 1.) The design pressure herein pertains to Evaluation Reports one particular bonded underlayment application for FL10450 R8 AE 2016 04 FINAL ER TARCO UNDERLAYMEN use beneath adhesive -set tile systems. Refer to ER RB.odf Section 5.6.2 for details, and other bonded Created by Independent Third Party: Yes underlayment systems. 2.) Refer to ER Section 5 for Limits of Use. Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refun Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records reques electronic mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.13E Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department w address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public n not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To dt are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: 0 WR 2M M Credit Card Safe A AN in, '4 MW m1f. o W dump""17i http://www.floridabuilding. org/t)r/pr_app_dtl. aspx?param=vGEVXQwtDqu... 5/ 18/2017 EVALUATION REPORT Tarco Roofing One Information Way, Suite 225 Little Rock, AR 72202 EXTERIOR RESEARCH & DESIGN, U.C. Certificate of Authorization N9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 10880.07.08-118 FL10450-R8 Date of Issuance: 07/11/2008 Revision 8: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Tarco Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida OCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, RE on 04/18/2016. This does not serve as an electmniwlN signed document. Signed, sealed hardcapho have beentrammitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity J ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. SI 20KC111JEMaw \ TRINITY J ERD I ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Tarco, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1504.3.1 Wind Uplift FM 4474 2004 1507.2.3, 1507.3.3, 1507.5.3, Physical Properties ASTM D226 2006 1507.7.3, 1507.8.3, 1507.9.3 1507.2.3, 1507.2.8, 1507.4.5.1, Physical Properties ASTM D4869 2005 1507.4.5.2, 1507.5.3, 1507.5.3.2, 1507.7.3, 1507.7.3.2, 1507.8.3, 1507.8.3.2, 1507.9.3, 1507.9.3.2 1507.2.4, 1507.2.9.2, 1507.5.3, Physical Properties ASTM D1970 2009 1507.7.3 1507.2.9.2 Physical Properties ASTM D3909 1997 1507.2.9.2, 1507.3.3 Physical Properties ASTM D6380 2003 1507.3.3 Installation Practice FRSA/TRI April 2012 (04-12) 2012 1507.12.2 Physical Properties ASTM D6164 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Enti Examination Reference Date ERD (TST6049) ASTM D6164 T6470.08.07-R1 08/30/2007 ERD (TST6049) FM 4474 T6460.06.07-R1 10/09/2007 ERD (TST6049) ASTM D1970 T30160.08.09 08/14/2009 ERD (TST6049) TAS 103 T33190.08.10 08/06/2010 ERD (TST6049) ASTM D1970 T32530.08.10 08/17/2010 ERD (TST6049) FM 4474 T37610.07.11 06/29/2011 ERD (TST6049) ASTM D3909 T40780.04.12 04/06/2012 ERD (TST6049) ASTM D6380. T40790.04.12 04/06/2012 ERD (TST6049) TAS 103 T35410.04.12 04/18/2012 ERD (TST6049) ASTM D1970 T45250.04.13-R2 04/23/2013 ERD (TST6049) Physical Properties T43930.09.13-R2 09/11/2013 ERD (TST6049) Physical Properties TAR-SC9480.15 07/02/2015 ERD (TST6049) Wind - FM4470/4474 TAR-SC5670.14 12/03/2015 ERD (TST6049) Wind - FM4470/4474 TAR-SC8020.14 12/03/2015 PRI (TST5878) ASTM D1970 BRY-018-02-01 08/11/2003 PRI (TSTS878) ASTM D1970 BRY-017-02-01 08/11/2003 PRI(TSTS878) ASTM D226 TOT-014-02-02 05/18/2004 PRI (TST5878) ASTM D226 TOT-015-02-02 05/24/2004 PRI(TSTS878) ASTM D6380 TOT-029-02-01 07/05/2005 PRI (TST5878) ASTM D4869 TOT-009-02-01 09/14/2004 PRI (TST5878) ASTM D4869 TOT-009-02-02 09/14/2004 PRI (TST5878) ASTM D226 TOT-041-02-01 05/24/2006 Miami -Dade (CER3592) FBC HVHZ Certification 12-0420.02 10/03/2013 Tarco Roofing Adhesive compound Affidavit 12/15/2015 UL, LLC. (QUA9625) Quality Assurance Service Confirmation Exp. 30/13/2017 Exterior Research and Design, U.C. Evaluation Report 10880.07.08-R8 CertWcate oJauthorizatlon x9503 FL10450-RB 16 F LE COPYRevision 8: 04/18/24/18/2016 Page 2 of 10 �l I RINITY ERD 4. PRODUCT DESCRIPTION: 4.1 Self -Adhering Underlavments: LeakBarrier Fast90 Self -adhering Tile Underlayment is an asphalt -saturated organic felt coated on both sides with asphalt and surfaced on the top side with mineral granules and on the underside with a self - adhering compound and release film. LeakBarrier MS300 Ice and Water Armor is a self -adhering, glass mat reinforced, mineral surfaced, SBS modified roof underlayment. LeakBarrier PS200ar Ice and Water Armor is a self -adhering, glass mat reinforced, fabric surfaced, SBS modified roof underlayment. LeakBarrier PS200Mu Ice and Water Armor is a self -adhering, glass mat reinforced, smooth poly film surfaced, SBS modified roof underlayment. LeakBarrier NR500w is a self -adhering, plastic film surfaced, modified underlayment. LeakBarrier SS400 Ice and Water Armor is a self -adhering, fiberglass reinforced, smooth surfaced modified underlayment. 4.2 Mechanically Fastened Underlavments: Tarco 15 is an ASTM D226 Type I, 15 lb asphalt -saturated organic felt Tarco 30 is an ASTM D226 Type II, 30 lb asphalt -saturated organic felt Tarco NO 30 is an ASTM D4869 Type II asphalt -saturated organic felt LeakBarrier EasyLay is an asphalt -coated polyester fabric roof underlayment. 4.3 Mechanically Fastened and/or Bonded Underlavments: Fiberglass Mineral Surfaced Roll Roofing is an ASTM D3909, glass -fiber -reinforced, asphalt -coated, granule surfaced underlayment used as a valley liner. ASTM Organic Mineral Surface Tile Underlayment is an ASTM D6380, Class M asphalt -saturated organic roll roofing sheet. LeakBarrier EasyMopm SBS is a polyester reinforced, SBS modified bitumen roofing underlayment. 4.4 Mechanically Fastened Base Sheets: LeakBarrier EasyLay UDL 15 consists of a woven -polymeric scrim with a textured fabric on the top surface. Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. LeakBarrier EasyLay UDL Basic consists of a woven -polymeric scrim with a textured fabric on the top surface. Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. LeakBarrier EasyLay UDL 50 consists of a woven -polymeric scrim with a non -woven fabric on the top surface and a rubberized polymeric coating on the back surface. Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LI.C. t-�� rryy Evaluation Report 10880.07.08-R8 [e mte oJauthoAzallon #9503 I L I E� �� FL303 of 10 Revision 8: 04/18/2016 Page 3 of 10 Ili ,\J TRINITY ERD 5.4 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop Tarco underlayments are follows: TABLE 1: ROOF COVER OPTIONS Asphalt wood Shakes Underlayment Nail -On Tile Foam -On Tile Metal Slate Shingles & Shingles LeakBarrier Fast90 Yes Yes Yes No Yes Yes See 5.5.2 LeakBarrier M5300 Yes No No No Yes Yes LeakBarrier PS200"r Yes Yes Yes yes Yes Yes See 5.5.2 LeakBarrier P5200` Yes No No Yes Yes Yes Yes LeakBarrier NR500ur Yes No No (No copper or Yes Yes zinc) LeakBarrier SS400 Yes No No No Yes Yes Yes Yes LeakBarrier EasyLay Yes (as base sheet in (as base sheet in Yes Yes Yes multi -ply system) multi -ply system) LeakBarrier EasyLay Yes Yes UDL 15, UDL Basic or Yes (as base sheet in (as base sheet in Yes Yes Yes UDL 50 (See FL16884) multi -ply system) multi-plysystem) L1 (See F6884) (See FL16884) (See FL16884) Tarco 15 Yes No No Yes Yes No Yes Yes Tarco 30 Yes (as base sheet In (as base sheet in Yes Yes Yes multi -ply system) multi-plysystem) Tarco NO 30 Yes No No Yes Yes Yes (double layer) (double layer) (double layer) (double layer) Fiberglass Mineral Yes Surfaced Roll Roofing Valley Bner per No No No No No 1507.2.9.2(2) ASTM Organic Mineral Surface Tile Yes Yes Yes No Yes Yes Underlayment see 5.5.2 LeakBarrier EasyMop Yes SBS yes Yes See 5.5.2 No Yes Yes 5.5.1 Tarco 15, Tarco 30, Tarco NO 30 and Easy Lay may be used as a mechanically attached base layer followed by a LeakBarrier self -adhering top layer or asphalt -applied ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS with allowable roof covers noted above for the respective top layer underlayments. 5.5.2 "Foam -On Tile" is limited to use of 3M 2-Component Foam Roof Tile Adhesive AH-160 (FL6332) applications unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. a WN WqA Td Exterior Research and Design, LLC. Evaluation Report 10880.07.08-R8 certificate of Authorization #9503 FL10450-R8 Revision 8: 04/18/2016 Page 4 of 10 4TRINITY ERD 5.6 Allowable Substrates: 5.6.1 LeakBarrier self -adhering direct -bond to deck: ➢ New untreated plywood (unprimed or primed with ASTM D41 primer); ➢ Existing plywood (unprimed or primed with ASTM D41 primer); ➢ New or existing OSB (unprimed or primed with ASTM D41 primer); ➢ Structural concrete (unprimed or primed with ASTM D41 primer). Note: Tarco does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of LeakBarrier membranes. ASTM Organic Mineral Surface Tile Underlavment or LeakBarrier EasvMoD SBS Direct -Bond to Deck D ASTM D41 primed structural concrete. Note: Refer to 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the overlying roof cover is foam -on tile roofing. 5.6.2 Bond to Mechanically Attached Base Sheet: LeakBarrier self -adhered to: D ASTM D226, Type I or II felt; ➢ ASTM D4869 felt; ➢ LeakBarrier EasyLay, LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50. ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS in hot asphalt to: D ASTM D226, Type I or II felt; ➢ ASTM D4601, Type 11 base sheet. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12). 5.6.3 LeakBarrier Self -Adhering Bond to Other Substrate Types: ➢ ASTM D41 primed metal (flashing metal, valley metal, etc.) 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 5.6.4.1 Maximum Design Pressure=-75.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ Primer: (Optional) ASTM D41 Base Ply: (Optional) LeakBarrier P5200Mu, self -adhered. Underlayment: LeakBarrier PS200er, self -adhered. 5.6.4.2 Maximum Design Pressure=-120.0 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ Primer: (Optional) ASTM D41 Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200Mu or LeakBarrier EasyBase, rolled into place to create continuous bond Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered Underlayment: LeakBarrier PS200u', self -adhered. P Exterior Research and Design, U.C. Evaluation Report 10880.07.08-R8 Certificate ofAuthodro0on X9503 FL10450-R8 Revision 8: 04/18/2016 Page 5 of 10 `�J TRINITY ERD 5.6.4.3 Maximum Design Pressure = -217.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Base Ply: (Optional) LeakBarrier P5200Mu, self -adhered Underlayment: LeakBarrier PS200HT, self -adhered. 5.6.4.4 All other direct -deck, adhered Tarco underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. 5.6.4.5 Maximum Design Pressure=-45.0 osf• Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide rolls); See FBC FL36884. Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c. at the 4-inch wide side laps and 8" o.c. at three (3) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier P5200Mu, self -adhered Underlayment: LeakBarrier PS2001T, self -adhered. 5.6.4.6 Maximum Design Pressure=-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 7" o.c. at the 4-inch wide side laps and 7" o.c. at three (3) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier P5200Mo, self -adhered Underlayment: LeakBarrier 1)52001i self -adhered. 5.6.4.7 Maximum Design Pressure=-60.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide rolls); See FBC FL16884. Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c. at the 4-inch wide side laps and 6" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier P5200Mo, self -adhered Underlayment: LeakBarrier PS200nr, self -adhered. 5.6.4.8 Maximum Design Pressure=-82.5 psf Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: LeakBarrier EasyLay Fasteners: Simplex MAXX Cap Fasteners Spacing: 8" o.c. at the 4-inch wide side laps and 8" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS2001r, self -adhered. 5.6.4.9 Maximum Design Pressure=-120.0 osf Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 4" o.c. at the 4-inch wide side laps and 4" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier P5200mu, self -adhered Underlayment: LeakBarrier PS200HT, self -adhered. Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-118 Certificate ofAutho4zation a9503 FL10450-118 Revision 8: 04/18/2016 Page 6 of 10 v I MNITY j ERD l 5.6.4.10 For mechanically attached base sheet in a multi -ply system, the maximum design pressure for the selected assembly shall, at a minimum, meet or exceed the Zone 1 design pressure determined in accordance with FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD3. Assemblies above marked with an asterisk' carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 5.7 Exposure Limitations: LeakBarrier EasyLay, FAST 90, ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier EasyMop SBS shall not be left exposed for longer than 180-days after installation. LeakBarrier PS200'T shall not be left exposed for longerthan 120-days after installation. LeakBarrier MS300, NR500RTI P5200Mv or SS400 shall not be left exposed for longer than 30-days after installation Tarco 15, Tarco 30 and Tarco NO 30 shall be covered as soon as possible after installation; exposure for more than 24 hours after installation could adversely affect performance. 6. INSTALLATION: 6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and primed the substrate (if applicable). 6.3 LeakBarrier®Fast90®Self-Adhering Tile Underlavment: 6.3.1 EasyLay shall be installed in compliance with the requirements for 90# felt underlayment (except the product is self -adhered) in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile Applications: Cut the Fast90 roll into 12'to 16' sections for workability and allow to relax prior to application. Chalk a plumb line 36" from all outside perimeters; then chalk plumb lines 32" apart, upslope to the ridge line. Membrane Application: ➢ Place a full width piece of Fast90 on the prepared substrate, parallel to the eave edge of the roof, with the selvedge edge positioned upslope and in -line with the 1n chalk line. ➢ Fold back half the sheet and remove the exposed release film, taking care not to displace the membrane ➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles and ridges, and repeat for the other half of the sheet. ➢ Remove selvage release film, if present, and install capped or tin tagged nails 6" o.c. in the center of the selvedge edge. ➢ Install the subsequent sheets in the same manner, with upslope selvedge edges in -line with chalk lines, with 4" side laps and 8" end laps. ➢ Seal all 8" end laps 1/16" thick application of asphalt plastic cement and stagger all end laps minimum 36". ➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave / rake areas to ensure a complete bond. 6.3.4 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Wait a minimum of 24 hours prior to loading roof tiles. Exterior Research and Design, I.I.C. pp�� ���777 ��--i Copyvaluation Report 10880.07.08-RB [ert/Jlmte oJAutharliodon #95a3 FL/18/2016 Revision 8:80.07. 2016 Page 7 of 10 TRINITY ERD ( All tiles shall be staged four tiles perpendicular to slope, six tiles on top, parallel to slope; not to exceed 10 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal batten. 6.4 LeakBarrier® MS300. PS200K. PS200Mu. NR500"T or SS400 Ice and Water Armor: 6.4.1 MS 300, PS200HT, PS200mu, NR500"T or SS400 shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 Non -Tile Applications: Cut MS 300, PS200 HT PS200Mu, NR500"T or SS400 to manageable sections and allow to relax prior to application. Membrane Application: ➢ Place a full width piece on the prepared substrate, aligned parallel to the eave edge and extend approximately 3/8" over the eave and rake with the selvedge edge positioned upslope. ➢ Fold back the upslope half of the sheet and remove the exposed release film, taking care not to displace the membrane ➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles and ridges ➢ Apply a 1/16" thick layer of asphalt plastic cement over the eave and rake metal, extending 2" to 3" onto the deck surface. ➢ Fold back the downslope half of the sheet, remove the release film and roll the membrane onto the substrate from the centerline out. ➢ Seal all 6" end laps with a 1/16" thick application of asphalt plastic cement and stagger all end laps minimum 36". ➢ Remove selvage release film, if present, and install second and subsequent courses in a similar manner. ➢ Install capped or tin -tagged nails 6" o.c. along the centerline of the laps. ➢ At all T-joints, where an end -lap and the next overlapping course intersect, apply a bead of roofing laps cement before the overlapping course is laid. ➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave / rake areas to ensure a complete bond. 6.4.3 Tile Applications (PS2 00"T only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Wait a minimum of 24 hours prior to loading roof tiles. All tiles shall be staged four tiles perpendicular to slope, six tiles on top, parallel to slope; not to exceed 10 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal batten. Exterior Research and Design, LLC.122-5 Rl`��'OOPY L Evaluation Report 10880.07.08-118 Certificate of Authorization #9503 FL10450-RS Revision 8: 04/18/2016 Page 8 of 10 TRINITY ERD 6.4.4 Multi -Ply Underlayment Systems: LeakBarrier® SS400 Ice and Water Armor followed by LeakBarrier® SS400 Ice and Water Armor (direct -to - deck per 5.6.1 or over mechanically attached base sheet per 5.6.2) is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a multi -ply underlayment system is desired. 6.5 Tarco 15 and 30: 6.5.1 Tarco 15 and 30 shall be installed in compliance with the requirements for ASTM D226, Type I and II underlayments, respectively, in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.5.2 Non -Tile Applications: Reference is made to the current edition of the NRCA Steep -slope Roofing Manual. 6.5.3 Tile Applications, base laver in multi -ply system (Tarco 30 only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. 6.6 Tarco NO 30: 6.6.1 Tarco NO 30 shall be installed in compliance with the requirements for ASTM D4869, Type II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed; 1507.4.5.2 (1), 1507.5.3.2 (1), 1507.7.3.2 (1), 1507.8.3.2 (1) or 1507.9.3.2 (1). 6.7 LeakBarrier EasyLay: 6.7.1 EasyLay shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.7.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.7.3 Non -Tile Applications: Place a full width section of EasyLay, parallel to the eave edge of the roof and unroll 2 to 3 feet with the lay lines facing up, and position to the edge of the eave and rake. Install a few fasteners at the top, near the rake, and roll out the sheet to a manageable length. Pull, straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the eave edge. Fasten with 3/8" headed roofing nails or 1" capped (plastic or metal) nails, driven by hand or pneumatically, spaced 6" o.c. at all laps in the center of the seam area, and two staggered rows fastened 12" o.c. in the field of the sheet. Install nails such that the head of the nail is flush with the surface, without cutting into the surface. Fasten from the top to avoid walking or kneeling on unsecured sheet. Continue to the end of the substrate and fasten down. Align the next roll over the preceding sheet so as to form a minimum 4", water -shedding lap, and install per instructions above. Apply subsequent sheets in the same manner, with minimum 4" water -shedding laps and minimum 8" end -laps, which are staggered minimum 36" fro the preceding course. For double layer applications, follow the instructions noted above, but using a minimum 19", water - shedding side lap. Allow for minimum 6" up the vertical transitions and minimum 6" over hips and ridges. At valleys, first install a vertical length of EasyLay down the center of the valley, then start at the law point and work to the high point, rolling the membrane from the center outward in each direction, ensuring no wrinkles or tears. Covered with valley -metal or other valley lining material in accordance with NRCA recommendations. Apply a thin coat of asphalt plastic cement to waterproof areas where any cuts or tears have occurred. Seams or joints that require adhesive or sealant can be treated with high quality plastic cement (asbestos free). Exterior Research and Design, U c. FILE P Evaluation Report 30880.07.08-R8 Certificate ofAuthori:otion C9503 FL10450-R8 Revision 8: 04/18/2016 Page 9 of 10 ,l TRINITY ERD 6.7.4 Tile Applications, base laver in multi -ply system: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. 6.8 ASTM Organic Mineral Surface Tile Underlavment: 6.8.1 Shall be installed in compliance with the requirements for ASTM D6380, Class M sheets in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.8.2 Non -Tile Applications: Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings. 6.8.3 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 6.9 LeakBarrieeTM EasyMop SBS: 6.9.1 Shall be installed in compliance with current Tarco published installation requirements, subject to the limitations herein. 6.9.2 Non -Tile Applications: For mechanically attached applications: Secure LeakBarrier EasyMop SBS using 3/8-inch headed roofing nails or 1-inch diameter cap -nails spaced 9-inch o.c. within the 4-inch wide side laps and 12-inch o.c. in two (2) equally spaced, staggered center rows in the center of the sheet. End -laps shall be minimum 6-inch wide, and offset end -laps minimum 3-feet from course to course. Seal end laps in accordance with Tarco requirements. For bonded applications: Fully adhere LeakBarrier EasyMop SBS in hot -asphalt to the substrates noted in Section 5.5. Side laps shall be minimum 4-inch and end -laps minimum 6-inch wide, and offset end -laps minimum 3-feet from course to course. Side and end -laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. Consult Tarco instructions regarding back -nailing requirements. 6.9.3 Tile Applications: Refer to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted CIA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements 9. QUALITYASSURANCE ENTITY: UL, LLC. — QUA9625; (847) 664-3281 - END OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report 10880.07.08-118 certificate ofAuthorieation 99503 FL104S0-RB Revision 8: 04/18/2016 Page 10 of 10