HomeMy WebLinkAboutPRODUCT APPROVALt Rorida Building Code Online Page 1 of 2
0
r F�
LE
Business e tnal Re.901.0tiona 1
BCIS Home Log In User Registration Hot Topics Submit SurcbaMe Stats & Facts Publications F8C Staff BCIS Site Map sinks search
G Product Approval
dQ'pr
USER: P�eue user
r Product Aonrovdl Menu > Prool act or Application Search > Application List > Appliesition Detail SGANNEb
BY
FL x FL10674-R12 St. Lucie C;rnlntl
Application Type Revision
Code Version 2014
Application Status Approved
"Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Emall
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
I=1 THESE PLIANS AND ALL PROPOSED WORK
ARE SUNECT TO ANY CORRECT IONS
Owens Corning One Owens Corning Parkway fsi:GUII?EU BY FIELD INSPECTORS THAT
Toledo, OH 43659 Py°AY BE NECESSARY IN ORDER? TO
(740) 404-7829 (s p� _
greg.keeler@owenscorning.comCGi%riPLY WITH H ALL APPLICNSLE GODEU.
Greg Keeler
greg.keeler@owenscorning.com
Mel Sancrant
1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscomig.com
Roofing
Asphalt Shingles
/ ST, LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COMPLIAN
REVIEWED BY
DATE
PLANS AND E IT
MUST BE KEPT O JOB OR
NO INSPECTION WILL BE MADE
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Robert ).M. Nieminen CONG90 PAMNIRS ORATIACHMS
PE-59166 Apt TNT ROPON6191L" OF THE
UL LLC et►
08/20/2017 ouuef0()t/
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
FL10674 R12 COI 2016 01 COI Niemirlen.,df
Referenced Standard and Year (of Standard) Standard Vear
ASTM 03161 2009
ASTM D3462 2009
ASTM 07158 2008
Equivalence of Product Standards
Certified By
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 Vp/d2... 1/19/2017
Florida Building Code Online
Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
I
Method 1 Option D
04/18/2016
04/19/2016
04/20/2016
06/08/2016
FL *
Model, Number or Name
Description
10674.1
Owens Corning Asphalt Roofing
3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge
Shingles and Starters
shingles
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10674 R12 11 2016 04 FINAL ER OC A PHA T
SHINGLES FL30674-R32 odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert J. M. Nieminen PE - S9166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section S.
Evaluation Reports
FL10674 R12 AE 2016 04 FINAL ER OC ASPHALT
SHINGLES FL10674-R12 odf
Created by Independent Third Party: Yes
Beck Neat
Contact 3:: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an WEED employe, Cnnvdnht 2007-2013 State of Florida. :: Prlvaro Statement :: Accessibility Statement:: Refund Statement
Under Florida law, email addresses arc public records. If you do not want your e-mail address released In response to a public -records request, do not send
electronic mail to this entity. Instead, compact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address it
they have one. The smalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under
the star ass, F.S., please click here-.
traduce Approval Accepts:
W Q0 Kled
Credit Card
Safe
A1d
ii
http://www. floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEV XQwtDgtBNbEY5 V °/d2... 1 /19/2017
TRINITY ERD
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate ofAuthorizotlon #9503
353 CHRISTIAN STREET. UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report 037940.02.12-R7
F1.10674-R12,I
Date of Issuance:02/06/2012
Revision 7: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity(ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert I.M. Nieminen, P.E.
Florida Registration No. 59166 Florida OCA ANE1983
CERTIFICATION OF INDEPENDENCE:
W FIT -
IN 01
The fadlmde seal appearing was autharoad by Robed Nieminen,
P.E. an W/1g/2a16. This does not serve as an electronically signed
document signed, sealed Iurdmpies love be..tansmitted to the
Pmdud Approval Adm lnhtrator and to the named die is
1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity) ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen,-P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/wasused for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ER®
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM 03462
2009
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM 03161
2009
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2008
3. REFERENCES:
Entity
Examination
Reference
Date
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol. 3
02/15/2007
UL LLC (CER9626)
Physicals & Wind Resistance
20120516-R2453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/O1/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER1592)
FBC HVHZ Compliance
Various NOAs
Various
UL LLC (QUA9625)
Quality Control
Service Confirmation, R2453
Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles: LmE`C .
4.1.1 Classic and Supremee are fiberglass reinforced, 3-tab asphalt roof shinFes
PY
4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 Devonshire'" are fiberglass reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration', Tru Definition Duration', Duration Premium Cool, Tru Definition Duration Designer Color
Collection, TruDefinition0akridge, Oakridge* and WeatherGuard" HP are fiberglass reinforced, laminated
asphalt roof shingles. miiiaiix5ax
4.2 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidge" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityjERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7
Cenircote of Authorization 09903 F1.30674-1112
Revision 7: 04/18/2016
Page 2 of 8
6.
TRINITY ERD
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R9O5.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Va,d = 150 mph IV, = 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified
in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are
acceptable for use in all wind zones up to Va,d = 150 mph (Vei, =194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category 8 or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations. Contact
the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G2O.3, per FBC Sections 1507.2.3, 1507.2.4 or R9O5.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Berkshire shingles require minimum five (5) nails per shingle.
➢ WeatherGuarda HP shingles require minimum six (6) nails per shingle.
➢ Devonshire" shingles require minimum six (6) nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing— Starter Strip Shingle and Starter Strip Plus:
Felt underlayment Deck
8ef-adheted
weatherLocke
underlaymenl
Dtip_ Dripedge
edge
Nailslocared
2" 3' from eave
Install rnsr 8eR-saafin9adhesive
StattwstrfCC posiNorrM abng oneshingle with
e'ramoved srader6wip shingle overhangs eaves and rakes!V4i
Exterior Research and Design, LLC.
CertiJimte of Authorization 99503 I'm Lit CUPY
Shccanuee
WeaNeM1aN&
IIEPIIdyTLln
eava
can
Ploa avvhanea ervea and rakes VP-01V
Evaluation Report 037940.02.12-R7
FL10674-R12
Revision 7: 04/18/2016
Page 3 of 8
6.2.6 Minimum Nailing —Classic°&Supreme:
Nons d Mansard or Area per.
Wind Are.. Nigh Wind dsvanes y
Area per. vi.nto. aarmales Ar... rienro. luerta.
VE.00.ur•
Ex,.W.Mn
6.2.7 Minimum Nailing — Berkshire®:
�itol.rlt.�xfitadldatltca try
TRINITY ERD
N.nsual M.mod or Are. pare
Wind Areas Nigh Wind dervsnss y
Area Para vi.ntas normal.. Are.. vienroe f..rtea
6 Sli' Exposure
Expo.leidn
Sea6rasdp
is Ors do ulhMr
Sed•ntwip
to Iur do ulhdor
BW' xis AW. I 8W"
1"
6-Nail Fastening Pattern
—fer -• e•�e.�
1Yf I B Yf I g Yf I g Vf'
I
2' Asphae roolin9cem=.m
G'nanto da txhode esh4o
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design, LLC. Evaluation Report O37940.02.12-R7
CertlflCate ofAuthorhation 099g3 FL10674-1112
Revision 7: 04/18/2016
Page 4 of
6.2.8 Minimum Nailing —Devonshire":
'= 7" 1 8" 1 8" 8- 7-1 1"
- rirp.
5-5/8' exposure Sealant location
Eaposicidn de 5 -5/8 pull; Ulairacidn del sellador
Standard 6-Nail Fastening Pattern
\\
TRINITY ERD
Nails
n•.
�s•
Ten l" Spots of Asphah Roof Cement
Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, TruDefinition" Duration, Duration® Premium Cool & TruDefinitione Duration
Designer Color Collection:
4-Nall Fastening Pattern
aweXailDhNrvipmaMM
XVS TYN+a1
r ,r I u•
s+n^
Standard Fastening Pattern
,a•
6-Nell Fastening Portent
SuraNaiRhNnLq ],N MM
M11.lyplcl
r +r r
6-148D
.... _ __
pea Greater Than 21:12
r��x.w e".""p •••..+ac
X.o. nR�,ar
RCOa�O Gn•n,
Mansard or Steep Slope Fastening Pattern
Exterior Research and Design, I.I.C.
certificate ofAuchorieallon 09503
6-Nail Fastening Pattern
Evaluation Report 037940.02.12-R7
FL10674-R12
Revision 7: 04/18/2016
Page 5 of 8
6.2.1 Minimum Nailing—TruDefinition Oakridge®, Oakridge°:
4 Nal Perim
Esquema wn 4 claws
r r
I<— tr —►I k— tr �{
a pm'6osure Na Rs 561a"Fxposure
Espoaidm de 56/6pulg. claws Exposicidn de 6619pWg
Standard Fastening Pattern
ln>
Iav I - Span
;TRINITY ERD
6 Nail Pattern
Esquema con 6 claws
t• r
IF rz —►� k— tr —►{
66iB"FxpowNails re Cfavm 66le"Ezposum
Exposiddn de 5619pW9. Fposidbn de 66/8 pulg.
sw•xnwuumxs •�••�sm
r x.v.iYOirn
Mansard or Steep Slope Fastening Pattern
6.2.1, Minimum Nailing — WeatherGuard® HP:
6-Nall Fastening Pattern
t• / t `Lll2ab
l.— 2• t �I
::a+ :L•::•a+
Cana en rAllow + fFdG
Lim
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-117
Certificate clAutharientian 99503 FL10574-1112
Revision 7: 04/18/2016
Page 6 of 8
, TRINITY ERD
6.3 Hit) & Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard HP Hip and Ridge Shingles and
Pro Edge Hip & Ridge Shingles shall comply with the manufacturers current published instructions, using four
(4) nails per shingle. Installation of DuraRidge'" Hip & Ridge Shingles shall comply with the manufacturer's
current published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing for wind
warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing— Berkshire® Hip & Ridge and High Ridge:
FIg.1
K._ PmalNgwna
PCMb A
Nalls A
\\ F4
A
i
q I
A 1 I 1 I I
y i r
Fig.2
i.Pv..
swevl
w
Xtl13 X313
f 1
P iaPL
6inYe1
R e
1' 1
11
@I I
sl
I
I
-- II
6.3.4 Minimum Nailing— WeatherGuard® HP Hip and Ridge:
F
I' EapowR N
Exterior Research and Design, LLC.
Certificate of Authorization 49503
Fig. C Hip & Ridge Shingle Fastening
TOPXkw
Na16 Xa15
t..
17.
7. 1..
1 to
s- Lapawle
Evaluation Report 037940.02.12-R7
FL10674-R32
Revision 7: 04/18/2016
Page 7 of 8
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Prevailing
Wind Direction Sadism Strip
6'Exposure
i 7'h'
Exposed
an with
t
I' TRINITY ERD
Standard ^tP�
Fastening
Pattern
r� I•� �I•I I.r
72• 1 ' Sealant
1 7•II'' 6'Exposurs
1 11 L-12'--`
6.3.6 Minimum Nailing— DuraRidge1e Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
TOP View
vue m q n
Vhra eupetlor
c
c
V
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named CIA entity for information on which plants produce products covered by Florida Rule 9N-3 CIA
requirements.
10. QUALITY ASSURANCE ENTITY:
END OF EVALUATION REPORT - L 1
UL LLC— QUA9625 ; (414) 248-6409; karen.buchmann@ul.comE`
Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R7
[ertircote of Authorization a9503 F1.70674-1112
Revision 7: 04/18/2016
Page 8 of 8
Florida Building Code On'=--^ Page 1 of 2
FILE
BCIS Home I Log In i User Registration Hot Topla I Submit Surcharge i Stats & Facts i Publications I FSC Staff i BCIS Site Map I L
(i0rl0d
Y -i Product Approval
F� USER: Public User
' SCHNNE
m na
Product Aooroval Menu > Product or Aoolication Search > Application List > Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the
Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL10450-RB
Revision
2014
Approved
0
U
BY
St. Lucie Cnlinfi
ARE SUBJECT TO ANY CORREGMIS
REQUIRED BYFIrLD INSPECTORS THAT
NlXf BE NECESSARY IN ORDEIR TO
COIMPLY WITH ALL APPLIO1.
M • E LGGO G.
One Information Way
Suite 225
Little Rock, AR 72202
(254)913-7750
smohseen@tarcoroofing.com
Shalk Mohseen
smohseen@ta rcoroofi ng.com
Sheik Mohseen
2403 Taylors Valley Road
Belton, TX 76513
(254) 913-7750
smohseen@tarcoroofing.com
Shaik Mohseen
2403 Taylors Valley Road
Belton, TX 78717
(254)939-3775 Ext 210
smohseen@tarcoroofing.com
Roofing
Undedayments
Evaluation Report from a Florida Registered Architect or a Licen
Professional Engineer
❑ Evaluation Report - Hardcopy Received
Robert Nieminen CONCEALED PASTENERS ORATTACHMENts
PE-59166 ARE THE RESPONSIBILITY OF THE
UL LLC
10/13/2017 CON RAMROFMORD
John W. Knezevich, PE
® Validation Checklist - Hardcopy Received
FL10450 R8 COT 2016 01 COI Nieminen.udf
Standard
ASTM D1970
ASTM D226
ASTM D3909
ASTM D4869
ASTM D6164
http://www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDqu... 5/ 18/2017
Florida Building Code On 7, -
Page 2 of 2
ASTM D6380
FM 4474
FRSA/TRI April 2012 (04-12)
TAS 103
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted
04/18/2016
Date Validated
Date Pending FBC Approval
04/25/2016
Date Approved
06/08/2016
FL It Model, Number or Name Description
10450.1 Tarco Roof Underlayments Roof underlayments for use in prepared roof assemblies
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10450 R8 II 2016 04 FINAL ER TARCO UNDERLAYMENT
Approved for use outside HVHZ: Yes
R8.odf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-217.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure herein pertains to
Evaluation Reports
one particular bonded underlayment application for
FL10450 RS AE 2016 04 FINAL ER TARCO UNDERLAYMEN
use beneath adhesive -set tile systems. Refer to ER
R8.odf
Section 5.6.2 for details, and other bonded
Created by Independent Third Party: Yes
underlayment systems. 2.) Refer to ER Section 5 for
Limits of Use.
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refun
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records reques
electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.135
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department x
address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public r.
not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To dE
are a licensee under Chapter 455, F.S., please click here .
Product Approval Accepts
MI is F--il M
Credit Card
Safe
2 Is." IWAY
�
http: //www. flori dabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDqu... 5 / 18/2017
�J I KINI-IY ERD
EVALUATION REPORT
Tarco Roofing
One Information Way, Suite 225
Little Rock, AR 72202
EXTERIOR RESEARCH & DESIGN, U.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
ration Report 10880.07.08-R8
FL104S0-RS
Date of Issuance: 07/11/2008
Revision 8: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Tarco Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 10.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The facsimile seal aimcaring was authormed by Robert Nleminen,
P.E. on 04/18/2016. This does net serve as an electronically signed
document. Signed, sealed hamcoPies have been transmitted to the
Product Appro✓al Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinity) ERD does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or
distributing products it evaluates.
2. Trinity l ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest In any other entity involved in the approval process of the
--- ---- -product. -
5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Tarco, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Proper Standard Year
1504.3.1 Wind Uplift FM 4474 2004
1507.2.3, 1507.3.3, 1507.5.3, Physical Properties ASTM D226 2006
1507.7.3, 1507.8.3, 1507.9.3
1507.2.3, 1507.2.8, 1507.4.5.1, Physical Properties ASTM D4869 2005
1507.4.5.2, 1507.5.3, 1507.5.3.2,
1S07.7.3, 1507.7.3.2, 1507.8.3,
1507.8.3.2, 1507.9.3, 1507.9.3.2
1507.2.4, 1507.2.9.2, 1507.5.3, Physical Properties ASTM D1970 2009
1507.7.3
1507.2.9.2 Physical Properties ASTM D3909 1997
1507.2.9.2, 1507.3.3 Physical Properties ASTM D6380 2003
1507.3.3 Installation Practice FRSA/TRI April 2012 (04-12) 2012
1507.11.2 Physical Properties ASTM D6164 2005
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
KnUnt Examination Reference Date
ERD (TST6049) ASTM D6164 T6470.08.07-111 08/30/2007
ERD (TST6049) FM 4474 T6460.06.07-RI 10/09/2007
ERD (TST6049) ASTM D1970 T30160.08.09 08/14/2009
ERD (TST6049) TAS 103 T33190.08.10 08/06/2010
ERD (TST6049) ASTM D1970 T32530.08.10 08/17/2010
ERD (TST6049) FM 4474 T37610.07.11 06/29/2011
ERD (TST6049) ASTM D3909 T40780.04.12 04/06/2012
ERD (TST6049) ASTM D6380 T40790.04.12 04/06/2012
ERD (TST6049) TAS 103 T35410.04.12 04/18/2012
ERD (TST6049) ASTM D1970 T45250.04.13-R2 04/23/2013
ERD (TST6049) Physical Properties T43930.09.13-R2 09/11/2013
ERD (TST6049) Physical Properties TAR-SC9480.15 07/02/2015
ERD (TST6049) Wind - FM4470/4474 TAR-SC5670.14 12/03/2015
ERD (TST6049) Wind - FM4470/4474 TAR-SC8020.14 12/03/2015
PRI(TST5878) ASTM D1970 BRY-018-02-01 08/11/2003
PRI(TST5878) ASTM D1970 BRY-017-02-01 08/11/2003
PRI(TST5878) ASTM D226 TOT-014-02-02 05/18/2004
PRI(TST5878) ASTM D226 TOT-015-02-02 OS/24/2004
PRI(TST5878) ASTM D6380 TOT-029-02-01 07/05/2005
PRI(TST5878) ASTM D4869 TOT-009-02-01 09/14/2004
PRI(TST5878) ASTM D4869 TOT-009-02-02 09/14/2004
PRI(TST5878) ASTM D226 TOT-041-02-01 OS/24/2006
Miami -Dade (CER1592) FBC HVHZ Certification 12-0420.02 10/03/2013
Tarco Roofing Adhesive compound Affidavit 12/15/2015
UL, U.C. (QUA9625) Quality Assurance Service Confirmation Exp. 10/13/2017
Exterior Research and Design, U.C. Evaluation Report 10880.07.08-R8
CertiTcate o)AuNorizodon 49503 F1.20450-118
16
F LE � ;PYRevision 8: 0 ge 2 of 10 Page 2 of SO
\1 TRINITY I ERD
4. PRODUcr DESCRIPTION:
4.1 Self -Adhering Underlavments:
LeakBarrier Fast90 Self -adhering Tile Underlayment is an asphalt -saturated organic felt coated on both
sides with asphalt and surfaced on the top side with mineral granules and on the underside with a self -
adhering compound and release film.
L,cakB�Pricr MY) r a self -adhering, glass mat reinforced, mineral surfaced, SBS
modified roof underlayment.
LeakBarrier P5200"r Ice and Water Armor is a self -adhering, glass mat reinforced, fabric surfaced, SBS
modified roof underlayment.
LeakBarrier PS200mu Ice and Water Armor is a self -adhering, glass mat reinforced, smooth poly film
surfaced, SBS modified roof underlayment.
LeakBarrier NR500"T is a self -adhering, plastic film surfaced, modified underlayment.
LeakBarrier SS400 Ice and Water Armor is a self -adhering, fiberglass reinforced, smooth surfaced
modified underlayment.
4.2 Mechanically Fastened Underlavments:
Tarco 15 is an ASTM D226 Type I, 15 lb asphalt -saturated organic felt
Tarco 30 is an ASTM D226 Type II, 30 lb asphalt -saturated organic felt
Tarco NO 30 is an ASTM D4869 Type II asphalt -saturated organic felt
LeakBarrier EasyLay is an asphalt -coated polyester fabric roof underlayment.
4.3 Mechanically Fastened and/or Bonded Underlavments:
Fiberglass Mineral Surfaced Roll Roofing is an ASTM D3909, glass -fiber -reinforced, asphalt -coated,
granule surfaced underlayment used as a valley liner.
ASTM Organic Mineral Surface Tile Underlayment is an ASTM D6380, Class M asphalt -saturated organic
roll roofing sheet.
LeakBarrier EasyMopm SBS is a polyester reinforced, SBS modified bitumen roofing underlayment.
4.4 Mechanically Fastened Base Sheets:
LeakBarrier EasyLay UDL 15 consists of a woven -polymeric scrim with a textured fabric on the top
surface. Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See
FBC File No. FL16884 use as a stand-alone roof underlayment.
LeakBarrier EasyLay UDL Basic consists of a woven -polymeric scrim with a textured fabric on the top
surface. Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See
FBC File No. FL16884 use as a stand-alone roof underlayment.
LeakBarrier EasyLay UDL 50 consists of a woven -polymeric scrim with a non -woven fabric on the top
surface and a rubberized polymeric coating on the back surface. Within this Evaluation Report, it is used
as a base sheet in multi -ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof
underlayment.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, U.C.��'Evaluation Report 10880.07.08-R8
[ertiProte o)Arrthod:atlon #9503 L
t U F4/18/2-R8
Revision 8: 04/18/201fi
Page 3 of 10
5.4 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically
referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval
based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop Tarco underlayments are follows:
TABLE1: ;ROOF COVER OPTIONS _
Asphalt
Wood Shakes
Underlayment
Nail-On.,Tile
Foam Tile -On
Metal
Slate
Shingles
-
& Shingles
LeakBarrier Fast90
Yes
Yes
Yes
No
Yes
Yes
See 5.5.2
LeakBarrier MS300
4111110mil
No
No
No
Yes
Yes
LeakBarrier PS200m
Yes
Yes
Yes
Yes
Yes
Yes
See 5.5.2
LeakBarrier P5200`uu
Yes
No
No
Yes
Yes
Yes
Yes
LeakBarrier NR500"r
Yes
No
No
(No copper or
Yes
Yes
zinc)
LeakBarrier SS400
Yes
No
No
No
Yes
Yes
Yes
Yes
LeakBarrier EasyLay
Yes
(as base sheet in
(as base sheet in
Yes
Yes
Yes
multi -ply system)
multi -ply system)
LeakBarrier EasyLay
Yes
Yes
UDL 15, UDL Basic or
Yes
(az base sheet in
(as base sheetin
yes
Yes
Yes
UDL 50
(See FL36884)
multi-plysystem)
multi -ply system)
(See FL16884)
(See FLI6884)
(See FL36884)
Tarco 15
Yes
No
No
Yes
Yes
No
Yes
Yes
Tarco 30
Yes
(as base sheet in
(as base sheet in
Yes
Yes
Yes
multi -ply system)
multi -ply system)
Tarco NO 30
Yes
No
No
Yes
Yes
Yes
(double layer)
(double layer)
(double layer)
(double layer)
Fiberglass Mineral
Yes
Surfaced Roll Roofing
Valley Liner per
No
No
No
No
No
1507.2.9.2(2)
ASTM Organic Mineral
Surface Tile
Yes
Yes
Yes
No
Yes
Yes
Underlayment
See 5.5.2
LeakBarrier EasyMop
Yes
SBS
Yes
Yes
See 5.5.2
No
Yes
Yes
5.5.1 Tarco 15, Tarco 30, Tarco NO 30 and EasyLay may be used as a mechanically attached base layer followed
by a LeakBarrier self -adhering top layer or asphalt -applied ASTM Organic Mineral Surface Tile
Underlayment or LeakBarrier EasyMop SBS with allowable roof covers noted above for the respective top
layer underlaymehts.
5.5.2 "Foam -On Tile" is limited to use of 3M 2-Component Foam Roof Tile Adhesive AH-160 (FL6332)
applications unless tensile adhesion / long term aging data from an accredited testing laboratory is
provided.
Exterior Research and Design, LLC. Evaluation Report 10880.07.08-R8
CertiJ/m[e of Authorization #9503 FL10450-118
Revision 8: 04/18/2016
Page 4 of 10
�J I RINITY I ERD
5.6 Allowable Substrates:
5.6.1 LeakBarrier self -adhering direct -bond to deck:
➢ New untreated plywood (unprimed or primed with ASTM D41 primer);
➢ Existing plywood (unprimed or primed with ASTM D41 primer);
➢ New or existing OSB (unprimed or primed with ASTM D41 primer);
➢ Structural concrete (unprimed or primed with ASTM D41 primer).
Note: Turco does not require priming of new or existing plywood or OSB sheathing. New or existing
plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of LeakBarrier
membranes.
ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS Direct -Bond to Deck:
➢ ASTM D41 primed structural concrete. -
Note: Refer to 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the
overlying roof cover is foam -on tile roofing.
5.6.2 Bond to Mechanically Attached Base Sheet:
LeakBarrier self -adhered to:
➢ ASTM D226, Type I or II felt;
➢ ASTM D4869 felt;
➢ LeakBarrier EasyLay, LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier
EasyLay UDL 50.
ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS in hot asphalt to:
➢ ASTM D226, Type I or 11 felt;
➢ ASTM D4601, Type 11 base sheet.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached
per minimum requirements of FRSA/TRI April 2012 (04-12).
5.6.3 LeakBarrier Self -Adhering Bond to Other Substrate Types:
➢ ASTM D41 primed metal (flashing metal, valley metal, etc.)
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment
systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications.
Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads,
and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has
already been applied). Refer to FBC 1609 for determination of design wind loads.
5.6.4.1 Maximum Design Pressure=-75.0 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHJ
Primer: (Optional) ASTM D41
Base Ply: (Optional) LeakBarrier PS200M0, self -adhered.
Underlayment: LeakBarrier 1)5200Hr, self -adhered.
5.6.4.2 Maximum Design Pressure=-120.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ
Primer: (Optional)ASTM D41
Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200mu or LeakBarrier EasyBase,
rolled into place to create continuous bond
Base Ply: (Optional) LeakBarrier PS200Mv, self -adhered
Underlayment: LeakBarrier PS200HT, self -adhered.
Exterior Research and Design, LLC. I L C Ev I Minn Report 10880.07.08-R8
Certificate of Authodzadon#9503 u "�� FL10450-RB
Revision 8: 04/18/2016
Page 5 of 10
TRINITY I ERD
5.6.4.3 Maximum Design Pressure=-217.5 osf:
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Base Ply: (Optional) LeakBarrier P5200Mu, self -adhered
Underlayment: LeakBarrier PS200n self -adhered.
5.6.4.4 All other direct -deck, adhered Tarco underlayment systems beneath foam -on tile systems carry a
Maximum Design Pressure of -45 psf.
5.6.4.5 Maximum Design Pressure=-45.0 osf•:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide
rolls); See FBC FL16884.
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6" o.c. at the 4-inch wide side laps and 8" o.c. at three (3) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered
Underlayment: LeakBarrier PS200"r, self -adhered.
5.6.4.6 Maximum Design Pressure=-60.0 psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 7" o.c. at the 4-inch wide side laps and 7" o.c. at three (3) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS200mU, self -adhered
Underlayment: LeakBarrier PS2001rr, self -adhered.
5.6.4.7 Maximum Design Pressure = -60.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide
rolls); See FBC FL16884.
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 6" o.c. at the 4-inch wide side laps and 6" o.c. at four (4) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered
Underlayment: LeakBarrier PS200r% self -adhered.
5.6.4.8 Maximum Design Pressure=-82.5 DO
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 8" o.c. at the 4-inch wide side laps and 8" o.c. at four (4) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered
Underlayment: LeakBarrier PS200"r, self -adhered.
5.6.4.9 Maximum Design Pressure = -120.0 Dsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: LeakBarrier EasyLay
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch
diameter tin caps
Spacing: 4" o.c. at the 4-inch wide side laps and 4" o.c. at four (4) equally spaced, staggered center rows.
Base Ply: (Optional) LeakBarrier P5200Mu, self -adhered
Underlayment: LeakBarrier PS200"r, self -adhered.
COPY
Exterior Research and Design, LLL Evaluation Report 10880.07.08-R8
Certy@ate of Authorization #9503 FL10450-RS
Revision 8: 04/18/2016
Page 6 of 10
�! TRINITY I ERD
5.6.4.10 For mechanically attached base sheet in a multi -ply system, the maximum design pressure for the selected
assembly shall, at a minimum, meet or exceed the Zone 1 design pressure determined in accordance with
FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609. Zones 2 and 3 shall employ an attachment
density designed by a qualified design professional to resist the elevated pressure criteria. Commonly
used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD1. Assemblies above marked with an
asterisk* carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements.
5.7 Exposure Limitations:
LeakBarrier Easy Lay, FAST 90, ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier EasyMop
SBS shall not be left exposed for longer than 180-days after installation.
LeakBarrier PS200HT shall not be left exposed for longer than 120-days after installation.
LeakBarrier MS300, NR500'T PS200Mu or SS400 shall not be left exposed for longer than 30-days after
installation
Tarco 15, Tarco 30 and Tarco NO 30 shall be covered as soon as possible after installation; exposure for
more than 24 hours after installation could adversely affect performance.
6. INSTALLATION:
6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and primed the substrate (if applicable).
6.3 LeakBarrier® Fast908 Self -Adhering Tile Underlavment:
6.3.1 EasyLay shall be installed in compliance with the requirements for 90p felt underlayment (except the
product is self -adhered) in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile Applications:
Cut the Fa5t90 roll into 12'to 16'sections for workability and allow to relax prior to application.
Chalk a plumb line 36" from all outside perimeters; then chalk plumb lines 32" apart, upslope to the ridge
line.
Membrane Application:
➢ Place a full width piece of Fast90 on the prepared substrate, parallel to the eave edge of the roof, with
the selvedge edge positioned upslope and in -line with the 1" chalk line.
➢ Fold back half the sheet and remove the exposed release film, taking care not to displace the
membrane
➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles
and ridges, and repeat for the other half of the sheet.
➢ Remove selvage release film, if present, and install capped or tin tagged nails 6" o.c. in the center of the
selvedge edge.
➢ Install the subsequent sheets in the same manner, with upslope selvedge edges in -line with chalk lines,
with 4" side laps and 8" end laps.
➢ Seal all 8" end laps 1/16" thick application of asphalt plastic cement and stagger all end laps minimum
36".
➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave
/ rake areas to ensure a complete bond.
6.3.4 Tile Applications:
a_ Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Wait a minimum of 24 hours prior to loading roof tiles.
Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-118
certificate o)AuthoAration #9503 FL30450-118
Lt � - _ r� ,-y Page 7o
Revision B /f10
RINi-rYI ERD
All tiles shall be staged four tiles perpendicular to slope, six tiles on top, parallel to slope; not to exceed 10
tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a
staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on
top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for
lugged tiles.
At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal
batten.
6.4 LeakBarrier® MS300, PS200"T, PS200Mv, NR500"T or SS400 Ice and Water Armor:
6.4.1 MS 300, PS200"T, PS200M0, NR500"T or SS400 shall be installed in compliance with the requirements for
ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed.
6.4.2 Non -Tile Applications:
Cut MS 300, PS200 HT PS200M", NR500"T or SS400 to manageable sections and allow to relax prior to
application.
Membrane Application:
➢ Place a full width piece on the prepared substrate, aligned parallel to the eave edge and extend
approximately 3/8" over the eave and rake with the selvedge edge positioned upslope.
➢ Fold back the upslope half of the sheet and remove the exposed release film, taking care not to displace
the membrane
➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles
and ridges
➢ Apply a 1/16" thick layer of asphalt plastic cement over the eave and rake metal, extending 2" to 3"
onto the deck surface.
➢ Fold back the downslope half of the sheet, remove the release film and roll the membrane onto the
substrate from the centerline out.
➢ Seal all 6" end laps with a 1/16" thick application of asphalt plastic cement and stagger all end laps
minimum 36".
➢ Remove selvage release film, if present, and install second and subsequent courses in a similar manner.
➢ Install capped or tin -tagged nails 6" o.c. along the centerline of the laps.
➢ At all T-joints, where an end -lap and the next overlapping course intersect, apply a bead of roofing laps
cement before the overlapping course is laid.
➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave
/ rake areas to ensure a complete bond.
6.4.3 Tile Applications(PS200"T only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
Wait a minimum of 24 hours prior to loading roof tiles.
All tiles shall be staged four tiles perpendicular to slope, six tiles on top, parallel to slope; not to exceed 10
tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a
staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on
top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for
lugged tiles.
At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal
batten.
ILL C 10% 2 V�4? Y
Exterior Research and Design, U.C. Evaluation Report 10880.07.08-118
Certfimte o)Authotliation #9503 FL10450-R8
Revision 8: 04/18/2016
Page 8 of 10
�/ I RINITY { ERD
6.4.4 Multi -Ply Underlayment Systems:
LeakBarrier® S5400 Ice and Water Armor followed by LeakBarrier® S5400 Ice and Water Armor (direct -to -
deck per 5.6.1 or over mechanically attached base sheet per 5.6.2) is allowable for use under mechanically
attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not
a requirement, but is allowable if a multi -ply underlayment system is desired.
6.5 Tarco 15 and 30:
6.5.1 Tarco 15 and 30 shall be installed in compliance with the requirements for ASTM D226, Type I and II
underlayments, respectively, in FBC Sections 1507 forthe type of prepared roof covering to be installed.
6.5.2 Non -Tile Applications:
Reference is made to the current edition of the NRCA Steep -slope Roofing Manual.
6.5.3 Tile Applications, base laver in multi -ply system (Tarco 30 only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein.
6.6 Tarco NO 30:
6.6.1 Tarco NO 30 shall be installed in compliance with the requirements for ASTM D4869, Type If underlayment
in FBC Sections 1507 for the type of prepared roof covering to be installed; 1507.4.5.2 (1), 1507.5.3.2 (1),
1507.7.3.2 (1), 1507.8.3.2 (1) or 1507.9.3.2 (1).
6.7 LeakBarrier EasvLay:
6.7.1 Easy Lay shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in
FBC Sections 1507 for the type of prepared roof covering to be installed.
6.7.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application.
6.7.3 Non -Tile Applications:
Place a full width section of Easy Lay, parallel to the eave edge of the roof and unroll 2 to 3 feet with the lay
lines facing up, and position to the edge of the eave and rake. Install a few fasteners at the top, near the
rake, and roll out the sheet to a manageable length. Pull, straighten and align the sheet so that any
wrinkles are eliminated and the sheet is even with the eave edge. Fasten with 3/8" headed roofing nails or
1" capped (plastic or metal) nails, driven by hand or pneumatically, spaced 6" o.c. at all laps in the center
of the seam area, and two staggered rows fastened 12" o.c. in the field of the sheet. Install nails such that
the head of the nail is flush with the surface, without cutting into the surface. Fasten from the top to
avoid walking or kneeling on unsecured sheet. Continue to the end of the substrate and fasten down.
Align the next roll over the preceding sheet so as to form a minimum 4", water -shedding lap, and install
per instructions above. Apply subsequent sheets in the same manner, with minimum 4" water -shedding
laps and minimum 8" end -laps, which are staggered minimum 36" fro the preceding course.
For double layer applications, follow the instructions noted above, but using a minimum 19", water -
shedding side lap.
Allow for minimum 6" up the vertical transitions and minimum 6" over hips and ridges.
At valleys, first install a vertical length of EasyLay down the center of the valley, then start at the low point
and work to the high point, rolling the membrane from the center outward in each direction, ensuring no
wrinkles or tears. Covered with valley -metal or other valley lining material in accordance with NRCA
recommendations.
Apply a thin coat of asphalt plastic cement to waterproof areas where any cuts or tears have occurred.
Seams or joints that requireadhesive or sealant can be treated with high quality plastic cement (asbestos
free).
Exterior Research and Design, I.I.C. PY
Evaluation Repo10880.07.08-R8
Cert%!Cate o/Authorkatiun#9503 FILE FL10450-R8
Revision 8: 04/18/2016
Page 9 of 10
\I TRINITY I ERD
6.7.4 Tile Applications, base laver in multi -ply system:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein.
6.8 ASTM Organic Mineral Surface Tile Underlavment:
6.8.1 Shall be installed in compliance with the requirements for ASTM D6380, Class M sheets in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.8.2 Non -Tile Applications:
Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA
recommendations for installing shingle underlayments and flashings.
6.8.3 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. Tile shall be
loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
6.9 LeakBarrier• EasyMop SBS:
6.9.1 Shall be installed in compliance with current Tarco published installation requirements, subject to the
limitations herein.
6.9.2 Non -Tile Applications:
For mechanically attached applications: Secure LeakBarrier EasyMop SBS using 3/8-inch headed roofing
nails or 1-inch diameter cap -nails spaced 9-inch o.c. within the 4-inch wide side laps and 12-inch o.c. in two
(2) equally spaced, staggered center rows in the center of the sheet. End -laps shall be minimum 6-inch
wide, and offset end -laps minimum 3-feet from course to course. Seal end laps in accordance with Tarco
requirements.
For bonded applications: Fully adhere LeakBarrier EasyMop SBS in hot -asphalt to the substrates noted in
Section 5.5. Side laps shall be minimum 4-inch and end -laps minimum 6-inch wide, and offset end -laps
minimum 3-feet from course to course. Side and end -laps shall be fully adhered in a complete mopping of
hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. Consult Tarco
instructions regarding back -nailing requirements.
6.9.3 Tile Applications:
Refer to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. Tile shall be loaded and
staged in a manner that prevents tile slippage and/or damage to the underlayment.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements
9. QUALITY ASSURANCE ENTITY:
UL, LLC. — QUA9625; (847) 664-3281
END OF EVALUATION REPORT -
Exterior Research and Design, U.C. Evaluation Report 10880.07.08-118
Ceniftate of Authorization h9503 FL10450-Rg
Revision 8: 04/18/2016
Page 10 of 10