Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Page 1 of 2 t SCANNED BY St Lucie f'nunfi ii° ��, 8MHam. Log In I User Registration Hot Tapirs Submit Surchage I Stats&Facts I Publicamns I FBC Stall I BM site Map I Links search dbprIfl Product ApprovalUSER: Public Userty1f�9. (eft I I r�fg.J{xl Pmdue A.omval Menu>Pratluc[.rP..Ika[lon search >R.olicatlon lht>Appltradon Detail 1 Yam„ 0C - 711 FL # FL11351-R5 f (C7�` Application Type Revision rC.=J✓\v\ Code Version 2014 Application Status Approved Comments Archived O Product Manufacturer Englert Inc. Address/Phone/Email 1200 Amboy Ave. Perth Amboy, NJ 08861 (732) 826-8614 Ext 3909 J.tripod@englertinc.com Authorized Signature James Buckner jimmy@cbuckinc.net Technical Representative Joseph F. Tripod Address/Phone/Email 1200 Amboy Avenue Perth Amboy, NJ 08862 (732) 826-8614 jftripod@aol.com Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Roofing 91 RI Underlaymenfs RI + Evaluation Report from a Florida Registered Architect or a Licensed' G� Florida Professional Engineer 2 Evaluation Report - Hardcopy Received James L. Buckner, P.E @ CBUCK, Inc. PE-31242 Keystone Certifications, Inc. 12/31/2019 Steven M. Urich, PE 2 Validation Checklist - Hardcopy Received FL11351 R5 COI CertOfindeo.odf Standard Year ASTM D. 1970 - -2009 Florida Licensed Professional Engineer or Architect FL11351 RS Eauiv Test Standard Eauiv.udf 41,,.:A.,1.,,:l.4.*—,,,,,,, A+l STt15CV(71lA G/17M1117 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 04/27/2015 04/30/2015 05/06/2015 06/22/2015 FL # Model, Number or Name Description 11351.1 "Englert HT" SBS Self -Adhered Roof Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL11351 RS II 1 HT Underlayment EVALREPORT odf Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E. Approved for use outside HVHZ: Yes Impact Resistant: N/A #31242 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to Evaluation Report for Conditions and Evaluation Reports Limitations of Use. Refer to manufacturer's installation FL11351 R5 AE 1 HT Underlayment EVALREPORT.odf Created by Independent Third Party: Yes Instructions as a supplemental guide. 11351.2 "MetalMan HT-60" SBS Self -Adhered Roof Underlayment Limits of Use Installation Instructions Approved for use in HVHZ: No FL11351 RS II 2 HT60 Underlayment EVALREPORT.odf Verified By: James L. Buckner, P.E. P.E. #31242 Approved for use outside HVHZ: Yes Impact Resistant: N/A Created by Independent Third Party: Yes Design Pressure: N/A Evaluation Reports Other: Refer to Evaluation Reportfor Conditions and FL11351 R5 AE 2 HT60 Underlayment EVALREPORT odf Created by Independent Third Party: Yes Limitations of Use. Refer to manufacturer's Installation Instructions as a supplemental guide. Back Nezt CnptactUs :: 2601 Blair Stone Road, Tallahassee FL 323" Phone: 1150-057- The State of Florida is an A VEBO employer. Coovdoht 2007-2013 State of Hard,.:: Privacy Statement :: Acoessibllty Statement :: Refund Statement Oder nodda low, email addresses are public returns. If you do not wart your e-mail address released in response to a publit-recoMs raivact, do not send cbonlc mail to th6 entity. Instead, contact Me office by phone or by traditional mall. if you have any questions, please canted 850.487.1395..Pursuant to Ion 455.275(1), Florida Statutes, effective October 1, 2012, licensees llcensad under Chapter 455, F.S. mulirflorpa the Department with an email address if they have one. The malls provided may be used for official communication with the licensee. How supply a personal address, please provide the Department with an email adds which can be made Chapter 455, F.S., please click here . product Approval Accepts: Credit Card Safe 19 httDs://www.floridabuildiniz.ore/Dr/Dr aou dtl.asnx?Daram=wGEVXOwtDovIL5K15SWld... 5/12/2017 Co� CK SpsrJc9fi,Lj Struc4urcsl EnglnsL=rIric3 Evaluation Report "Englert° HT" Roof Underlayment Manufacturer: Englert, Inc. 1200 Amboy Avenue Perth Amboy, NJ 08862 (732)826-8614 for Florida Product Approval # FL 11351.1115 CBUCK, Inc. Certificate of Authorization #8064 Florida Building Code Sth Edition (2014) Method: Category: Sub - Category: 1 - D Roofing Underlayment Product: Product Type: SBS Self-AdhereftEn { u+ ! y Prepared by: v�.ssm.oxsa trio«aw.sue..aaa E James L. Buckner,.P.E., S.E.C.B. BUC S L. BUCk�., UctNSF••..F,P'-, �P_: Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 No aizaz Project Manager: Diana Galloway Report No. 15-126-HT-ER �'., STATE OF .•tu (Revises s'ONAtE�` Date: 4/02/15f Contents:C Evaluation Report Pages 1-5 MeuDv9MOd b. hoof L Be 0, V.E. 2015.04.27 0958:14-04'00' CBUCK, Inc. 1399 N. Killian Drive, Suite 4, West Palm Beach, Florida 33403 Phone: (561)491-9927 Fax: (561)491-9928 Website: www.cbuckinc.net FL #: FL 11351.1 R4 flr�� rift Date: 4 / 2 / 15 BUCK E U qg Ut2'�G Il�� Page Report No.: 2 of 56-HT-ER 5=P'�rJ—e5)9 W SftL CtUTc!gI eno-Ismering CBUCK, Inc. Certificate of Authorizotlon #8064 Manufacturer: Englert, Inc. Product Name: "Englert HT" Product Category: Roofing Product Sub -Category Underlayment Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product Description: "Englert HT" is a self -adhering membrane composed of SBS modified bitumen and a UV resistant anti -slip polyethylene woven top facer designed for use as a roof underlayment in high temperature conditions. "Englert HT" may be used with metal roofing, asphalt shingles, slate, simulated slate, tile or wood shakes & shingles. Product Material/ Material Type: Styrene Butadiene Styrene (SBS) Standards: Material shall comply with ASTM D 1970 per Florida Building Code (FBC), 5th Edition (2014), Chapter 15. Product Dimension(s) Roll Size:36 in. x 67 ft. rolls Thickness: 40 mils minimum Substrate(s): "Englert HT" may be applied to the following sub � n (Design of substrate outside the scope of this ev uati $� • Plywood • Wood plank • OSB • Structural Concrete • Gypsum Board • Masonry • Galvanized metal Installation: Englert, Incs "Englert HT" shall be installed in accordance with the attached installation method and in compliance with applicable code sections of the Florida Building Code, 5th Edition (2014), subject to the System Limitations listed in this Evaluation Report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA 1824). FL q: FL 11351.1 R4 (�(�1� r� ���ftr� Date: 4 / 2 / 15 SUCK E gg E%ss)l 9 U` ^J Page Report No.: 3 of 56-HT-ER r=PFcJc5 W SfrUC't`L.ITd) EngInsering CBUCK, Inc. Certificate of Authorization #8a64 Performance Standards: The product described herein has been tested in accordance with: • ASTM D 1970-09 —Specification Self -adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the prescribed standards in ASTM D 1970-09 standard version adopted by the Florida Building Code 5th Edition (2014) for use as evaluated in this report. Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 5th Edition (2014), standard ASTM D 1970-09. Evaluation Report Scope: This product has been evaluated in compliance with the building envelope requirements of the Florida Building Code, as related to the scope section of Florida Product Approval Rule 61G20-3.001. Product Limitations and • Deck shall be in compliance with applicable building code. Conditions of Use: • Minimum slope shall be 2:12 or greater. • Products are evaluated for use with approved roof coverings that are mechanically fastened through the underlayment and is attached to the sheathing or rafters. For use with tile roof i{ ssttallation, refer to FRSA/TRI Florida Nigh Wind Clay and Concrete Roof 1 1r all T Edition per FBC 1507.3.3 and 1507.3.3.1.Y• Do not expose product to direct sunlight for more than ys. General Limitations and • Scope of "Limitations and Conditions of Use' for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61620-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval". • Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be,the responsibility of others. • Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) r FL M FL 11351.1 R4 (�(� }�r�i ro Date: 4 / 2 / 15 l�� lJ` `=JJU u�� UU uJ Page Report No.: 4 of 56 HT -ER SpEx--lafi d Structural Englorm2oringi CBUCK, Inc. Certificate of Authorization NB064 Referenced Data: 1. ASTM D 4798-04 & ASTM D 1970-01 Test By Trinity ERD, (FBC Organization #TST ID: 6049) Report M E12330.01.09, Report Date: 1/14/09 2. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering 3. Quality Assurance By Keystone Certifications, Inc. (FBC Organization #QUA ID:1824) 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE ID: 1916) J FL #: FL 11351.1 R4 �� Date: 4 / 2 / 15 l� lJl�tt vu ill t �� 1 tlJ Report No.: 5 of 56-HT-ER Page r=pEK Icslhj S1ru=tural Fete, 1nsgsriric;l CBUCK,Inc. Certificate of Authorization N8064 INSTALLATION METHOD "Englert HT" Self -Adhered Roofing Underlayment � General Installation Instructions: -- ill C P • Prime surface as recommended by manufacturer. • Align the membrane, by completely unrolling and pressing exposed membrane area into place. • Once aligned, wind back one half of the length. • Score the release film on the high side of the roll. • Unroll the first half of the roll by peeling back the release film and simultaneously pushing out the membrane. • Repeat this procedure with the remaining half of the length. • Firmly roll installed membrane using uniform pressure with a 2-3" heavy steel or rubber roller to seams and overlap. • Side laps must be a minimum of 3" and End laps a minimum of 6". • Product to be applied directly to a clean dry surface. • Dust, dirt, oil, grease, moisture, debris and other loose materials or contaminants must be removed prior to application. • Check that all nails in deck are not protruding and re -fasten any loose decking panels. • Product shall not be permanently exposed to sunlight. • Do not store underlayment in areas where moisture is a problem. • Protect membrane from damage Auring construction. • Apply membrane only in fair weather when the air, surface and membrane are at temperatures of 40 degrees Fahrenheit and higher. • "Englert HT" shall not be left exposed for more than 90 days after installation. • "Englert HT" may be used with asphalt shingles, metal roofing, slate, simulated slate, tile or wood shakes & shingles. • Installation with tile roofs shall be in compliance with FRSA/TRI Florida High Wind Clay and Concrete Roof Tile Installation Manual, Fifth Edition, per FBC 1507.3.3 and 1507.3.3.1. Product shall be installed. in accordance with the installation method described herein and in compliance with applicable code sections of the Florida Building Code 5th Edition (2014), subject to the Limitations and Conditions of Use listed in this Evaluation Report. Refer to manufacturer's installation instructions as a supplemental guide for attachment.