HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Page 1 of 2
t
SCANNED
BY
St Lucie f'nunfi ii°
��,
8MHam. Log In I User Registration Hot Tapirs Submit Surchage I Stats&Facts I Publicamns I FBC Stall I BM site Map I Links search
dbprIfl Product ApprovalUSER: Public Userty1f�9. (eft I I r�fg.J{xl
Pmdue A.omval Menu>Pratluc[.rP..Ika[lon search >R.olicatlon lht>Appltradon Detail 1 Yam„
0C - 711 FL # FL11351-R5 f (C7�`
Application Type Revision rC.=J✓\v\
Code Version 2014
Application Status Approved
Comments
Archived O
Product Manufacturer Englert Inc.
Address/Phone/Email 1200 Amboy Ave.
Perth Amboy, NJ 08861
(732) 826-8614 Ext 3909
J.tripod@englertinc.com
Authorized Signature James Buckner
jimmy@cbuckinc.net
Technical Representative Joseph F. Tripod
Address/Phone/Email 1200 Amboy Avenue
Perth Amboy, NJ 08862
(732) 826-8614
jftripod@aol.com
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Roofing 91 RI
Underlaymenfs RI +
Evaluation Report from a Florida Registered Architect or a Licensed' G�
Florida Professional Engineer
2 Evaluation Report - Hardcopy Received
James L. Buckner, P.E @ CBUCK, Inc.
PE-31242
Keystone Certifications, Inc.
12/31/2019
Steven M. Urich, PE
2 Validation Checklist - Hardcopy Received
FL11351 R5 COI CertOfindeo.odf
Standard Year
ASTM D. 1970 - -2009
Florida Licensed Professional Engineer or Architect
FL11351 RS Eauiv Test Standard Eauiv.udf
41,,.:A.,1.,,:l.4.*—,,,,,,, A+l STt15CV(71lA G/17M1117
Florida Building Code Online
Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
04/27/2015
04/30/2015
05/06/2015
06/22/2015
FL #
Model, Number or Name
Description
11351.1
"Englert HT"
SBS Self -Adhered Roof Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11351 RS II 1 HT Underlayment EVALREPORT odf
Verified By: James L. Buckner, P.E. @ CBUCK, Inc P.E.
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
#31242
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to Evaluation Report for Conditions and
Evaluation Reports
Limitations of Use. Refer to manufacturer's installation
FL11351 R5 AE 1 HT Underlayment EVALREPORT.odf
Created by Independent Third Party: Yes
Instructions as a supplemental guide.
11351.2
"MetalMan HT-60"
SBS Self -Adhered Roof Underlayment
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11351 RS II 2 HT60 Underlayment EVALREPORT.odf
Verified By: James L. Buckner, P.E. P.E. #31242
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: N/A
Evaluation Reports
Other: Refer to Evaluation Reportfor Conditions and
FL11351 R5 AE 2 HT60 Underlayment EVALREPORT odf
Created by Independent Third Party: Yes
Limitations of Use. Refer to manufacturer's Installation
Instructions as a supplemental guide.
Back Nezt
CnptactUs :: 2601 Blair Stone Road, Tallahassee FL 323" Phone: 1150-057-
The State of Florida is an A VEBO employer. Coovdoht 2007-2013 State of Hard,.:: Privacy Statement :: Acoessibllty Statement :: Refund Statement
Oder nodda low, email addresses are public returns. If you do not wart your e-mail address released in response to a publit-recoMs raivact, do not send
cbonlc mail to th6 entity. Instead, contact Me office by phone or by traditional mall. if you have any questions, please canted 850.487.1395..Pursuant to
Ion 455.275(1), Florida Statutes, effective October 1, 2012, licensees llcensad under Chapter 455, F.S. mulirflorpa the Department with an email address if
they have one. The malls provided may be used for official communication with the licensee. How
supply a personal address, please provide the Department with an email adds which can be made
Chapter 455, F.S., please click here .
product Approval Accepts:
Credit Card
Safe
19
httDs://www.floridabuildiniz.ore/Dr/Dr aou dtl.asnx?Daram=wGEVXOwtDovIL5K15SWld... 5/12/2017
Co� CK
SpsrJc9fi,Lj Struc4urcsl EnglnsL=rIric3
Evaluation Report
"Englert° HT"
Roof Underlayment
Manufacturer:
Englert, Inc.
1200 Amboy Avenue
Perth Amboy, NJ 08862
(732)826-8614
for
Florida Product Approval
# FL 11351.1115
CBUCK, Inc. Certificate of Authorization #8064
Florida Building Code Sth Edition (2014)
Method:
Category:
Sub - Category:
1 - D
Roofing
Underlayment
Product:
Product Type: SBS Self-AdhereftEn
{ u+
! y
Prepared by:
v�.ssm.oxsa trio«aw.sue..aaa
E
James L. Buckner,.P.E., S.E.C.B.
BUC
S L. BUCk�.,
UctNSF••..F,P'-,
�P_:
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
No aizaz
Project Manager: Diana Galloway
Report No. 15-126-HT-ER
�'., STATE OF .•tu
(Revises
s'ONAtE�`
Date: 4/02/15f
Contents:C
Evaluation Report Pages 1-5
MeuDv9MOd b. hoof L Be 0, V.E.
2015.04.27 0958:14-04'00'
CBUCK, Inc.
1399 N. Killian Drive, Suite 4, West Palm Beach, Florida 33403
Phone: (561)491-9927 Fax: (561)491-9928 Website: www.cbuckinc.net
FL #: FL 11351.1 R4
flr�� rift Date: 4 / 2 / 15
BUCK E U qg Ut2'�G Il�� Page Report No.: 2 of 56-HT-ER
5=P'�rJ—e5)9 W SftL CtUTc!gI eno-Ismering CBUCK, Inc. Certificate of Authorizotlon #8064
Manufacturer: Englert, Inc.
Product Name: "Englert HT"
Product Category: Roofing
Product Sub -Category Underlayment
Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d)
Product Description: "Englert HT" is a self -adhering membrane composed of SBS modified bitumen and
a UV resistant anti -slip polyethylene woven top facer designed for use as a roof
underlayment in high temperature conditions. "Englert HT" may be used with
metal roofing, asphalt shingles, slate, simulated slate, tile or wood shakes &
shingles.
Product Material/ Material Type: Styrene Butadiene Styrene (SBS)
Standards: Material shall comply with ASTM D 1970 per Florida Building Code (FBC), 5th
Edition (2014), Chapter 15.
Product Dimension(s) Roll Size:36 in. x 67 ft. rolls
Thickness: 40 mils minimum
Substrate(s): "Englert HT" may be applied to the following sub �
n
(Design of substrate outside the scope of this ev uati $�
• Plywood
• Wood plank
• OSB
• Structural Concrete
• Gypsum Board
• Masonry
• Galvanized metal
Installation: Englert, Incs "Englert HT" shall be installed in accordance with the attached
installation method and in compliance with applicable code sections of the
Florida Building Code, 5th Edition (2014), subject to the System Limitations listed
in this Evaluation Report.
Refer to manufacturer's installation instructions as a supplemental guide for
attachment.
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA
1824).
FL q: FL 11351.1 R4
(�(�1� r� ���ftr� Date: 4 / 2 / 15
SUCK E gg E%ss)l 9 U` ^J Page Report No.: 3 of 56-HT-ER
r=PFcJc5 W SfrUC't`L.ITd) EngInsering CBUCK, Inc. Certificate of Authorization #8a64
Performance Standards: The product described herein has been tested in accordance with:
• ASTM D 1970-09 —Specification Self -adhering Polymer Modified Bituminous
Sheet Materials Used as Steep Roof Underlayment for Ice Dam Protection
Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the
prescribed standards in ASTM D 1970-09 standard version adopted by the
Florida Building Code 5th Edition (2014) for use as evaluated in this report.
Code Compliance: The product described herein has demonstrated compliance with the Florida
Building Code 5th Edition (2014), standard ASTM D 1970-09.
Evaluation Report Scope: This product has been evaluated in compliance with the building envelope
requirements of the Florida Building Code, as related to the scope section of
Florida Product Approval Rule 61G20-3.001.
Product Limitations and • Deck shall be in compliance with applicable building code.
Conditions of Use: • Minimum slope shall be 2:12 or greater.
• Products are evaluated for use with approved roof coverings that are
mechanically fastened through the underlayment and is attached to the
sheathing or rafters. For use with tile roof i{ ssttallation, refer to FRSA/TRI
Florida Nigh Wind Clay and Concrete Roof 1 1r all T
Edition per FBC 1507.3.3 and 1507.3.3.1.Y• Do not expose product to direct sunlight for more than ys.
General Limitations and • Scope of "Limitations and Conditions of Use' for this evaluation:
Conditions of Use: This evaluation report for "Optional Statewide Approval' contains
technical documentation, specifications and installation method(s) which
include "Limitations and Conditions of Use" throughout the report in
accordance with Rule 61G20-3.005. Per Rule 61620-3.004, the Florida
Building Commission is the authority to approve products under
"Optional Statewide Approval".
• Option for application outside "Limitations and Conditions of Use"
Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with
the alternate methods and materials authorized in the Code". Any
modification of the product as evaluated in this report and approved by
the Florida Building Commission is outside the scope of this evaluation
and will be,the responsibility of others.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in
the High Velocity Hurricane Zone code section. (Dade & Broward
Counties)
r
FL M FL 11351.1 R4
(�(� }�r�i ro Date: 4 / 2 / 15
l�� lJ` `=JJU u�� UU uJ Page Report No.: 4 of 56 HT -ER
SpEx--lafi d Structural Englorm2oringi CBUCK, Inc. Certificate of Authorization NB064
Referenced Data: 1. ASTM D 4798-04 & ASTM D 1970-01 Test
By Trinity ERD, (FBC Organization #TST ID: 6049)
Report M E12330.01.09, Report Date: 1/14/09
2. Equivalency of Test Standard Certification
By James L. Buckner, P.E. @ CBUCK Engineering
3. Quality Assurance
By Keystone Certifications, Inc. (FBC Organization #QUA ID:1824)
4. Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE ID: 1916)
J
FL #: FL 11351.1 R4
�� Date: 4 / 2 / 15
l� lJl�tt vu ill t �� 1 tlJ Report No.: 5 of 56-HT-ER
Page
r=pEK Icslhj S1ru=tural Fete, 1nsgsriric;l CBUCK,Inc. Certificate of Authorization N8064
INSTALLATION METHOD
"Englert HT"
Self -Adhered Roofing Underlayment �
General Installation Instructions: -- ill
C P
• Prime surface as recommended by manufacturer.
• Align the membrane, by completely unrolling and pressing exposed membrane area into
place.
• Once aligned, wind back one half of the length.
• Score the release film on the high side of the roll.
• Unroll the first half of the roll by peeling back the release film and simultaneously
pushing out the membrane.
• Repeat this procedure with the remaining half of the length.
• Firmly roll installed membrane using uniform pressure with a 2-3" heavy steel or rubber
roller to seams and overlap.
• Side laps must be a minimum of 3" and End laps a minimum of 6".
• Product to be applied directly to a clean dry surface.
• Dust, dirt, oil, grease, moisture, debris and other loose materials or contaminants must
be removed prior to application.
• Check that all nails in deck are not protruding and re -fasten any loose decking panels.
• Product shall not be permanently exposed to sunlight.
• Do not store underlayment in areas where moisture is a problem.
• Protect membrane from damage Auring construction.
• Apply membrane only in fair weather when the air, surface and membrane are at
temperatures of 40 degrees Fahrenheit and higher.
• "Englert HT" shall not be left exposed for more than 90 days after installation.
• "Englert HT" may be used with asphalt shingles, metal roofing, slate, simulated slate, tile
or wood shakes & shingles.
• Installation with tile roofs shall be in compliance with FRSA/TRI Florida High Wind Clay
and Concrete Roof Tile Installation Manual, Fifth Edition, per FBC 1507.3.3 and
1507.3.3.1.
Product shall be installed. in accordance with the installation method described herein and in
compliance with applicable code sections of the Florida Building Code 5th Edition (2014), subject to
the Limitations and Conditions of Use listed in this Evaluation Report.
Refer to manufacturer's installation instructions as a supplemental guide for attachment.