HomeMy WebLinkAboutPROJECT REPORTJUHNNED sy . "^iP County QP File R18970 Project 09NK03846 PROJECT 09CA30617 Project 4786458989 Issued: March 31, 2009 Revised: June 12, 2014 REPORT on Roofing Systems Under The FILE CLASSIFICATION PROGRAM Englert Inc. Perth Amboy, NJ Copyright0 2009 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above named company to reproduce this Report provided it is reproduced in its entirety. L File R18970 Page GI Issued: 2009-03-31 Revised: 2014-06-12 GENERAL INVESTIGATION: *The subject of this Report is roofing systems consisting of steel roof deck panels. The metal roof deck panels were designated ""Series 1100, 1101, 1300, 2000 or 2500" The object of this investigation was to establish the external fire exposure Classification for the roofing systems described in this Report. The evaluation was conducted in accordance with the Standard UL 790, Eighth Edition, entitled "Standard Test Methods or Fire Tests of Roof Coverings" and to evaluate metal roof panels in accordance with UL2218, First Edition entitled "Impact Resistance of Prepared Roof Covering Material". � �i File R18970 TEST RECORD NO. 3 SAMPLE: Page T3-1 of 1 Metal roof deck panels designated "Series 1000". STUDY FOR CLASSIFICATION PURPOSES: Issued: 2009-03-31 New: 2014-06-12 Testing of the metal roof deck panels designated "Series 1000" for use in Roofing Systems and Impact Resistance was not considered necessary based upon the testing conducted under Test Record No. 2. TEST RECORD 3 SUMMARY: The results of this investigation indicate that the metal panels evaluated in this test record comply with applicable requirements, and therefore, are judged to be eligible for Classification under the Laboratories product categories of Roofing Systems (TGFU) and Impact Resistance (TGAM). Edition or Latest Revision Publication Date Standard Title Date ANSI/UL Standard Test Methods or Fire 790 Tests of Roof Coverings Eight July 17, 2013 ANSI/UL Standard for Impact Resistance 2218 of Prepared Roof Covering First January 25, 2002 Materials The Classification Mark for the TGFU category (UL 79FtLFd C the "Series 1000" panel is illustrated below: () P1 I g BUILDING UNITS FOR ROOFING SYSTEMS AS TO EXTERNAL FIRE EXPOSURE SEE UL ONLINE CERTIFICATIONS DIRECTORY The Classification Mark for the TGAM category (UL2218) to be used on the product is illustrated below: "Also Classified as to Impact Resistance: Class 4" Test Record 3 By: Reviewed by: �-� � 9 ALPESH PATEL Staff Engineer Kenneth D. Rhodes Senior Staff Engineer Any information and documentation involving the UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL File R18970 Page Cl Issued: 2009-03-31 Revised: 2014-06-12 CONCLUSION: The products covered by this Report have been investigated and are judged to be eligible for publication under UL's product categories for Roofing Systems. Products identified in this Report as being Listed or Classified, are covered independently under Listing or Classification and Follow -Up Service. Only those products that properly bear the UL Mark are considered as Listed or Classified by Underwriters Laboratories Inc. The Classification Mark for the TGFU category (UL 790)and TGAM category (UL2218) to be used on the "Series 1006, 1100, 1101, 1300, 2000 or 2500" panels is illustrated below: *BUILDING UNITSFOR ROOFING SYSTEMS AS TO EXTERNAL FIRE EXPOSURE OTHER SYSTEMS Class A 1. Deck: C-15/32 or spaced Incline: Unlimited Impact: 4 sheathing Underlayment: - One layer "VersaShield Underlayment", mechanically fastened. Ply Sheet: - One layer Type 30 base sheet or "VersaShield", mechanically fastened. LecF Panels: - "Series 1000, 1100, 1101, 1300, 2000 or 2 ecic lly ICGYy�� fastened. 2. Deck: C-15/32 or Incline: Unlimited Impact: 4 spaced sheathing Underlayment: - One or more plies "VersaShield Underlayment", mechanically fastened. Panels: - "Series 1000, 1100, 1101, 1300, 2000 or 2500", mechanically fastened. 3. Deck: C-15/32 Incline: Unlimited Impact: 4 Barrier Board: - 1/4 in. min. G-P Gypsum DensDeckO with all joints staggered a min of 6 in. from the plywood joints. Insulation (Optional): - Fiberglass, polyisocyanurate, perlite or wood fiber, any thickness. Membrane: - Any UL Classified modified bitumen system, BUR system or CPE, CSM, CSPE, EPDM, NBP, PIS, PVC, TPO or THE membrane system suitable for use with any roof insulation. Panels: - "Series 1000, 1100, 1101, 1300, 2000 or 2500", mechanically fastened.