HomeMy WebLinkAboutPROJECT REPORTJUHNNED
sy .
"^iP County QP
File R18970
Project 09NK03846
PROJECT 09CA30617
Project 4786458989
Issued: March 31, 2009
Revised: June 12, 2014
REPORT
on
Roofing Systems
Under The
FILE
CLASSIFICATION PROGRAM
Englert Inc.
Perth Amboy, NJ
Copyright0 2009 Underwriters Laboratories Inc.
Underwriters Laboratories Inc. authorizes the above named company to
reproduce this Report provided it is reproduced in its entirety.
L
File R18970 Page GI Issued: 2009-03-31
Revised: 2014-06-12
GENERAL
INVESTIGATION:
*The subject of this Report is roofing systems consisting of steel roof
deck panels. The metal roof deck panels were designated ""Series 1100, 1101,
1300, 2000 or 2500"
The object of this investigation was to establish the external fire
exposure Classification for the roofing systems described in this Report.
The evaluation was conducted in accordance with the Standard UL 790, Eighth
Edition, entitled "Standard Test Methods or Fire Tests of Roof Coverings" and
to evaluate metal roof panels in accordance with UL2218, First Edition
entitled "Impact Resistance of Prepared Roof Covering Material".
� �i
File R18970
TEST RECORD NO. 3
SAMPLE:
Page T3-1 of 1
Metal roof deck panels designated "Series 1000".
STUDY FOR CLASSIFICATION PURPOSES:
Issued: 2009-03-31
New: 2014-06-12
Testing of the metal roof deck panels designated "Series 1000" for use in
Roofing Systems and Impact Resistance was not considered necessary based upon
the testing conducted under Test Record No. 2.
TEST RECORD 3 SUMMARY:
The results of this investigation indicate that the metal panels
evaluated in this test record comply with applicable requirements, and
therefore, are judged to be eligible for Classification under the
Laboratories product categories of Roofing Systems (TGFU) and Impact
Resistance (TGAM).
Edition or
Latest Revision
Publication
Date
Standard
Title
Date
ANSI/UL
Standard Test Methods or Fire
790
Tests of Roof Coverings
Eight
July 17, 2013
ANSI/UL
Standard for Impact Resistance
2218
of Prepared Roof Covering
First
January 25, 2002
Materials
The Classification Mark for the TGFU category (UL 79FtLFd C
the "Series 1000" panel is illustrated below:
() P1 I g
BUILDING UNITS
FOR ROOFING SYSTEMS
AS TO EXTERNAL FIRE EXPOSURE
SEE UL ONLINE CERTIFICATIONS DIRECTORY
The Classification Mark for the TGAM category (UL2218) to be used on
the product is illustrated below:
"Also Classified as to Impact Resistance: Class 4"
Test Record 3 By: Reviewed by:
�-� � 9
ALPESH PATEL
Staff Engineer
Kenneth D. Rhodes
Senior Staff Engineer
Any information and documentation involving the UL Mark services are provided
on behalf of UL LLC (UL) or any authorized licensee of UL
File R18970 Page Cl Issued: 2009-03-31
Revised: 2014-06-12
CONCLUSION:
The products covered by this Report have been investigated and are
judged to be eligible for publication under UL's product categories for
Roofing Systems. Products identified in this Report as being Listed or
Classified, are covered independently under Listing or Classification and
Follow -Up Service. Only those products that properly bear the UL Mark are
considered as Listed or Classified by Underwriters Laboratories Inc.
The Classification Mark for the TGFU category (UL 790)and TGAM category
(UL2218) to be used on the "Series 1006, 1100, 1101, 1300, 2000 or 2500"
panels is illustrated below:
*BUILDING UNITSFOR ROOFING SYSTEMS
AS TO EXTERNAL FIRE EXPOSURE
OTHER SYSTEMS
Class A
1. Deck: C-15/32 or spaced Incline: Unlimited Impact: 4
sheathing
Underlayment: - One layer "VersaShield Underlayment", mechanically
fastened.
Ply Sheet: - One layer Type 30 base sheet or "VersaShield",
mechanically fastened. LecF
Panels: - "Series 1000, 1100, 1101, 1300, 2000 or 2 ecic lly ICGYy��
fastened.
2. Deck: C-15/32 or Incline: Unlimited Impact: 4
spaced sheathing
Underlayment: - One or more plies "VersaShield Underlayment",
mechanically fastened.
Panels: - "Series 1000, 1100, 1101, 1300, 2000 or 2500", mechanically
fastened.
3. Deck: C-15/32 Incline: Unlimited Impact: 4
Barrier Board: - 1/4 in. min. G-P Gypsum DensDeckO with all joints
staggered a min of 6 in. from the plywood joints.
Insulation (Optional): - Fiberglass, polyisocyanurate, perlite or wood
fiber, any thickness.
Membrane: - Any UL Classified modified bitumen system, BUR system or
CPE, CSM, CSPE, EPDM, NBP, PIS, PVC, TPO or THE membrane system
suitable for use with any roof insulation.
Panels: - "Series 1000, 1100, 1101, 1300, 2000 or 2500", mechanically
fastened.