Loading...
HomeMy WebLinkAboutROOFING SUBMITTALDate: March 23rd, 2017 SCAN(YED SY St. 1 11" 10 r nlinh, Roofing Submittal Project Name: Savanna's Preserve State Park S BY ED St Lucie rolint, WSE• PLANS AND ALL PROPOSED WORK ARE SU31f:CT TO ANY CORaCTIONS REOUIREII DY HUD IN,MfCTOi15 THAT MAYBE NECESSARY IN ORDER TO COMP6l WITH Ali, APPIJCADLE CODES, 9551 Gumbo Limbo Lane Jensen Beach, FL 34957 ST. LUCIE COILNit1P BLDG:j DATE d State of Florida Department EC', DATE: Of Environmental Protection , PLUMl 3900 Commonwealth Boulevard, MS #520 DATE. Tallahassee, FL 32399-3000 MECH DATE: I would like introduce our Team that will handle all Permitting/Inspections, Field Operations, Billing, and Project Management/Submittals/Change -- r ers or rs prolec . Permitting/Inspections: Jasmine Rivera 0-561-223-2096 F-561-444-2272 jrivera@thermasealroofs.com COHOILRD FASTENERS OR ATTACHMENTS ARE THE RESPONSISILay OF THE CONTRACTOR OF RECORD WJGP Structural Group, Inc. Review of Shop Drawings or samples is only for conformance with the design concept of.the project and does not relieve the Contractor of, responsibility for any deviation from requirements of the Contract Documents nor from responsibility for errors or omissions in the Shop Drawings or Samples. Contractor shall determine and verify all field measurements, field construction criteria,_ quantities, materials, catalog numbers and similar dots, check and coordinate each Shop Drawing and sample with the requirements of the work and of the ��Con//tract Documeenntts{,r�1�,,' lJ�"Approved "` P"� I '0 f 0 Revise and resubmit _`L_f Approved_ as noted ❑ No�t �¢r�oIv d� Signature �� Date �7""i—'—'— MaRn Office: 1421 Oglethoroe Rd. ' West Palm.BeSch, FL 33405 • Tel: 56t.223.2096 - Fax: 561.4}14.2272 License # CCC1328620 Solutions Driven and Customer Focused Replace Roof Savannas Preserve State Park Park Manager Residence SECTION 07612 - SHEET METAL ROOFING, ALUMINUM (040) PARTI-GENERAL 1.1 SECTION REQUIREMENTS Project #61007 A. Submittals: A comprehensive package of product data, shop drawings, material samples, color samples and any additional information required to fully describe the contractor's intent. Refer to article 24 of the General Conditions. B. Comply with SMACNA's "Architectural Sheet Metal Manual" unless otherwise indicated. C. Roof system shall meet minimum wind uplift resistance as required by the Florida Building Code. D. Roof system shall have Florida Product Approval for components and cladding or Miami -Dade Notice of Approval. E. Quality Assurance: Installer Qualifications: Utilize an installer having demonstrated experience on projects of similar size and complexity. yy�� PART 2 -PRODUCTS F I L t..t � !I PY 2.1 ROOFING SHEET METALS A. Aluminum Sheet: Fabricated from aluminum sheet, ASTM B 209M for alclad Alloy 3105; 0.040 inch thick. (Panel size can be manufacturer's standard, guaranteeing that it meets wind uplift criteria and resists oil -panning.) Products (Basis of Design): a. Englert Metal Roofing, Series S2500. Panels shall be 2" high, 12" wide, with mechanically seamed system. 1) Contact: 1200 Amboy Avenue, Perth Amboy, NJ 08862; Telephone: (800) 610-1975, (732) 826-8614; Fax: (732) 826-8865; E-mail: englert.inc@prodigy.net; website: www.englertine.com. b. Petersen Aluminum Corporation, Tite-Loc Plus. Panels shall be 2" high, 12" wide, with mechanically seamed system. 1) Contact: 1005 Tonne Road, Elk Grove Village, IL 60007, (800) 722-2523; www.oac-clad.com. 2. Finish: Manufacturer's standard fluoropolymer 2-coat system with topcoat containing not less than 70 percent polyvinylidene fluoride resin by weight; complying with AAMA 2604. a. Color: Metallic Silver or Weathered Galvalume. SHEET METAL ROOFING, ALUMINUM (040) 07612 - 1 Replace Roof Savannas Preserve Stat Park Project 461007 2.2 ACCESSORIES A. Underlayment: Self -adhering, polyethylene -faced, polymer -modified, bituminous sheet ASTM D 1970; designed for installation under metal roofs, and high -temperatures. 1. Acceptable manufacturers: a. Grace: Ice and Water Shield — HT b. Polyglass: Polystick MTS Q. Tamko: �N eta an ile Underlayment :'>;ngl lvletalmat : T B. Slip Sheet: Rosin -sized building paper, 5 lb/100 sq. ft. (As Needed) C. Metal Accessories: The Contractor shall provide all materials required to complete a weather tight roofing system as per the construction documents, including: clips, fasteners, fleshings, penetration boots, ridge closure strips, roof vent, trim, copings, fascias, valley pans, rake closures, gutters, downspouts and louvers. All exposed accessories shall match the sheet metal roofing panels in finish and material type. 2.3 SUBSTITUTIONS A. By owner approval only. All material samples and submittals shall be made to the owner's representative and shall be pre -approved prior to installation. 2.4 FABRICATION � A. Fabricate sheet metal roofing to comply with details sho n et hda' s AC s "Architectural Sheet Metal Manual" that apply to the design, dimensions, metal, and other characteristics of installation indicated. Standing -Seam Roofing: Form standing -seam pans with finished seam height of 2" inches (or manufacturer's standard design). Structural standing seams shall be interlocking, with sealant applied at the panel interlock. 2.5 PERFORMANCE A. The roof system shall have Florida Product Approval for components and cladding or Miami - Dade Notice of Approval. B. The panels shall meet the requirements of ASTM E1592 for Wind Uplift Performance as required by Florida Building Code. C. Panels shall be tested in accordance with ASTM E-1646-95 standard test method for water penetration of metal roof panel system by uniform static air pressure difference. D. Air infiltration: No greater than 0.014 CFM/Ft2 at a test pressure of 1.57 PSF and 0.009 CFM/Ft2 at a test pressure of 6.24 PSF per ASTM E-283-73. SHEET METAL ROOFING, ALUMINUM (040) 07612 - 2 1 Replace Roof Savannas Preserve State Park Park Manager Residence Project #61007 Q. Panel shall display a flame spread classification of a Class I when tested in accordance with vvv ASTM E-84-87. G. Manufacturer's Warranty: Submit, for Owner's acceptance, manufacturer's standard warranty document executed by authorized company official. Manufacturer's warranty is in addition to, and not a limitation of, other rights Owner may have under contract documents. Provide warranties as follows: 1. Warranty covering the metal substrate against rupture, perforation and structural failure due to normal atmospheric corrosion. 2. Warranty on paint finish against cracking, peeling, blistering, chalk and color change. 3. Base Metal Warranty Period: 20 years beginning with date of substantial completion. 4. Finish Warranty Period: 20 years for Standard Colors. PART 3-EXECUTION 3.1 INSTALLATION A. General: Comply with the following: 1. SMACNA Architectural Sheet Metal Manual. 2. NRCA Roofing and Waterproofing Manual and Handbook of Accepted Roofing Knowledge. 3. Manufacturer's Construction Details Handbook. 4. AISC Steel Construction Manual. 5. AISI Cold Formed Steel Design Manual. B. Install tall underlayment on roof sheathing under sheet metal r le he i c n d b metal roofing manufacturer. EEE��� 1. Apply slip sheet over underlayment before installing metal roofing. C. Anchor roofing securely in place, with provisions for thermal and structural movement. Install with concealed fasteners unless otherwise indicated. D. Separate dissimilar metals with a bituminous coating or polymer -modified, bituminous sheet underlayment. E. Coat unpainted back side of aluminum roofing with bituminous coating where it will contact treated wood, ferrous metal, or cementitous construction. F. Install work with lines and corners of exposed units true and accurate. Form exposed faces flat and free of buckles, excessive waves, and avoidable tool marks, considering temper and reflectivity of metal. Provide uniform, neat seams with minimum exposure of solder, welds, and sealant. Fold back sheet metal to form a hem on concealed side of exposed edges unless otherwise indicated. 1. Install cleats to hold sheet metal panels in position. Attach each cleat with two fasteners to prevent rotation. 2. Screw, ( old stated nail), cleats not more than 12 inches o.c. Bend tabs over nails. SHEET METAL ROOFING, ALUMINUM (040) 07612 - 3 Replace Roof Savannas Preserve State Park Park Manager Residence Project461007 G. Seal joints as shown and as required for leak proof construction. Provide low -slope transverse seams using cleats where backup of moisture may occur. H. Make no face penetrations or perforations in metal panels by fasteners except as indicated or with specific approval by Architect. I. Install all panels continuous from ridge to eaves with no horizontal end laps. J. End lap all flashing and trim at least 3" (76 mm). K. Miter and solder all gutters and seal with a lining of ice and water shield membrane applied at the laps to provide watertight condition. I. Apply sealant at all butt joints. 2. Counter -flash or paint to match all soldered areas. L. Treat all valleys with a layer of ice and water shield spread out at least 24" (610 mm) each side from the center of the valley, on both sides, before applying valley flashing. M. End lap at least 6" (152 mm) at joints. N. Exercise care during installation to avoid damage or scratching of the panels. 1. Avoid walking on metal roof panels after installation is completed. END OF SECTION C 0 PY SHEET METAL ROOFING, ALUMINUM (040) 07612 - 4