HomeMy WebLinkAboutROOFING SUBMITTALDate: March 23rd, 2017
SCAN(YED
SY
St. 1 11" 10 r nlinh,
Roofing Submittal
Project Name: Savanna's Preserve State Park
S BY ED
St Lucie rolint,
WSE• PLANS AND ALL PROPOSED WORK
ARE SU31f:CT TO ANY CORaCTIONS
REOUIREII DY HUD IN,MfCTOi15 THAT
MAYBE NECESSARY IN ORDER TO
COMP6l WITH Ali, APPIJCADLE CODES,
9551 Gumbo Limbo Lane
Jensen Beach, FL 34957 ST. LUCIE COILNit1P
BLDG:j
DATE d
State of Florida Department
EC',
DATE:
Of Environmental Protection
,
PLUMl
3900 Commonwealth Boulevard, MS #520
DATE.
Tallahassee, FL 32399-3000
MECH
DATE:
I would like introduce our Team that will handle all Permitting/Inspections,
Field Operations, Billing, and Project Management/Submittals/Change
--
r ers or rs prolec .
Permitting/Inspections:
Jasmine Rivera
0-561-223-2096
F-561-444-2272
jrivera@thermasealroofs.com
COHOILRD FASTENERS OR ATTACHMENTS
ARE THE RESPONSISILay OF THE
CONTRACTOR OF RECORD
WJGP Structural Group, Inc.
Review of Shop Drawings or samples is only for conformance with
the design concept of.the project and does not relieve the Contractor
of, responsibility for any deviation from requirements of the Contract
Documents nor from responsibility for errors or omissions in the Shop
Drawings or Samples. Contractor shall determine and verify all field
measurements, field construction criteria,_ quantities, materials, catalog
numbers and similar dots, check and coordinate each Shop Drawing
and sample with the requirements of the work and of the
��Con//tract Documeenntts{,r�1�,,'
lJ�"Approved "` P"� I '0 f 0 Revise and resubmit
_`L_f Approved_ as noted ❑ No�t �¢r�oIv d�
Signature �� Date �7""i—'—'—
MaRn Office: 1421 Oglethoroe Rd. ' West Palm.BeSch, FL 33405 • Tel: 56t.223.2096 - Fax: 561.4}14.2272
License # CCC1328620
Solutions Driven and Customer Focused
Replace Roof Savannas Preserve State Park
Park Manager Residence
SECTION 07612 - SHEET METAL ROOFING, ALUMINUM (040)
PARTI-GENERAL
1.1 SECTION REQUIREMENTS
Project #61007
A. Submittals: A comprehensive package of product data, shop drawings, material samples, color
samples and any additional information required to fully describe the contractor's intent. Refer to
article 24 of the General Conditions.
B. Comply with SMACNA's "Architectural Sheet Metal Manual" unless otherwise indicated.
C. Roof system shall meet minimum wind uplift resistance as required by the Florida Building
Code.
D. Roof system shall have Florida Product Approval for components and cladding or Miami -Dade
Notice of Approval.
E. Quality Assurance: Installer Qualifications: Utilize an installer having demonstrated experience
on projects of similar size and complexity. yy��
PART 2 -PRODUCTS F I L t..t � !I PY
2.1 ROOFING SHEET METALS
A. Aluminum Sheet: Fabricated from aluminum sheet, ASTM B 209M for alclad Alloy 3105; 0.040
inch thick. (Panel size can be manufacturer's standard, guaranteeing that it meets wind uplift
criteria and resists oil -panning.)
Products (Basis of Design):
a. Englert Metal Roofing, Series S2500. Panels shall be 2" high, 12" wide, with
mechanically seamed system.
1) Contact: 1200 Amboy Avenue, Perth Amboy, NJ 08862; Telephone: (800)
610-1975, (732) 826-8614; Fax: (732) 826-8865; E-mail:
englert.inc@prodigy.net; website: www.englertine.com.
b. Petersen Aluminum Corporation, Tite-Loc Plus. Panels shall be 2" high, 12" wide,
with mechanically seamed system.
1) Contact: 1005 Tonne Road, Elk Grove Village, IL 60007, (800) 722-2523;
www.oac-clad.com.
2. Finish: Manufacturer's standard fluoropolymer 2-coat system with topcoat containing not
less than 70 percent polyvinylidene fluoride resin by weight; complying with AAMA 2604.
a. Color: Metallic Silver or Weathered Galvalume.
SHEET METAL ROOFING, ALUMINUM (040) 07612 - 1
Replace Roof Savannas Preserve Stat Park Project 461007
2.2 ACCESSORIES
A. Underlayment: Self -adhering, polyethylene -faced, polymer -modified, bituminous sheet
ASTM D 1970; designed for installation under metal roofs, and high -temperatures.
1. Acceptable manufacturers:
a. Grace: Ice and Water Shield — HT
b. Polyglass: Polystick MTS
Q. Tamko: �N eta an ile Underlayment
:'>;ngl lvletalmat : T
B. Slip Sheet: Rosin -sized building paper, 5 lb/100 sq. ft. (As Needed)
C. Metal Accessories: The Contractor shall provide all materials required to complete a weather
tight roofing system as per the construction documents, including: clips, fasteners, fleshings,
penetration boots, ridge closure strips, roof vent, trim, copings, fascias, valley pans, rake closures,
gutters, downspouts and louvers. All exposed accessories shall match the sheet metal roofing
panels in finish and material type.
2.3 SUBSTITUTIONS
A. By owner approval only. All material samples and submittals shall be made to the owner's
representative and shall be pre -approved prior to installation.
2.4 FABRICATION �
A. Fabricate sheet metal roofing to comply with details sho n et hda' s AC s
"Architectural Sheet Metal Manual" that apply to the design, dimensions, metal, and other
characteristics of installation indicated.
Standing -Seam Roofing: Form standing -seam pans with finished seam height of 2" inches
(or manufacturer's standard design). Structural standing seams shall be interlocking, with
sealant applied at the panel interlock.
2.5 PERFORMANCE
A. The roof system shall have Florida Product Approval for components and cladding or Miami -
Dade Notice of Approval.
B. The panels shall meet the requirements of ASTM E1592 for Wind Uplift Performance as required
by Florida Building Code.
C. Panels shall be tested in accordance with ASTM E-1646-95 standard test method for water
penetration of metal roof panel system by uniform static air pressure difference.
D. Air infiltration: No greater than 0.014 CFM/Ft2 at a test pressure of 1.57 PSF and 0.009 CFM/Ft2
at a test pressure of 6.24 PSF per ASTM E-283-73.
SHEET METAL ROOFING, ALUMINUM (040) 07612 - 2
1
Replace Roof Savannas Preserve State Park
Park Manager Residence
Project #61007
Q. Panel shall display a flame spread classification of a Class I when tested in accordance with
vvv ASTM E-84-87.
G. Manufacturer's Warranty: Submit, for Owner's acceptance, manufacturer's standard warranty
document executed by authorized company official. Manufacturer's warranty is in addition to,
and not a limitation of, other rights Owner may have under contract documents. Provide
warranties as follows:
1. Warranty covering the metal substrate against rupture, perforation and structural failure
due to normal atmospheric corrosion.
2. Warranty on paint finish against cracking, peeling, blistering, chalk and color change.
3. Base Metal Warranty Period: 20 years beginning with date of substantial completion.
4. Finish Warranty Period: 20 years for Standard Colors.
PART 3-EXECUTION
3.1 INSTALLATION
A. General: Comply with the following:
1. SMACNA Architectural Sheet Metal Manual.
2. NRCA Roofing and Waterproofing Manual and Handbook of Accepted Roofing
Knowledge.
3. Manufacturer's Construction Details Handbook.
4. AISC Steel Construction Manual.
5. AISI Cold Formed Steel Design Manual.
B. Install
tall underlayment on roof sheathing under sheet metal r le he i c n d
b metal roofing manufacturer. EEE���
1. Apply slip sheet over underlayment before installing metal roofing.
C. Anchor roofing securely in place, with provisions for thermal and structural movement. Install
with concealed fasteners unless otherwise indicated.
D. Separate dissimilar metals with a bituminous coating or polymer -modified, bituminous sheet
underlayment.
E. Coat unpainted back side of aluminum roofing with bituminous coating where it will contact
treated wood, ferrous metal, or cementitous construction.
F. Install work with lines and corners of exposed units true and accurate. Form exposed faces flat
and free of buckles, excessive waves, and avoidable tool marks, considering temper and
reflectivity of metal. Provide uniform, neat seams with minimum exposure of solder, welds, and
sealant. Fold back sheet metal to form a hem on concealed side of exposed edges unless otherwise
indicated.
1. Install cleats to hold sheet metal panels in position. Attach each cleat with two fasteners
to prevent rotation.
2. Screw, ( old stated nail), cleats not more than 12 inches o.c. Bend tabs over nails.
SHEET METAL ROOFING, ALUMINUM (040)
07612 - 3
Replace Roof Savannas Preserve State Park
Park Manager Residence
Project461007
G. Seal joints as shown and as required for leak proof construction. Provide low -slope transverse
seams using cleats where backup of moisture may occur.
H. Make no face penetrations or perforations in metal panels by fasteners except as indicated or with
specific approval by Architect.
I. Install all panels continuous from ridge to eaves with no horizontal end laps.
J. End lap all flashing and trim at least 3" (76 mm).
K. Miter and solder all gutters and seal with a lining of ice and water shield membrane applied at the
laps to provide watertight condition.
I. Apply sealant at all butt joints.
2. Counter -flash or paint to match all soldered areas.
L. Treat all valleys with a layer of ice and water shield spread out at least 24" (610 mm) each side
from the center of the valley, on both sides, before applying valley flashing.
M. End lap at least 6" (152 mm) at joints.
N. Exercise care during installation to avoid damage or scratching of the panels.
1. Avoid walking on metal roof panels after installation is completed.
END OF SECTION
C 0 PY