HomeMy WebLinkAboutPROJECT INFORMATIONBUILDING'S PEAK ROOF HEIGHT vs DESIGN WIND PRESSURE FOR COMPONENTS & CLADOW(PSF,) FOR ASCF 7 10 PEAK Rnt1F HFKY? fFCC Tueu nv Eo reJ To 60 FEET �r
BASIC WIND SPEED = 170 mph RISK CATEGORY II BUILDINGS _
RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RL7AIL, WHOLESALE)
PEAK
ROOF
L" LESS THAN 7'-9'
L" GREATER OR EQUAL THAN 7-9" AND
LESS THAN 12'-3'
L" GREATER OR EQUAL THAN 12'-3•
-
HEIGHT
POSITIVE
NEGADVE
POSITIVE
NEGATIVE
POSITIVE.
NEGA17VE
(h)
ULTIMATE
A.S.D.
ULTIMATE
A.S.D.
ULTIMATE
A.S.D.
UL RUATE
A.S.D.
ULTlNATf
A.S.D.
ULOMATf
A:SO.
D' - 15,
76.4
45.8
102.4
61.4
73.0
43.8
1 95.5
57.3
68.5
41.1
86.4
51.8
> 15'-20'
80.4
48.2
1076
_ 54.6
76.8
46.1 -
150.4
1 0.2
72.0
43.2
90.8
54.5
> 20'-25'
83.6
50.2
111.9
671
79.8
47,9
104.4
62.6
74.8
44.9
94.4
56.6
> 25'-30'
86.2
51.7
115.5
69.3
-82.4
49.4
107.7
64.6
77.3
46.4
974
38.4
> 3D'-40'
90.7
54.4
121.4
7P.8
86.6
52.0
113.3
68.0
81.2
48.7
102.4
61.4
> 40'-50'
94.3
56.6
126.2
75.7
90.0
54:0 .
117.7
70.6 -
84.4
50.6
106.5
63.9
> 50'-60'
973
58.4
130.3
78.2
92.9
55.7
121.5
72.9
87.2
52.3
109.9
65.9
BASIC WIND SPEED = 170 mph RISK CATEGORY 11 BUILDINGS i
RESIDENTIAL, APARTMENT BUILDINGS & COMMERCIAL BUILDINGS (RETAIL, WHOLESALE)
PEAK
ROOF
L" LESS THAN 12-3'
L" GREATER OR EQUAL THAN 1Z'-3-
HEIGHT
POSITIVE
NEGATIVE
POSINVE NEGATIVE
(h)
ULTIMATE
A.5
ULTIMATE
ULTIMATE
A.S.D. ULTIMATE
I A.S.D.
91:5
54.9
1677
00.6
84.3
50.6
148.4
189.0
93.6
.2
171.6
.0
86.2- --
51.7
151.9
-!91.1
> 60' - 96'
95.6 -
57.4
175.2
105.1
88.0
52.3
155.0
93.0
> 90' - Do'
97.3
58.4
178.4
107.4
89.7
53.8
1579
94.7
> 100' - 120'
700.5
60.3
184.2
110.5
92.5
55.5
163.0
978
> 120' - 140'
103.2
61.9
189.2
113.5
95.1
571
167.4
100.4
> 140' - 160'
105.6
63.4
193.6
116.2
973
58.4
171.3
102.8
160'-- 180'
107.8
64.7
197,6
118:6
99.3
59.6
1 774.9
104.9
> 180' - 200'
109.8
65.9
201.3
120.8
101.1
60.7
1 178.1
106.9
> 200' - 250'
1 44.1
68.5 1
209.2
125.5
105.2
63.1
1_ 185.1
111.1
> 250' - 300'
117.8
70.1.
216.0
129.6
108.5
65. 1
1 191.1
114.7
Mo.
121.0
72.6 -
221.9
133.1
- 111.5
66.9
L 196.3
717.E
> 350' - 400'
123.9
74.3
227.1
136.3
114. 1
68.5
F200.9
120.5
> 400' - 450'
126.4
75.8
2-11.8
139.1
116.5
69.9
205.1
123.1
> 450' - 500'
128.8
77.3
236.1
141.7 .
118.6
71.2
208.9
125.3
NO
1.) THIS CER77RED SIGNED AND SEALED WIND LOAD CHART, PREPARED BY THIS ENGINEER, BASED ON ASCE 7-,10, FOR A 84SIC WMD SPEED OF 170 MPI; AND
APPLICABLE RISK CATEGORY BUILDING & EXPOSURES IS COMPLETELY GENERIC AND DOES NOT PROVIDE INFORMATION FOR A SITE SPECIFIC PROJECT.
2.) THIS WIND LOAD CHART MUST BE SIGNED, SEALED AND DATED BY THIS ENGINEER /F USED TO OBTAIN A ONE TIME BUILDING PERMIF
J.) CONTRACTOR OR PERMIT HOLDER TO BE RESPONSIBLE FOR THE SELEC17ON OF DESIGN WIND PRESSURE BASED ON THIS GENERIC WIND LOAD CHART.
WIND PRESSURES ARE ULTIMATE AND AS.D. PRESSURES.
4.) THIS WIND LOAD CHART SHALL BE CONSIDERED INVALID /F ALTERED BY ANY MEANS.
5.) DESIGN WIND LOAD SELECTED BY THE CONTRACTOR OR PERMIT HOLDER FROM THIS W/ND LOAD CHART SHALL BE INDICATED ON A SEPARATE DOCUME14T PREPARED BY
THE CONTRACTOR OR PERMIT HOLDER (e.y., SPREADSHEET, OPENING SCHEDULE/TAKE OFF SHEET, ETC).
RECEIVED MAY 24 1017
FILE C®P
Ki
0l./iiNINtL)
BY
;t i
I11`ia (%r)1/nhT
INDICATED DESIGN WIND PRESSURES
CORRESPOND TO THE MAXIMUM END
ZONE AND INTERIOR ZONE COND/BONS
AND FOR ALL ROOF
SLOPES.
L = STORM PANEL LENGTH,
ACCORDION SHUTTER
BLADE LENGTH OR BAHAMA
SHUTTER HEIGHT.
** PRODUCTS WHICH BEAR A
M/AMI-OADE COUNTY OR A
STATE OF FLORIDA APPROVAL
a' �Q :'vGENF N.
No. 44167
'� -• STATE OF
Ais is Not A Master Drawing.
Valid Only For One Time Permgl
PEP0 `FS i
0EkG�j
2014 (5th EDITION) FLORIDA BUILDING CODE - BROWARD, PALM BEACH, MARTIN, ST. LUCIE & INDIAN RIVER COUNT
ASCE 7-10 / WIND PRESSURE CHART AS SHOWN
STORM PANELS ACCORDION & B4HM714 SHUTTERS xsx SCALE
RISK GAT If BLDGS 0611 V15
L E C O, N c. WIND PRESSURE CHART DATE
Jr TESTING R ENGINEERING COMPANY BASIC WIND SPEED = 170 mph
".. a4P. St. STe. 385, uweovu GeRGe7a; It mrm EXPOSURE D, Kd = 0.85 15- 188
Mane : (385)871-I538 . far : (J05)871-1531 DRAWING No
EB-0006719 m1T I m.x• 1 mar
WALTER A 77LLIT Jr. P.E. 1 au 11-1n '/N a
FLORIDA Lw. Q 44167 : a ♦ o>cNr¢x - /15 'r I - SHEET 1 OF 1