Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Page 1 of 2 File copy U6L INNEL) Mi7BY St. Lucie county rr, acts Ham. Log In User Registration Hot Topics Submit Surcharge Slats a Facts Publications FSC Staff BCIS Site Map Links search d bpr PubnAppr oval a UProdt SER: CONCEALED FASTENERS OR ATTACHMENTS Pmdvct Aoomvai Menu> Pretl,rR orAwiicnt'en5earch> An0cli len List I AppllcaHan Oatai, ARE THE RESPONSIBILITY OF THE FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code FL1D6'74-R12 CONTRACTOR CF RECORD vision 2014 Approved -Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. M wens orn(ag One en Horning Parkway Toledo, OH 43659 (740)404-7829 greg.keeler@owenscorning.com i HESE PLANS AND ALL PROPOSED WORK. ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MRI BE NECESOARY: C0aAiiN ORDER TO. mp*HL.hPPQCAUQkD s Greg Keeler greg.keeler@owenscorning.com ry4L{ U VJ �C{r Mel Sancrant ST Lei171E OUNT1r BUIT DP^'G TITVISIION 1 Owens Corning PKWY RMENN' ED FOR C ?,2LUNCE Toledo, OH 43659 rx� (419)376-8360 1cL1'{L1xrBy mel.sancrant@owenscornig.co[qa TE fi PLAINS 2LND PER:`IIT IMUST BE KEPT ON JOB OR INO LNSPECT!ON WILL BE MADE. Roorin Aspha t Shingles Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Robert J.M. Nieminen PE-59166 UL LLC 08/20/2017 John W. Knezevich, PE J Validation Checklist - Hardcopy Received FL10674 R12 COI 2016 01 COI Nieminen.ndf Standard ASTM D3161 ASTM D3462 ASTM D7158 Year 2009 2009 2008 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGFVXQwtDgtBNbEY5 V d/o2... 1/19/2017 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option 0 04/18/2016 04/19/2016 04/20/2016 06/08/2016 FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing Shingles and Starters 3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge Shingles Limits of Use Installation Instructions Approved for use in HVHZI No Approved for use outside HVHZ: Yes FL10674 R12 11 2016 04 FINAL ER OC ASPHALT SHINGLES FL10674-R12 odf Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE - 59166 Design Pressure: N/A Other: Refer to ER, Section S. Created by Independent Third Parry: Yes Evaluation Reports ELIQ674 R12 AE 2016 04 FINAL ER OC ASPHALT SHINGLES FL10674-R12 odf Created by Independent Third Party: Yes tack Nest Contact Us:: 2601 Blair Stone Road, M1 L 323Phone: 850-487-1824 The State of Florida Is an AA/EEO employer. Cpdvrieht 2007-1013 State of Florida, 1: Privaty Statement:: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mall to this entity. Instead, Confect the once by phone or by traditional mall. If you have any gmatlums, please contact 850.487.1395. -pursuant to Section 455.27S(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official Comm unhation with the licensee. However done It addresses are public means If you do not wish to supply a personal address, please provide the Department with an email address which Can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Pro duct Approval Ateepb. �14d Credit Card Safe http://www. floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQwtDgtBNbEY5 V b/D2... 1 / 19/2017 TRINITY ERD EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 EXTERIOR RESEARCH & DESIGN, I.I.C. Certif,cote of Authorization N9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 037940.02.12-R7 FL10674-R12,ssxma Date of Issuance:02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 51h Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert.I.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimHe seal appearing was authorleed by Robert Nieminen, P.E. on 0a/10/2016. This does not serve as an electronially signed document. Signed, sealed hardtop Rs have been transmitted to the product Approval Acre inistratcr and to the named die of CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the - -product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Prone Standard year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Entity Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC(TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/O1/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation, R2453 Exp. 08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic 0 d Supreme a fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire erg ass reinforced, 4-tab asphalt roof shingles. 4.1.3 Devonshire" are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration', TruDefinition' Duration*, Duration Premium Cool, Tru Definition Duration Designer Color Collection, TruDefiinition Oakridge, Oakridge and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge'" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory — - - for fire ratings of this product. Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R7 Certificate of Authorization p9903 FL10674-R32 Revision 7: 04/18/2016 Page 2 of 8 TRINITY ERE) 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Viand = 150 mph (Vera, = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vaad = 150 mph (Vent = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asohalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire shingles require minimum five (5) nails per shingle. ➢ WeatherGuarde HP shingles require minimum six (6) nails per shingle. ➢ Devonshire'" shingles require minimum six (6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing — Starter Strip Shingle and Starter Strip Plus: Fell underlaymem Deek SeBadhered Weatlledoani ry und¢daYment Drip— Drip edge edge -Nails located i-3"tram save Insist! first Sellualing adh¢me Starter 6trip0 ''... positioned along eau¢ shingletvach be removed Staner Strip shingle overhangs eavd and rakes il"4 Exterior Research and Design, LLC. certificate of Authorization 99503 Feeande4ayman Deck Shccdhe,ed _ W uh.flo k9 urdeda,roem fl, Drip edge Drip — edge Nag lorated hom gave Inners first Starter snip PWs S�ceng dhesiva ppdtanee ¢long ears Staner Step Pius overhangs eav s and raker 114 -314' Evaluation Report 037940.02.12-R7 F1.10674-1112 Revision 7: 04/18/2016 Page 3 of 8 6.2.6 Minimum Nailing —Classic 6. ANWICNA Nonnsl Mansard or Arne pare Wind Are.. High Wind desv.nes y Are. per. vi..t.. norm.les A... vi.nm. {uerte. Y• LAl f' �f' �' (B .Cx' f . tt• �L+_n• 7 Espo..1. Fxposici6n 2.7 Minimum Nailing— Berkshire®: aeahid Nip LA do desdlad. S Yi' I 9 Yt I 9 Vf I BYY 1" Y" Standard Fastening Pattern TRINITY ERD Normal Mon.ard or Are. per. Wind A,... High Wind desv.n.s y Are. p.ra vienros non,n.je. Area W..to. /uerte. f• z(AI f' a' z' (B z• Y• as uA 41 s s(8- Exposure Fxposicidn Seahniship Le tua de «lla&r VZA',hA roolmgcemenl Ccn.nto del«A•de at(aao Sealentstrip Ld fpa de 5llldll0l • 8 t4" 814. • • 8 u" 8 4" f 1.. Mansard or Steep Slope Fastening Pattern 6-Nail Fastening Pattern Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R7 Cert17imre ofAothorizotion 99503 F1.10674-1112 Revision 7: 04/18/2016 Page 4 of 8 Florida Building Code Online . . - lj la�a��� SCHIVI�tL l� BY Professionalt St. LucieCrntf.¢ ri>s3ctla BCIS Home I Log In I user Registration i Not Topics I Submit Surcharge j Stets AFaRs Publica[lons I FBC staff I BCI556e Map Search Or& ProductApproval USER: Public User Proaun Ao u-M Menu > Pma l + 5 > Aaolicatiom Iist> AppllwGon retail FL # FL-10450-R8 Application Type Revision Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technlcal.Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) 0 Tarto Roofing ne information Way Suite 225 Little Rock, AR 72202 (254) 913-7750 smohseen@tarcorooflng.com Sheik Mohseen smohseen@tarcoroofing.com Shaik Mohseen 2403 Taylors Valley Road Belton, TX 76513 (254) 913-7750 smohseen@tarcoroofing.com Sheik Mohseen 2403 Taylors Valley Road Belton, TX 78717 (254) 939-3775 Ext 210 smohseen@tarcoroofing.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 UL LLC 10/13/2017 John W. Knezevich, PE R Validation Checklist- Hardcopy Received FL10450 R8 COI 2016 01 COI Nieminen odf Standard Year ASTM D1970 2009 ASTM D226 2006 ASTM D3909 1997 ASTM D4869 2005 ASTM D6164 2005 ASTM D6380 2003 FM 4474 2004 http://www.floridabuiIding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqudsDrIH6I4890... 5/23/2017 Florida Building Code Online Page 2 of 2 FRSA/TRI April 2012 (04-12) TAS 103 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated Date Pending FBC Approval 04/25/2016 Date Approved 06/08/2016 Summary of Products 2012 1995 FL # Model, Number or Name Description 10450.1 Tarco Roof Underlayments Roof underlayments for use in prepared roof assemblies Limits of Use Installation Instructions --Approved -foruse in HVHZ:No — — -FL1045"S-Ir 20I6-04-FINAL ER-TARCUUNDERLAYMENTS-fLrO450= R8.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-217.5 Created by Independent Third Party: Yes Other: 1.) The design pressure herein Evaluation Reports pertains to one particular bonded FL10450 R8 AE 2016 04 FINAL ER TARCO UNDERLAYMENTS FL30450- R8.odf underlayment application for use beneath adhesive -set tile systems. Refer to ER Section Created by Independent Third Party: Yes 5.6.2 for details, and other bonded systems. 2.) Refer to ER uunderlayment Section 5 for Limits of Use. Back Neat C�tacUs:: 2§01 Blair Stone Road, Tallahassee R. 32399 Phone: 850.487-1824 The state of Flonds is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accesslbillte Statement :: Refund Statement Under Florida law, email addmsses are public records. Ifyou do not want your e-mail address released in response to a public -records request, do not send elecumnic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Honda Statutes, effective October 1, 2012, licensees Ilcensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The smalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® ® =13 - sccuritumtF.rstcs http://www.floridabuilding.orglprlpi_app_dtl.aspx?param=wGEVXQwtDqudsDrIH6I489O... 5/18/2017 1\ 'J TRINITY ERD EVALUATION REPORT Tarco Roofing One Information Way, Suite 225 Little Rock, AR 72202 EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Evaluation Report 10880.07_08-118 EL10450-RS Date of Issuance:07/11/2008 Revision 8: 04/28/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. —DESCRIPTIOii arco=Roof Uhderlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10 Prepared by: Robert J.M. Nieminen, P.E. as;.. �_! .`�r;� me dalmile seal appearing vas amhorleed by Robert Martinet, ', F'• P.E.onM/ie/2016. This does not serve as an electronlrally slgned Florida Registration No. 59166, Florida OCA ANE1983 t'••`,�SfNa�O:ck document. Signed, sealed hardooples have been transmitted to the ......P.... Product Approval Adminlstntor and to the named dlent CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. `J T RININ j ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Tarco, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pra a Standard Year 1504.3.1 Wind Uplift FM 4474 2004 1507.2.3, 1507.3.3, 1507.5.3, Physical Properties ASTM D226 2006 1507.7.3, 1507.8.3, 1507.9.3 1507.2.3, 1507.2.8, 1507.4.5.1, Physical Properties ASTM D4869 2005 1507.4.5.2, 1507.5.3, 1507.5.3.2, 1507.7.3, 1507.7.3.2, 1507.8.3, 1507.8.3.2, 1507.9.3, 1507.9.3.2- 1507.2.4, 1507.2.9.2, 1507.5.3, Physical Properties ASTM D1970 2009 1507.7.3 1507.2.9.2 Physical Properties ASTM D3909 1997 1507.2.9.2, 1507.3.3 Physical Properties ASTM D6380 2003 1507.3.3 Installation Practice FRSA/TRI April 2012 (04-12) 2012 1507.11.2 Physical Properties ASTM D6164 2005 1523.6.5.2.1 Physical Properties TAS 103 1995 3. REFERENCES: Enti Examination Reference Date ERD (TST6049) ASTM D6164 T6470.08.07-R1 08/30/2007 ERD (TST6049) FM 4474 T6460.06.07-R1 10/09/2007 ERD (TST6049) ASTM D1970 T30160.08.09 08/14/2009 ERD (TST6049) TAS 103 T33190.08.10 08/06/2010 ERD (TST6049) ASTM D1970 T32530.08.10 08/17/2010 ERD (TST6049) FM 4474 T37610.07.11 06/29/2011 ERD (TST6049) ASTM D3909 T40780.04.12 04/06/2012 ERD (TST6049) ASTM D6380 T40790.04.12 04/06/2012 ERD (TST6049) TAS 103 T35410.04.12 04/18/2012 ERD (TST6049) ASTM D1970 T45250.04.13-R2 04/23/2013 ERD (TST6049) Physical Properties T43930.09.13-R2 09/11/2013 ERD (TST6049) Physical Properties TAR-SC9480.15 07/02/2015 ERD (TST6049) Wind - FM4470/4474 TAR-SC5670.14 12/03/2015 ERD (TST6049) Wind - FM4470/4474 TAR-SC8020.14 12/03/2015 PRI(TST5878) ASTM D1970 BRY-018-02-01 08/11/2003 PRI(TSTS878) ASTM D1970 BRY-017-02-01 08/11/2003 PRI(TST5878) ASTM D226 TOT-014-02-02 05/18/2004 PRI(TST5878) ASTM D226 TOT-015-02-02 05/24/2004 PRI(TST5878) ASTM D6380 TOT-029-02-01 07/05/2005 PRI(TST5878) ASTM 04869 TOT-009-02-01 09/14/2004 PRI(TST5878) ASTM D4869 TOT-009-02-02 09/14/2004 PRI (TST5878) ASTM D226 TOT-041-02-01 05/24/2006 Miami-Dade(CER1592) FBC HVHZ Certification 12-0420.02 10/03/2013- Tarco Roofing Adhesive compound Affidavit 12/15/2015 UL, LLC. (QUA9625) Quality Assurance Service Confirmation Exp. 10/13/2017 Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-R8 Cediflcate ofAuthodration 09903 P FL10450-RS Revision 8: 04/18/2016 Page 2 of 10 4. 5. �l TRINITY ERD PRODUCT DESCRIPTION: 4.1 Self -Adhering Underlavments: LeakBarrier Fast90 Self -adhering Tile Underlayment is an asphalt -saturated organic felt coated on both sides with asphalt and surfaced on the top side with mineral granules and on the underside with a self - adhering compound and release film. LealCBarrief:-MS30O c—e a'nd Water Armor is a self -adhering, glass mat reinforced, mineral surfaced, SBS m�odi-ei—eiroof under al ymt. LeakBarrier PS200eT Ice and Water Armor is a self -adhering, glass mat reinforced, fabric surfaced, SBS modified roof underlayment. LeakBarrier P52001 a Ice and Water Armor is a self -adhering, glass mat reinforced, smooth poly film surfaced, SBS modified roof underlayment. LeakBarrier NR5004T is a self -adhering, plastic film surfaced, modified underlayment. LeakBarrier SS400 Ice and Water Armor is a self -adhering, fiberglass reinforced, smooth surfaced modified underlayment. 4.2- --Mechanically Fastened Underlavments: Tarco 15 is an ASTM D226 Type I, 15 lb asphalt -saturated organic felt Tarco 30 is an ASTM D226 Type II, 30 lb asphalt -saturated organic felt Tarco NO 30 is an ASTM D4869 Type II asphalt -saturated organic felt LeakBarrier EasyLay Is an asphalt -coated polyester fabric roof underlayment. 4.3 Mechanically Fastened and/or Bonded Underlavments: Fiberglass Mineral Surfaced Roll Roofing is an ASTM D3909, glass -fiber -reinforced, asphalt -coated, granule surfaced underlayment used as a valley liner. ASTM Organic Mineral Surface Tile Underlayment is an ASTM D6380, Class M asphalt -saturated organic roll roofing sheet. LeakBarrier EasyMopT" SBS is a polyester reinforced, SBS modified bitumen roofing underlayment. 4.4 Mechanically Fastened Base Sheets: LeakBarrier EasyLay UDL 35 consists of a woven -polymeric scrim with a textured fabric on the top surface. Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. LeakBarrier EasyLay UDL Basic consists of a woven -polymeric scrim with a textured fabric on the top surface. Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. LeakBarrier EasyLay UDL 50 consists of a woven -polymeric scrim with a non -woven fabric on the top surface and a rubberized polymeric coating on the back surface. Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity[ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-RB certificate OfAuthorization #9503 F1.10450-118 Revision 8: 04/18/2016 Page 3 of 10 'mil TRINITY ERD 5.4 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop Tarco underlayments are follows: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Nail -On Tile Foam -On Tile Metal Wood Shakes Slate Shingles & Shingles LeakBarrler Fast90 Yes Yes Yes No Yes Yes See 5.5.2 ea 8arrier,M-$3D0� Yes No No No Yes Yes LeakBarrler Yes Yes Yes Yes Yes Yes See 5.5.2 LeakBarrler PS200'u Yes No No Yes Yes Yes Yes LeakBarrler NR50o'a Yes No No (No copper or Yes Yes zinc) Leakearrier5S400 Yes No No No Yes Yes _ Yes Yes.- LeakearrierEasyLay Yes (as base sheet in (as base sheet in Yes Yes Yes multi -ply system) multi -ply system) Leak8arrier Easyl-ay Yes Yes Yes Yes Yes Yes UDL 15, UDL Basic or (see F1.16884) (as base sheet in (as base sheet In (See FL16884) (See FL36884) (bee FL36884) UDLSO multi -ply system) multi -ply system) Tarco 15 Yes No No Yes Yes No Yes Yes Tarco 30 Yes (as base sheet in (as base sheet in Yes Yes Yes multi -ply system) multi -ply system) Tarco NO 30 Yes No Na Yes Yes Yes (double layer) (double layer) (double layer) (double layer) Fiberglass Mineral Yes valley unerper No No No No No Surfaced Roll Roofing 1507.2.9.2(2) ASTM Organic Mineral Surface Tile Yes Yes No Yes Yes Underlayment 5eYes.z _17Yes Leak8arrier EasyMep Yes Yes Yes No Yes 5Bs see 5.5.2 5.5.1 Tarco 15, Tarco 30, Tarco NO 30 and EasyLay may be used as a mechanically attached base layer followed by a LeakBarrler self -adhering top layer or asphalt -applied ASTM Organic Mineral Surface Tile Underlayment or LeakBarrler EasyMop SBS with allowable roof covers noted above for the respective top layer underlayments. 5.5.2 "Foam -On Tile" is limited to use of 3M 2-Component Foam Roof Tile Adhesive AH-160 (FL6332) applications unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. Exterior Research and Design, U.C. Evaluation Report 10880.07.08-R8 certificate pfAathorizodan 49503 FL10450-RS Revision 8: 04/18/2016 Page 4 of 10 `-, I KINITY' ERD 5.6 Allowable Substrates: 5.6.1 LeakBarrier self -adhering direct -bond to deck: ➢ New untreated plywood (unprimed or primed with ASTM D41 primer); ➢ Existing plywood (unprimed or primed with ASTM D41 primer); ➢ New or existing OSB (unprimed or primed with ASTM D41 primer); ➢ Structural concrete (unprimed or primed with ASTM D41 primer). Note: Tarco does not require priming of new or existing plywood or OSB sheathing. New or existing plywood or OSB sheathing should be cleaned of all dirt and debris prior to application of LeakBarrier membranes. ASTM Organic Mineral Surface Tile Underlavment or LeakBarrier EasyMop SBS Direct -Bond to Deck: ➢ ASTM D41 primed structural concrete. Note: Refer to 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the overlying roof cover is foam -on tile roofing. 5.6.2 Bond to Mechanically Attached Base Sheet: LeakBarrier self -adhered to: ➢ ASTM-D226, Type or 11 felt;- ➢ ASTM D4869 felt; ➢ LeakBarrier EasyLay, LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50. ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS in hot asphalt to: ➢ ASTM D226, Type I or II felt; ➢ ASTM D4601, Type II base sheet. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12). 5.6.3 LeakBarrier Self -Adhering Bond to Other Substrate Types: ➢ ASTM D41 primed metal (flashing metal, valley metal, etc.) 5.6.4 Wind Resistance for Underlavment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 5.6.4.1 Maximum Design Pressure=-75.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ Primer: (Optional) ASTM D41 Base Ply: (Optional) LeakBarrier P5200Mu, self -adhered. Underlayment: LeakBarrier PS200n self -adhered. 5.6.4.2 Maximum Design Pressure = -120.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ Primer: (Optional) ASTM D41 Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200mU or LeakBarrier EasyBase, rolled Into place to create continuous bond Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier P5200n self -adhered. Exterior Research and Design, LLC. Evaluation Report 10880.07.08-RS Certificate of Authorization #9503 FL30450-RB Revision 8: 04/18/2016 Page 5 of 10 `, I KINIW ERD 5.6.4.3 Maximum Design Pressure=-217.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of AHJ. Primer: (Optional) ASTM D41 Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered Underlayment: LeakBarrier PS200Hr, self -adhered. 5.6.4.4 All other direct -deck, adhered Tarco underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. 5.6.4.5 Maximum Design Pressure =-45.0 psf': Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide rolls); See FBC FL16884. Fasteners: 12 ga. x 1.25-inch long x 3/8-Inch head diameter annular ring shank roofing nails and 1-5/8-Inch diameter tin caps Spacing: 6" o.c. at the 4-inch wide side laps and 8" o.c. at three (3) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS2O0mu, self -adhered Underlayment: LeakBarrier PS200Hr, self -adhered. 5.6.4.6 Maximum Design Pressure =-60.0 psf: - — - -Deck - - - Min. 19/32-inch-plywood to meet project requirements to satisfaction of AHJ. - - - Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin raps Spacing: 7" o.c. at the 4-inch wide side laps and 7" o.c. at three (3) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200Mu, self -adhered Underlayment: LeakBarrier PS200Hr, self -adhered. 5.6.4.7 Maximum Design Pressure =-60.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide rolls); See FBC FL16884. Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c. at the 4-inch wide side laps and 6" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS20On self -adhered. 5.6.4.8 Maximum Design Pressure =-82.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ. Base Sheet: LeakBarrier EasyLay Fasteners: Simplex MAXX Cap Fasteners Spacing: 8" o.c. at the 4-inch wide side laps and 8" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mo, self -adhered Underlayment: LeakBarrier PS200Hr, self -adhered. 5.6.4.9 Maximum Design Pressure=-120.0 psf Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of AHl. Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-inch long x 3/8-Inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 4" o.c. at the 4-inch wide side laps and 4" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS20OHr, self -adhered. Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-R8 Certificate ofAWhori+ation a9503 FL10450-R8 Revision 8: 04/18/2016 Page 6 of 10 C�INITY!ERD 5.6.4.10 For mechanically attached base sheet in a multi -ply system, the maximum design pressure for the selected assembly shall, at a minimum, meet or exceed the Zone 1 design pressure determined in accordance with FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are RAS 117, FM LPDS 1-29 and ANSI/SPRI WD3. Assemblies above marked with an asterisk` carry the limitations set forth in Section 2.2.1.5.1(a) of FM LPDS 1-29 for Zone 2/3 enhancements. 5.7 Exposure Limitations: LeakBarrier EasyLay, FAST 90, ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier EasyMop SBS shall not be left exposed for longer than 180-days after installation. LeakBarrier PS200RT shall not be left exposed for longer than 120-days after installation. LeakBarrier M5300, NR500"T, PS200' u or SS400 shall not be left exposed for longer than 30-days after installation. Tarco 15, Tarco 30 and Tarco NO 30 shall be covered as soon as possible after installation; exposure for more than 24 hours after installation could adversely affect performance. 6. INSTALLATION: 6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and primed the substrate (if applicable). 6.3 LeakBarrier® Fast90® Self -Adhering Tile Underlavment: 6.3.1 EasyLay shall be installed in compliance with the requirements for 90q felt underlayment (except the product is self -adhered) in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile Applications: Cut the Fast90 roll into 12' to 16' sections for workability and allow to relax prior to application. Chalk a plumb line 36" from all outside perimeters; then chalk plumb lines 32" apart, upslope to the ridge line. Membrane Application: ➢ Place a full width piece of Fast90 on the prepared substrate, parallel to the eave edge of the roof, with the selvedge edge positioned upslope and in -line with the 1" chalk line. ➢ Fold back half the sheet and remove the exposed release film, taking care not to displace the membrane ➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles and ridges, and repeat for the other half of the sheet. ➢ Remove selvage release film, if present, and install capped or tin tagged nails 6" c.c. in the center of the selvedge edge. ➢ Install the subsequent sheets in the same manner, with upslope selvedge edges in -line with chalk lines, with 4" side laps and 8" end laps. ➢ Seal all 8" end laps 1/16" thick application of asphalt plastic cement and stagger all end laps minimum 36". ➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave / rake areas to ensure a complete bond. 6.3.4 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Wait a minimum of 24 hours prior to loading roof tiles. Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-R8 Ce"Ificute ofAuthorization e9503 FL10450-RS Revision 8: 04/18/2016 Page 7 of 10 �l TRINITY: ERD All tiles shall be staged four tiles perpendicular to slope, six tiles on top, parallel to slope; not to exceed 10 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal batten. 6_4 _e_akBarrIer®',MS300PS200n', P5200mo. NR500"T or SS400 Ice and Water Armor: 6.4.1 - S 300, PS200"T P5200mu NR500"T or SS400 shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 Non -Tile Applications: Cut MS 300, PS200"T, PS200mu, NR500"T or SS400 to manageable sections and allow to relax prior to application. Membrane Application: ➢ Place a full width piece on the prepared substrate, aligned parallel to the eave edge and extend - approximately 3/8" over the eave and rake with the selvedge edge positioned upslope. ➢ Fold back the upslope half of the sheet and remove the exposed release film, taking care not to displace the membrane ➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles and ridges ➢ Apply a 1/16" thick layer of asphalt plastic cement over the eave and rake metal, extending 2" to 3" onto the deck surface. ➢ Fold back the downslope half of the sheet, remove the release film and roll the membrane onto the substrate from the centerline out. ➢ Seal all 6" end laps with a 1/16" thick application of asphalt plastic cement and stagger all end laps minimum 36". ➢ Remove selvage release film, if present, and install second and subsequent courses in a similar manner. ➢ Install capped or tin -tagged nails 6" o.c. along the centerline of the laps. ➢ At all T-joints, where an end -lap and the next overlapping course intersect, apply a bead of roofing laps cement before the overlapping course is laid. ➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave / rake areas to ensure a complete bond. 6.4.3 Tile Applications (PS200"T only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Wait a minimum of 24 hours prior to loading roof tiles. All tiles shall be staged four tiles perpendicular to slope, six tiles on top, parallel to slope; not to exceed 10 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal batten. Exterior Research and Design, L.L.C. Evaluation Report 10880.07.08-RS Certlffkate ofAuthorizatlon 09503 FL10450-RS Revision 8: 04/18/2016 Page 8 of 10 \INITY i ERD I TR 6.4.4 Multi -Ply Underlayment Systems: LeakBarrier® SS400 Ice and Water Armor followed by LeakBarrier® S5400 Ice and Water Armor (direct -to - deck per 5.6.1 or over mechanically attached base sheet per 5.6.2) is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a multi -ply underlayment system is desired. 6.5 Tarco 15 and 30: 6.5.1 Tarco 15 and 30 shall be installed in compliance with the requirements for ASTM D226, Type I and II underlayments, respectively, in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.5.2 Non -rile Applications: Reference is made to the current edition of the NRCA Steep -slope Roofing Manual. 6.5.3 Tile Applications, base laver in multi -ply system (Tarco 30 only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. 6.6 Tarco NO 30: 6.6.1 Tarco NO 30 shall be installed in compliance with the requirements for ASTM D4869, Type II underlayment _ —in FBC Sections 1507 for the type of prepared roof covering to be installed; 1507.4.5.2 (1), 1507.5.3.2 (1), 1507.7.3.2 (1), 1507.8.3.2 (1) or 1507.9.3.2 (1). 6_7 LeakBarrier EasyLay: 6.7.1 EasyLay shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.7.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application. 6.7.3 Non -Tile Applications: Place a full width section of EasyLay, parallel to the eave edge of the roof and unroll 2 to 3 feet with the lay lines facing up, and position to the edge of the eave and rake. Install a few fasteners at the top, near the rake, and roll out the sheet to a manageable length. Pull, straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the eave edge. Fasten with 3/8" headed roofing nails or 1" capped (plastic or metal) nails, driven by hand or pneumatically, spaced 6" o.c. at all laps in the center of the seam area, and two staggered rows fastened 12" o.c. in the field of the sheet. Install nails such that the head of the nail is flush with the surface, without cutting into the surface. Fasten from the top to avoid walking or kneeling on unsecured sheet. Continue to the end of the substrate and fasten down. Align the next roll over the preceding sheet so as to form a minimum 4", water -shedding lap, and install per instructions above. Apply subsequent sheets in the same manner, with minimum 4" water -shedding laps and minimum 8" end -laps, which are staggered minimum 36" fro the preceding course. For double layer applications, follow the instructions noted above, but using a minimum 19", water - shedding side lap. Allow for minimum 6" up the vertical transitions and minimum 6" over hips and ridges. At valleys, first install a vertical length of EasyLay down the center of the valley, then start at the low point and work to the high point, rolling the.membrane from the center outward in each direction, ensuring no wrinkles or tears. Covered with valley -metal or other valley lining material in accordance with NRCA recommendations. Apply a thin coat of asphalt plastic cement to waterproof areas where any cuts or tears have occurred. Seams or joints that require adhesive or sealant can be treated with high quality plastic cement (asbestos free). Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-R8 Certificate ofAathorhaNan C9903 FL10450-RB Revision 8: 04/18/2016 Page 9 of 10 . ,. \l TRINITY ERD 6.7.4 Tile Applications, base layer in multi -ply system: Reference,is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. 6.8 ASTM Oraanic Mineral Surface Tile Underlayment: 6.8.1 Shall be installed in compliance with the requirements for ASTM D6380, Class M sheets in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.8.2 Non -Tile Applications: Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for installing shingle underlayments and flashings. 6.8.3 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. 6.9 LeakBarrier'" EasyMop SBS: 6.9.1 Shall be installed in compliance with current Tarco published installation requirements, subject to the limitations herein. 6.9.2 Non -Tile Applications: For mechanically attached applications: Secure LeakBarrier EasyMop SBS using 3/8-inch headed roofing nails or 1-inch diameter cap -nails spaced 9-inch o.c. within the 4-inch wide side laps and 12-inch o.c. in two (2) equally spaced, staggered center rows in the center of the sheet. End -laps shall be minimum 6-inch wide, and offset end -laps minimum 3-feet from course to course. Seal end laps in accordance with Tarco requirements. For bonded applications: Fully adhere LeakBarrier EasyMop SBS in hot -asphalt to the substrates noted in Section 5.5. Side laps shall be minimum 4-inch and end -laps minimum 6-inch wide, and offset end -laps minimum 3-feet from course to course. Side and end -laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch beyond the lap edge. Consult Tarco instructions regarding back -nailing requirements. 6.9.3 Tile Applications: Refer to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. B. MANUFACTURING PLANTS: Contact the noted CIA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements 9. QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (847) 664-3281 END OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report 10880.07.08-118 Certificate of Authorization a9503 FL10450-RS Revision 8: 04/18/2016 Page 10 of 10 f A tloS-06A File Copy