HomeMy WebLinkAboutFEILD DENSITY REPORT, i" \ t 1J t.LuCie Conn1Y FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 9955 NW 116th Way, Suite 1 Miami, FL 33178 tel. 305-882-8200 • tax 305-882-1200 Permit No: Project No.: 3996000423 Client: Wawa Inc. Technician: Emmanuel Monuma I Project: Wawa Store # 5220 DATE: 3/27/2018 General Contractor: Hooks construction Grading Contractor: Mosley and son TEST PROCTOR LIFT WET DRY MOISTURE MOISTURE % OF •. ELEVATION BELOW DEPTH BELOW ' LOCATION GRID COORDINATES OR ROADWAY NO. No. NO. DENSITY DENSITY (PCF) % MAX DENSITY PASS FAIL RETEST FINISH PLAN STATION • (PCF) (PCF NO GRADE (FT.) SUBGRADE SPEC. ACTUAL 1 110.4 121.1 109.1 12.0 11.2 95.0 98.8 x 2'4" F4 B1 2 110.4 122.2 109.9 12.3 11.5 95.0 99.5 x 1'4" F4a B1 3 110.4 120.5 108.8 11.7 10.5 95.0 98.6 x 2'4" F6(a-A6 4 110.4 119.2 108.2 11.0 10.0 95.0 98.0 x 1'4" F6 A6 5 110.4 121.4 110.0 11.4 10.6 95.0 99.6 x 2'4" EZ@A7 6 110.4 120.8 109.2 11.6 10.8 95.0 98.9 x 1'4" F7no.A7 7 110.4 118.9 108.0 10.9 10.2 95.0 97.8 x 2'4" F6 A10 8 110.4 120.1 109.1 11.0 10.2 95.0 98.8 x 1'4" F6 A10 9 110.4 120.0 108.7 11.3 10.6 95.0 98.5 x 2'4" F6at7810 10 110.4 120.5 109.0 11.5 10.7 95.0 98.7 x 1'4" F6 810 Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Remarks: Above locations are compacted to firm conditions `Proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor Mod. Proctor Respectfully Submitted %E. Pa ATC G Seryic LLCYr Np p 23806 110.4 13.9 X�10ENSF lex E. ''��•nFs./ZORIDP.•\���!`i Senior Engineer =: MAR 2 8 RECD SjORAIEH�p,p License # 62519 ; Florida ? ' u still Density Repmt D'ccl 'mer-'!T ease tot results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only. The degree of compaction at greater depths in the fill an I at other locations as well as the condition of the underlying soils has not been determined by this office." U70 ac.BYNEL St. Luce C7110' FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 N1W 116th Way, Suite i Miami, FL 33178 tell. 305-882-8200 • fax 305-882-1200 Permit No: 1704-0135 Project No.: 3996000423 Client: Wawa Inc. Technician: Emmanuel Monuma Project: Wawa Store # 5220 DATE: 3/2712018 General Contractor: Hooks construction Grading Contractor: Mosley and son PROCTOR WET DRY % OF .. ELEVATION DEPTH TEST NO. LIFT DENSITY DENSITY MOISTURE MOISTURE MAX DENSITY PASS FAIL BELOW BELOW LOCATION GRID COORDINATES OR ROADWAY NO. NO. (PCF) RETEST FINISH PLAN STATION •(PCF) (PCF) NO GRADE FT.) SUBGRADE SPEC. ACTUAL 1 110.4 121.1 109.1 12.0 11.2 95.0 98.8 x 2'4" F4anB1 2 110.4 122.2 109.9 12.3 11.5 95.0 99.5 x 1'4" F4C_B1 3 110.4 120.5 108.8 11.7 10.5 95.0 98.6 x 2'4" F6 A6 4 110.4 119.2 108.2 11.0 10.0 95.0 98.0 x 1'4" F6 A6 5 110.4 121.4 110.0 11.4 10.6 95.0 99.6 x 2'4" F7na A7 6 110.4 120.8 109.2 11.6 10.8 95.0 98.9 x 1'4" F7na A7 7 110.4 118.9 108.0 10.9 10.2 95.0 97.8 x 2'4" F6 A10 8 110.4 120.1 109.1 11.0 10.2 95.0 98.8 x 1'4" F6 a@A10 9 110.4 120.0 108.7 11.3 10.6 95.0 98.5 x 2'4" F6 B10 10 110.4 120.5 109.0 11.5 10.7 95.0 98.7 x 1'4" F612B10 Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Remarks: Above locations are compacted to firm conditions 'Proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor Mod. Proctor Respectfully Submitted 23806 110.4 13.9 X c =_ ;. �tCENs'••.,G a 9'., STATEOF ' Alex' a i E. BIOP.. •Y`��e� 'pSN,"' o Florida License # 62519 '.n00+� Soil Density Report Disclaimer - "These test results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only. The degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." kTc FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 116th Way, Suite 1 Miami, FL 33178 tel. 305-882-8200 • fax 305-882-1200 Permit No: 1704-0135 Project No.: 3996000423 Client: Wawa Inc. Technician: Emmanuel Monuma Project: Wawa Store # 5220 DATE: 3/27/2018 General Contractor: Hooks construction Grading Contractor: UCMI PROCTOR WET DRY % OF .. ELEVATION DEPTH TEST NO. LIFT DENSITY DENSITY MOISTURE MOISTURE MAX DENSITY PASS FAIL RETEST BELOW BELOW LOCATION GRID COORDINATES OR ROADWAY NO. ' NO (PCF) (PCF) (PCF) % NO FINISH PLAN STATION SPEC. ACTUAL GRADE (FT.) SUBGRADE 11 110.4 119.5 109.0 10.5 9.9 95.0 98.7 x 2'4" F5x131a 813. 614 12 110.4 119.1 108.0 11.1 10.3 95.0 97.8 x 1'4" F5x131a B13. B14 13 110.4 119.6 108.7 10.9 10.1 95.0 98.5 x 2'4" F5x131a B13. B14 14 110.4 118.6 107.9 10.7 10.0 95.0 97.7 1 x 1'4" F5x13(a)B13, B14 15 110.4 119.9 108.6 11.3 10.6 95.0 98.4 x 6'6" FBx26 H14 G14 16 110.4 119.5 107.9 11.6 11.0 95.0 97.7 x 66" FBx26(a H14. G14 17 110.4 120.9 108.9 12.0 11.3 95.0 98.6 x 5'6" El x26lo�H14. (314 18 110.4 121.8 110.0 11.8 11.0 95.0 99.6 x 5'6" F8x26@H14, G14 19 110.4 121.1 109.7 11.4 10.5 95.0 99.4 x 6'6" P3 20 110.4 121.1 109.4 11.7 11.1 95.0 99.1 1 x 5'6" P3 Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfeot Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Remarks: Above locations are compacted to firm conditions `Proctor No. Maximum Density (PCF) Opt. Moisture (/o) u Std. . Proctor E. Mod. Proctor Respectfully SubmittedATC G p Se y ces LC,d {; 23806 110.4 13.9 X P:'`..jCE....... h% 625fy i - �.t•'•..,fjORIDP:'f11r+'t+++� At 1 a E. = Senior Engineer Florida License 9 62519 Soil Density Report Disclaimer -'These test results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only. The degree of compaction at greater depths in the fill and at other locations as well as the condition of the undedying soils has not been determined by this office." r- ;'ITC FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 116th Way, Suite 1 Miami, FL 33178 tel. 305-882-8200 • fax 305-682-1200 Permit No: 1704-0135 Project No.: 3996000423 Client: Wawa Inc. Technician: Emmanuel Monuma Project: Wawa Stare # 5220 DATE: 3/27/2018 General Contractor: Hooks Construction Grading Contractor: Mosley and son PROCTOR WET DRY % .. ELEVATION DEPTH TEST NO. LIFT DENSITY DENSITY MOISTURE MOISTURE MAX DENSITY PASS FAIL RETEST BELOW BELOW LOCATION GRID COORDINATES OR ROADWAY NO. • NO. (PCF) (PCF) (PCF) % NO FINISH PLAN STATION SPEC. ACTUAL GRADE (FT.) SUBGRADE 21 110.4 116.8 108.0 8.8 7.3 95.0 97.8 x 2'4" F59K15 22 110.4 117.3 108.8 8.5 7.9 95.0 98.6 x 1'4" F5na K15 23 110.4 117.1 108.1 9.0 0.2 95.0 97.9 x 2'4" F4 J14 24 110.4 117.0 107.9 9.1 8.7 95.0 97.7 x 1'4" F4@J14 25 110.4 116.6 108.6 8.0 7.2 95.0 98.4 x 7' F8x250)J12. J10 26 110.4 116.7 107.9 8.8 8.0 95.0 97.7 x 7' F8x25 J12 J10 27 110.4 115.1 108.9 6.2 5.9 95.0 98.6 x 6' F8x25(7D J12. J10 28 110.4 116.5 108.0 8.5 8.0 95.0 97.8 x 6' F8x25PJ12. J10 29 110.4 117.2 107.7 9.5 8.9 95.0 97.6 x 2'4" 1 F6x7@J7 30 110.4 118.3 108.4 9.9 9.0 95.0 98.2 x 1'4" F6x7na.J7 Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Remarks: Above locations are compacted to firm conditions 'Proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor n"""""'•., Mod. Proctor Respectfully Submitted g E. A ATC p Se LC,pz 23806 110.4 13.9 XP:•`�\GENSF>C3= * • p. STATE OF / Alex a i a E.Senior " �wFs.;20fltOp•'���'�.`� ineer Florida License # 62519-"'.y�ONA=ENG��,p` Soil Density Report Disclaimer -"These test results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only. The degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." ciTC FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 116th Way, Suite 1 Miami, FL 33178 tel. 305-882-8200 • fax 305-882-1200 Permit No: 1704-0135 Project No.: 3996000423 Client: Wawa Inc. Technician: Emmanuel Monuma Project: Wawa Store # 5220 DATE: 3/27/2018 General Contractor: Hooks construction Grading Contractor: Mosley and son PROCTOR WET DRY % OF .. ELEVATION DEPTH TEST NO. LIFT DENSITY DENSITY MOISTURE MOISTURE MAX DENSITY PASS FAIL BELOW BELOW LOCATION GRID COORDINATES OR ROADWAY NO. NO (PCF) (PCF) (PCF) RETEST NO FINISH PLAN STATION SPEC. ACTUAL GRADE (FT.) SUBGRADE 31 110.4 118.6 108.0 10.6 10.0 95.0 97.8 x 2-4" F7anJ5' 32 110.4 119.7 108.8 10.9 10.3 95.0 98.6 x 1-4" F7PJ5 33 110.4 118.4 108.1 10.3 9.7 95.0 97.9 x 5-4" FSla_J4 34 110.4 118.9 107.9 11.0 10.2 95.0 97.7 x 4-4" F8(aDJ4 35 110.4 119.3 108.6 10.7 10.1 95.0 98.4 x 54" FfIEDW 36 110.4 119.1 107.9 11.2 10.4 95.0 97.7 x 4-4" F8 J9ti 37 110.4 119.8 108.9 10.9 10.1 95.0 98.6 x 2-4" F6t7a.A5 38 110.4 118.5 108.0 10.5 9.8 95.0 97.8 x 1-4" F6QA5 Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Remarks: Above locations are compacted to firm conditions Proctor No. Maximum Density (PCF) Opt. Moisture (/o) u Std. Proctor Respectfully Submitted „.+."". Mad. Proctor �`' E. P44-1 ATC G rp Ser ice LC,,'" �Gs 23806 110.4 13.9 X r` P�'.......... .\C@NS STATE �� Q - 9'•5 OF Alex at E.F<pRIDP...\��'"r -'S��NAIENGio'o Florida License # 62519..unir Soil Density Report Disclaimer -"These test results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only. The degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." ' .LTG SCANNED BY St. Lucie Caunty I-7,,y- a137 FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 116th Way, Suite 1 Miami, FL 33178 tell. 305-882-8200 - fax 305-882-1200 Permit No: Project No.: 3996000423 Client: Wawa Inc. Technician: Emmanuel Monuma Project: Wawa Store # 5220 DATE: 4/4/2018 General Contractor: Hooks Construction Grading Contractor: Mosley and Son & UCMI PROCTOR WET DRY % OF . ELEVATION DEPTH TEST NO. LIFT DENSITY DENSITY MOISTURE MOISTURE MAX DENSITY PASS FAIL RETEST BELOW BELOW LOCATION GRID COORDINATES OR ROADWAY NO. NO (PCF) (PCF) (PCF) o/ NO FINISH PLAN STATION ' SPEC. ACTUAL GRADE (FT.) SUBGRADE 1 110.4 120.7 109.4 11.3 10.6 98.0 99.1 x 1' Building looter area: F8x22 @A1, 3 Building footer area: F6 @A5 Building looter area: F6 @A6 Building looter area: F7 @ A7 Building looter area: F6 @ B10 Building Tooter area: FBx26@FGH1 A6j§;15 rt � Building looter area: FBx25 @ Al, A 3 3 Storm line: St#1 / 15'W c " n :3, Storm line: St#1 / 2'N - , 2 110.4 120.1 109.9 10.2 9.7 98.0 99.5 x 1' 3 110.4 119.6 108.7 10.9 10.0 98.0 98.5 x 1' 4 110.4 120.9 110.6 10.3 9.4 98.0 100.21 x 1' 5 110.4 120.3 109.6 10.7 9.9 98.0 99.3 x 1' 6 110.4 119.1 108.9 10.2 9.5 98.0 98.6 x 1' 7 110.4 118.8 108.8 10.0 9.4 98.0 98.6 x 1' 8 110.4 121.0 110.0 11.0 10.3 98.0 99.6 x 2' 9 110.4 121.2 110.4 10.8 10.0 98.0 100.0 x 1' 10 f7 C7 Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum I Sheepsfoot Brickfoot rD -Ct - Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: e, Remarks: Above locations are compacted to firm conditions -n I � 'Proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor Mod. Proctor Rcspcctf�llySGbmi,gccl' , "" "••.. ATC,O cervices LUC,,''r�'f�W E. PANG+ 23806 110.4 13.9 X rp _ . � I d1 : "uCENSF 0 625t�` Q F7 - ' •-O ` STATE OF - F.Icxt a i e E.=9�.0'•:'`<Og10�.••'frp '.Sanior;Eugircer --'-.r�S%ONALENG;�i'� %Florida License M 625IS' n. Soil Density Report Disclaimer -'These test results should be regarded as indicators of the degree of compaction a0alned at these spot locations and depths only: Tha`degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." r ETC FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 116th Way, Suite 1 Miami, FL 33178 tell. 305-882-8200 • fax 305-882-1200 Permit No: Project No.: 3996000423 Client: Wawa Inc. Technician: Emmanuel Monuma Project: Wawa Store # 5220 DATE: 4/4/2018 General Contractor: Hooks Construction Grading Contractor: Mosley and son PROCTOR WET DRY % OF ** TEST LIFT MOISTURE MOISTURE BELOW BELOW LOCATION GRID COORDINATES OR ROADWAY NO. NO. NO DENSITY DENSITY (PCF) MAX DENSITY PASS FAIL RETEST FINISH PLAN STATION (PCF) (PCF) SPEC. acTua� NO GRADE (FT.) SUBGRADE 11 1 110.4 120.0 109.6 10.4 9.8 98.0 99.3 x 1' Building Tooter area: F6x7 P J7 12 110.4 120.2 110.1 10.1 9.3 98.0 99.7 x 1' Buildin Tooter area: F4 J14 13 110.4 120.2 109.9 10.3 9.5 98.0 99.5 x 1' Buildina footer area: F5(@K15 15 1 110.4 119.0 108.5 1 10.5 9.8 98.0 98.3 1 x 1' Building footer area:F4 J1 16 110.4 120.1 109.4 10.7 9.9 98.0 99.1 x 1' Building Tooter area: FS H4 17 110.4 119.8 108.8 11.0 10.3 98.0 98.6 x 1' Building Tooter area: F8 H9 18 110.4 120.1 109.3 10.8 10.0 98.0 99.0 x 1' Building footer area: F8x26 @FH1 19 110.4 121.7 110.5 11.2 10.5 98.0 100.1 x 1' Building footer area: F4 Q B1 I Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Maximum Density (PCF) Opt. Moisture (%) 110.4 13.9 Std. Proctor Mod. Proctor X EDF I Soil Density Report Disclaimer - "These test results should be regarded as indicators of the degree of compaction attained at these spot locations and'd@plhs only:' the tlegree of compaction at greater depths in the rill and at other locations as well as the condition of the underlying soils has not been determined by this office." , i ' ) r`\ 1 ETC FIELD DENSITY - NUCLEAR METHOD ATC Group Services LLC 9955 NW 118th Way, Suite 1 l Miami, FL 33178 ASTM D-6938 tel. 305-882-8200 • fax 305=8821.200�, Permit No: Project No.: 3996000423 "'"' Client: Wawa Inc. Technician: Emmanuel Monuma Project: Wawa Store # 5220 DATE: 4/5/2018 rr General Contractor: Hooks Construction Grading Contractor: Mosley and son y PROCTOR WET DRY % OF .,. ELEVATION DEPTH r-y ` TEST NO. LIFT DENSITY DENSITY MOISTURE MOISTURE MAX DENSITY PASS FAIL RETEST BELOW BELOW LOCATION GRID COORDINATES OR R � AY NO. NO (PCF) (PCF) (PCF) off, NO FINISH PLAN STATION SPEC. ACTUAL GRADE (FT.) SUBGRADE 1 110.4 120.2 108.2 12.0 11.4 98.0 98.0 x 1' Building footin 's iers: F8x26 @FGH14 2 110.4 121.2 109.5 11.7 11.0 98.0 99.2 x 1' Buildin footin 's iers: F8x26 G15 3 110.4 121.5 110.1 11.4 10.5 98.0 99.7 x 1' Building footin 's pkmLE4@114 4 110.4 121.5 110.6 10.9 9.0 x 1' Building footing's piers: F15 an K15 5 110.4 120.7 109.6 11.1 10.1 x 1' Buildingfootin 's iers: F8x25 J10 12 6 110.4 119.2 109.0 10.2 9.5 x 1' Buildingfootin 's piers: F8 G9 7 110.4 120.7 109.9 10.8 9.4 JOx x 1' Buildingfootin 's piers: F8 H4 8 110.4 120.0 110.0 10.0 9.3 x 1' Buildingfootin 's iers: F8x26 F1 H1 9 110.4 121.4 110.4 11.0 10.3 0 x 2' Buildingfootin 's : F6 A10 10 110.4 120.5 109.7 10.8 10.0 x 1' Building footin l F6 @ A10 Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: P Remarks: Above locations are compacted to firm conditions I 'Proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor Respectfull; Submitted �,q•""""•• Mod. Proctor ATC G Scr P JCE...... i 23806 110.4 13.9 X_, .r r: IV�o:625f�i i ' -O ` STATE OF Alex 't.�pR101 a It a s.....AlENG�a'+ ' Sc4iorBaginecr- "% ' Florida License 9 62519 Soil Density Report Disclaimer - "These test results should be regarded as indicators of the degree of compaction attained at these spot locations and'depths only. The degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." r' •Fg ETC FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 116th Way, Suite 1 Miami, FL 33178 tel. 305-882-8200 • fax 305-882-1200 Permit No: Project No.: 3996000427 Client: Wawa Inc. Technician: Emmanuel Monuma Project: Wawa Store # 5274 DATE: 04/20/2018 General Contractor: AT Construction Grading Contractor: BAC construction ELEVATION DEPTH NO. I NO. E LIFT WET DRY MOISTURE MOISTURE % OFF BELOW BELOW LOCATION GRID COORDINATES OR ROADWAY DENSITY DENSITY MAX DENSITY PASS FAIL RETEST NO. (PCF) % FINISH PLAN STATION (PCF) (PCF) ecr•r errnni NO GRADE (FT.) SUBGRADE `r faction Equipment Used: Vibratory: Non -Vibratory Rubber -tired Vibratory Plate X Walk Behind Steel Drum octor No. Maximum Density (PCF) Opt. Moisture (%) 23955 102.4 12.8% Smooth Steel Drum Sheepsfoot Other: Std. Proctor Mod. Proctor X "Floridn,L.Cccnsc,t(625l9 Soil Densitv Report Disclaimer -'These test results should be regarded as indicators of the deqree of compaction attained at these spot locations and depths a1ty. The decree of * ,* compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office. E�TG Permit No: Client: Wawa Inc. Project: Wawa Store # 5220 Contractor: Hooks Construction FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 116th Way, Suite 1 Miami, FL 33178 tel. 305-882-8200 • fax 305-882-1200 Project No.: 3996000423 Technician: Emmanuel Monuma DATE: 6/22/2018 Grading Contractor: Mosley and Son TEST PROCTOR LIFT WET DRY MOISTURE MOISTURE % OF MAX DENSITY PASS FAIL •f ELEVATION BELOW DEPTH BELOW LOCATION GRID COORDINATES OR ROADWAY NO. NO. NO. DENSITY DENSITY (PCF) RETEST FINISH PLAN STATION (PCF) (PCF) NO GRADE (FT.) SUBGRADE SPEC. ACTUAL 1 110.4 123.5 110.9 12.6 11.4 98.0 100.5 x Subgrade building sidewalk:Line K 1 5 2 110.4 117.3 109.1 8.3 7.6 98.0 98.8 x Subgrade buildin sidewalk:Line K 5 10 3 110.4 125.A 109.7 16.1 14.7 98.0 99.4 x Subgrade building sidewalk:Line K (10. 15) 1=1 4U11OD @i:)nl '4S 4U@W4Je as uI44!W-1ad N . )action Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Irks: Above locations are compacted to firm conditions proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor Mod. Proctor RcspcctfuIIy.Submi,tcd LLC 23806 110.4 13.9 X ATC C Gp Sorb+ ,O STA EOF Florida.Licensck 62519 Soil Density Report Disclaimer- "These test results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only.' The degree r compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this orrice." I 9�TC FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 11Sth Way, Suite (� Miami, FL 33178 tell. 305-882-8200 fax 30 jl�v12W Permit No: Project No.: 3996000423 m k(a toz n 0 Client: Wawa Inc. Technician: Emmanuel Monuma 0 CD Project: Wawa Store # 5220 DATE: 6/25/2018 :3 N rh. � ✓ rr General Contractor: Hooks construction Grading Contractor: Mosley and son -n PROCTOR WET DRY % OF .. ELEVATION BELOW DEPTH BELOW LOCATION GRID COORDINATES OR R WAY` TEST NO. LIFT DENSITY DENSITY MOISTURE MOISTURE MAX DENSITY PASS FAIL RETEST NO. NO (PCF) % FINISH PLAN STATION ' (PCF) (PCF) NO GRADE (FT.) SUBGRADE SPEC. ACTUAL 1 110.4 121.1 108.3 9.5 8.6 95.0 98.1 x Sub rade Sidewalk building pad north side: Line 15(K, H) 2 110.4 122.2 106.0 9.7 8.8 95.0 96.0 x Subgrade Sidewalk building pad north side: Line 15( H, D) 3 110.4 120.5 107.3 9.9 8.9 95.0 97.2 x Subgrade Sidewalk building pad north side: Line 15(D, A) 4 110.4 119.2 101.5 9.6 8.3 95.0 91.9 X Subgrade Sidewalk building pad north side: Line A(1, 5) 5 110.4 121.4 101.1 10.0 9.2 95.0 91.6 x Subgrade Sidewalk building pad north side: Line A( 5, 10) 6 110.4 120.8 101.4 10.4 9.6 95.0 91.8 x Sub rade Sidewalk building pad north side: Line A(10, 16) 7 110.4 118.9 102.0 10.1 9.4 95.0 92.4 x Subgrade Sidewalk building pad north side: Line 1(K, G) 8 110.4 120.1 101.9 10.3 9.5 95.0 92.3 X Subgrade Sidewalk building pad north side: Line 1(G, D) 9 110.4 120.0 102.1 10.5 9.7 95.0 92.5 x Subgrade Sidewalk building pad north side: Line 1(D, A) Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum I Sheepsfoot Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Remarks: More com action is required at above failed locations Proctor No. Maximum Density (PCF) p Opt. Moisture (/o) Std. Proctor Mod. Proctor Rcspcctfiilly Submitted „n"""""•.,,ATG G 5crvicc LLC,a"� S;E: PANi�C p i 23806 110.4 13.9 X - t 9`STATE OF fr % E. _�. FSenicir [ORIDP,.+`,r4�'6,, El1�nA' ' Florida License N 6251`I�'S�UNAI tf Soil Density Report Disclaimer -"These test results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only. The degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." , , c�TG FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services ILL rNt I 3. 9955 NW 116th Way, Sul eri Miami, FL 33178 C "t tel. 305-882-8200 • fax F5 @2-1200 Permit No: Project No.: 3996000423 O (D ro o_ Client: Wawa Inc. Technician: Emmanuel Monuma OD rt Project: Wawa Store # 5220 DATE: 4/8/2018 3 (D General Contractor: Hooks Construction Grading Contractor: UCMI r M- PROCTOR WET DRY % OFF ELEVATION DEPTH TEST NO. LIFT DENSITY DENSITY MOISTURE MOISTURE MAX DENSITY PASS FAIL RETEST BELOW BELOW LOCATION GRID COORDINATES OR ROADWAY NO. NO (PCF) (PCF) (PCF) NO FINISH PLAN STATION SPEC. ACTUAL GRADE (FT.) SUBGRADE 1 110.4 1 117.8 108.1 7.0 6.7 98.0 97.9 x 3' Electric wires: From Line K(2.3) to30'S 2 110.4 1 118.8 10B.2 7.7 7.0 98.0 98.0 x 2' Electric wires: From Line K(2. 3) to4O'S 3 110.4 1 118.9 109.7 7.2 6.8 98.0 99.4 x 1' Electric Wires: From Line K(2. 3) to25'S 4 110.4 1 119.0 109.0 10.0 9.5 98.0 98.7 x 4' Cleanout: From 1 O'N from Line A2 to 20'N 5 110.4 1 119.2 109.3 9.9 9.2 98.0 99.0 x 3' Cleanout: From 1 O'N from Line A2 to 1O'N 6 110.4 2 1 118.7 108.5 10.2 9.8 98.0 98.3 x 2' Cleanout: From 1 O'N from Line A2 to 25'N 7 110.4 2 119.8 110.0 9.8 9.9 98.0 99.6 x 1' Cleanout: From 1 O'N from Line A2 to 32'E 8 110.4 118.7 110.4 8.3 7.4 98.0 100.0 x Subgrade Building ad:Line 1 4 K E 9 110.4 118.1 109.7 8.4 7.7 98.0 99.4 Subgrade, Building Dad:Line (1.4)(E. A) 10 110.4 118.0 109.1 8.9 6.1 98.0 1 98.8 Subgrade Building ad:Line 4 7 K E E A Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum I Sheepsf001 Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Remarks: Above locations are compacted to firm conditions Proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor Mod. Proctor Respectfully Submitted ....... • P P n'" E. P4,, ATCO uu Scr'1eo LLC. 23806 110.4 13.9 X VCEN F 16 - -*: *y STATE OF "Alex 6,nior - .... s.NA...... Lice #6 519 ..n...rn Soil Density Report Disclaimer --These test results should be regarded as indicators of the degree of compaction attained at these spot locations and depots only.'The degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." ' I FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 116th Way, Suite Miami, FL 33178 tell.305-882-8200 • fax Permit No: Project No.: 3996000423 I ; ' (1)c Client: Wawa Inc. Technician: Emmanuel Monuma I r o0 Project: Wawa Store # 5220 DATE: 4/8/2018 General Contractor: Hooks Construction Grading Contractor: lD UCMI r TEST PROCTOR LIFT WET DRY MOISTURE MOISTURE % OF DENSITY �„ ELEVATION BELOW DEPTH BELOW LOCATION GRID COORDINATES OR ROADWAY NO. NO. NO DENSITY DENSITY (PCF) o/ MAx PASS FAIL RETEST FINISH PLAN STATION ' (PCF) (PCF) NO GRADE (FT.) SUBGRADE SPEC. ACTUAL 11 110.4 1 116.0 106.3 7.7 6.9 98.0 98.1 x Sub rade Building Dad:Line(T 10)(K.E) 12 110.4 1 115.0 108.2 7.1 6.3 98.0 98.0 x Sub rade Building Dad:Line(7, 10)(E. A) 13 110.4 1 116.2 109.0 7.2 6.8 98.0 98.7 x Sub rade Building ad:Line 10 13 KIL-,E 14 110.4 1 117.8 109.9 7.9 6.4 98.0 99.5 x Sub rade Building ad:Line 10 13 E A 15 110.4 1 117.3 109.3 8.0 7.2 98.0 99.0 x Sub rade Building ad:Line 13 15 K E 16 110.4 2 1 117.0 108.7 8.3 7.7 98.0 98.5 x Sub rade I Building ad:Line 13 15 E A I Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum I Sheepsfoot BJrickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: i Remarks: Above locations are compacted to firm conditions 'Proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor Mod. Proctor Respectfully Submitted „W,1111"1••• pTC G oL�sc Im LLC d`"r� E' PgNp P X ' VCENSE 23806 110.4 13.9 - ;,,c°............. �Na.625i�i i ' •O' # _ ' - STATE OF is -_O,�••.,!10RIDp.•�}4,`�c��� Alex a n,Y1E. Senior Engincer • Flo rida`L.conse R 62519 " Soil Density Report Disclaimer - "These test results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only. The degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." , c�TG FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC ce D 9965 NW 116th Way, Suite 3 Miami, FL 33178 tel. 305-882-8200 • fax 3 '-9 �63-12 ! Permit No: Project No.: d� 3996000423 Client: Wawa Inc. Technician: Emmanuel Monuma Project: Wawa Store # 5220 DATE: _o r 5/09/2018 General Contractor: Hooks construction r Grading Contractor: Mosley and Son/ Accent Electric TEST PROCTOR LIFT WET DRY MOISTURE MOISTURE % OF •• ELEVATION BELOW DEPTH BELOW LOCATION GRID COORDINATES OR ROADWAY" NO. NO. NO. DENSITY DENSITY (PCF) % MAX DENSITY PASS FAIL RETEST FINISH PLAN STATION (PCF) (PCF) NO GRADE (FT.) SUBGRADE SPEC. ACTUAL 1 110.4 120.1 110.0 10.1 9.7 98.0 99.6 X 1' AT&T wires: from Line 14(H.1, H) to 50'S 2 110.4 120.6 110.2 10.4 9.8 98.0 99.8 x 1' AT&T wires: from Line 14(H.1, H) to 100'S 3 110.4 119.8 109.9 9.9 8.7 98.0 99.5 X 1' AT&T wires: from Line 14(H.1, H) to 150'S 4 110.4 117.6 108.5 9.1 8.5 98.0 98.3 x 1' AT&T wires: from Line 14(H.1, H) to 200'S 5 110.4 118.7 109.0 9.7 9.0 98.0 98.7 x 1' AT&T wires: from Line 14(H.1, H) to 250'S 6 110.4 119.7 109.7 10.0 9.4 98.0 99.4 x 1' AT&T wires: from Line 14(H.1, H) to 300'S 7 110.4 118.1 108.9 9.2 8.6 98.0 98.6 x Subgrade Building slab tooter: Line 1 8 110.4 120.0 110.6 9.4 8.8 98.0 100.2 x Subgrade Building slab footer: Line A 9 110.4 120.1 109.8 10.3 9.7 98.0 99.5 1 x Subgrade Building slab tooter: Line 15 10 110.4 119.3 109.2 10.1 9.4 98.0 98.9 x Subgrade Building slab tooter: Line 1, 14 Compaction' Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum I Sheepsfoot Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Remarks: Above locations are compacted to firm conditions Proctor No. Maximum Density (PCF) Opt. Moisture ° (/o) Std. Proctor Mod. Proctor "••• Rcspcgtfully;Submittcd .....ATC•GSc LCp,""ts E. PANL� 23806 110.4 13.9% X ;,`+'`JCENSF CGS STgTE OF . Senior-Enginecnl '.•,,,,,,,m' - Florida Liccnse# 62519 • ' 1 Soil Density Report Disclaimer - "These test results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only. The degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office.' f FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC - 9955 NW 116th Way, Suite 'rr -t Miami, FL 33178'; tel. 305-882-8200 • fax 3 5- SF-1200 h C C • J hN I i Yt�_ � OR ROADWTV-- --"1 Permit No: Project No.: 3996000423 Client: Wawa Inc. Technician: Emmanuel Monuma Project: Wawa Store # 5220 DATE: 3/26/2018 General Contractor: Hook Construction Grading Contractor: Mosley And son TEST PROCTOR LIFT WET DRY MOISTURE MOISTURE % OF MAX DENSITY .. ELEVATION BELOW DEPTH BELOW LOCATION GRID COORDINATES NO. NO. NO. DENSITY DENSITY (PCF) % PASS FAIL RETEST FINISH PLAN STATION •(PCF) (PCF) NO GRADE (FT.) SUBGRADE SPEC. ACTUAL 1 110.4 112.6 108.9 9.3 8.5 95.0 98.6 x 2'4" F4 J1 2 110.4 112.7 110.2 10.1 9.3 95.0 99.8 x 1'4" F4na.J1 3 110.4 113.0 107.7 10.1 9.2 95.0 97.6 x 6'6" F8x26 �H1 4 110.4 113.6 107.9 9.8 9.4 95.0 97.7 x 6'6" FSx2fi E1 5 110.4 113.6 108.8 10.6 9.5 95.0 98.6 x 5'6" FSx26 H1 6 110.4 112.3 108.2 9.9 9.3 95.0 98.0 x 5'6" F8x26 an.E1 7 110.4 112.9 107.1 10.2 9.7 95.0 97.0 x 4' F8x22 Al 8 110.4 114.0 108.4 10.5 10.1 95.0 98.2 x 4' F8x22 A3 9 110.4 119.7 108.9 10.8 10.3 95.0 9B.6 x 3' F8x22 aC�A1 10 110.4 118.4 107.4 11.0 10.0 95.0 97.3 x 3' F8x22 �A3 Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Bfickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Remarks: Above locations are compacted to firm conditions i r *Proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor Mod. Proctor Res cctfull S fbmittcd """'•• P y ' "' Sc LL tS,E:... 23806 110.4 13.9 X - _ P .1 a' r''�CEIV. ; 3 f�o:625t� ; AEOF lex' E. = �.5�.'•�'20RIDt:•''4,rt - - -, corEn londaLiccnsc%1625i94 5 Soil Density Report Disclaimer- "These test results should be regarded as indicators of the degree of compaction attained at these spot locations and'depths only.- Thb degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office " E�TG FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 v ATC Group Services LLC r� N 9955 NW 116th Way, Suite Miami, FL 33178 C tel. 305-882-8200 • fax 30 �8: 1: LCl Permit No: Project No.: 3996000423 Or ,D Client: Wawa Inc. Technician: N Emmanuel Monuma 0) R T co H Project: Wawa Store # 5220 DATE: 3/27/2018 General Contractor: Hooks construction Grading Contractor: Mosley and Son Y r-r TEST PROCTOR LIFT WET DRY MOISTURE MOISTURE % OF .. ELEVATION BELOW DEPTH BELOW -'--'- LOCATION GRID COORDINATES OR ROADWAY NO. NO. NO DENSITY DENSITY (PCF) "� MAX DENSITY PASS FAIL RETEST FINISH PLAN STATION • (PCF) (PCF) NO GRADE (FT.) SUBGRADE SPEC. ACTUAL 1 110.4 119.5 109.0 10.5 9.9 95.0 98.7 x 2'4" F5x13 B13 2 110.4 119.1 108.0 11.1 10.3 95.0 97.8 x 1'4" F5x13 @ C14 3 110.4 119.6 108.7 10.9 10.1 95.0 98.5 x 214" F5x12@B13 4 110.4 118.6 107.9 10.7 10.0 95.0 97.7 x 1'4" F5x13 C14 5 110.4 119.9 108.6 11.3 10.6 95.0 98.4 x 6'6" F&WO H14 6 1 110.4 1 119.5 107.9 11.6 11.0 95.0 97.7 x 6'6" F8x26PG14 7 110.4 120.9 108.9 12.0 11.3 95.0 98.6 x 5'6" F8x26eH14 8 110.4 121.8 110.0 11.8 11.0 95.0 99.6 x 5'6" F80G14 9 110.4 121.1 109.7 11.4 10.5 95.0 99.4 x 6'6" P3 at H15 10 110.4 121.1 109.4 11.7 11.1 1 95.0 99.1 x 5'6" P3 at 1415 Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Bi ickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Remarks: Above locations are compacted to firm conditions ! *Proctor No. Maximum Density (PCF) Opt. Moisture (%) Sid. Proctor Mod. Proctor RcscoctfuHy Sebirittcd` ""�'•'•.. E. PS 23806 110.4 13.9 X ATC V- 6- ScCt'i , L'(-C,,'''dFi\S , *c�'. `,• -� ' ; 'J� ~r iWP-625f9�F i :9 �? �'Pc+FCeRID�:✓�4,`"c?�� • ;11cz a is a E. ' Scnid. Eoginccr i " � NALENG\''"� ,Florid3 Lice If62519�-.,n"'o vl . Soil Density Reoort Disclaimer - "These test results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only., The degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." ' FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC I 9955 NW 116th Way, Suit 11) -1 Miami, FL 33178 3 tel. 305-882-8200 - fax 3 9j8� -12g0 Cyr)', .� r) = c Permit No: Project No.: 3996000423 Client: Wawa Inc. Technician: Emmanuel Monuma c rD ry o Project: Wawa Store # 5220 DATE: 3/27/2018 0 rs General Contractor: Hooks construction Grading Contractor: Mosley and son TEST PROCTOR LIFT WET DRY MOISTURE MOISTURE % OF MAX DENSITY ** ELEVATION BELOW DEPTH' BELOW LOCATION GRID COORDINATES ADWAY---- NO. NO. NO DENSITY DENSITY (PCF) PASS FAIL RETEST FINISH PLAN STATION (PCF) (PCF) NO GRADE (FT.) SUBGRADE SPEC. ACTUAL 1 110.4 116.8 108.0 8.8 7.3 95.0 97.8 x T-0" F5 K15 2 110.4 117.3 108.8 8.5 7.9 95.0 98.6 x 6'-0" 5 3 110.4 117.1 108.1 9.0 8.2 95.0 97.9 x 4'-0" F4 J14 4 110.4 117.0 1D7.9 9.1 8.7 95.0 97.7 x 3'-0" F4anJ14 5 110.4 116.6 1D6.6 8.0 7.2 95.0 98.4 x 7' F8x25CrD112, J10 6 110.4 1 116.7 107.9 8.8 B.0 95.0 97.7 x 7' F8x25 J12 J10 7 110.4 115.1 108.9 6.2 5.9 95.0 98.6 x 6' F8x25@J12. J10 8 110.4 116.5 108.0 8.5 B.0 95.0 97.8 x 6' F8x25(rDJ12, J10 9 1 110.4 117.2 1 107.7 1 9.5 1 8.9 95.0 1 97.6 x 2'4" F6x7(a�J 7 10 1 110.4 118.3 1 108.4 9.9 9.0 95.0 1 98.2 x 1 1'4" F6x7 JI7 Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum I Sheepsfoot Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: 9i Remarks: Above locations are compacted to firm conditions *Proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor Mod. Proctor Rt; pPcctfully Submitted, ,,rr.."'.*• ., " E:'PAp� X AT(.'O p Ss a'LT Co''�yyS 23806 110.4 13.9 1 4lex a E.Ltenior O,p t'�(pR10t;,✓ .PP 'ro�ONACENv, ',,� Figi 7ndaLnc n cr#�6251' Soil Density Report Disclaimer - "These test results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only., The'degree,o compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." , . FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC f-r r 9956 NW 116th Way, Suite 1r- 3 Miami, FL 33178 n �: D' tell. 305-882-8200 • fax 3 SBBa-1208 I r -, , Permit No: Project No.: 3996000423 c Client: Wawa Inc. Technician: Emmanuel Monuma OD DATE: ri 3/27/2018 -r Project: Wawa Store # 5220 b r General Contractor: Hooks construction Grading Contractor: Mosley and on TEST PROCTOR LIFT WET DRY MOISTURE MOISTURE % OF MAX DENSITY FAIL .• ELEVATION BELOW DEPTH BELOW LOCATION GRID COORDINATES OR ROADWAY NO. NO. NO. DENSITY DENSITY (PCF) % PASS RETEST FINISH PLAN STATION (PCF) (PCF) NO GRADE (FT.) SUBGRADE SPEC. ACTUAL 1 110.4 118.6 108.0 10.6 10.0 95.0 1 97.8 x 2'4" F7@ 5 2 110.4 119.7 108.8 10.9 10.3 95.0 98.6 x 1'4" F7 J5 3 110.4 118.4 108.1 10.3 9.7 95.0 97.9 x 5'0" FS H4 4 110.4- 118.9 107.9 11.0 10.2 95.0 97.7 x 6'0" FS H4 5 110.4 119.3 108.6 10.7 10.1 95.0 98.4 x 5'0" FS H9 6 110.4 119.1 107.9 11.2 10.4 95.0 97.7 x 6'0" Fgna H9 7 110.4 119.8 108.9 10.9 10.1 95.0 98.6 x 2'4" F6 A5 6 110.4 118.5 108.0 10.5 9.8 95.0 97.8 x 1'4" F6@A5 I Bfickfoot Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: 11I Remarks: Above locations are compacted to firm conditions 9 i *Proctor No. Maximum Density (PCF) Opt. Moisture (%) Sid. Proctor Mod. Proctor A GSfuIIpyS ubmittc Lit r„00... E....% ..... 23806 110.4 13.9 X y `p`:• ' STATEOFt` Alcx a ' - a E. 'e �'2*','•..'2ORIDT;.+''��" ` 1'z S,y`......•."• . SenickEngincer .•' - 6� , ONAI EM ' e <,Florida, License.#b25 t9i,,' Soil Density Report Disclaimer - "These lest results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only.. The degree•of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." Tc FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 v ATC Group Services LLC P 9955 NW 116th Way, Suite G i=p Miami, FL 33178 r j tell. 305-882-8200 fax 305.-tb2-7:1200 Permit No: Project No.: 3996000423 -'- wex Client: Wawa Inc. Technician: t Emmanuel Monuma Project: Wawa Store # 5220 DATE: 3/28/2018 General Contractor: Hooks construction Grading Contractor: Mosley and son r' _ TEST PROCTOR LIFT WET DRY MOISTURE MOISTURE % OF DENSITY .� ELEVATION BELOW DEPTH BELOW LOCATION GRID COORDINATES OR ROADWAY NO. NO. NO DENSITY DENSITY (PCF) % MAX PASS FAIL RETEST FINISH PLAN STATION ' (PCF) (PCF) NO GRADE (FT.) SUBGRADE SPEC. ACTUAL 1 110.4 121.1 109.1 12.0 11.2 95.0 98.8 x 2'4" F4na,B1 2 110.4 122.2 109.9 12.3 11.5 95.0 99.5 x 1'4" F4na B1 3 110.4 120.5 108.8 11.7 10.5 95.0 98.6 x 2'4" F6 A6 4 110.4 119.2 108.2 11.0 10.0 95.0 98.0 x 1'4" F6 A6 5 110.4 121.4 110.0 11.4 10.6 95.0 99.6 x 2'4" F7 A7 6 110.4 120.8 109.2 11.6 10.8 95.0 98.9 x 1'4" F1@A7 7 110.4 118.9 108.0 10.9 10.2 95.0 97.8 x 24" EQ@A5 8 110.4 120.1 109.1 11.0 10.2 95.0 98.8 x 1'4" F6PA5 9 110.4 120.0 108.7 11.3 10.6 95.0 98.5 1 x 2'4" F6 B10 10 110.4 120.5 109.0 11.5 10.7 95.0 98.7 x 1'4" F6 B10 Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum I Sheepsfoot Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Remarks: Above locations are compacted to firm conditions 'Proctor No. Maximum Density (PCF) Opt. Moisture (% ) Std. Proctor Respectful[-. S ••. Mod. Proctor G p submitted pn..... ATCe. ;c, L¢,,'' ryes I. PAQ } : ''�\CENSF.,.G� 23806 110.4 13.9 X ;_, .i 6251Ii '_�.c�S; Alex a i a E.: ...... •;a�.i'�,p• Scrtior.-Frigijle 'Florida Liccnsc""# 62519' Soil Densitv Report Disclaimer - "These lest results should be regarded as indicators of the deqree of compaction attained at these spot locations and depths only: The degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." I. ,