Loading...
HomeMy WebLinkAboutEVALUATION REPORTJ UCEIV=D JUN 12 2017 `J TRINITY JERD EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 SCOPE: D6 - 02,45' ST. LUCIE COUNTY BUILDING DIVISION R£VI�6rlEO . FOR COE47PL1 REVIEWEP BY DATE f2 — — PLANS AND P RMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE OR RESEARCH & DESIGN, U.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 Report 037940.02.12-R7 SCANNEL► Date of IssuanceF02/06/2012 BY Revision 7: 04/18/2016 St. Lucie County This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality. Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity( ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the THESE PAS AND ALL PROPOSED WORK Official. This Evaluation Report consists of pages 1 through 8. ARE SUBJECT TO 9V COFFLRECTIONS Prepared by: ��qv�°ats" :�,'•,.. REQUIRED VY HELD INVE070415 THAT MAY BE NECES8AIRY IN ORDER TO r go-5?4 5 COMPLY Yin ALL APPLICABIgg 000E6, 4 jC[ Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 Thefacsimlie seal appearing was authorised by Robert Nleminen, P.E. on M/18/2016. This does not serve as an eleNomeally signed document. Signed, sealed hardmpies have been transmitted to the Product Approval Administrator and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. -Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the procitict. 5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD ROOFING SYSTEMS, EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: EftiLty. Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol.3 02/15/2007 UL LLC (CER9626) .Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various ULLLC (QUA9625) Quality Control Service Confirmation, R2453 Exp.08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Devonshire`" are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration, TruDefinition Duration', Duration Premium Cool, TruDefinition Duration Designer Color Collection, TruDefinitionOakridge, Oakridge and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4-.2 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard* HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge' Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, I.I.C. - Evaluation Report 037940.02.12-R7 Certglcare of Autholhado.#9503 - FL10674-R12 Revision 7: 04/18/2016 Page 2 of 8 ``I TRINITY kD 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Va,d =150 mph (Vast = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Va,d = 150 mph (Vast =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6_2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: ➢ Berkshire' shingles require minimum five (5) nails per shingle. ➢ WeatherGuard HP shingles require minimum six (6) nails per shingle. ➢ Devonshire'"' shinglesrequire minimum six (6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. -Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus: Felt undedaymmt SeWatlhered Weathedodca undedayment rakes K=YP Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R7 certficate o)Authartration OSM F1.10674-1112 1161slon 7:04/18/2016 Page 3 of 8 6.2.6 Minimum Nailing —Classic® & Supreme: Norrnaf Msneardsr 'Aron pars Wind Atesa, High ,Wind dssvenesIr Atospare vlenrosnsxmsler Amaa' vientssfusnsa aBspoaaio ,Ewposi43m 6.2.7 Minimum Nailing — Berkshire®: Standard Fastening Pattern Exterior Research and Design, I.I.C. Certll@ute ofAWhorizatlon a9503 Normal Mansard or Aree per4 VYIndAren High Wind tlesvanes y A46 pari blew" nonAras Arias vlantastuertes r .... � t. t.. z• z, r� r tzt .Erpoalelda b-Nall Fastening Pattern Evaluation Report 037940.02.12-117 FL10674-R32 Revision 7: 04/18/2016 Page 4 of 8 1 n 6.2.8 Minimum Nailing —Devonshire' : I U6lud6n del selladorI Standard 6-Nail Fastening Pattern `J I KINITY ERD Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing— Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition* Duration Designer Color Collection: Exterior Research and Design, U.C. CeN/lmte ofRuthor&ation #9503 Mansard or Steep Slope Fastening Pattern 6-Nail Fastening Pattern Evaluation Report 037940.02.12-R7 FL10674-R12' Revision 7: 04/18/2016 Page 5 of 8 6.2.1 Minimum Nailing — TruDefinition Oakridge®, Oakridge®: k400 Patfmn &4u0Ra.cgn4cizyos Standard Fastening Pattern -JTRINITYI ERD pahom E�ywraandasraen+>!R' §xposf9dn de66t8z Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing—WeatherGuard®HP: Fastening Pattern SlInYu iid. Ulwr I IF •• Lits�itN�l�lFdi Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R7 Certificate ofAuthoNzadon p9503 FL10674-R12 Revision 7: 04/18/2016 Page 6 of 8 9 a \ TRWITY, ERD 6.3 Hip & Ridge Shingles: 6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard* HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four (4) nails per shingle. Installation of DuraRidget Hip & Ridge Shingles shall comply with the manufacturers current published instructions, using two (2) nails per shingle. Refer to Owens Corning published information on wind resistance and installation limitations, including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturers published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge: 6.3.4 Minimum Nailing— WeatherGuard® HP Hip and Ridge: Exterior Research and Design, U.C. Certificate of Authorization #9503 Fig ClHlp A PlddeAliiggle Failaning; TOVVW 1 Nairn wu, r - - iiKse. Evaluation Report 037940.02.12-117 FL10674-R12 Revision 7: 04/18/2016 Page 7 of 8 6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles: ProvaRing Wind nireotion sedatstdp ,ate' 6• Exposure \I TPJNITYI ERD Standard Fastening Pattern »� I u• sealant T'k' 6' Expas 1 6.3.6 Minimum Nailing— DuraRidge" Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. van'vp'� 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 CIA requirements. 10. QUALITY AssURANCE ENTITY: UL LLC—QUA9625; (414) 248-6409; karen.buchmann@ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7 Certificate of Authorization #9503 FL10674-R12 Revision 7:04/18/2016 Page 8 of 8 0