HomeMy WebLinkAboutEVALUATION REPORTJ
UCEIV=D JUN 12 2017
`J TRINITY JERD
EVALUATION REPORT
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
SCOPE:
D6 - 02,45'
ST. LUCIE COUNTY
BUILDING DIVISION
R£VI�6rlEO .
FOR COE47PL1
REVIEWEP BY
DATE f2 — —
PLANS AND P RMIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
OR RESEARCH & DESIGN, U.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT #13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Report 037940.02.12-R7
SCANNEL► Date of IssuanceF02/06/2012
BY Revision 7: 04/18/2016
St. Lucie County
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality. Assurance documentation changes. TrinitylERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity( ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the THESE PAS AND ALL PROPOSED WORK Official.
This Evaluation Report consists of pages 1 through 8. ARE SUBJECT TO 9V COFFLRECTIONS
Prepared by: ��qv�°ats" :�,'•,.. REQUIRED VY HELD INVE070415 THAT
MAY BE NECES8AIRY IN ORDER TO
r go-5?4 5 COMPLY Yin ALL APPLICABIgg 000E6, 4
jC[
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
Thefacsimlie seal appearing was authorised by Robert Nleminen,
P.E. on M/18/2016. This does not serve as an eleNomeally signed
document. Signed, sealed hardmpies have been transmitted to the
Product Approval Administrator and to the named client
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. -Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
procitict.
5. This is a building code evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
CONCEALED FASTENERS OR ATTACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD
ROOFING SYSTEMS, EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2009
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2009
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2008
3. REFERENCES:
EftiLty.
Examination
Reference
Date
UL LLC (CER9626)
Physicals & Wind Resistance
File R2453, Vol.3
02/15/2007
UL LLC (CER9626)
.Physicals & Wind Resistance
20120516-R2453
05/16/2012
UL LLC (TST9628)
Physical Properties
06CA20263
04/18/2006
UL LLC (TST9628)
Wind Resistance
11CA34308
02/18/2012
UL LLC (TST9628)
Physicals & Wind Resistance
4786093137
02/01/2014
UL LLC (TST9628)
Wind Resistance
4786126532
02/10/2014
UL LLC (TST9628)
Physical Properties
Classification letter
02/13/2014
UL LLC (TST9628)
Physical Properties
Classification letter
10/02/2015
Miami -Dade (CER1592)
FBC HVHZ Compliance
Various NOAs
Various
ULLLC (QUA9625)
Quality Control
Service Confirmation, R2453
Exp.08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic and Supreme are fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles.
4.1.3 Devonshire`" are fiberglass reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration, TruDefinition Duration', Duration Premium Cool, TruDefinition Duration Designer Color
Collection, TruDefinitionOakridge, Oakridge and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4-.2 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard* HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidge' Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, I.I.C. - Evaluation Report 037940.02.12-R7
Certglcare of Autholhado.#9503 - FL10674-R12
Revision 7: 04/18/2016
Page 2 of 8
``I TRINITY kD
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Va,d =150 mph (Vast = 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified
in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are
acceptable for use in all wind zones up to Va,d = 150 mph (Vast =194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations. Contact
the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6_2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Berkshire' shingles require minimum five (5) nails per shingle.
➢ WeatherGuard HP shingles require minimum six (6) nails per shingle.
➢ Devonshire'"' shinglesrequire minimum six (6) nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
-Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus:
Felt undedaymmt
SeWatlhered
Weathedodca
undedayment
rakes K=YP
Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R7
certficate o)Authartration OSM F1.10674-1112
1161slon 7:04/18/2016
Page 3 of 8
6.2.6 Minimum Nailing —Classic® & Supreme:
Norrnaf Msneardsr 'Aron pars
Wind Atesa, High ,Wind dssvenesIr
Atospare vlenrosnsxmsler Amaa' vientssfusnsa
aBspoaaio
,Ewposi43m
6.2.7 Minimum Nailing — Berkshire®:
Standard Fastening Pattern
Exterior Research and Design, I.I.C.
Certll@ute ofAWhorizatlon a9503
Normal Mansard or Aree per4
VYIndAren High Wind tlesvanes y
A46 pari blew" nonAras Arias vlantastuertes
r .... � t. t.. z• z, r�
r tzt
.Erpoalelda
b-Nall Fastening Pattern
Evaluation Report 037940.02.12-117
FL10674-R32
Revision 7: 04/18/2016
Page 4 of 8
1
n
6.2.8 Minimum Nailing —Devonshire' :
I U6lud6n del selladorI
Standard 6-Nail Fastening Pattern
`J I KINITY ERD
Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing— Duration®, TruDefinition® Duration, Duration® Premium Cool & TruDefinition* Duration
Designer Color Collection:
Exterior Research and Design, U.C.
CeN/lmte ofRuthor&ation #9503
Mansard or Steep Slope Fastening Pattern
6-Nail Fastening Pattern
Evaluation Report 037940.02.12-R7
FL10674-R12'
Revision 7: 04/18/2016
Page 5 of 8
6.2.1 Minimum Nailing — TruDefinition Oakridge®, Oakridge®:
k400 Patfmn
&4u0Ra.cgn4cizyos
Standard Fastening Pattern
-JTRINITYI ERD
pahom
E�ywraandasraen+>!R' §xposf9dn de66t8z
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
Fastening Pattern
SlInYu iid. Ulwr
I IF
•• Lits�itN�l�lFdi
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R7
Certificate ofAuthoNzadon p9503 FL10674-R12
Revision 7: 04/18/2016
Page 6 of 8
9
a
\ TRWITY, ERD
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuard* HP Hip and Ridge Shingles and
ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four
(4) nails per shingle. Installation of DuraRidget Hip & Ridge Shingles shall comply with the manufacturers
current published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing for wind
warranties.
6.3.2 Fasteners shall be in accordance with the manufacturers published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge:
6.3.4 Minimum Nailing— WeatherGuard® HP Hip and Ridge:
Exterior Research and Design, U.C.
Certificate of Authorization #9503
Fig ClHlp A PlddeAliiggle Failaning;
TOVVW 1
Nairn wu,
r - -
iiKse.
Evaluation Report 037940.02.12-117
FL10674-R12
Revision 7: 04/18/2016
Page 7 of 8
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
ProvaRing
Wind nireotion sedatstdp
,ate' 6• Exposure
\I TPJNITYI ERD
Standard
Fastening
Pattern »� I
u• sealant
T'k' 6' Expas 1
6.3.6 Minimum Nailing— DuraRidge" Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
van'vp'�
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 CIA
requirements.
10. QUALITY AssURANCE ENTITY:
UL LLC—QUA9625; (414) 248-6409; karen.buchmann@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7
Certificate of Authorization #9503 FL10674-R12
Revision 7:04/18/2016
Page 8 of 8
0