Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online % �GANNEL, BY St Lucie rnf in+ Business &:Professional Regulation BCIS Home I Log In i User Registration : Hot Topics I Submit sumhaMe State & Facts . d90 . Product Approval b'r USER: Public User Product Aoomval Menu > Product or ly`1T ation Search > Aoolicatlon Lst> Application Detail FL # FL104S0-RB Application Type a lon Code Version 2014 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) -1 Tarco Roofing Page I of 2 File Copy II li€ - r Publications I FBC Staff I BC15 Site Map Links I Search One Information Way Suite 225 Little Rock, AR 72202 (254) 913-7750 smohseen@tarcoroofing.com Sheik Mohseen smohseen@ tarcoroofing. mm i:ONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF REOR➢ ) h- SE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE. NECESSSARY IN ORDEP TO +,0L9PL°,''vVITHk4L •PPLICALL CODES, Sheik Mohseen IG — 2403 Taylors Valley Road S I. IIC_TF C(1TJ>TY _ L,TJ^:C DMSIOV Belton, TX 76513 RE°. MNVED FOR (Z-A LL- NCE (254) 913-7750 f� smohseen@tarcoroofing.com tLEYi: �,`✓'� $b DATE Shack Mohseen PLAINS Aio`B EfiiiT MUST RE I{'r.:PT O1 JOL 2403 Taylors Valley Road OR NO INSPECTION WILL BE Ise 1,DE, Belton, TX 78717 (254) 939-3775 Ext 210 smohseen@tarcorooflng.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer n Evaluation Report - Hardcopy Received Robert Nieminen PE-59166 UL LLC 10/13/2017 John W. Knezevich, PE ',6 Validation Checklist - Hardcopy Received FL10450 R8 COI 2016 01 COI Nieminen df Standard Year ASTM D1970 2009 ASTM D226 2006 ASTM D3909 1997 ASTM D4869 2005 ASTM D6164 2005 ASTM D6380 2003 FM 4474 2004 http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDqudsDrIH6I489O... 5/ 18/2017 Florida Building Code Online Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code FRSA/TRI April 2012 (04-12) 2012 TAS 103 1995 Product Approval Method Method 1 Option D Date Submitted 04/18/2016 Date Validated Date Pending FBC Approval 04/25/2016 Date Approved 06/08/2016 Summary of Products r1 FL # Model, Number or Name Description 10450.1 Tarco Roof Underlayments Roof underlayments for use in prepared roof assemblies Limits of Use Installation Instructions Approved for use in HVHZ: No FL10450 R8 11 2016 04 FINAL ER TARCO UNDERLAYMENTS FL10450- R8.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-217.5 Created by Independent Third Party: Yes Other: 1.) The design pressure herein Evaluation Reports pertains to one particular banded FL10450 R8 AE 2016 04 FINAL ER TARCO UNDERLAYMENTS FLI0450- Rif underlayment application for use beneath adhesive -set the systems. Refer to ER Section Created by Independent Third Party: Yes 5.6.2 for details, and other bonded systems. 2.) Refer to ER Sunderlayment Section 5 for Limits of Use. Beck Next Cartnet Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an ANEW employer. Convrichi 1007-2013 State of Florida.:: Privacy statement:: Acceeslblfity Statement :: Refund Statement Under Florida law, email addresses ere public records. If you do not want your e-mail address released in response to a public -records request, do not and electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(i), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here-. Product Approval Accepts: ® ® P16 Credit Card Safe http://www. floridabuilding. org/pr/Pr_app_dtl.aspx?param=wGEV XQwtDqudsDrIH6I4890... 5/18/2017 1 I KINITYI ERD EVALUATION REPORT EXTERIOR RESEARCH & DESIGN, I.I.C. Cert0kate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 PHONE: (203) 262-9245 FAX: (203) 262-9243 t ua w nuunng Evaluation Report 10880.07.08-RS One Information Way, Suite 225 FL10450=R8' Little Rock, AR 72202 Date of Issuance: 07 11 200 SCOPE: Revision 8: 04/18/2016 This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the S1h Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: TaYCO ooft lnderla-yin LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the request of the Building Official. This Evaluation Report consists of pages 1 through 10. Prepared by: Robert J.M. Nleminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The faaimlie seal appearing was authorued by Robert Nleminen, P.E. an od/12/2016. This does not serve as an elemmnlally signed document Signed, sealed hardtopiss have been transmlled I the LERTIFICATION OF INDEPENDENCE 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nleminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. L I FTRINITYIERD 4. PRODUCT DESCRIPTION: 4.1 Self -Adhering Underlavments: LeakBarrier Fast90 Self -adhering Tile Underlayment is an asphalt -saturated organic felt coated on both sides with asphalt and surfaced on the top side with mineral granules and on the underside with a self - adhering compound and release film. eakBamier�MS300rlie and.Wkjr Armor is a self -adhering, glass mat reinforced, mineral surfaced, SBS o I led roof underlayment. LeakBarrier PS200"T Ice and Water Armor is a self -adhering, glass mat reinforced, fabric surfaced, SBS modified roof underlayment. LeakBarrier P5200P a Ice and Water Armor is a self -adhering, glass mat reinforced, smooth poly film surfaced, SBS modified roof underlayment. LeakBarrier NR500"T is a self -adhering, plastic film surfaced, modified underlayment. LeakBarrier SS400 Ice and Water Armor is a self -adhering, fiberglass reinforced, smooth surfaced modified underlayment. 4.2 Mechanically Fastened Underlavments• Tarco 15 is an ASTM D226 Type I, 15 lb asphalt -saturated organic felt Tarco 30 is an ASTM D226 Type II, 30 lb asphalt -saturated organic felt Tarco NO 30 is an ASTM D4869 Type II asphalt -saturated organic felt LeakBarrier EasyLay is an asphalt -coated polyester fabric roof underlayment. 4.3 Mechanically Fastened and/or Bonded Underlavments• Fiberglass Mineral Surfaced Roll Roofing is an ASTM D3909, glass -fiber -reinforced, asphalt -coated, granule surfaced underlayment used as a valley liner. ASTM Organic Mineral Surface Tile Underlayment is an ASTM D6380, Class M asphalt -saturated organic roll roofing sheet. LeakBarrier EasyMop'" SBS is a polyester reinforced, SBS modified bitumen roofing underlayment. 4.4 Mechanically Fastened Base Sheets: LeakBarrier EasyLay UDL 15 consists of a woven -polymeric scrim with a textured fabric on the top surface. Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. LeakBarrier EasyLay UDL Basic consists of a woven -polymeric scrim with a textured fabric on the top surface. Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See FBC File No. FL36884 use as a stand-alone roof underlayment. LeakBarrier EasyLay UDL 50 consists of a woven -polymeric scrim with a non -woven fabric on the top surface and a rubberized polymeric coating on the back surface. Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See FBC File No. FL36884 use as a stand-alone roof underlayment. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, U.C. certificate ofAuthori:ation #9503 Evaluation Report 10880.07.08-R8 FL10450-R8 Revision 8: 04/18/2016 Page 3 of 10 TRINITY r ERD 5.4 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable roof covers applied atop Tarco underlayments are follows: TABLE 1: ROOF COVER OPTIONS Asphalt Wood Shakes Underlayment Nail -On Tile Foam -On Tile Metal Slate Shingles & Shingles Leak8arrier Fast90 Yes Yes Yes No Yes Yes See 5.5.2 LeaC8arrler,,MS3d0= Yes Zf No No No Yes Yes LeakBarrier PS200"r Yes Yes Yes Yes Yes Yes See 5.5.2 LeakBarrier PS20ev Yes No No Yes Yes Yes Yes LeakBarrier NRS00"r Yes No No (No copper or Yes Yes zinc) LeakBarrier SS400 Yes No No No Yes Yes Yes Yes LeakBarrier EasyLay Yes (as base sheet in (as base sheet in Yes Yes Yes multi -ply system) multl-ply system) LeakBarrier EasyLay Yes Yes UDL 15, UDL Basic or Yes (as base sheet In (as base sheet in Yes Yes Yes UDL 50 (See FL16884) multi -ply system) multi -ply system) (See FL16884) (See FL16884) (See FL16884) Tarco 15 Yes No No Yes Yes No Yes Yes Tarco 30 Yes (as base sheet in (as base sheet in Yes Yes Yes multi -ply system) multi -ply system) Tarco NO 30 Yes No No Yes Yes Yes (double layer) I (double layer) (double layer) (double layer) Fiberglass Mineral Yes Surfaced Roll Roofing Valley Liner per No No No No No 1S07.2.9.2 (2) ASTM Organic Mineral Surface Tile Yes Yes Yes No Yes Yes Underlayment See s.5.2 LeakBarrier EasyMop Yes SBS Yes Yes See 5.5.2 No Yes Yes 5.5.1 Tarco 15, Tarco 30, Tarco NO 30 and EasyLay may be used as a mechanically attached base layer followed by a LeakBarrier self -adhering top layer or asphalt -applied ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS with allowable roof covers noted above for the respective top layer underlayments. 5.5.2 "Foam -On Tile" is limited to use of 3M 2-Component Foam Roof Tile Adhesive AH-160 (FL6332) applications unless tensile adhesion / long term aging data from an accredited testing laboratory is provided. Exterior Research and Design, LLC. Evaluation Report 10880.07.08-RB certificate of Authorization p9S03 FL10450-RS Revision 8: 04/18/2016 Page 4 of 10 �INITY- ERD All tiles shall be staged four tiles perpendicular to slope, six tiles on top, parallel to slope; not to exceed 10 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal batten. 6.4 'eakBafiie -O f 300-P.SZ00"T P5200N10 NR500"T or SS400 Ice and Water Armor: 6.4.1 MS 300, P52 0"'5200 P, NR500"T or SS400 shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections 1507 for the type of prepared roof covering to be installed. 6.4.2 Non -Tile Applications: Cut MS 300, PS200"T, PS200"', NR500"T or SS400 to manageable sections and allow to relax prior to application. Membrane Application: ➢ Place a full width piece on the prepared substrate, aligned parallel to the eave edge and extend approximately 3/8" over the eave and rake with the selvedge edge positioned upslope. ➢ Fold back the upslope half of the sheet and remove the exposed release film, taking care not to displace the membrane ➢ Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles and ridges ➢ Apply a 1/16" thick layer of asphalt plastic cement over the eave and rake metal, extending 2" to 3" onto the deck surface. ➢ Fold back the downslope half of the sheet, remove the release film and roll the membrane onto the substrate from the centerline out. ➢ Seal all 6" end laps with a 1/16" thick application of asphalt plastic cement and stagger all end laps minimum 36". ➢ Remove selvage release film, if present, and install second and subsequent courses in a similar manner. ➢ Install capped or tin -tagged nails 6" o.c. along the centerline of the laps. ➢ At all T-joints, where an end -lap and the next overlapping course intersect, apply a bead of roofing laps cement before the overlapping course is laid. ➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave / rake areas to ensure a complete bond. 6.4.3 Tile Applications (P5200"T onlv)• Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Wait a minimum of 24 hours prior to loading roof tiles. All tiles shall be staged four tiles perpendicular to slope, six tiles on top, parallel to slope; not to exceed 30 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. If tiles are to be left in a staged condition for more than 30 days, tiles shall be staged two tiles perpendicular to slope, four tiles on top, parallel to slope; not to exceed 6 tiles total to a maximum roof pitch of 5:12 for flat tiles and 6:12 for lugged tiles. At roof pitch in excess of those noted above, the tiles shall be staged behind a nominal 1 x 2 horizontal batten. Exterior Research and Design, U.C. Certificate oJAu[horka[fon A9503 Evaluation Report 10880.07.08-118 FL10450-R8 Revision 8: 04/18/2016 Page 8 of 10 Florida Building Code Online a. Page 1 of 2 File COPY SCANNED BY _ 2, dAliu— ��. LuCie (ni int. = . wmmlvw��� P rA 7 EMS Home Lag In User Registration Hot Topics Submit SurchaMe stats a Fans Publications HIC Staff aCtS Site Map Links Search b- Productdpr .=-1 Approval USER: Public User Prpauct PppmVdl Menu > Prool uct or�.a,�,g_L > Application 11, > Application Detail ""- FL # Fi.10674-R12 u - Application Type evfsf n Code Version 2014 Application Status Approved -Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived f"i Product Manufacturer §wens omrng Address/Phone/Email W ne O nMmin9 Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel Sancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofin Subcategory Asph 11. les Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer .7 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code Robert J.M. Nieminen PE-59166 ILL LLC 08/20/2017 John W. Knezevich, PE Validation Checklist - Hafdcopy Received EL10674 R12 COI 2016 01 COI Nlernmerif Standard ASTM D3161 ASTM D3462 ASTM D7158 Year 2009 2009 2008 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGFVXQwtDgtBNbFY5 V e/62... 1 /19/2017 Florida Building Code Online Page 2 of 2 Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 04/18/2016 04/19/2016 04/20/2016 06/08/2016 FL # Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge Shingles and Starters shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10674 R12 11 2016 04 FINA1, ER OC A PHA SHINGLES FL10674-R12.Ddf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert J. M. Nieminen PE - 59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section S. Evaluation Reports FL10674 R12 AC 2016 04 FINAL ER OC ASPHALT SHINGLES FL10674-R12 pdf Created by Independent Third Party: Yes Back Nezt tact U :: 2601 01air Stone Road Tallahassee FL 32399 Phone: 850-a9]-I814 The State of Florida Is an ANEEO employer. CeevrlaM1t 700]-2013 State of Floi da :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Flonds law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mail to this amity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. ¢Pursuant to Section 425.275(1), Florida Statutes, effenive Oclober 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The entails provided may be used for official communnaHon with the licensee. However email addresses are public record. It you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click li r[<. Product Approval Accepts: M m itr=i m Credit Card Safe http://www. floridabuilding. org/pr/pr_app_dtl.aspx?param=wGEV XQwtDgtBNbEY5 V D/D2... 1 / 19/2017 TRINITY ERD EVALUATION REPORT EXTERIOR RESEARCH & DESIGN, I.I.C. Certificate of Authorization N9503 353 CHRISTIAN STREET, UNIT 413 OXFORD, CT 06478 PHONE: (203)262-9245 FAX: (203) 262-9243 Owens Corning Evaluation Report 037940.02.12-R7 One Owens Corning Parkway FL10674-R32t- Toledo, OH 43659 Date of Issuance: 02/06/2012 Revision 7: 04/18/2016 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5`h Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinityl ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection atthejob site atthe request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was ..thorned by Robert Nleminen, P.E. on a1/18/2016. This does not serve as an electonipally signed document Signed, sealed hardampks have been taanamltted to the Product Approval Adm inlaustor and to the named client CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2009 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2008 3. REFERENCES: Entity Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-112453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami-Dade(CER1592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation, R2453 Exp. 08/20/2017 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic fiberglass reinforced, 3-tab asphalt roof shingles. =erg 4.1.2 Berkshireeinforced, 4-tab asphalt roof shingles. 4.1.3 Devonshire`" are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration*, Tru Definition Duration, Duration' Premium Cool, Tru Definition Duration' Designer Color Collection, TruDefinition'Oakridge, Oakridge' and WeatherGuard' HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard' HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidge" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in the HVHZ. 5.3 Fire: Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R7 CenTicete ofAothoriaotion 09503 FL10674-R12 Revision 7: 04/18/2016 Page 2 of 8 TRINITY ERD 5.4 Wind Classification: 5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to V,,d = 150 mph (V„ It = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to V,,d = 150 mph (Vu, = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building Code and F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Asphalt Shingles: 6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following exceptions: D Berkshire shingles require minimum five (5) nails per shingle. ➢ WeatherGuard HP shingles require minimum six (6) nails per shingle. ➢ Devonshire'm shingles require minimum six (6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. 6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. See figures below for details. 6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus: reh undetlaymem Dta sdr<dht,td W 4a9 - under4tbyhtmem i on, ee6< Dap- edge Neb looted 27-3-hom eav4 S N. 9i,to dMsiva Int jrm Stoner SItti poudaned clang etke Stener SW Plus ovvit.,t a vo.nd mkt, t/4'-3/4- Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R7 Cenificare ofAulthori3otion 99S03 FL10674-R12 Revision 7:04/18/2016 Page 3 of 8 6.2.6 Minimum Nailing — Classic &Su came: Nortnal Mansard or Are, pare Wind Areae High Wind dervenar x Area par, vfanto, normefea Area• vienta, ruertea 11' 1 P 5'Eapo,ura Erpoaicidn 6.2.7 Minimum Nailing — Berkshire®: Sealant strip La iga de eo0eda- e Y'i I 9 Yf I 9 Yf 1" Standard Fastening Pattern TRINITY ERE) Normal Man,ard or Area Para Wind Aree, High Wind de,venee 11 Area Para vienrae normafe, Area• vientoa fee".. txt t21 5 5i8' Exposure Erpa,icidn Sealant strip La lin de sell dor _ 8 4a" 1 8 th' 1 B W. r \ 6-Nail Fastening Pattern Sealant Strip 1Lae it-ade ludo, I8 4f � B Yf I 8 Yf t Ay -hag roofing cement LeWnt• de tech. de asfata Mansard or Steep Slope Fastening Pattern Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7 CenWcate of Authorization 99503 FL10674-R32 Revision 7: 04/18/2016 Page 4 of 8