HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Pagel of 3
•.R r t r�;. ,�„tr
x r
5 n'7
A � 6
M
x SCIS Home Login I User Reg@traton Hot Tool. Submit Sur,haMeState &Faar Publimtions MC Staff MIS Site Map i.. [Inks I Seard,
9onda
-pr 3(r Product Approval
USER: PUser
Pmdud Approval Menu> ProaaR or Aoof cion SeartM1> Anolimtlnn List>
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed the
Evaluadon Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
SCANNED
FL12765-R4 BY
Affirmation 1
2014 St. Lucie County
Approved
r
]anus International Corporation
134 East Luke Road
Temple, GA 30179
(770) 562-2850 Ext 360
carts@janusintl.com
Curtis Schroeder
torts@janusintl.com
Curtis L. Schroeder
134 Janus International Blvd.
Temple, GA 30179
(770) 562-2850 Ext 360
curls@janusinti.com
Jake Lyons
134 ]anus International Blvd.
Temple, GA 30179
(770) 562-2650 Ext 304
jakel@janusintl.com
Exterior Doors
Roll -Up Exterior Door Assemblies
Evaluation Report from a Florida Registered Architect or a
Licensed Florida Professional Engineer
ZI Evaluation Report - Hardcopy Received
Joseph H. Dixon, Jr
PE-7768
National Accreditation and Management Institute
12/31/2018
Gordon Thomas, P.E.
❑ Validation Checklist - Hardcopy Received
FL12765 R4 COI 29018 Cert of 8. indeo.udf
Referenced Standard and Year (of Standard) Standard year
ANSI/DASMA 108 2005
ASTM E330 - 2002
TAS 201 1994
TAS 202 1994
TAS 203 1994
Equivalence of Product Standards
Certified By
http://www.floridabuilding.org/pr/Pt app_dtl.aspx?param=wGEVXQwtDgsmFBeODh9XI... 9/20/2016
Florida Building Code Online
Page 2 of 3
C
Sections from the Code
WRI affirm that there are no changes in the new Florida
Building Code which affect my product(s) and my product(s)
are in compliance with the new Florida Building Code.
Documentation from approved Evaluation or Validation Entity OYes ONo ON/A
FL32765 R4 CDC 35008 self affirm 12765 R3.adf
Product Approval Method Method 1 Option D
Date Submitted 03/10/2015
Date Validated 03/10/2015
Date Pending FBC Approval
Date Approved 03/15/2015
Summary of Products
FL #
Model, Number or Name
Description
12765.1
Series 1100
Series 1100 - 26 Gauge Door Assebmly Max Size: 8'-B" x
14'-0"
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12765 R4 If 29018 Dwe T1012 Rev A.udf
Approved for use outside HVHZ: Yes
FL12765 R4 II 290tS install 750 1300.odf
Impact Resistant: No
Verified By: Joseph H. Dixon, Jr. 7768
Design Pressure: +24.4/-27
Created by Independent Third Party: No
Other: Not for use in High Velocity Hurricane Zones
Evaluation Reports
FL12765 R4 AE ER-09-00088RR gdf
Created by Independent Third Party: Yes
12765.2
Series 1100
Series 1100 - 26 Gauge Door Assembly Max Size: 10'-0" x
14'-0'
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12765 R4 JI 29018 Own T1013 Rev A.odf
Approved for use outside HVHZ: Yes
FL12765 R4 II 29016'nstoIL750 110-0.pdf
Impact Resistant: No
Verified By: Joseph H. Dixon, Jr. 7768
Design Pressure: +19.4/-22.7
Created by Independent Third Party: No
Other: Not for use In High Velocity Hurricane Zones
Evaluation Reports
FL12765 R4 AE ER-09-0008-R.odf
Created by Independent Third Party: Yes
765.3
Series 3100
Series 3100 - 26 Gauge Door Assembly Max Size: 16'-0" x
20'-0"
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12765 R4 11 34012 Dwo T1004 E.odf
Approved for use outside HVHZ: Yes
FL32765 R-4 II 34022 Mod 3100 lost instr.odf
Impact Resistant: No
Verified By: Joseph H. Dixon, Jr. 7768
Design Pressure: +36/-41
Created by Independent Third Party: No
Other: +36/-41 psf at 12'-0" wide. Varying loads are
Evaluation Reports
shown for widths 8'-0" to 16'-0". Not for use in High Velocity
FL12765 R4 AE M3100 FL12765 TIOOSG P2.odf
Created by Independent Third Party: Yes
Hurricane Zones
12765.4
Series 3100
Series 3100 - 26 Gauge Door Assembly Max Size: 20'-0" x
20'-0"
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12765 R4 If 32041 FL T1005-F 0002.pdf
Approved for use outside HVHZ: Yes
FL12765 R4 11 34022 Mod 3100 Inst instr.pdf
Impact Resistant: No
Verified By: Joseph H. Dixon, Jr. 7768
Design Pressure: +35/-38
Created by Independent Third Party: No
Other: +35/-38 psf at 16'-0" wide. Varying loads are
Evaluation Reports
shown for widths 15'-0" to 20'-0". Not for use In High
07 R2 120112 0
Created by Independent Third Party: Yes
Velocity Hurricane Zones
12765.5
Series 750
Series 750 — 26 Gauge Door Assembly Max Size: 3'-0" x
12'-0"
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12765 R4 lI 29018 Own T1000 Rev B.odf
Approved for use outside HVHZ: Yes
FL12765 R4 11 29018 Install 750 1100.odf
Impact Resistant: No
Verified By: Joseph H. Dixon, Jr. 7768
Design Pressure: +35/-45
Created by Independent Third Party: No
Other: Not for use in High Velocity Hurricane Zones
Evaluation Reports
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsmFBeODh9XI... 9/20/2016