Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online Pagel of 3 •.R r t r�;. ,�„tr x r 5 n'7 A � 6 M x SCIS Home Login I User Reg@traton Hot Tool. Submit Sur,haMeState &Faar Publimtions MC Staff MIS Site Map i.. [Inks I Seard, 9onda -pr 3(r Product Approval USER: PUser Pmdud Approval Menu> ProaaR or Aoof cion SeartM1> Anolimtlnn List> FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluadon Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence SCANNED FL12765-R4 BY Affirmation 1 2014 St. Lucie County Approved r ]anus International Corporation 134 East Luke Road Temple, GA 30179 (770) 562-2850 Ext 360 carts@janusintl.com Curtis Schroeder torts@janusintl.com Curtis L. Schroeder 134 Janus International Blvd. Temple, GA 30179 (770) 562-2850 Ext 360 curls@janusinti.com Jake Lyons 134 ]anus International Blvd. Temple, GA 30179 (770) 562-2650 Ext 304 jakel@janusintl.com Exterior Doors Roll -Up Exterior Door Assemblies Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ZI Evaluation Report - Hardcopy Received Joseph H. Dixon, Jr PE-7768 National Accreditation and Management Institute 12/31/2018 Gordon Thomas, P.E. ❑ Validation Checklist - Hardcopy Received FL12765 R4 COI 29018 Cert of 8. indeo.udf Referenced Standard and Year (of Standard) Standard year ANSI/DASMA 108 2005 ASTM E330 - 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By http://www.floridabuilding.org/pr/Pt app_dtl.aspx?param=wGEVXQwtDgsmFBeODh9XI... 9/20/2016 Florida Building Code Online Page 2 of 3 C Sections from the Code WRI affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity OYes ONo ON/A FL32765 R4 CDC 35008 self affirm 12765 R3.adf Product Approval Method Method 1 Option D Date Submitted 03/10/2015 Date Validated 03/10/2015 Date Pending FBC Approval Date Approved 03/15/2015 Summary of Products FL # Model, Number or Name Description 12765.1 Series 1100 Series 1100 - 26 Gauge Door Assebmly Max Size: 8'-B" x 14'-0" Limits of Use Installation Instructions Approved for use in HVHZ: No FL12765 R4 If 29018 Dwe T1012 Rev A.udf Approved for use outside HVHZ: Yes FL12765 R4 II 290tS install 750 1300.odf Impact Resistant: No Verified By: Joseph H. Dixon, Jr. 7768 Design Pressure: +24.4/-27 Created by Independent Third Party: No Other: Not for use in High Velocity Hurricane Zones Evaluation Reports FL12765 R4 AE ER-09-00088RR gdf Created by Independent Third Party: Yes 12765.2 Series 1100 Series 1100 - 26 Gauge Door Assembly Max Size: 10'-0" x 14'-0' Limits of Use Installation Instructions Approved for use in HVHZ: No FL12765 R4 JI 29018 Own T1013 Rev A.odf Approved for use outside HVHZ: Yes FL12765 R4 II 29016'nstoIL750 110-0.pdf Impact Resistant: No Verified By: Joseph H. Dixon, Jr. 7768 Design Pressure: +19.4/-22.7 Created by Independent Third Party: No Other: Not for use In High Velocity Hurricane Zones Evaluation Reports FL12765 R4 AE ER-09-0008-R.odf Created by Independent Third Party: Yes 765.3 Series 3100 Series 3100 - 26 Gauge Door Assembly Max Size: 16'-0" x 20'-0" Limits of Use Installation Instructions Approved for use in HVHZ: No FL12765 R4 11 34012 Dwo T1004 E.odf Approved for use outside HVHZ: Yes FL32765 R-4 II 34022 Mod 3100 lost instr.odf Impact Resistant: No Verified By: Joseph H. Dixon, Jr. 7768 Design Pressure: +36/-41 Created by Independent Third Party: No Other: +36/-41 psf at 12'-0" wide. Varying loads are Evaluation Reports shown for widths 8'-0" to 16'-0". Not for use in High Velocity FL12765 R4 AE M3100 FL12765 TIOOSG P2.odf Created by Independent Third Party: Yes Hurricane Zones 12765.4 Series 3100 Series 3100 - 26 Gauge Door Assembly Max Size: 20'-0" x 20'-0" Limits of Use Installation Instructions Approved for use in HVHZ: No FL12765 R4 If 32041 FL T1005-F 0002.pdf Approved for use outside HVHZ: Yes FL12765 R4 11 34022 Mod 3100 Inst instr.pdf Impact Resistant: No Verified By: Joseph H. Dixon, Jr. 7768 Design Pressure: +35/-38 Created by Independent Third Party: No Other: +35/-38 psf at 16'-0" wide. Varying loads are Evaluation Reports shown for widths 15'-0" to 20'-0". Not for use In High 07 R2 120112 0 Created by Independent Third Party: Yes Velocity Hurricane Zones 12765.5 Series 750 Series 750 — 26 Gauge Door Assembly Max Size: 3'-0" x 12'-0" Limits of Use Installation Instructions Approved for use in HVHZ: No FL12765 R4 lI 29018 Own T1000 Rev B.odf Approved for use outside HVHZ: Yes FL12765 R4 11 29018 Install 750 1100.odf Impact Resistant: No Verified By: Joseph H. Dixon, Jr. 7768 Design Pressure: +35/-45 Created by Independent Third Party: No Other: Not for use in High Velocity Hurricane Zones Evaluation Reports http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsmFBeODh9XI... 9/20/2016