HomeMy WebLinkAboutSUBMITTED PAPPERSDATE:
FEES Dun:
RECEIPT #:
1. Location/Site Address:
2. Parcel ID Number: 4
Planning & Development Services Department
Building & Code Regulation Division SCANNED
2300 Virginia Avenue
Ft Pierce, FL 34982-5652 BY
Tel. 772462-1553 St. Lucie County
APPLICATION O D/l!►7'. 1DT.n1%rTT
F R
Office Use
Section
Townsbip
Range
Map Page
I Zoning
Land Use
Initials
Only
3. Description of Projector Work Activity: -j�E f}(KM(41_ 1
4. Total Roof Area (square feet): ` .2M 5. Roof Pitch:
6. Type of Roof. [ ] Fiberglass Shingle [ ] Concrete Roof Tile
[ ] Wood Shake / Shingle
[ ] Tar & Gravel [ Modified Bitumen [ ] Other
[kf Product Approval required for all types of Roofing Material (2 Sets)
[<rAll Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
7. Owner Information
Name: 66v) 'vii Qf+a✓7
2^Z L V,1106e,
Address: v(
City: State (•-,L
zip: 5qg170 Phone:
8. Contractor Information
/vlC. FL Reg/Cert#: C Cr_ (3a (oC:57 L(
County Cert #: Q-50q ( I
Business Name: L( lk Red&3h C
Cell Phone: -7-7a a60
9. Value of Construction: $ -11550 .°O
"Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in this aRaIWali is correct and that all work will be
done in compliance with all applicable m/ ion and zoning.
Ti�2Q laS c .
PRINT QUA IFIERS/OWNERS NAME
,� BSI E OF QUALIFI + OWNER
�,/
STATE OF FLORIDA, COUNTY OF / � O I+n
ACKNOWLEDGED BEFORE ME THIS —7 DAY Oyi Uar�- 20� BY I _ a gins E.
WHOPERSONALLYKNO TO OR HASP ODUCED AS IDEN'`I``jQRGAYR�s����i�
_c aesfi Q�3Q, tGi
IGNA OF NOTA TYPE OR PRINT NAME OF NOTARY (seal) ,? O
COMMISSION NUMBER
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING,
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4262010
NOTICE OF COMMENCEMENT
Permit No. Tax Folio No. 51O -OGO / —Cx1G
State of Florida County of St. Lucie
The undersigned hereby gives notice that improvementwill be made to certain real property, and in accordance with Chapter713, Florida Statutes,
the following information is provided in this Notice of Commencement.
,,q(o -��6 - vD 6
Owner infor anon or Lessee information if the Lessee contracted for the improvement:
Name liyl/SIOI�YtryliflW! f�S50UG-%LQZf CYC r�/e(,_ itlaa= (hir.
Address I eCbPaybour Kto4e vA. ! -17 14vn
Interest in property: bLf Me ' J I
Name and address of fee simple titleholder (if different from Owner listed above):
Contractor's Name: C0de_V M �od�� CS -.-T—hr, .
Contractor Address: --A 0.ct Phone Number:
r-L 34497
Surety (if applicable, a copy of the payment bond is attached): Amount of bond: $
Name and address: Phone number:
Lender Name: Phone Number:
Lenders address:
Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Sect
Name: _
Address:
In addition to himself or herself, Owner designates
Lienors Notice as provided in Section 713.13(1) (b), Florida Statutes.
Phone number of person or entity designated by owner:
to receive a copy of the
Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final payment to the
contractor, but will be 1 year from the date of recording unless a different date is specified)
WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OFTHE NOTICE OF COMMENCEMENT ARE CONSIDERED
IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE FOR
IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE THE FIRST
INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK OR
RECORDING YOUR NOTICE OF COMMENCEMENT.
Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of
my knowledge and belief/]
or Owners or Lessee's Authorized
SHERRI KELLEY
MY COMMISSION # EE22S005
EXPIRES October04.2016
The f r going instru ent was acknowledged before me this day of l�t�l� 20 ✓,
B, as for
N f Perso Type of authority (e.g. officer, trustee) Party on behalf ofwhomInstrument was executed
Kqp
Personally known_ or produced Identification_
(' ure of Notary Public - State of FI ridaj
(Print, Type, or Stamp Commissioned Name of Notary Public) Type of Identification produced
f
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 34992
772-462-2165 or772-462-2172
Fax:772-462-6443
ROOF INSPECTION AFFIDAVIT
Re: Permit# /,Y0 j— 00G 3
I, DOIJ4.0 Q.O,� . licensed as a(n)Contractor*/Engineer/Architect
(Please pant name & circle license type) *FS468 Building Inspector
*General, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection.
On or about FEb ZS` 7n I . I did personally inspect the roof deck nailing
(Date)
work at: 17L4314 Net r ba L � P— Po 1
(job site address)
Based upon that examination I have determined the installation was done according to the current
edition of the Florida Existing Buildin C e Section 611 or the product approval submitted (whichever is
most strigent).
00C 137-61 Z'f
Signature and Seal' License #
STATE OF FLO DA
COUNTYOF
Sworn to and subscribed ore me this Oday of LV 20�
by Who is personally known to me -or ho has produced
as identi ication.
Notary Public, State of
Signature of Notary
Commission Number.
En 01/19/2011
(Seal)
02/13/2014 11:30 772-287-7763 CODE RED ROOFERS PAGE 04/04
JOSEPH E. SMITH, CLERK C- ';E CIRCUIT COURT - SAINT LUCIE COUNTY . 1.
FILE H 3912243 OR BOOK ' PAGE 2132, Recorded O1/O3/2014 at 1 ,j PM
1 N�jCE OF COMMENCEMENT
Permit No. I W Q� Ob ( J Tex FallO
State of Ronda C,ntYd S.LUCIe .
The und0nIRned hambygrc nptitethatlmDmvemem xdll be made mccrti n reel pmparry, end In acmrdanrg with Chapter 7T3, Florida Sfatutpt,
the followingi�dprmenan is providadin this Npri¢pof Canimnncemmt.
Lwl lismipt6a-twppertr.(and street addmr, If.-nahial. �`"'l /`S'va6
General descipdoa
Name
Address
Interest in
Name and
Surety (If apPlirahle, a WPV of the Payment band N Mthad); Anspunt of hnnd: }`
Nameandaddresst ._Phone
tendar Name: Phaea Number
tander'eaddmsa:
Par RIM YAthinthaStete atFlarida destgmted by O—or upon wh9m naNmt w otherdcamanle may twearved as prwlded bySettion
Z14.7,9(11 7, Radtl Statute: t.����
Name: i u` rum a 'T7,'j pri4 %Wt
Address: L F! �u44/s
In addidpn to himtelf arhemNf, Ovmerdesignatas A to raaaNeBmpy Ofthe Uenol'a Nodeaas proWdad m seenan n3.13(t) (hJ, gpnda Statutes,
Phena numberof pallon prmdry deslgneted Wavmer.
FaPirauon datPaFnadm p}<pmmen�msM: (the &phonon date may not be befomtbe wmpletwh Of construction and final paymemto the cumnaor, butwDl be IYaerf nenthe date ofrewmirg unless a diffemntdemis p9offer0
WMNIN070 OWNER; ANYPAYMOM MADEDYTHE OWNER AFTERTNE EXPIRATION OFTNE NOTICE OF COMMENCEMENTAAE CONSIDERED
IMPROPER PAYMENTSUNDERCHIMTER T13,PART I, SECUON 133.13, FIORIDASTAME$, MUM IRMLTIN YOUR PAYINGTWICEFOR
IMPROYEMEFOSTOYOUR PROPERTY. A NOTICE OF COMMENUMENTMUSTUS XBOOMED AND POSTED ONTNE 100 SOE t1EFORETRE illu7 INSPERiON.IFYOU INTENDTOOBTAIN RNMCING, CONSULT WON YOUR IFNDER OR AN ATTORNEYREFOflE COMMENCING WORROR RECORD(NOYOUR NOOCEOPCOMMENCEMENT.
UnderpeneityeF perjury, t dederethatl have reed the foregoing rrotice of wmmencememand thatthe fans stated therein ere truato the bast of
mV knowledge end hellafn
51HEM Kg"EV
11YOOMk MION0LET70d(
EVINS$10"A Or04,2010
Th. f Rolnelmr entwasadotWedpdbafinemetbls-ikdayofr0.41'_. , 2cj.
By >� as for
f rw Type ofauthonry(e.g.offlWtruaee) Partyon behel/ef whpminseNmemwas eltemted
( ONmary Pubic-SgwpfR ride) Per{pnallYfnuwn-,�m0ucedldennliurlon,
(r OnLTYPgwStamPUa MISNoned NameofNMary Publz) Type of ldentl/btWA produmd
STATE OF FLORIDA
ST.'LUCIE COUNTY
THIS ISM CERTIFYTHAMISISA
TRUF.AND CORRECT COPY OF THE
ORIGIWAL.
Data'
re2-�.n
Tu�' ,, in
12
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
ANCE
Polyglass USA, Inc.
150 Lyon Drive
Fernley, NV 89408
'3LIN
X.
9`00
MIAMI-DARE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
THESE PLANS AND ALL PROPOSED 717a61315-2590 F (786) 315-2599
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).'
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Modified Bitumen Roof System Over Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews NOA# 12-0710.04 and consists of pages 1 through 32.
The submitted documentation was reviewed by Alex Tigera.
Ma1Mt•DADE COUNTY
CONCEALED FASTENERS ORATIACHME
ARE THE RESPONSIBILITY OFTHE
ST. LLICIK COUNTY NOX'N'o?:'313=0316:if5;
BUILDING DIVISION
REVIEWED E iration Date: 09/13/17
FOR COMPLIA A pproval Date: 07/18/13
REVIEWED BY Page 1 of 32
DATE O . 07 0
PLANSAN PERM
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
FIE (COPY
TURQUOISE Engineering, LLC
Structural Engineering, Design & Testing, CA #28948, NOA #13-0222.02
6915 Washington Rd, W Palm Beach, FL 33405 / Ph. (561) 804-9908 / Fax (561) 804-9907 / e-mail: turginc@aol.com
January 06, 2014
TO: St. Lucie County / Building Department
FROM: Riza N. ALTAN. P.E.
SUBJECT: Wind Uplift & Flat Re -Roofing Specifications
ADDRESS: 12434-12448 Harbour Ridge Blvd., Palm City, FL 34990
CONTRACTOR:Code Red Roofers
Dear Sir;
The re -roofing specifications of flat areas of the subject condominium units have been
reviewed by myself. The purpose of this letter is to determine the wind uplift pressures
and specify enhanced spacing of mechanical fasteners for roof base sheet.
The flat roofs take place in Exposure D area and the mean roof height is 23 ft. The roofs
consist of 5/8" CDX plywood deck having positive drainage. As per 2010 Florida Bldg.
Code, ASCE 7-10, for Risk Category II, 170 MPH ultimate wind velocity in Exposure D
area, using Wind Load Factor of 0.6 for ASD; The wind pressures are determined as
follows:
Field Pi = -52 psf / Perimeter (4' wide) P2 = -87 psf / Corner (4'x4') P3 = -131 psf.
The proposed "Polyglass Modified Bitumen Roof Systems (NOA #13-0416.05) over Wood
Decks" consists of simultaneously mechanically fastened Elastobase base sheet over
1" ISO insulation boards followed by torched -down PolyFlex G cap sheet.
The max. design pressure, -60 psf (Deck 1I, Syst. 1)(1) pg. 25/32, Lim. #7), is specified by
re -nailing the existing deck using 8d ring-shanked nails spaced at 4" o.c. and fastening
the base sheet with OMG Roofgrip Fasteners and Flat Bottom Plates spaced at 12" o.c
along 4" wide laps and 12" o.c., staggered two (2) rows in mid -sheet.
It is required that, in order to meet the actual roof pressures, as per RAs-117, the
spacing of fasteners are enhanced as follows:
Zone 1: Field (Intermediate areas): @ 12" o.c., two staggered rows in mid -sheet
Zone 2: Perimeter (4' from edges): @ 9" o.c., three staggered rows in mid -sheet
Zone 3: Corners (4' from ea. side): @ 6" o.c., three staggered rows in mid -sheet
Laps: (4" wide) Field: @ 12" o.c., Perimeter: @ 9" o.c., & Corners: @ 6" o.c.
Therefore, this letter is to certify that installation of Polyglass Modified Bitumen Roof
Systems (NOA #13-0416.05) will conform to requirements of 2010 Florida Bldg. Code
which specifies 170 MPH ultimatewind velocityfor Risk Category II in Exposure D area.
If you have any questions regarding this matter or I
do not hesitate to call me.
Sincerely, � tj
Riza N. ALTAN, .E. # 8521 Irk
Consulting Engineer
�GENSE �s
L
No.sazt
• f
{VJEOf �Q
.'�ONAL E���•
please
Z:sl
mal ��� f
ROOFING ASSEMBLY APPROVAL
Category
Roofing
Sub -Category:
Modified Bitumen
Materials
SBS/APP/TPO
Deck Type:
Wood
Maximum Design Pressure
-112.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE
1
Test
Product
Product Dimensions Specification
Description
Polyflex 32' 10" x 3' 3-3/8" ASTM D 6222
Torch applied, polyester reinforced, APP modified
bitumen membrane with a bum off polyethylene back
face and a smooth or sanded top surface.
GPilyflelG�ff 30;';x 3=3-378"'�'i�ST1C1 D',632
Torch applied, polyester reinforced, APP modified
bitumen membrane with a bum off polyethylene back
face and a granule top surface.
Polyflex G FR 32' 10" x 3' 3-3/8" ASTM D. 6222
Torch applied, polyester reinforced, APP modified
bitumen membrane with a bum off polyethylene back
face and a granule top surface and fire retardant
chemistry.
Polybond 32' 10" x 3' 3-3/8" ASTM D 6222
Torch applied, polyester reinforced, APP modified
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
Polybond G 32' 10" x 3' 3-3/8" ASTM D 6222
Torch applied, polyester reinforced, APP modified
Type 1
bitumen membrane with a burn off polyethylene back
face and a granule top surface.
Elastoflex S6 32' 10" x 3' 3-3/8" ASTM D 6164
Torch, hot asphalt or cold adhesive applied, polyester
reinforced, SBS modified bitumen membrane with a
bum off polyethylene or sanded back face and a
polyethylene or sanded top surface.
Elastoflex S6 G 32' 10" x 3' 3-3/8" ASTM D 6164
Torch, hot asphalt or cold adhesive applied, polyester
reinforced, SBS modified bitumen membrane with a
bum off polyethylene or sanded back face and a
granule top surface.
Elastoflex S6 G FR 32' 10" x 3' 3-3/8" ASTM D 6164
Torch, hot asphalt or cold adhesive applied, polyester
reinforced, SBS modified bitumen membrane with a
burn off polyethylene or sanded back face and a
granule top surface and fire retardant chemistry.
Elastoshield TSG 32' 10" x 3' 3-3/8" ASTM D 6164
Torch, hot asphalt or cold adhesive applied, polyester
reinforced, SBS modified bitumen membrane with a
- - - -
burn off polyethylene or sanded back face and a
granule top surface. .
NOA No.: 13-0416.05
Expiration Date: 09/13/17
Approval Date: 07/18/13
,Page 2 of 32
FNIE COPY.
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product Dimensions Specification
Description
Elastoshield TSG FR 32' 10" x 3' 3-3/8" ASTM D 6164
Torch, hot asphalt or cold adhesive applied, polyester
reinforced, SBS modified bitumen membrane with a
burn off polyethylene or sanded back face and a
granule top surface and fire retardant chemistry.
Elastoflex V 32' 10" x 3' 3-3/8" ASTM D 6163
Torch, hot asphalt or cold adhesive applied, fiberglass
reinforced, SBS modified bitumen membrane with a
bran off polyethylene or sanded back face and a sanded
top surface. Also available in a thicker version listed as
Elastoflex V 2.5.
Polyfresko Mop 32' 10" x 3' 3-3/8" ASTM D 6164
Torch, hot asphalt or cold adhesive applied, polyester
reinforced, SBS modified bitumen membrane with a
bum off polyethylene or sanded back face and a
granule top surface.
Polyfresko Mop FR 32' 10" x 3' 3-3/8" ASTM D 6164
Torch, hot asphalt or cold adhesive applied, polyester
reinforced, SBS modified bitumen membrane with a
bum off polyethylene or sanded back face and a
granule top surface and fire retardant chemistry.
Polyfresko Torch 32' 10" x 3' 3-3/8" ASTM D 6222
Torch applied, polyester reinforced, APP modified
bitumen membrane with a bum off polyethylene back
face and a granule top surface. .
Polyfresko Torch FR 32' 10" x 3' 3-3/8" ASTM D 6222
Torch applied, polyester reinforced, APP modified _.
bitumen membrane with a burn off polyethylene back
face and a granule top surface and fire retardant
chemistry.
ASTM D 6163
SBS modified asphalt coated fiberglass reinforced base
Type I
sheet.
Elastobase P 65' 2" x 3' 3-3/8" ASTM D 6164
SBS modified asphalt coated polyester reinforced base
sheet.
Cold Process 1, 3, 5, 50, 55 gal. or ASTM D3019
A fibered cold process adhesive for use with roll or
Adhesive tube Type III
BUR roofing.
PGL00 Asphalt 1, 3, 5, 50, 55 gal, ASTM D4 L
A penetrating solution of solvent and a blend of "
Primer tube or 17 oz. spray
selected asphalts used to promote adhesion,
can
PG350 Mod Bit 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with
Adhesive
tube
Type III
modified bitumen membranes.
PG400 Plastic Roof
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement for use in
Cement
tube
ASTM D3409
dry or damp conditions.
PG425 Wet/Dry Roof
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement for use in
Cement
tube
ASTM D3409
dry or damp conditions.
i
NOA No.: 13-0416.05 ..
MAMMADE COUNTY
Expiration Date: 09/13/17
Approval Date: 07/18/13
Page 3' of -32'
4 LE COPY,
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Test
Product
Product
Dimensions
Specification
Description
PG450 Flashing
1, 3, 5, 50, 55 gal, or
ASTM D4586
A thick, fibered, rubberized flashing cement.
Cement
tube
PG500 MB Flashing
1, 3, 5, 50, 55 gal. or
ASTM D4586
A thick, fibered, rubberized flashing cement for use
Cement
tube
with modified bitumen membrane's.
Polyplus 35 Premium
1, 3, 5, 50, 55 gal. or
ASTM D3019
A fibered rubberized adhesive designed for use with
Mod Bit Adhesive
tube
Type III
modified bitumen membranes. -
Polyplus 45 Premium
1, 3, 5, 50, 55 gal. or
'ASTM D4586
A thick, fibered, rubberized flashing cement.
Flashing Cement
tube
Polyplus 50 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586
MB Flashing Cement tube
Polyplus 55 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586
Modified Flashing tube
Cement
APPROVED INSULATIONS:
Product Name
POLYTHERM
POLYTHERM Composite
ACFoam II, ACFoam III
High Density Wood Fiberboard
Dens -Deck or Dens Deck Prime
FescoBoard
H-Shield
. ENRGY 3
Multi-Max-3, Multi -Max FA-3
SECUROCK Gypsum -Fiber Board
TABLE 2
A thick, fibered, rubberized flashing cement for use
with modified bitumen membranes.
A mastic compound for use as a roof flashing adhesive:
x
Product Description
Polyisocyanurate foam insulation
Polylso/perlite composite insulation.
Polyisocyanurate foam insulation
Wood fiber insulation board
Gypsum insulation board
Rigid perlite roof insulation board.
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Polyisocyanurate foam insulation
Fiber reinforced coverboard
Manufacturer
(With Current NOAI
Polyglass USA, Inc.
Polyglass USA, Inc.
Atlas Roofing Corporation
Generic
Georgia Pacific Gypsum LLC
Johns Manville Corp.
Hunter Panels, LLC
Johns Manville Corp.
Rmax Operating, LLC
USG Corporation
MIAMFDADE COUNTYM NOA No.: 13-0416.05
Expiration Date: 09/13/17
'Approval Date: 67/18/13
Page 4 of 32
APPROVED FASTENERS:
TABLE 3
Fastener
Product
Product
Number
Name
Description
1.
Dekfast 12, Dekfast 14
Insulation fastener for wood, steel
& Dekfast 15 HS
and concrete decks
2.
Dekfast Galvalume
Galvalume hex stress plate.
Steel Hex Plate
3.
Dekfast Dekflat Round Polypropylene locking plate.
Plastic Lock Plate
4.
412 Standard Roofgrip
Insulation and membrane fastener
& #14 Roofgrip
5.
Flat Bottom Metal
Galvalume AZ50 stress plate
Plate
6.
OMG Plastic Plate
Polyethylene stress plate
7.
Trufast #14 HD
Insulation fastener for steel and wood
Fastener
decks
8.
Trufast 3" Metal
Galvalume steel plate
Insulation Plate
J
Manufacturer
Dimensions (With Current NOA)
SFS Intec, Inc.
2 7/s" x- SFS Intec, Inc.
3 1A"
3" x 3 1/4" SFS Intec, Inc.
Various
OMG, Inc..
3" square
OMG, Inc.
3.2" round
OMG, Inc.
Altenloh, Brinck & Co.
U.S., Inc.
3" round
Altenloh, Brinck & Co.
U.S.; Inc.
s
�a
i
NOA No.: 13-0416.05 1 '
Expiration Date: 09/13/17
Approval Date: 07/18/13
Page 5 of 32 ,
0
APPROVED SURFACING:
TABLE 4
Number
Product
Product
Ani lication
Specification
Manufacturer
Name
Description
Rate
1.
PG200 Non-Fibered
A non fibered asphaltic coating
1'/z-2 gaUsq
TAS 140
Polyglass USA,
Roof Coating
used to add life and rejuvenate
Inc
existing BUR roofing
substrates.
2.
PG300 Fibered Roof
An asphalt cutback fibered roof
1'/z-2 gal/sq
ASTM D4479
Polyglass USA,
Coating
coating. May be applied by
Inc.
brush or spray equipment to
rejuvenate aged BUR
3.
PG600 Non-Fibered
Non-fibered aluminum roof
'/2-1 gaUsq
ASTM D2824
Polyglass USA,
Aluminum Roof
coating.
Type I
Inc.
Coating
4.
PG650 Fibered
Fibered aluminum roof coating.
1'/-2 gaUsq
ASTM D2824
Polyglass USA,
Aluminum Roof
Type 111
Inc.
Coating
5.
PG700 White
A premium white elastomeric
1-1'/2 gaUsq
ASTM D6083
Polyglass USA,
Elastomeric Roof
acrylic based roof coating
Inc,
Coating
(water -based). A polyester
fabric may be used for
reinforcement with this
coating.
6.
PG800 Non-Fibered
An asphalt based, non-fibered
3 gaUsq in two
ASTM D1227
Polyglass USA,
Asphalt Emulsion Roof clay emulsion
coats
Inc.
Coating
7.
PG850 Fibered Asphalt
An asphalt base, fibered clay
3 gal/sq in two
ASTM D1227
Polyglass USA,
Emulsion Roof Coating emulsion
coats
Inc.
S.
Polyplus 65 Premium
Fibered aluminum roof coating.
1'/-2 gaUsq
ASTM D2824
Polyglass USA,-
Fibered Aluminum
Type III
Inc.'
:r1:
Roof Coating
9.
Polyplus 60 Premium
Non-fibered aluminum roof
%z-1 gaUsq
ASTM D2824
Polyglass USA,
Non-Fibered
coating.
Type I
Inc;
Aluminum Roof
Coating
i
10.
Polybrite 70 White
A premium white elastomeric
1-1'/z gaUsq
ASTM D6093
Polyglass, USA;',
Elastomeric Roof
acrylic based roof coating
Inc.
Coating
(water -based). A polyester
fabric may be used for
reinforcement with this
coating.
11.
Gravel
To be installed in a flood coat
400 ibs/sq
N/A
Generic
---
of approved asphalt at 60 lbs/sq
12.
Slag-
To be installed in a flood coat
3001bs/sq
N/A
Generic
of approved asphalt at 60 lbs/sq
.
MIAMMOLDE co urm
NOA No.: 13-0416.05
HEM,
Expiration -Date: 09/13/17
Approval Date: 07/18/13
Page 6 of 32
};
HLE COPY,-.
EVIDENCE SUBMITTED:
Test Agencv
Test Name/Report
Report No.
Date
Factory Mutual Research
4470
J.I.2W7A7.AM
08.04.94
Corporation
4470
J.I.3001334
02.15.00
4470
J.1.3000857
01.12.00
4470
J.I.3004091
01.12.00
Underwriters Laboratory
TAS 114
OONK20869
06.08.00
TrinriY I ERD
TAS 114
#11751.05.03
05.30.03
TAS 114
11757.12.00-1
12.01.00
TAS 114
11757.04.01-1
04.27.01
TAS 114
#11758.08.03
08.11.03
TAS 114
01738.02.07
02.05.07
TAS 117(B)-ASTM D6862
C8500SC.11.07
11.30.07
ASTM D 6164 / D 6222
P10490.10.08-RI
10.03.08
ASTM D6222
P37590. 07.13-2
07.01.13
ASTM D6222
P37590.03.13-5-R1
07.01.13
ASTM D6509
P37590.03.13-1-RI
06.26.13
ASTM D6164
P37590.03.13-3A
.03.06.13
ASTM D6164
P37590.07.13-1
07.02.13
ASTM D6163
P37590.03.13-2-R1
07,01.13
PRI Asphalt Technologies
ASTM D6222
PUSA-062-02-01
12,04.07
ASTM D6163
PUSA-064-02-02
02.27,08`
NOA No.: 13-0416.05
Expiration Date: 09/13/17
Approval Date: 07/18/13
Page 7 of 32
F, LE COPY.'��;
Deck Type 11: Wood, Insulated
Deck Description: 19/32' or greater plywood or wood plank, fastened with 8d common nails at 4" o.c. or 48 screws
at 6" o.c.
System Type D(1): All layers of insulation and base sheet mechanically fastened.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Laver Insulation Fasteners Fastener
able 3 Density/ft'
Any appi ov x _9lytsocanurafe"GisjW,iri Table 2
C�Im�mpm "tFi`ck N/A N/A
Too Insulation Laver (Ontional) Insulation Fasteners Fastener
able 3 Density/ft' ; 41
FescoBoard
Minimum 3/," thick N/A N/A "
Approved High Density Wood Fiberboard
Minimum %" thick N/A N/A
Dens Deck, Dens Deck Prime, SECUROCK Gypsum -Fiber Board
Minimum ''/a" thick N/A N/A
Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a
minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4
ft., and four fasteners for any insulation board having no dimension greater than 8 ft.
$as_eSheet ?Oe or more plies o'PElastoliase or Elastobase P fastened to the deck as described below:
fastenings A"H-Wbasse sheet using OMG Roofgrip Fasteners and Flat Bottom Metal Plates spaced 12" o.c.
ida 4"Tap and 12" o.c. in two equally spaced staggered rows in the center of the sheet.
Ply Sheet: (Optional) One or more plies of Polyflex or Polybond torch applied or one ply of Elastobase,
Elastoflex S6, Elastoflex V, or Elastoflex V 2.5 or one or more plies of Type IV or VI ply sheet
adhered in full mopping of approved asphalt applied within the EVT range and at a rate of 20-40
ibs,/sq.. `
- Ala
1VI_emtirane: One ply of Polyflex, P 1 fl , Polyflex G FR, Polyfresko Torch, Polyfresko Torch FR ,
Polybond, or Polybond G torch applied or one ply of Elastoflex S6 G, Elastoflex S6 G FR,
Polyfresko Mop, Polyfresko Mop FR, Elastoshield TSG or Elastoshield TSG FR•.Lor hot
asphalt applied.
Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired
coating or required fire classification.
Maximum Design
Pressure: -60 psf, (See General limitation #7) -
Mu1MMADEcoUN" NOA No.: 13-0416.05
Expiration Date: 09/13/17
Approval Date: 07/18/13
Page 25 of 32
Fpu
FIN - Lt COPY
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control
Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the
EVT range and at a rate of 2040 lbs./sq., or mechanically attached using the fastening pattern of the top layer.
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size .
shall be 4' x 4' maximum.
4.
An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot
mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each
side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is
not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application
of either system shall be at a minimum rate of 121bs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf
5.
Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lb£, as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 Ibf. insulation attachment shall not be acceptable.
6.
Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener
r c;ti
resistance value in conjunction with the maximum design value listed within a specific system. Should the
fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing,
prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered. Roof".
Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from
Testing Application Standards TAS 105 and calculations in compliance with'Rooflng Application Standard RAS
117.
7.
Perimeter and comer areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer,':
Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this
NOA, General Limitation #9 will not be applicable.)
8.
All attachment and sizing of perimeter nailer, metal profile, and/or flashing termination designs shall conform to •
'
Roofing Application Standard RAS I 1 and applicable wind load requirements.
9.
The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
•!y'
END OF THIS ACCEPTANCE
MIAMMOMr COUNTY _ NOAN6.: 13-04ff,.O5�-
Expiration -Date: 09113117�
Approval Date: 07/18/13
Page 32 of, 32 , ,
n
x
- � " �-. .�� ®7*
, . . - � � � V� �
�' � ^ /� � � � � `�9
' ��� %�\/\��/y2aw�«%
� � �6�.\�2\>��9.±5ƒ2a
� = � � 4«� „
� 7� . % � \� � � � � / a?:'`�
:,
e��� *ww�
: .r« o:>»S- a �
a z. ; ± � � ¥. x�� � � � �
.�.
� &/�..�\/�f ���\� \\�.: ~
% ® - �� 3 > K' / , y.
� a�� .:� ��� �/. . .
� �a�� ��=;sa<.�.....� |,
��
-
. »r.
-�:7-04
=s
Ra,S -• ell
YYi
r .ry t ro
A. •' +��Ii�� .yam..
7^... 1OLa 1 f•'•
v
q a
®
0
e o o e o
® ® ® O O O O ® ® O
1'. A. ,
v > •' a. .+
lot
oa600000000p'000OA0'®�®®F�®�".�
�'4.60 ® ®
dlk j4 �p .,