Loading...
HomeMy WebLinkAboutSUBMITTED PAPPERSDATE: law Planning & Development Services Department Building & Code Regulation Division 2300 Virginia Avenue Ft. Pierce, FL 34982-5652 SCANNED Tel. 772462-1553 BY APPLICATION FOR ROOF PERMIT St, 1. Location/Site Address:)) L&rKr-) UJ'- ?l fcg'x _ I _NVO 2. Parcel ID Number: ``T� d �UQQ I✓© 3. Description of Projector Work. Activity: 4. Total Roof Area (square feet): "5 �2M 5. Roof Pitch: `/y 42 2 ' 6. Type of Roof: [ ] Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle [ ] Tar & Gravel &Modified Bitumen [ ] Other [kTProduct Approval required for all types of Roofing Material (2 Sets) ji on Ca> [,]'All Commercial Roofing requires. design by an Engineer or Architect (2 Sets) with Product Approval attached ** Roof Mitigation per F.S. 553.844 will be required. Owner Information 8. Contractor Information Name: CAn. i Q-bav7 tkkf f l e (ode Address: 4Z60 City: State: Zip: 15LIWO Phone: ��G — 3 CCU 9. Value of Construction: $ -19 650 -00 fPic. FLReg/Cert#: CCC—V3 69Cj74 County Cert #: a-.;504 Business Name: 4zed &awls � r Cell Phone: zip 2&0 063?j "Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval. CONTRACTOR/OWNEWS AFFIDAVIT: I certify that all of the information contained in this a 'cation is correct and that all work will be done in compliance with all appllca e-1 gnfa ' tcabKoh and zoning. PRINT QUA i URS/OWNERS NAME GN OF QUALIFiER/OWNER STATE OF FLORIDA, COUNTY OF MI, ACKNOWLEDGED BEFORE E TIES DAY O U[t� 20 rLm , BY I E. Ze WH PERSONALLY 0 TO OR HASP ODUCED AS IDENTIFICATION \ \\\Ig1111111111II&I, S G OF NOTARY GG TYPE OR PRINT NAME OF NOTARY (seal) COMAIMMIONNUMBER EE 4 NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY F99UET INS® TAYE FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAIN FINANCING, "'fbffh ATTORNRevised EY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT. � AIE NOTICE OF COMMENCEMENT Permit No. State of Florida County of St. Lucie Tax Folio No. 1111a6-510 -OGnq '000 - r The undersigned herebygives notice that improvementwill be made to certain real property, and in accordance with Chapter713, Florida Statutes, the following information is provided in this Notice of Commencement. qoC Owner )nfor�m1 ation or Lessee information if the Lessee contracted for the improvement: Name ( liyl/�O[�ttlyli!lW!° rJel��d Vi[(aAvIC Address 6;-Z& Y �(U4,e (-%&ta rfi i 1� e /wl Interest in property: r9t, nEr 1) 1 Name and address of fee simple titleholder (if different from Owner listed above): Contractor's Contractor A C. Surety (if applicable, a copy of the payment bond is attached): Amount of bond: Name and address: Lender Name: _ Lender's address: Number: Number: Persons within the State of Florida designated by Owner upon whom notices or other documents may be served as provided by Secl 713.1311) W7., Florida Statutes: _ _ . , . ;1", In addition to himself or herself, Owner designates Lienor's Notice as provided in Section 713.13(1) (b), Florida Statutes. Phone number of person or entity designated by owner: to receive a copy, Expiration date of notice of commencement: (the expiration date may not be before the completion of construction and final paymeri contractor, but will be 1 year from the date of recording unless a different date is specified) WARNING TO OWNER: ANY PAYMENTS MADE BY THE OWNER AFTER THE EXPIRATION OF THE NOTICE OF COMMENCEMENT ARE CON IMPROPER PAYMENTS UNDER CHAPTER 713, PART I, SECTION 713.13, FLORIDA STATUTES, AND CAN RESULT IN YOUR PAYING TWICE F IMPROVEMENTS TO YOUR PROPERTY. A NOTICE OF COMMENCEMENT MUST BE RECORDED AND POSTED ON THE JOB SITE BEFORE T INSPECTION. IF YOU INTEND TO OBTAIN FINANCING, CONSULT WITH YOUR LENDER OR AN ATTORNEY BEFORE COMMENCING WORK( RECORDING YOUR NOTICE OF COMMENCEMENT. zOTv,�- mArgO pu?m �r >>nm rn�"mrnr avnc7-- o� �cs �m <n a m v X X �o Om Under penalty of perjury, I declare that I have read the foregoing notice of commencement and that the facts stated therein are true to the best of my knowledge and bel!)29 (Signatory's By or Owners or Lessee's Authorized Officer/Director/Partner/Manager acknowledged before me this Ayday of� , 20L./ �111 as (Signature of Notary Public - State of (Print, Type, or Stamp Commissioned for Type of authority (e.g. officer, trustee) SHERM KELLEY MY COMMISSION # EE225005 EXPIRES October 04, 2016 Party on behalf of whom instrument was executed Personally known V or produced Identification_ of Notary Public) Type of Identification produced i� �;,� f��.,,, "i } . ��i ,. � » r].'�.. 02/13/2014 11:30 772-287-77F?� CODE RED ROOFERS .PAGE 01/04 sT09EPA E. SMITR, CLERK IETE CIRCUIT COURT — SASNT LUCIE COUNTY FILE N 3912246 OR BOOK PAGE 2135, Recorded 01/03/2014 at =U PM N(TnCE OF COMMENCEMENT ➢Molt ND._��4V� WIO� Tax Folio No. .z6-.�r0 -00074—OGO,��% Stateof Florida COuntyafSt.LUde The undRrApied hereby gives none that ImPlIh m"t wIR be made to certain real property, and In accordance vAM C'hapter713, Florlda Statutes, thefollming il*p Uvn Is provided In this Native of Ow umwment. J^ {r teens beaW 'M ae..ne• "'A ae�.r sae—,u..—a_�,_,. X 3%s-(/06 Gemumidestriptiunaf �I}TI a A ar l - a Surety Of apPftmtl yaWRY Ofthe payment bond is attached): Amount tender Name: Phone Number tenders address: personswRNn no State of Florida 4Wgnebed by Owner upon Whom notim or other documents may be carved as Firm lded by section nsaRrn rev_ 11"U% Rn —' In addidon W ldrnaeH or halself, Owner dWgRatea Of tO moeive a Wpy of the Uenars NaOce as provided in $,dUOn 713.13(1) (b), Flogde Statutes. Phone numberof Per,an or mtlry desk rabsd by owner Eapll1110A them of notke of whu ensement:(the erplydZlan datamaY not be WDM the wmPIGUOR of WrlstrUCHan and final Payment to the Mmmaor, butwgl be 1 Yearfmm the dete efreWrding unless a ddfarent date is specdted) WARNING TO OWNER: ANY PAYMENTS MADE BYTHE OWNER AFTER THE EXPIRATION OF THE Ron CE OF COMMENCEMENT ARE CONSIOERED IMPROPER PAYMENTS UNDER CHAPCER 7f3, PART I, SECTION 713.0, FLONCIA STATURE$, AND CAN RESULT IN YOUR FArNGTWICE MR IMPROVEMENTSTO YOUR PROPERTY.A NOTICE OF COMMENCFASENT MUST BE RECORDED AND POSTE➢ ON THE JOB 511E BEFORE THE FIRST INSFECDON. IPYOU INTEND To OurAIN FINANCING, CONSULT WaHYOUR LENDER OR AN ATTORNEY BEFORE COMMENONG WORK OR RECORDING YOUR NOTICE OF W MMENO:MFNi_ - bavamad the famRaingnotka of mmmmcement eM thatthe facts stated thareln amtn.etothe beet of SHERRI KELLEY la'gnacorvv lmervmcef J //fit— pJIPIREpOfbbnOE,=01E y (1a11 IN tanrr.rra.sx.m. Tbakrp/gding lnstmmeMwa�s ipnknnawledged ba(am ma thifi dayof . 70 BygI as For I P 77X ofaothtxRY(.E• AOr, frostael party an behalf of wham lmtrumentwas erecoted (sgneture aFNpta ublk•Srate of Fl nda) Per=anaRYknewe �rprodumdrdemffk time (FRnf, Type, or S;. CommisilonethN rrYa of Notary Public) Type of kentlfkatlm produced_ STATE OF FLORIDA ST. LUCIE COUNTY `t THIS IS TO CERTIFY THATTHIS IBA TRUEAND CORRECT COPY OFTHE' ORIGINAL, A� dOSE�'!L F;SA1)TH 't ✓iD s 2014 it � MIAM � MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11905 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA)THESF PI ARIS N www.miamidade.eov/economy � ��� rrrer��O Polyglass USA, Inc. ARE SUBJECT TO ANY CORRECTIONS 150 Lyon Drive REQUIRED BY FIELD INSPECTORS THAT Fernley, NV 89408 MAY BE 14ECESSARY IN ORDER TO SCOPE: COMPLY WITH ALL APPLICABLE CODES. This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Polyglass Modified Bitumen Roof System Over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews NOA# 12-0710.04 and consists of pages 1 through 32. The submitted documentation was reviewed by Alez Tigera. - - — MIAM4DADE COUNTY CON6SALBD FASTINIRS ON ATTACHM AMTHE F SPONSIBIIITYOFTHE OONIRA=OFRECORD ST. LUCIE COUNTY BUILDING DIVISION FOR REVIEWED BY DATE Ole BE KEPT ON JOB OR ECTION WILL BE MADE NISATNb?:T�]3=Q41"6:1157 Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 1 of 32 t Oka I TURQUOISE Engineering, LLC Structural Engineering, Design & Testing, CA #28948, NOA #13-0222.02 6915 Washington Rd, W Palm Beach, FL 33405 / Ph. (561) 804-9908 / Fax (561) 801AG / e-mail: turginc@aol.com TO: St. Lucie County / Building Department FROM: Riza N. ALTAN, P.E. SUBJECT: Wind Uplift & Flat Re -Roofing Specifications ADDRESS: 12454-12468 Harbour Ridge Blvd., Palm City, CONTRACTOR:Code Red Roofers Dear Sir; ' J uary 06, 201.4 e I 0 FL 34990 01)0 The re -roofing specifications of flat areas of the subject condominium units have been reviewed by myself. The purpose of this letter is to determine the wind uplift pressures and specify enhanced spacing of mechanical fasteners for roof base sheet. The flat roofs take place in Exposure D area and the mean roof height is 23 ft. The roofs consist of 5/8" CDX plywood deck having positive drainage. As per 2010 Florida Bldg. Code, ASCE 7-10, for Risk Category II, 170 MPH ultimate wind velocity in Exposure D area, using Wind Load Factor of 0.6 for ASD; The wind pressures are determined as follows: Field P1 = -52 psf / Perimeter (4' wide) P2 = -87 psf / Corner (4'x4') P3 = -131 psf. The proposed "Polyglass Modified Bitumen Roof Systems (NOA #13-0416.06) over Wood Decks" consists of simultaneously mechanically fastene as o a basegsheet over 1IS�rrtssraatatlon booms followed by torched -down PolyFlex G cap sheet. The max. design pressure, -60 psf (Deck 1I, Syst. D(1) pg. 25/32, Lim. #7), is specified by re -nailing the existing deck using 8d ring-shanked nails spaced at 4" o.c. and fastening the base sheet with OMG Roofgrip Fasteners and Flat Bottom Plates spaced at 12" o.c along 4" wide laps and 12" o.c., staggered two (2) rows in mid -sheet. It is required that, in order to meet the actual roof pressures, as per RAS-117, the spacing of fasteners are enhanced as follows: Zone 1: Field (Intermediate areas): @ 12" o.c., two staggered rows in mid -sheet Zone 2: Perimeter (4' from edges): @ 9" o.c., three staggered rows in mid -sheet Zone 3: Corners (4' from ea. side): @ 6" o.c., three staggered rows in mid -sheet Laps: (4" wide) Field: @ 12" o.c., Perimeter: @ 9" o.c., & Corners: @ 6" o.c. Therefore, this letter is to certify that installation of Polyglass Modified Bitumen Roof Systems (NOA #13-0416.05) will conform to requirements of 2010 Florida Bldg. Code which specifies 170 MPH ultimate wind velocity for Risk Category II in Exposure D area. If you have any questions regarding this matter or I may ��P)Vl4i4@tsistance, please do not hesitate to call me. `\\\�`a�1.»„ 1��1,t,��r„r` Sincerely, / IJ ��o.3 521 6` Riza N. ALTAN, P. 21 GYME of Consulting Engineer '.� &ORV 4,4 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Modified Bitumen Materials SBS/APP/TPO Deck Type: Wood Maximum Design Pressure -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description Polyflex Polyflex G FR Polybond Polybond G 32' 10" x 3' 3-3/8" ASTM D 6222 U::- 0_'-x 3' 3-3/8'''_=_ASTX4TR6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. Torch applied, polyester reinforced, APP modified bitumen membrane with a bum off polyethylene back face and a granule top surface. 32' 10" x 3' 3-3/8" ASTM D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a granule top surface and fire retardant chemistry. 32' 10" x 3' 3-3/8" ASTM•D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. 32' 10" x 3' 3-3/8" ASTM D 6222 Torch applied, polyester reinforced, APP modified Type I bitumen membrane with a burn off polyethylene back face and a granule top surface. Elastoflex S6 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a bum off polyethylene or sanded back face and a polyethylene or sanded top surface. Elastoflex S6 G 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a granule top surface. Elastoflex S6 G FR 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a bum off polyethylene or sanded back face and a granule top surface and fire retardant chemistry. Elastoshield TSG 32' 10" x 3' 3-3/8" ASTM D 6164 Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a granule top surface. MUIMHAME COUNTY ,.... 1 NOA No.: 13-0416.05 Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 2 of 32 FILE COPY TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Dimensions Specification Elastoshield TSG FR 32' 10" x 3' 3-3/8" ASTM D 6164 Elastoflex V Polyfresko Mop Polyfresko Mop FR Polyfresko Torch Polyfresko Torch FR ==`Elastobase Elastobase P Cold Process Adhesive PG100 Asphalt Primer PG350 Mod Bit Adhesive PG400 Plastic Roof Cement 32' 10" x 3' 3-3/8" ASTM D 6163 32' 10" x 3' 3-3/8" ASTM D 6164 32' 10" x 3' 3-3/8" ASTM D 6164 32' 10" x 3' 3-3/8" ASTM D 6222 32' 10" x 3' 3-3/8" ASTM D 6222 Product Description Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a bum off polyethylene or sanded back face and a granule top surface and fire retardant chemistry. Torch, hot asphalt or cold adhesive applied, fiberglass reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a sanded top surface. Also available in a thicker version listed as Elastoflex V 2.5. Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a bum off polyethylene or sanded back face and a granule top surface. Torch, hot asphalt or cold adhesive applied, polyester reinforced, SBS modified bitumen membrane with a burn off polyethylene or sanded back face and a granule top surface and fire retardant chemistry. Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a granule top surface. Torch applied, polyester reinforced, APP modified bitumen membrane with a bum off polyethylene back face and a granule top surface and fire retardant chemistry. 65_2" z 3' 3=3/8"- ASTM D 6163 SBS modified asphalt coated fiberglass reinforced base Type I sheet. 65' 2" x 3' 3-3/8" ASTM D 6164 SBS modified asphalt coated polyester reinforced base sheet. 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered cold process adhesive for use with roll or tube Type III BUR roofing. 1, 3, 5, 50, 55 gal, ASTM D41 A penetrating solution of solvent and a blend of tube or 17 oz. spray selected asphalts used to promote adhesion. can 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with tube Type III modified bitumen membranes. 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement for use in tube ASTM D3409 dry or damp conditions. PG425 Wet/Dry Roof 1, 3, 5, 50, 55 gal_or ASTM D4586 A thick, fibered, rubberized flashing cement for use in Cement tube ASTM D3409 dry or damp conditions. NOA No.: 13-0416.05 Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 3 of 32 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description PG450 Flashing 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement. Cement tube PG500 MB Flashing 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, frbered, rubberized flashing cement for use Cement tube with modified bitumen membranes. Polyplus 35 Premium 1, 3, 5, 50, 55 gal. or ASTM D3019 A fibered rubberized adhesive designed for use with Mod Bit Adhesive tube Type III modified bitumen membranes. Polyplus 45 Premium I, 3, 5, 50, 55 gal. or ASTM D4586 A thick, fibered, rubberized flashing cement. Flashing Cement tube Polyplus 50 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A thick, frbered, rubberized flashing cement for use MB Flashing Cement tube with modified bitumen membranes. Polyplus 55 Premium 1, 3, 5, 50, 55 gal. or ASTM D4586 A mastic compound for use as a roof flashing adhesive. Modified Flashing tube Cement APPROVED INSULATIONS: TABLE 2 Product Name Ialwaoil tlt78l POLYTHERM Composite ACFoam II, ACFoam III High Density Wood Fiberboard Dens -Deck or Dens Deck Prime FescoBoard H-Shield ENRGY3 Multi-Max-3, Multi -Max FA-3 SECUROCK Gypsum -Fiber Board APPROVED Product Description Polyisocyanurate foam insulation Polylso/perlite composite insulation. Polyisocyanurate foam insulation Wood fiber insulation board Gypsum insulation board Rigid perlite roof insulation board. Polyisocyanurate foam insulation Polyisocyanurate foam insulation Polyisocyanurate foam insulation Fiber reinforced coverboard Manufacturer (With Current NOA) Polyglass USA, Inc. Polyglass USA, Inc. Atlas Roofing Corporation Generic Georgia Pacific Gypsum LLC Johns Manville Corp. Hunter Panels, LLC Johns Manville Corp. Rmax Operating, LLC USG Corporation NOA No.: 13-0416.05 Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 4 of 32 APPROVED FASTENERS: TABLE 3 Fastener Product Product Number Name Description 1. Dekfast 12, Dekfast 14 Insulation fastener for wood, steel & Dekfast IS HS and concrete decks 2. Dekfast Galvalume Galvalume hex stress plate. Steel Hex Plate 3. Dekfast Dekflat Round Polypropylene locking plate. Plastic Lock Plate 4. #12 Standard Roofgrip Insulation and membrane fastener & #14 Roofgrip 5. Flat Bottom Metal Galvalume AZ50 stress plate Plate 6. OMG Plastic Plate Polyethylene stress plate 7. Trufast #14 HD Insulation fastener for steel and wood Fastener decks 8. Trufast 3" Metal Galvalume steel plate Insulation Plate {.iffl ry hey j g• _ {Y t i,� Manufacturer Dimensions (With Current NOA) SFS Intec, Inc. 2 7/s" x SFS Intec, Inc. 3 'A" 3" x 3 '/a" SFS Intec, Inc. Various OMG, Inc. 3" square OMG, Inc. 3.2" round OMG, Inc. Altenloh, Brinck & Co. U.S., Inc. 3" round Altenloh, Brinck & Co. U.S., Inc. NOA No.: 13-0416.05 Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 5 of 32 APPROVED SURFACING: LE COPY TABLE 4 Number Product Product Application Specification Manufacturer Name Description Rate 1. PG200 Non-Fibered A non fibered asphaltic coating 1'/: 2 gal/sq TAS 140 Polyglass USA, Roof Coating used to add life and rejuvenate Inc existing BUR roofing substrates. 2. PG300 Fibered Roof An asphalt cutback fibered roof 1'/a-2 gaVsq ASTM D4479 Polyglass USA, Coating coating. May be applied by Inc. brush or spray equipment to rejuvenate aged BUR 3. PG600 Non-Fibered Non-fibered aluminum roof /2-1 gal/sq ASTM D2824 Polyglass USA, Aluminum Roof coating. Type I Inc. Coating 4. PG650 Fibered Fibered aluminum roof coating. 1'/2-2 gal/sq ASTM D2824 Polyglass USA, Aluminum Roof Type III Inc. Coating 5. PG700 White A premium white elastomeric 1-1'/z gal/sq ASTM D6083 Polyglass USA, Elastomeric Roof acrylic based roof coating Inc. Coating (water -based). A polyester fabric may be used for reinforcement with this coating. 6. PG800 Non-Fibered An asphalt based, non-fibered 3 gal/sq in two ASTM D 1227 Polyglass USA, Asphalt Emulsion Roof clay emulsion coats Inc. Coating 7. PG850 Fibered Asphalt An asphalt base, fibered clay 3 gal/sq in two ASTM D 1227 Polyglass USA, Emulsion Roof Coating emulsion coats Inc. 8. Polyplus 65 Premium Fibered aluminum roof coating. 1'/z 2 gal/sq ASTM D2824 Polyglass USA, Fibered Aluminum Type III Inc. Roof Coating 9. Polyplus 60 Premium Non-fibered aluminum roof /3-I gaVsq ASTM D2824 Polyglass USA, Non-Fibered coating. Type I Inc. Aluminum Roof Coating 10. Polybrite 70 White A premium white elastomeric 1-1'/z gaVsq ASTM D6083 Polyglass USA, Elastomeric Roof acrylic based roof coating Inc. Coating (water -based). A polyester fabric may be used for reinforcement with this coating. 11. Gravel To be installed in a flood coat 400 Ibs/sq N/A Generic of approved asphalt at 60 lbs/sq 12. Slag To be installed in a flood coat 300 lbs/sq N/A Generic of approved asphalt at 60 lbs/sq MIAM4D COUNTY NOA No.: 13-0416.05 ,,.., � I6 Expiration Date:09/13/17 Approval Date: 07/18/13 Page 6 of 32 EVIDENCE SUBMITTED: Test Agency Factory Mutual Research Corporation Underwriters Laboratory Test Name/Report 4470 4470 4470 4470 TAS 114 Trintiy ERD TAS 114 TAS 114 TAS 114 TAS 114 TAS 114 TAS 117(B)-ASTM D6862 ASTM D 6164 / D 6222 ASTM D6222 ASTM D6222 ASTM D6509 ASTM D6164 ASTM D6164 ASTM D6163 PRI Asphalt Technologies Report No. Date J.I.2W7A7.AM 08.04.94 J.1.3001334 02.15.00 JJ.3000857 01.12.00 J.I.3004091 01.12.00 OONK20869 06.08.00 #11751.05.03 05.30.03 11757.12.00-1 12.01.0 0 1175 7.04.01-1 04.27.01 411758.08.03 08.11.03 01738.02.07 .02.05.07 C8500S C.11.07 11.30.07 P 10490.10.08-R1 10.03.08 P37590.07.13-2 07.01.13 P37590.03.13-5-RI 07.01.13 P37590.03.13-1-RI 06.26.13 P37590.03.13-3A 03.06.13 P37590.07.13-1 07.02.13 P37590.03.13-2-R1 07.01.13 ASTM D6222 PUSA-062-02-01 12.04.07 ASTM D6163 PUSA-064-02-02 02.27.08 NOA No.: 13-0416.05 Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 7 of 32 Deck Type 1I: Wood, Insulated Deck Description: 19/32' or greater plywood or wood plank, fastened with 8d common nails at 4" o.c. or #8 screws at 6" o.c. System Type D(1): All layers of insulation and base sheet mechanically fastened All General and System Limitations apply. One or more layers of the following: FILE COey Base Insulation Laver Insulation Fa able 3 Density/fe Any approved Polyisocyanurate) isted"� ` Tablel I�Ii'nim' um 1"atiick N/A N/A Too Insulation Laver(Outionab Insulation Fasteners Fastener able 3 Density/ft' FescoBoard Minimum'/," thick N/A N/A Approved High Density Wood Fiberboard Minimum'/2" thick N/A N/A Dens Deck, Dens Deck Prime, SECUROCK Gypsum -Fiber Board Minimum''/4" thick N/A N/A Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. Base -Sheet- `Or more plies o-fElastobase or Elastobase P fastened to the deck as described below: ;Fastening: Affacfi'base sheet using OMG Roofgrip Fasteners and Flat Bottom Metal Plates spaced 12" o.c. _ 11--a4'_'_lap and 12" o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: (Optional) One or more plies of Polyflex or Polybond torch applied or one ply of Elastobase, Elastoflex S6, Elastoflex V, or Elastoflex V 2.5 or one or more plies of Type IV or VI ply sheet adhered in full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq.. emtira_ne: One ply of Polyflex, Pol hex G, Polyflex G FR, Polyfresko Torch, Polyfresko Torch FR, Polybond, or Polybond G torch applied or one ply of Elastoflex S6 G, Elastoflex S6 G FR, Polyfresko Mop, Polyfresko Mop FR, Elastoshield TSG or Elastoshield TSG FREOric i or hot asphalt applied. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -60 psf, (See General limitation #7) NOA No.: 13-0416.05 Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 25 of 32 WOOD DECK SYSTEM LIMITATIONS: HLE COPY 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: I. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer. 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 Ibf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 11 I and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) END OF THIS ACCEPTANCE NOA No.: 13-0416.05 Expiration Date: 09/13/17 Approval Date: 07/18/13 Page 32 of 32 8 G •1 v vv , 1 r rr 1' 1 n ' Y£ } F uc Y. Y� 4 I 1 H .Yc o w �rn 3 y t 2 1'd ¢N !d Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 772-462-2165 or 772-462-2172 Fax: 772-462-6443 ROOF INSPECTION AFFIDAVIT Re: Permit# JLJOO — 00(00 I, Doi $14�_ [) licensed as a(n)Contractor*/Engineer/Architect (Please print name & circle license type) *FS468 Building Inspector *Genera, Building, Residential or Roofing Contractor or any individual certified under 468 F.S. to make such an inspection. On or about 20 )y . I did personally inspect the roof deck nailing (Date) work at: l7_45y-124[• pr6ur Rick� Bud (Job site address) Based upon that examination I have determined the installation was done according to the current edition of the Florida Existing Building Code Section 11 or the product approval submitted (whichever is most strigent). and Seal STATE OF FLO I A COUNTY OF AO-V4i NC- 13,266W License # Sws �a to and subscribed before me this (K day of 2014 by LZ4IQS E. Who is personally known to me or w o has pro duced as identification. Notary Public, Statep�,'GCA gF,gi Signature of Notary: C ¢,• Commission Number: Seal ( ) �p� 17^ En 01/19/2011 _ _ _ v *EE871345 'aQ, ..� °;��'"�; � ' ,e � we k e * ¢ �;: 1 � °� � .�= � Yam. d � t�: '" � � � ^ 3d �, � � ;�� �,c� •��It � y� � I�l aiY �R �T+�e �� � •w - . ,�� a c� � „ ,qq } �► . r a�, •� ii �• �' <• £"l{�� �! •Zt � SAL ' ,� ^.il u' v m