HomeMy WebLinkAboutFEILD DENSITY PAPPERS1-7 b-I - 6) 3 �- (! `� ETC SCANNED BY St. Lucie County FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 116th Way, Suite 1 Fl:jj 'A4un0aU!pn1-4S U�I4Mlaml, FL 33178 4J2d2Q 51Lu2ja tool. 305-882-8200 • fax 305-882.120 Ol Permit No: 1704-0137 Project No.: 3996000423 Client: Wawa Inc. Technician: Ahmed Mokhtar r;; Project: Wawa Store # 5220. DATE: April 13, 2018. General Contractor: Hooks Construction. Grading Contractor: Mosley & Son Construction. TEST PROCTOR IF LIFT WET DRY MOISTURE MOISTURE % OF DENSfrY as ELEVATION BELOW DEPTH BELOW LOCATION GRID COORDINATES OR ROADWAY STATION NO. NO. DENSITY DENSITY (PCF) MAX PASS FAIL PIETIES FINISH PLAN • (PCF) (PCF) TNO GRADE (FT.) SUBGRADE SPEC. gCNAL 1 108.7 120.6 103.6 17.0 16.4 95.0 95.3 x T-6" Canopy's footingLine (3, D). C.L 2 108.7 121.3 103.4 17.9 17.3 95.0 95.1 x T-6" Cano s footingLine 3, C). C.L 3 108.7 113.0 97.1 15.9 16.4 95.0 89.3 x T-6" Cano s footingLine 3, B . C.L. 4 108.7 112.9 96.0 16.9 17.6 95.0 88.3 X 7'-6" Canop s fooling Line (3, A). C.L 5 108.7 119.4 103.5 15.9 15.4 95.0 95.2 x 7'-6" Canopy's footing Line (2, D). C.L 6 108.7 120.3 105.1 15.2 14.5 95.0 96.7 x 7'-6" Cano s footingLine (2, C). C.L 7 108.7 118.7 103.8 14.9 14.4 95.0 95.5 x 7'-6" Canopys footingLine (2, B). C.L 8 108.7 119.0 104.5 14.5 13.9 95.0 96.1 x 7'-6" Canopy's footingLine 2, A). C.L 9 108.7 117.9 106.0 11.9 11.2 95.0 97.5 . x 6'-6" Cano s footingLine 3, D). C.L. 10 108.7 117.9 108.4 9.5 8.8 95.0 99.7 x 6'-6" Canop s footing Line (3, C). C.L Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot_ Brickfoot Rubber -tired Vibratory Plate x Walk Behind Steel Drum Other: Jumping Jack Vibrator Remarks: Above locations are compacted to firm conditions and dense conditions Except footings 3,B & 3,A . More Compaction work is required for footings footings 3,B & 3,A . *Proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor Mod. Proctor Rcspectfully,Submitvd ��gE. F •.,,• sa 'iccs LLC,,•"�y' - �Go i 23828 108.7 11.6 x _ •, •.; ., ., STATEOF Itp Alex a, iag�yl `��.,e�1',•.f(ORIDt; �yW g .. Senior Enginccr --i"•y/pNAC BNG�p"J" Flor da L:ccnsc H 52514 ,,,,,,,,,,n• - r Soil Density Report Disclaimer -Mesa test results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only. The degreeot ` compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." ' Ur L Z 9nv ��� Group Services LLC 9955 NW 116th Way, Suite 1 Miami, FIELD DENSITY -NUCLEAR METHOD Miami, FL 33176 ASTM 13-6938 tel. 305.882.8200 • fax 305-BB2-1200 Permit No: 1704-0137 Project No.: 3996000423 Client: Wawa Inc. Technician: Ahmed Mokhtar Project: Wawa Store # 5220. DATE: April 13, 2018. General Contractor: Hooks Construction. Grading Contractor: Mosley & Son Construction. TEST PROCTOR LIFT WET DRY MOISTURE MOISTURE % OF « ELEVATION BELOW DEPTH BELOW NO. NO. NO. DENSITY DENSITY (PCF) y MAX DENSITY PASS FAIL RETES FINISH PLAN LOCATION GRID COORDINATES OR ROADWAY STATION •(PCF) (PCF) T NO GRADE (FT.) SUBGRADE SPEC. IACMAL 11 110.4 117.5 106.8 10.7 10.0 95.0 96.7 X 6'-6" Canopys footing Line 3, e . C.L 12 110.4 116.9 104.9 12.0 11.4 95.0 95.0 x 6'-6" Canopys footing Line (3, A). C.L 13 110A 118.9 107.1 11.8 11.0 95.0 97.0 x 6'-6" Canopys footing Line 2, D . C.L 14 110.4 117.6 108.4 9.2 8.5 95.0 98.2 x 6'-6.. Canop s footing Line (2, C). C.L 15 110.4 120.4 107.7 12.7 1 11.8 95.0 97.6 1 x 6'-6" Canopys footing Line (2, B). C.L 16 110.4 114.8 107.4 7.4 1 6.9 95.0 97.3 X 6'-6" Canopys ofing Line 2, A). C.L Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Brickfoot Rubber -tired Vibratory Plate x Walk Behind Steel Drum Other: Jumping Jack Vibrator Remarks: Above locations are compacted to firm conditions and dense conditions. *Proctor Respectfully Submitted pN. No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor Mod. Proctor ATC G p. c LC,,r'" t 23806 110.4 13.90% x ;... �� JCENSF::1 0712 t STATE OF a 1 Alcz=E.$�•9'•:<OflIDI+,tp.4rF F._ Senior Engineer `sS ...•....;... p, NALE • Florida LiccnscH 62519 „u _ �� MNIIIII Soil Density Report Disclahner - 'These lest results should be regarded as indicators of the degree of compaction attained at these spot locations and deliths onh/. The degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office.' f - E�TG FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 116th Way, Suite 1 Miami, FL 33178 tal. 305-882.8200 - fax 305-882-1200 Permit No: 1704-0137 Project No.: 3996000423 Client: Wawa Inc. Technician: Ahmed Mokhtar Project: Wawa Store # 5220. DATE: April 16, 2018. General Contractor: Hooks Construction. Grading Contractor: Mosley 8 Son Construction. TEST PROCTOR LIFT WET DRY MOISTURE MOISTURE .. ELEVATION BELOW DEPTH BELOW NO. NO. NO DENSITY DENSITY (PCF) PASS FAIL RETES FINISH pLp(,I LOCATION GRID COORDINATES OR ROADWAY STATION (PCF) (PCF) TNO GRADE(FT.) SUBGRADE 1 108.7 127.2 107.3 19.9 18.5 kIDENSITY x T-6" Cano s footin Line 1, D). C.L 2 108.7 125.9 105.2 20.7 19.7 x 7'-6" Cano s footin Line (1, C). C.L3 108.7 122.7 104.4 18.3 17.6 x T-6" Cano s footin Line 1, B). C.L4 108.7 125.7 107.7 18.0 16.7 .. x 7'-6" Canoloys footing Line 1, A). C.L 5 108.7 125.4 108.3 17.1 15.8 95.0 99.6 x T-6" Canop s footing Line (3, A). C.L 6 108.7 126.7 107.8 18.9 17.5 95.0 99.2 x 7'-6" Canopy's footing Line 3, B . C.I. 7 110.4 124.9 106.2 18.7 17.6 95.0 96.2 x 6-6" Canopys fooling Line 1, D). C.L 8 110.4 119.7 105.7 14.0 13.2 95.0 95.7 x 6-6" Canopys footing Line 1, C . C.L. 9 110.4 119.8 108.5 11.3 10.4 95.0 98.3 x 6'-6" Cano s footing Line 1, B . C.L 10 110.4 121.3 108.2 13.1 12.1 95.0 98.0 x 6'-6" Canop s footing Line (1, A). C.L Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot_ Brickfoot Rubber -tired Vibratory Plate x Walk Behind Steel Drum Other: Jumping Jack Vibrator Remarks: Above locations are compacted to firm conditions and dense conditions. J J 'Proctor No. 23828 Maximum Density (PCF) 108.7 Opt. Moisture (%) 11.6 Std. Proctor Mod. Proctor x RcspcclFully.Subm:ucd „ r•• •w ATC:Qr W S fYis LLC,,o'"dJ5 E' ....) W' •�jtEA;yF CGS 23806 110.4 13.9 - OF 4�;••., Q Alex an E. Ln - Florida r Florida Li So N 6251 .t Soil Density Report Disclaimer - -These test results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only. The degrea'of compaction at greater depths in the GO and at other locations as well as the condition of the underlying soils has not been determined by this office.' ATC Group Services LLC 9955 NW 116th Way, Suite 1 A T FIELD DENSITY - NUCLEAR METHOD Miami, FL 33178 AWN, CASTM D-6938 tel. 305-882-8200 • fax 305-882.1200 Permit No: 1704-0137 Project No.: 3996000423 Client: Wawa Inc. Technician: Ahmed Mokhtar Project: Wawa Store # 5220. DATE: April 20, 2018. General Contractor: Hooks Construction. Grading Contractor: Mosley & Son Construction. TEST PROCTOR LIFT WET DRY MOISTURE MOISTURE �. ELEVATION BELOW DEPTH BELOW NO. NO. NO DENSITY DENSITY (PCF) PASS FAIL RETES FINISH PLAN LOCATION GRID COORDINATES OR ROADWAY STATION • (PCF) (PCF) T NO GRADE (FT.) SUBGRADE 1 108.7 117.7 107.8 9.9 9.2 VA x 5'-6" Cano s footin area around Line 1 bet B, C L.S. 2 108.7 116.2 108.2 8.0 7.4 x V-6" Canop s footin area around Line 1 bet C, B R.S. 3 108.7 116.9 108.1 8.8 8.1 x 5'-6"Cano s footin area around Line 1 bet B, A4 108.7 114.4 108.4 6.0 5.5 .. x 5'4" Canop s footing Line 1.D). R.S 5 108.7 118.7 107.0 11.7 10.9 95.0 98.4 x 5'4" Canop s footing One (1,C). L.S 6 108.7 116.4 108.2 8.2 7.6 95.0 99.5 x V-6" Canopys footing Line 1,B). R.S 7 108.7 114.0 107.4 6.6 6.1 95.0 98.8 x 5'4" Canoloys footing One (1,A). L.S 8 108.7 119.5 108.6 10.9 10.0 95.0 99.9 x 5'-6" Caropys footing Line 2 Bet. D,C). 9 108.7 120.6 107.8 12.8 11.9 95.0 99.2 x 5'-6" Canoloys footing Line (2) Bet. C,B . 10 108.7 117.5 108.2 9.3 8.6 95.0 99.5 x 5'-6" Canop s footing Line (2) Bet. (B,A). Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Brickfoot Rubber -tired Vibratory Plate x Walk Behind Steel Drum Other: Jumping Jack Vibrator Remarks: Above locations are Compacted to firm conditions and dense conditions. 'Proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor Mod. Proctor d •""'• Respectfully SoSmirre.ATC Go�o' uup Sc LLC,,0 "� .......... ANN E 23828 108.7 11.6 x U SB'• >•' _ ., _... ,r, Aro: 62519 _ !,Alex a ,a n E, igi��..F...... .• 1b�"".' Senior Engincor Florida Li. so 62519 , '�.,,.,,x�n,•n' r Soil Density Report Disclaimer - 'These test results should be regarded as Indicators of the degree of compaction attained at these spot locations and depths only. the degre? of compacton at greater depths in the fill and at other locations as well as the condition of the underlying sots has not been determined by this office' _ ETC FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 116th Way, Suite 1 Miami, FL 33178 tel. 305-882.8200 • fax 305-882.1200 Permit No: 1704-0137 Project No.: 3996000423 Client: Wawa Inc. Technician: Ahmed Mokhtar Project: Wawa Store # 5220. DATE: April 20, 2018. General Contractor: Hooks Construction. Grading Contractor: Mosley & Son Construction. TEST PROCTOR NO. LIFT WET DENSITY DRY DENSITY MOISTURE MOISTURE« PASS FAIL RETES ELEVATION BELOW DEPTH BELOW LOCATION GRID COORDINATES OR ROADWAY STATION NO. NO. (PCF) (PCF) (PCF) /o T NO FINISH PLAN GRADE(FT.) SUBGRADE 11 108.7 121.1 107.8 13.3 12.3 kD�ENSMY x 5'-6" Cano s footin area around Line 2,D . R.S 12 108.7 114.9 108.2 6.7 6.2 x 5'-6"Cano s footin area around Line 2,C). R.8 13 108.7 114.8 108.4 6.4 5.9 x 5'-6" Canop s footin area around Line 2,B). R.S14 108.7 118.8 107.6 11.3 10.5 .. x 5'-6" Canoloys fooling Line (2,A). L.S 15 108.7 118.3 106.7 11.6 10.9 95.0 98.2 x 5'-6" Canopy's footing Line (3) Bet. (D,C). 16 108.7 120.1 108.3 11.8 10.9 95.0 99.6 x 5'-6" Canopy's footing Line (3) Bet. (C,B). 17 108.7 116.4 107.9 8.5 7.9 95.0 99.3 x 5'-6" Canopy's fooling Line 3) Bet. (B.A). 18 108.7 120.1 107.6 12.5 11.6 95.0 99.0 x T-6" Canopys footing Line 3,D). R.S 19 108.7 120.1 107.2 12.9 12.0 95.0 98.6 x 5'-6" Cano s footing Une 3,C . L.S 20 108.7 118.7 107.2 11.5 10.7 95.0 98.6 x 5'-6" Canop s footing Line (3,B). R.S Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Brickfoot Rubber -fired Vibratory Plate x Walk Behind Steel Drum Other: Jumping Jack Vibrator Remarks: Above locations are compacted to firm conditions and dense conditions. *Proctor No. Maximum Density (PCF) Opt. Moisture (%) Sid. Proctor Mod. Proctor RcspectPoily Submitted ATC r, rp Sc i.cs-LLC,,,'�"� �i��� F'.P4 +y Y'••' CFN"' f'GX 23828 106.7 11.6 x - i. � S° •- lox is a E. = �.e'•dQ oFF ...... n Senior Senior Briginccr-_.�s Florida Liccnsc # 62519 Soil Density Report Disclaimer°These test results should be regarded as Indicators of the degree of compaction altalned at these spot locations and depth; _Only. The,degree of mmpaCtlon at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office' , c�TC FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 116th Way, Suite 1 Miami, FL 33178 tel. 305-882-8200 • fax 305-882-1200 Permit No: 1704- 0137 Project No.: 3996000423 Client: Wawa Inc. Technician: Ahmed Mokhtar Project: Wawa Store # 5220. DATE: April 27, 201 B. General Contractor: Hooks Construction. Grading Contractor: Mosley S Son Construction. TEST PROCTOR LIFT WET DRY MOISTU MOISTURE %OFRE « ELEVATION BELOW DEPTH BELOW LOCATION GRID COORDINATES OR ROADWAY STATION NO. NO. NO DENSITY DENSITY (PCF) MAX DENSITY PASS FAIL RETES FINISH PLAN • (PCF) (PCF) T NO GRADE (FT.) SUBGRADE SPEC. ACTUAL 1 108.7 119.7 106.5 13.2 12.4 98.0 98.0 x 5-6" Area around Canopy's footing Line 1, D). R.S. 2 108.7 121.5 107.3 14.2 13.2 98.0 98.7 x 5-6" Cano sfooting Line 1 .8(D,C) 3 108.7 121.6 108.2 13.4 12.4 98.0 99.5 x 5-6" Canopy's footing Line 1, C . L.S 4 108.7 121.3 108.6 12.8 11.8 98.0 99.8 x 5-6" Canopys footing Line 1 .8 C,B 5 108.7 119.5 107.6 11.9 11.1 98.0 99.0 1 x 5-6" Canopy's footing Line (1, B). R.S. 6 108.7 119.1 107.4 11.7 10.9 98.0 98.8 x 5-6" Canopy's footinLine 1.8B,A Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum SheepsfootBrickfoot Rubber -tired Vibratory Plate x Walk Behind Steel Drum Other: Jumping Jack Vibrator Remarks: Above locations are compacted to firm conditions and dense conditions. Rc%Kctfnlly Submitted 16' *Proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor Mod. Proctor , A9 C,Gjti p Sc ccs LLC,,,"� PANp'° x'•'- GEN'•. CGi 23806 108.7 11.60% x �J - ^ t _��! �` V SS;. Ar0:-625 OVA r j STATEOF Alex a is E. = . 'Atifl101~r Wr.` Senior Engineer s%�NALENv, d0 Flurida Licrnxlrt625I9' Soil Density Report Disclaimer - 'These test results should be regarded as indicators of the degree of compaction attained at these spot locations and depths only. Tlie'degme of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office.' ETC FIELD DENSITY - NUCLEAR METHOD ASTM D-6938 ATC Group Services LLC 9955 NW 116th Way, Suite 1 Miami, FL 33178 tell. 305-882-8200 • fax 305-882-1200 Permit No: 1704-0137 Project No.: 3996000423 Client: Wawa Inc. Technician: Emmanuel Monuma Project: Wawa Store # 5220 DATE: 5/2/2018 General Contractor: Hooks Construction Grading Contractor: Wilson Petroleum PROCTOR WET DRY % OF •e ELEVATION BELOW DEPTH BELOW LOCATION GRID COORDINATES OR TEST NO. LIFT DENSITY DENSITY MOISTURE MOISTURE MAX DENSITY PASS FAIL RETEST ROADWAY NO. NO (PCF) (PCF) (PCF) o� NO FINISH PLAN STATION SPEC. ACTUAL GRADE (FT.) SUBGRADE 1 110.4 1 115.8 109.2 6.6 5.6 98.0 9B.9 x Subgrade Canopy area: Line 1 A B 2 110.4 1 116.0 109.0 7.0 6.0 98.0 98.7 x Subgrade Cano area: Line 1 B. C 3 110.4 1 116.1 108.4 7.7 6.6 98.0 98.2 x Subgrade Cano area: Line 1 C D 4 110.4 1 119.0 109.9 10.0 9.5 98.0 99.5 x Subgrade Canopy area: Line 2 A B 5 110.4 1 118.6 108.7 9.9 9.2 98.0 98.5 x Subgrade Canopy area: Line 2 B. C 6 110.4 2 118.6 108.4 10.2 9.8 98.0 98.2 x Subgrade Cano area: Line 2 C D 7 110.4 2 119.8 110.0 9.8 9.9 98.0 99.6 x Subgrade Canopy area: Line 3 A B 8 110.4 2 119.4 109.5 9.9 10.3 98.0 99.2 x Subgrade Cano area: Line 3 B C 9 110.4 2 119.2 108.9 10.3 10.0 98.0 98.6 x Subgrade Canopy area: Line-3 C. D Compaction Equipment Used: Vibratory: Non -Vibratory Smooth Steel Drum Sheepsfoot Brickfoot Rubber -tired Vibratory Plate X Walk Behind Steel Drum Other: Remarks: Above locations are compacted to firm conditions *Proctor No. Maximum Density (PCF) Opt. Moisture (%) Std. Proctor £.esCrSuhmitted rr""""�•••,� Mod. Proctor ATG' calfull iYEo P� 23806 110.4 13.9 X .' uGENSF cG� 3 ' y �, SiATE DF Senor ^-.ngincer '-css/pNAI , Florida Licsnsc 4 62519 G Soil Density Report Disclaimer - "These test results should be regarded as indicators of the degree of compaction attained at these spot locations antl depths only. The degree of compaction at greater depths in the fill and at other locations as well as the condition of the underlying soils has not been determined by this office." t ;ETC I--�L:14 —013-4- GGr�vt �sI 7 ATC G►; , Services LLC 9955 N.W.116 Way Suite 1 Miami, FI.33178 TELEPHONE (305) 882-8200, FACSIMILE (305) 882-1200 Compressive Strength Test of Concrete Cylinders Client Name: Wawa Inc. Date Cast: 7/20/2018 Project Name: Wawa Store #5220 Field Mark: JP-1 ProjectlD: 3996000423 Cylinder Set ID: 24564 Project Address: Prima Vista Blvd & Floresta Drive, Port St. Lucie Technician: Juan PaniS ION w.`` Permit No.: Supplier: Cemex BY St. LurJa {'.�... ,. . Sample Location: Fuel Pump strip along gridlines 1 & 2 Remarks: FIELD DATA Design Strength (PSI:) 4000 Slump (In.): 4 Mix Description: 4k psi SWP/Forta3.0 Placement: q t}p'AJ' noD G!'D '• Ticket Number: 35836626 Weather: WaWliedaa Truck Number: 8036 Concrete Temp ff): 80 Batch Time:' 10:25:00 AM Air Temp ff): 94 8107 L " "11 Time Sampled: 11:15:00 AM Air Content: Elapsed Time (Min): 50 Cubic Yards Sampled: i01 � ? Unit Wt: Number of Cylinders Cast. --- --- ----- - .- TEST RESULTS Curing (Days) TestDate Diameter (in) Area S in TotalLoad (lbs-force) CompressiveStrength (PSI) Break Type 7 7/27/2018 3.99 12.5 57210 4578 5 28 8/17/2018 4.03 12.75 65240 5117 5 28 8/17/2018 4.02 12.69 79580 6273 5 28 8/17/2018 4.03 12.75 65290 5121 2 56 9/14/2018 0 Compressive Strength Average (PSI) of the 28 day Breaks = 5500 PASS No Other Breaks Evaluated Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Reasonablywell- Well -formed cone on Columnervertical Diagonal fracture with Side fractures at lop or Similar to type 5, but formed cones on both one end,Vertical cracking through both no cracking through the bottom. (Occurs cylinder is pointed. ends, less than t in. cracks running through ends, no well formed ends; tap with hammer commonly with (25 mm) of cracking caps, no well-defined cones. to distinguish from type unbonded caps.) though caps. cone on other end. 1. All dimensions and directions are approximate I - I „....•.+•�,,,, Checked By: William Martin i Project Manager: �'ti`�" 1� \ l 1 ,dt't11,�.\JCEN F/4G� .'" . -;- �82519 - y`; STATE Or ' FIL"' ca_ SectorE �ineeY exi "0,��....ONID.... , Y- '. l IIli 1-1 ", a 2519 S10NgL ENG,1r` As a mutual protection to our client, the public and ourselves, all reports are submitted as the confidential property�bfdierifs: A.u4orization for publication of statements, conclusions, or extracts from our reports is reserved pendingwritten approval. Our reports apply only to the strengths of the test specimen& -and not to the iri-situ strengths of the members Indentified In the "Location"infornation. l } 1, ;ETC ATC Gi Services LLC 9955 N.W.116 Way Suite 1 Miami, FI.33178 TELEPHONE (305) 882-8200, FACSIMILE (305) 882-1200 Compressive Strength Test of Concrete Cylinders Client Name: Wawa Inc. Date -Cast: 7/23/2018 Project Name: Wawa Store #5220 Field Mark: JP-1 ProjectlD: 3996000423 Cylinder Set ID: 24593 Project Address: Prima Vista Blvd & Floresta Drive, Port St. Lucie Technician: Juan Paniagua Permit No.: Supplier: Cemex Sample Location: from gridline 1 to 22' E & from N edge of canopy slab to 9' S & from TN of center of slab to 12 W of Remarks: Water Added FIELD DATA Design Strength (PSI:) 4000 Slump (In.): 5.5 Mix Description: 4k psi fiber Placement: Pump Ticket Number: 35838787 Weather: Sunny Truck Number: 7679 Concrete Temp ff ): 76 Batch Time: 6:27:00 AM Air Temp ff): 80 Time Sampled: 7:25:00 AM Air Content: Elapsed Time (Min): 58 Cubic Yards Sampled: 20170 Unit Wt: I Number of Cylinders Cast: 5 Curino (Days) TestDate Diameter fin) Area S in TotalLoad (lbs-force) CompressiveStrenoth (PSI) Break Type 7 7/30/2018 4.02 12.69 44040 3472 5 28 8/20/2018 4.03 12.75 62650 4914 6 28 8/20/2018 4.01 12.62 57140 4527 5 28 8/20/2018 3.99 12.5 56770 4543 5 56 9/17/2018 0 Compressive Strength Average (PSI) of the 28 day Breaks = 4660 PASS No Other Breaks Evaluated Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Reasonablywell- Well -farmed cone on Columnervertical Diagonal fracture with Side fractures at top or Similar to type 5, but formed cones on both one end,Vertical cracking through both no cracking through the Iscuorn. (Occurs cylinder is pointed. ends, less than 1 in. cracks running through ends, no well formed ends; tap with hammer commonly with (25 mm) of cracking caps, no well-defined canes, to distinguish from type unbonded caps.) though caps. cone on other and. 1. " All dimensions and directions are approximate ` lY _ I, L 1............1-1 Checked By: William Martin Project Manager: ;` 1,-/' t l •, t., ... • F:,`G� 1 1 � � * v � g ; STATE OF ' _ exis Sc-Hier Epgineer Sg'•••••••••••"��,,+ FlorridayLicens&�tF e2519 �eNAL ENGn'' As a mutual protection to our client, the public and ourselves, all reports are submitted as the confidential propedy M clionts. Automation for publication of statements, conclusions, or extracts from our reports Is reserved pendingwriften approval. Our reports apply only to the strengths of the test specimens and not to the in -situ strengths of the members indentified in the "Location' information. ,,�/ i J,\ ATC Gr i Services LLC ArAkTc ` 9955 N.W.116 Way Suite 1 Miami, FI.33178 TELEPHONE (305) 882-8200, FACSIMILE (305) 882-1200 Compressive Strength Test of Concrete Cylinders Client Name: Wawa Inc. - Date Cast: 7/23/2018 Project Name: Wawa Store #5220 Field Mark: JP-2 ProjectlD: 3996000423 Cylinder Set ID: 24594 Project Address: Prima Vista Blvd & Floresta Drive, Port St. Lucie Technician:, Juan Paniagua Permit No.: Supplier: Cemex Sample Location: from 12' of center of slab to N edge of slab between gridline 3 & 4 Remarks: WaterAdded FIELD DATA Design Strength (PSI:) 4000 Slump (In.): 5.5 Mix Description: 4k psi fiber Placement: Pump Ticket Number: 35838950 Weather: Sunny Truck Number: 5403 Concrete Temp (OF): 76 Batch Time: 7:09:00 AM Air Temp (OF): 83 Time Sampled: 8:40:00 AM Air Content: Elapsed Time (Min): 91 Cubic Yards Sampled: 50/70 Unit Wt: Number of Cylinders Cast: 5 TEST RESULTS Curing (Days) TestDate Diameter (in) Area S in TotalLoad (lbs-force) CompressiveStrength (PSI) Break Type 7 7/30/2018 3.99 12.5 44910 3594 5 28 8/20/2018 4 12.56 55970 4456 5 28 8/20/2018 4.01 12.62 57810 4580 28 8/20/2018 4.02 12.69 60700 4785 56 9/17/2018 0 Type 1 Reasonably well - formed cones on both ends, less than 1 in. (25 mm) of cracking though caps. Compressive Strength Average (PSI) of the 28 day Breaks = 4610 PASS No Other Breaks Evaluated NE Type 2 Well -formed cone on one end vertical cracks running through caps, no well-defined cone on other end. TM All dimensions and directions are approximate Checked By: William Martin Type 3 Columnar vertical cracking through both ends, no well formed cones. Project Manager: Type 4 Diagonal fracture with no cracking though the ends; tap with hammer to distinguish from type 1. DE Type 5 Side fractures at top or bottom.(Occurs commonlywith unbonded caps.) A Type 6 Similar to type 5, but cylinder is pointed. E. STATE OF . Senior E� inin a rw %_ S``OeIOx..r§ 4' F'lolido LlG,nso#62519 S70NAL ENGn'''� ?... .......,,nr. As a mutual protection to our client, the public and ourselves, all reports are submitted as the confidential propefCy of clients. Auto"A� .n for po lication of statements, conclusions, or exbaets from our reports is reserved pendingwritten approval. Our reports apply only to the strengths of the test spGolmens and not to the Ina no strengths of the membere tndentified in the "Location' Information. 1 l ATC Gi: Services LLC 9955 N.W.116 Way Suite 1 Miami, FI.33178 - TELEPHONE (305) 882-8200, FACSIMILE (305) 882-1200 Compressive Strength Test of Concrete Cylinders Client Name: Wawa Inc. Date Cast: 7/24/2018 Project Name: Wawa Store #5220 Field Mark: JP-2 ProjectlD: 3996000423 Cylinder Set ID: 24595 Project Address: Prima Vista Blvd & Floresta Drive, Port St. Lucie Technician: Juan Paniagua . Permit No:: Supplier: Cemex Sample Location: Center fuel tank slab from N to S upto 11' N of canopy slab edge Remarks: FIELD DATA Design Strength (PSI:) 4000 Slump (In.): 5 Mix Description: 4k psi fiber Placement: Pump Ticket Number: 35841235 Weather: Sunny Truck Number: 9637 Concrete Temp (OF): 77 Batch Time: 6:26:00 AM Air Temp (OF): 80 Time Sampled: 7:00:00 AM Air Content: Elapsed Time (Min): 34 Cubic Yards Sampled: 20195 Unit Wt: Number of Cylinders Cast: 5 TEST RESULTS Curing (Days) TestDate Diameter (in) Area S in TotalLoad (lbs-force) CompressiveStrength (M) Break Type 7 7/31/2018 4.03 12.75 41430 3250 5 28 8/21/2018 3.99 12.5 60740 4860 5 28 8/21/2018 4.01 12.62 58830 4661 5 28 8/21 /2018 4.02 12.69 62280 4909 5 56 9/18/2018 0 Compressive Strength Average (PSI) of the 28 day Breaks = 4810 PASS No Other Breaks Evaluated DO D Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Reasonablywell- Well -formed cone on Columnervertical Diagonal fracture with Side fractures at top or Similar to type 5, but farmed cones on both one end,Vertical cracking through both no cracking through the bottom (Occurs cylinder is pointed. ends, less than 1 in. cracks running through ends, no well formed ends; tap with hammer commonly with (25 mm) of cracking raps, no wall -defined cones. to distinguish from type unbonded raps.) though caps. cone on other end. 1. " All dimensions and directions are approximate i . - I _ rr r,,,n.••�.,,,,, Checked By: William Martin Project Manager. - �- t I� L %`, �.•'��GENSF :,CGS t n y�i- SigrE OF fr axis ?OBIDP..Senior�Ef g F;odda LiSg.51E. ense fi`62- - /ONAL As a mutual protection to our client the public and ourselves, all reports are submitted as the confidential proper ofclients.1Awort ad04 for 9utitication of statements, conclusions, or extracts from our reports is reserved pendingwriften approval. Our reports apply only to the strengths of the test alpreimens and Ro; to the to-iim, strengths of the members indentified in the "Location' information. / I 1 i ATC Gf, Services LLC AVAkT 9955 N.W.116 Way Suite 1 Miami, FI.33178 N C TELEPHONE (305) 882.8200, FACSIMILE (305) 882-1200 L Compressive Strength Test of Concrete Cylinders Client Name: Wawa Inc. Date Cast: 7/24/2018 Project Name: Wawa Store #5220 Field Mark: JP-2 ProjectlD: 3996000423 Cylinder Set ID: 24596 Project Address: Prima Vista Blvd & Floresta Drive, Port St. Lucie Technician: Juan Paniagua Permit No.: Supplier: Cemex Sample Location: Slab N edge of slab between gridlines 3 & 4,14' of center of slab to North edge Remarks: Water Added FIELD DATA Design Strength (PSI:) 4000 Slump (In.): 6 Mix Description: 4k psi fiber Placement: Pump Ticket Number: 35841731 Weather: Sunny Truck Number: 9700 Concrete Temp ff): 78 Batch Time: 8:08:00 AM Air Temp ff): 81 Time Sampled: 9:00:00 AM Air Content: Elapsed Time (Min): 52 Cubic Yards Sampled: 70190 Unit Wt: Number of Cylinders Cast: 5 TEST RESULTS Curincl (Days) TestDate Diameter (in) Area S in TotalLoad (lbs-force) CompressiveStrenath (PSI) BreakTvpe 7 7/31/2018 4.02 12.69 42350 3338 5 28 8/21/2018 4.01 12.62 58300 4619 5 28 8/21/2018 3.99 12.5 61380 4911 2 28 8/21/2018 4.02 12.69 59750 4710 5 56 9/18/2018 0 Compressive Strength Average (PSI) of the 28 day Breaks = 4750 PASS No Other Breaks Evaluated Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Reasonably well- Well -formed cone on Columner vertical Diagonal fracture with Side fractures at top or Similar to type 5, but formed cones on both one end,Verticol cracking through both no cracking through the bottam.(Occurs cylinder is pointed. ends, less than 7 in. cracks running through ends, no well formed ends; tap with hammer commonlywilh (25 mm) of cracking caps, no well-defined nines, to distinguish from type unbonded caps.) though caps. cone on other end. 7. All dimensions and directions are approximate Checked By: William Martin Project Manager. LL�' Senior Enginear Fd�''�...... ' ���r,F �flodtl'a license#%,519 -;0NAL ENGn''' •....end As a mutual protection to our client the public and ourselves, all reports are submitted as the confidential propsrty'gf ciieiris. Autoritatlon for publication of statements, conclusions, or extracts from our reports is reserved pendingwdtten approval. Our reports apply only to the strengths of the test, specimens and not to Na I` N[u strengths of the members Indentifled In the "Location" Irdormation. / IF ATC G I Services LLC 9955 N.W.116 Way Suite 1 Miami, FI.33178 AV ITC TELEPHONE (305) 882-8200, FACSIMILE (305) 862-1200 MAk Compressive Strength Test of Concrete Cylinders Client Name: Wawa Inc. Date Cast: 7/25/2018 Project Name: Wawa Store #5220 Field Mark: JP-1 ProjectlD: 3996000423 Cylinder Set ID: 24597 Project Address: Prima Vista Blvd & Floresta Drive, Port St. Lucie Technician: Juan Paniagua Permit No.: Supplier: Cemex Sample Location: West fuel tank W of tank covers and S from last tank cover Remarks: FIELD DATA Design Strength (PSI:) 4000 Slump (In.): 3.5 Mix Description: 4000 psi & fiber Placement: Direct Ticket Number: 35844033 Weather: Sunny Truck Number: 9700 Concrete Temp ff ): 78 Batch Time: 6:21:00AM Air Temp ff): 80 Time Sampled: 7:20:00 AM Air Content: Elapsed Time (Min): 59 Cubic Yards Sampled: 20170 Unit Wt: Number of Cylinders Cast: 5 TEST RESULTS Curinq (Days) TestDate Diameter0n) Area S in Totall-oad (Ibs-force) CompressiveStrength (PSI) Break Type 7 8/1/2018 4.01 12.62 39360 3118 5 28, 8/22/2018 4.01 12.62 53920 4272 5 28 8/22/2018 4.03 12.75 55710 4370 5 28 8/22/2018 3.99 12.5 57810 4626 5 56 9/19/2018 0 Type 1 Reasonably well - formed cones on both ends, less than f in. (25 mm) of cracking though raps. Compressive Strength Average (PSI) of the 28 day Breaks = 4420 PASS No Other Breaks Evaluated N9 Type 2 Well -formed cone on one end,Verticol cracks running through caps, no well-defined cone on other end. ".All dimensions and directions are approximate Checked By: William Martin Type 3 columnar vertical cracking through both ends, no well farmed cones. Project Manager. Type 4 Diagonal fracture with no cracking through the ends; tap with hammer to distinguish from type 1. DE Type 5 Side fractures at top or bottom.(Occurs commonlywith unbonded caps.) Type 6 Similar to type 5, but cylinder is pointed. * f rE OF 3 ue (orb gtineeag-0,R.X 0,Fy*-. ORION Florida Licerise #,825ti3 o/ONAL ENG„r� As a mutual protection to our cllen% the public and ourselves, all reports are submitted as the confidential property, of clients. Automation for publication of statements, conclusions, or extracts from our reports Is reserved pendingwntten approval. Our reports apply only to the strengths of the test specimens/and not to the In -situ strengths of the members Indentined in the 'Location' Information. k ATC G, _, Services LLC ,' 9955 N.W.116 Way Suite 1 Miami, FI.33178 A C TELEPHONE (305) 882-8200, FACSIMILE (305) 882.1200 Compressive Strength Test of Concrete Cylinders Client Name: Wawa Inc. Date Cast: 7/25/2018 Project Name: Wawa Store #5220 Field Mark: Jp-2 ProjectlD: 3996000423 Cylinder Set ID: 24598 Project Address: Prima Vista Blvd & Floresta Drive, Port St. Lucie Technician: Juan Paniagua Permit No.: Supplier: Cemex Sample Location: Slab on grade West of fuel tanks slab from 25' N to 6' N of inlet C-4 Remarks: FIELD DATA Design Strength (PSI:) 4000 Slump (In.): 5.5 Mix Description: 4000 psi & fiber Placement: Direct Ticket Number: 35845071 Weather: Sunny Truck Number: 5756 Concrete Temp ff): 78 Batch Time: 9:41:00 AM Air Temp ('F): 89 Time Sampled: 11:10:00 AM Air Content: Elapsed Time (Min): 89 Cubic Yards Sampled: 60/70 Unit Wt: INumber of Cvlinders Cast: 5 Curino (Days) TestDate Diameter (in) Area S in TotalLoad (lbs-force) Compressivestrength (PSI) Break Tvpe 7 8/1/2018 4 12.56 37690 3001 5 28 8/22/2018 4.01 12.62 52510 4160 5 28 8/22/2018 4 12.56 56940 4533 5 28 8/22/2018 4.02 12.69 55660 4388 5 56 9/19/2018 0 Compressive Strength Average (PSI) of the 28 day Breaks = 4360 PASS No Other Breaks Evaluated Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Reasonably well- Well -formed cone an Columnar vertical Diagonal fracture with Side fractures at tap or Similar to type 5, but formed cones on both one encNertical cracking through both no cracking through the bottom. (Occurs cylinder is pointed.. ends, less than 1 in. cracks running through ends, no well fanned ends; tap with hammer commonly with (25 mm) of cracking caps, no well-defined canes. to distinguish from type unbonded caps.) though caps. cone on other end. 1. All dimensions and directions are approximate ............... Checked By: William Martin ProjectManager. 7C/ _� c „ --. ' �,` �.\CENgF;:�4� Iti -t: moo`: STATE OF senior t:nglneer ''.°S/pNAL.... c,Florida2icgRse#62519 11 ..r As a mutual protection to our client, the public and ourselves, all reports are submitted as the confidential property of clients. A itorl ation fpr publication of statements, conclusions, of extracts from our reports is reserved pendingwdlten approval. Our reports apply only to the strengths of the teSt,specimens and not :6 the in -situ strengths of the members indentified in the "Location" information. t JSCANNEDBY ATC Group Services LLC 9955 N.W.116 Way Suite 1 Miami, FI.33178 TELEPHONE (305) 882-8200, FACSIMILE (305) 882-1200 I Compressive SSVerhff T6%T`bf Concrete Cy Client Name: Wawa Inc. Date Cast: Project Name: Wawa Store #5220 Field Mark: ProjectlD: 3996000423 Cylinder Set ID: Project Address: Prima Vista Blvd & Floresta Drive, Port St. Lucie Technician: Permit No.: Supplier: Sample Location: Canopy footings (D,3)+ (A,2) 30% Remarks: FIELD DATA linders 4/19/2018 AM-1 23989 Ahmed Mokhtar ceT_qK'Aquno: @pr, ..c 4u@w4jedaq buipjw-,;),j I 910z e 9 911d I I Design Strength (PSI:) 4000 Slump (In.): Up i Assat ttr',r,.: Mix Description: CAJ25R10 4000 #57 Placement: Fully Ticket Number: 35656234 Weather: Sunny Truck Number: 65283 Concrete Temp (°F): 79 Batch Time: 11:37:00 AM Air Temp (°F): 82 Time Sampled: 12:15:00 PM Air Content: Elapsed Time (Min): 38 Cubic Yards Sampled: 10.5178.5 Unit Wt: Number of Cylinders Cast: 5 TEST RESULTS Curinc (Days) TestDate Diameter (in) Area (Sci in Totall-oad (lbs-force) CompressiveStrenoth (PSI) Break Type 7 4/26/2018 4.02 12.69 46520 3667 2 28 5/17/2018 4.03 12.75 64670 5073 2 28 5/17/2018 4 12.56 64790 5158 2 28 5/17/2018 4.01 12.62 64420 5103 5 56 5/17/2018 0 Compressive Strength Average (PSI) of the 28 day Breaks = 5110 PASS No Other Breaks Evaluated Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Reasonablywell- Well -formed cone on Columnervertical Diagonal fracture with Side fractures at top or Similar to type S. but fanned cones on both one enc Nerfical cracking through both no trading through the bottom.(Occurs cylinder is pointed. ends, less than 1 in. cracks running through ends, no well fanned ends; tap with hammer commonly with (25 mm) of cracking caps, no welldefned cones. to daMiguish torn type unbonded raps.) though caps. cone on other end. t. " All dimensions and directions are approximate Checked Bym: WilliaMartin Project Manager.!f+h" r' h iH' }aa ex� Semen Efgineer _ Fyn, '-••••-^^''�yt• FWdeti.,Llegifs..�E251B, +�NALE� ,d 47 F1 LE As a mutual protection to our client, the public and ourselves, all reports are submitted as the confidential pisperby of clients. Autoriration for publication of statements, conclusions, or etdmCS from our reports Is reserved penditt ingwi en approval. Our reports apply only to the strengths of the test specimens and not to the In situ strengths of the members Indentified In Me Z.catlon" information. _ ATC Group Services LLC 9955 N.W.116 Way Suite 1 Miami, FI.33178 TELEPHONE (305) 882-8200, FACSIMILE (305) 882-1200 Compressive Strength Test of Concrete Cylinders Client Name: Wawa Inc. Date Cast: 4/19/2018 Project Name: Wawa Store #5220 Field Mark: AM-2 ProjectlD: 3996000423 Cylinder Set ID: 23990 Project Address: Prima Vista Blvd & Floresta Drive, Port St. Lucie Technician: Ahmed Mokhtar Permit No.: Supplier: Cemex Sample Location: Canopy Footing (D,1)+(1,C) 70% Remarks: FIELD DATA Design Strength (PSI:) 4000 Slump (In.): 6 Mix Description: CAJ25R1 0 4000 #57 Placement: Pump Ticket Number: 35656537 Weather: Sunny Truck Number: 25403 Concrete Temp (°F): 80 Batch Time: 1:09:00 PM Air Temp (eF): 83 Time Sampled: 1:40:00 PM Air Content: Elapsed Time (Min): 31 Cubic Yards Sampled: 63.5/78.5 Unit Wt: Number of Cylinders Cast: 5 TEST RESULTS Curing (Days) TestDate Diameter (in) Area S in Totall-oad (lbs-force) CompressiveStrength (PSI) Break Type 7 4/26/2018 4.03 12.75 41000 3216 5 28 5/17/2018 3.99 12.5 61250 4901 2 28 5/17/2018 4.02 12.69 61600 4856 2 28 5/17/2018 4 12.56 63240 5035 2 56 5/17/2018 0 Compressive Strength Average (PSI) of the 28 day Breaks = 4930 PASS No Other Breaks Evaluated Type 1 Type 2 Type 3 Type 4 Reasonablywell- Well-fonnel cone on ColumnerveNcal Diagonal fracture with formed cones on both one enc Nertical craddng through bath no craceng through the entls, less than 1 in. cracks running through ends, no well formed ends; tap with hammer (25 mm) of cracking caps, no well-defined canes. to distinguish from type though caps. cone on other end. 1. a` All dimensions and directions are approximate `Checked By: William Martin Project Manager. � r. Du P Type 5 Type 6 Side fractures at top or Similar to type 5, but bottom. (Occurs cylinder is pointed. commonly with unbonded caps.) AfCrd�s,`e Lil'gLA F. r- a'O,� �-.a8I0A�4� Semor Eci9iiteer ;3� �... Rtsnda.Ll?iis?:i!b2579-_:yQNNAIEWt As a mutual protection to our client the public and ourselves, all reports are submitted as the confidential propegv of clle'ta:Autm!za lm, fer publication of statements, conclusions, or extracts fmm our reports is reserved pendingwriften approval. Our reports apply only to Me sfrengNs of the tesi speetn�ens and not to the In -situ strengths of the members Indentified in the Zacagen' information. , ,, ATC Group Services LLC 1, 9955 N.W.116 Way Suite 1 Miami, FI.33178 r TELEPHONE (305) 882-8200, FACSIMILE (305) 882.1200 Compressive Strength Test of Concrete Cylinders Client Name: Wawa Inc. Date Cast: 4/26/2018 Project Name: Wawa Store #5220 Field Mark: AM-1 ProjectlD: 3996000423 Cylinder Set ID: 24014 Project Address: Prima Vista Blvd & Floresta Drive, Port St. Lucie Technician: Ahmed Mokhtar Permit No.: Supplier: Cemex Sample Location: Piers of Canopy Footing along Line 1 & (A,B,C,D) Remarks: FIELD DATA Design Strength (PSI:) 4000 Slump (In.): 6 Mix Description: 4000 Regular Placement: Steel Container Ticket Number: 35670814 Weather: Sunny Truck Number: 22607 Concrete Temp (OF): 80 Batch Time: 12:11:00 PM Air Temp (OF): 82 Time Sampled: 12:55:00 PM Air Content: Elapsed Time (Min): 44 Cubic Yards Sampled: 10/20 Unit Wt: Number of Cylinders Cast: 5 TEST RESULTS Curing (Days) TestDa a Diameter (in) Area (Sq in TotalLcad (lbs-ford CompressiveStrenoth (PSI) BreakTvoe 7 5/3/2018 4.01 12.62 52440 4154 2 28 5/24/2018 3.99 12.5 71430 5716 2 28 5/24/2018 4 12.56 68470 5451 5 28 5/24/2018 4.03 12.75 69280 5434 3 56 6/21/2018 0 Compressive Strength Average (PSI) of the 28 day Breaks = 5530 PASS No Other Breaks Evaluated —+I Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Reasonably well- Well -formed cone on Culumnerverlical Diagonal fracture with side fractures at top or Similar to type 5, but formed cones on bath one end,Vertical cranking Ihmugh both no cracking through the batten (Occurs cylinder is pointed. ends, less than 1 in. cracks running through ends, no well formed ends; lap with hammer commonlywith (25 mm) of cracking raps, no well-defined cones, to distinguish from type unbonded caps.) though caps. cone on other end. 1. •' All dimensions and directions are approximate Checked By: William Martin Project Manager. �� As a mutual protection to our clien%the public and ourselves, all reports are submitted as the confidential property of clienbi: Autod titlon for publie2tion of statements, conclusions, or extracts from our reports is reserved pendingwritten approval. Our reports apply only to the strengths of the test specimerio and not to the In-sltu'stmngths of the members Indentiged In the "Location" Information. Ii ATC Group Services LLC At 9955 N.W.116 Way Suite 1 Miami, FI.33178 XC TELEPHONE (305) 882-8200, FACSIMILE (305) 882.1200 'T Compressive Strength Test of Concrete Cylinders Client Name: Wawa Inc. Date Cast: 5/15/2018 Project Name: Wawa Store #5220 Field Mark: EM-1 ProjectlD: 3996000423 Cylinder Set ID: 24193 Project Address: Prima Vista Blvd & Floresta Drive, Port St. Lucie Technician: Emmanuel Monuma Permit Ni Supplier: Cemex Sample Location: Building Slab:(15, 12.5), (K,F) Remarks: Slump was measured at the pump FIELD DATA Design Strength (PSI:) 4000 Slump (In.): 7 Mix Description: 1603448 Placement: Pump Ticket Number: 35706199 Weather: Mostly Cloudy Truck Number: 7678 Concrete Temp (°F): 62 Batch Time: 6:41:00AM Air Temp ff): 72 Time Sampled: 7:18:00 AM Air Content: Elapsed Time (Min): 37 Cubic Yards Sampled: 101115 Unit Wit: Number of Cylinders Cast: 5 TEST RESULTS 1 Curing (Days) Tes Date Diameter lint Area S in TotalLoad (lbs-force) CompressiveStrencith (PSI) Break Type 7 5/22/2018 3.99 12.5 49700 3977 5 28 6/12/2018 4.03 12.75 75120 5892 5 28 6/12/2018 4.02 12.69 74770 5894 4 28 6/12/2018 4.01 12.62 72880 5774 5 56 7/10/2018 0 Compressive Strength Average (PSI) of the 28 day Breaks = 5850 PASS No Other Breaks Evaluated Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Reasonablywell- Well4crned cone on Columnerve,tical Diagonal fracture with Side fractures at top or Similar to type 5, but formed cones on both one end.Vencal cradang through bath no cracidng through the bottom (Occurs cylinder is pointed. ends, less than l in. cracks running through ends, no well farmed ends: tap with harsher commonly with (25 roll of cracking naps, nowell4efined cones. to distinguish from type unbonded caps.) though caps. cone on other end. 1. "All dimensions and directions are approximate Checked By: William Martin Project Manager. As a mutual pmteclion to our client, the public and ourselves, all reports are submitted as the conndenM extracts from our reports Is reserved pendingwdtten approval. Our reports apply only to the strengths of In the "Location"Information. stone, or :dined