HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE�• ' t'JT == + Planning & Development Services Department
• Building & Code Regulations Division
-- 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
J�gy ED
Sands I Condominium - Concrete Restoration fit. �U�"z (?
Project Name: ()llnfV
Project Address: 3210 South Lakeview Circle (Building 3), Fort Pierce, Florida
Permit#: 1704-0512 Occupancy Type: R-2 Construction Type:VB
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida FBCEB Code Fifth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B C X D
4. Design Wind Velocity 161 mph _ASO X LRFD End Zone Width: 5 ft
5. Mean Roof Height 25 ft Roof Pitch: 5 :12 Parapet: - ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +261-41 Zone 2: +26/-71 Zone 3: +26/-105 Zone 4: +45/-49 Zone 5: +45/-60 Garage: N/A
7. Design Loads: Floor: 40 PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: Bo PSF
Dock: - PSF Deck: " PSF Stairs: 100 PSF Fence:- PSF Railings: PSF
8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not:
No, work to done on existing sheanvalls; No changes to shearwalls.
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? _Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:VF 0 I V14 7//// Rodolfo Villamizar, P.E. - 61000 & SI #7021620
Vlc Eiy' ";teice Print Name Cert#&Co. Cert Auth.
�No. Ginny MBV Engineering, Inc.
V a r Il
signature; e, an §gy,
i T E OF % 7
%P ..,ORION
���
Revised 07/2 yrzbNAL ENG\ \\
/////IIIIIII\\��
1835 20th Street, Vero Beach, FL 32960
Company Name & Address
1-1
2
S�iL4' • �: - � ice.., --.-'a
Planning & Development Services,, .,artment
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553
Certification for Design Load Compliance
Project Name: The Sands Section 1 - Building 3 (Structural Repairs)
Project Address: 3210 South Lakeview Circle Fort Pierce, FL 34949
J�By ED
St t(ICio n_
Permit #: Occupancy Type: R-2 Construction Type: I I
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D
4. Design Wind Velocity 132 mph X ASD _LRFD End Zone Width: 7 ft
5. Mean Roof Height <25
Roof Pitch: 5 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +24/-39 Zone 2: +241-67 Zone 3: +241-100 Zone 4: +421-46 Zone 5: +42/-57 Garage: N/A
7. Design Loads: Floor: NIA PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: 60P-> PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: NIA PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Si nature, Date, and Seal
Michael A. Lue, P.E.
Print Name
M L Engineering, Inc
47520
Cert # & Co. Cert Auth.
2030 37th Ave Vero Beach, FL 32960
Company Name & Address
Revised 07/25/,2014
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-15. 35GANNED
BY
Certification for Design Load Compliance St. lllriP ( minty
Project Name: The Sands Section 1 - Building 3 (Structural Repairs)
Project Address: 3210 South Lakeview Circle Fort Pierce, FL 34949
Permit#: Occupancy Type: R-2 Construction Type: 11
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition 9LE
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D
4. Design Wind Velocity t32 mph X ASO LRFD End Zone Width: 7 ft
5. Mean Roof Height ` 25 ft Roof Pitch: 5 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +241-39 Zone 2: +24/-67 Zone 3: *241-100 Zone 4: +42/-46 Zone 5: +42/-57 Garage: N/A
7. Design Loads: Floor: N/A PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: ON-) PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? _Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces spcecified;
Michael A. Lue, P.E. 47520
Si nature, Date, and Seal
Print Name
M L Engineering, Inc
Cert # & Co. Cert Auth.
2030 37th Ave Vero Beach, FL 32960
Company Name & Address
Revised 07/25/2014