HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE�• ' t'JT == + Planning & Development Services Department • Building & Code Regulations Division -- 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance J�gy ED Sands I Condominium - Concrete Restoration fit. �U�"z (? Project Name: ()llnfV Project Address: 3210 South Lakeview Circle (Building 3), Fort Pierce, Florida Permit#: 1704-0512 Occupancy Type: R-2 Construction Type:VB INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida FBCEB Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B C X D 4. Design Wind Velocity 161 mph _ASO X LRFD End Zone Width: 5 ft 5. Mean Roof Height 25 ft Roof Pitch: 5 :12 Parapet: - ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +261-41 Zone 2: +26/-71 Zone 3: +26/-105 Zone 4: +45/-49 Zone 5: +45/-60 Garage: N/A 7. Design Loads: Floor: 40 PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: Bo PSF Dock: - PSF Deck: " PSF Stairs: 100 PSF Fence:- PSF Railings: PSF 8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not: No, work to done on existing sheanvalls; No changes to shearwalls. 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? _Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified:VF 0 I V14 7//// Rodolfo Villamizar, P.E. - 61000 & SI #7021620 Vlc Eiy' ";teice Print Name Cert#&Co. Cert Auth. �No. Ginny MBV Engineering, Inc. V a r Il signature; e, an §gy, i T E OF % 7 %P ..,ORION ��� Revised 07/2 yrzbNAL ENG\ \\ /////IIIIIII\\�� 1835 20th Street, Vero Beach, FL 32960 Company Name & Address 1-1 2 S�iL4' • �: - � ice.., --.-'a Planning & Development Services,, .,artment Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 Certification for Design Load Compliance Project Name: The Sands Section 1 - Building 3 (Structural Repairs) Project Address: 3210 South Lakeview Circle Fort Pierce, FL 34949 J�By ED St t(ICio n_ Permit #: Occupancy Type: R-2 Construction Type: I I INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D 4. Design Wind Velocity 132 mph X ASD _LRFD End Zone Width: 7 ft 5. Mean Roof Height <25 Roof Pitch: 5 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +24/-39 Zone 2: +241-67 Zone 3: +241-100 Zone 4: +421-46 Zone 5: +42/-57 Garage: N/A 7. Design Loads: Floor: NIA PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: 60P-> PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: NIA PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Si nature, Date, and Seal Michael A. Lue, P.E. Print Name M L Engineering, Inc 47520 Cert # & Co. Cert Auth. 2030 37th Ave Vero Beach, FL 32960 Company Name & Address Revised 07/25/,2014 Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-15. 35GANNED BY Certification for Design Load Compliance St. lllriP ( minty Project Name: The Sands Section 1 - Building 3 (Structural Repairs) Project Address: 3210 South Lakeview Circle Fort Pierce, FL 34949 Permit#: Occupancy Type: R-2 Construction Type: 11 INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition 9LE o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D 4. Design Wind Velocity t32 mph X ASO LRFD End Zone Width: 7 ft 5. Mean Roof Height ` 25 ft Roof Pitch: 5 :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +241-39 Zone 2: +24/-67 Zone 3: *241-100 Zone 4: +42/-46 Zone 5: +42/-57 Garage: N/A 7. Design Loads: Floor: N/A PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: ON-) PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? _Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces spcecified; Michael A. Lue, P.E. 47520 Si nature, Date, and Seal Print Name M L Engineering, Inc Cert # & Co. Cert Auth. 2030 37th Ave Vero Beach, FL 32960 Company Name & Address Revised 07/25/2014