HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services ,cpartment
'I Building & Code Regulations Division
y I.'L- i L41,L1.i�,a
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance ovruVNED
Project Name: The Sands Section 1 - Building 5 (Structural Repairs) BY
. Lucie countv
Project Address: 3216 South Lakeview Circle Fort Pierce, FL 34949
Permit #: Occupancy Type: R-2 Construction Type: II
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D
4. Design Wind Velocity 132 mph x ASO _LRFD End Zone Width: 7 ft
5. Mean Roof Height < 25 ft Roof Pitch: 5 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +2409 Zone 2: +241-67 Zone 3: +24t-100 Zone 4: +42146 Zone 5: +421-57 Garage: N/A
7. Design Loads: Floor: N/A PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: BOW-) PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? x Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Michael A. Lue, P.E. 47520
signature, Date, and Seal
Print Name
M L Engineering, Inc
Cert # & Co. Cert Auth.
2030 37th Ave Vero Beach, FL 32960
Company Name & Address
Revised 07/25/2014
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 OUAINNEb
BY
Certification for Design Load Compliance �f ( 116,3Cnjinh,
Project Name: Sands I Condominium - Concrete Restoration
Project Address: 3216 South Lakeview Circle (Building 5), Fort Pierce, Florida
Permit #: 1704-0515 Occupancy Type: R-2 Construction Type:VB
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida FBCEB Code Fifth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D
4. Design Wind Velocity 161 mph _ASD X LRFD End Zone Width: 5 ft
5. Mean Roof Height 25 ft Roof Pitch: 5 :12 Parapet: - ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +26/-41 Zone 2: +26/-71 Zone 3: +261-105 Zone 4: +45/49 Zone 5: +45/-60 Garage: N/A
7. Design Loads: Floor: 40 PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: 60 PSF
Dock: - PSF Deck: - PSF Stairs: 100 PSF Fence:- PSF Railings: PSF
8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not:
No, work to done on existing sheanwalls; No changes to sheanvalls.
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not
10. Design Soil Bearing Pressure: WA PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify t%\b�e fs Y/p� knowledge and belief, the attached plans & specifications have been designed to
Comply�viti �leFa�' {E :a uf�ral portions of the building codes currently adopted and enforced by St. Lucie
Count' to tc certify th U�tYu�t, tr�L elements depicted on these plans provide adequate resistance to the design
forcessV ffieclNo. 61000 `13
UTE
Rodolfo Villamizar, P.E. 61000 & SI #7021620
OF ,�Print Name Cert # & Co. Cert Auth.
10
4 -�� MBV Engineering, Inc.
Signature, a/f@ pr� �100' 1835 20th Street, Vero Beach, FL 32960
Company Name & Address
Revised 07/25/2014
fth
Planning & Development Services Department
IV Building & Code Regulations Division
2300Virginia Avenue, Fort Pierce, FL 34982 — (772)"WkL
BY
Certification for Design Load Complianc�t- I_1,16A f'nnnfi
Project Name: The Sands Section 1 - Building 5 (Structural Repairs)
Project Address: 3216 South Lakeview Circle Fort Pierce, FL 34949
Permit#: Occupancy Type: R-2 Construction Type: 11
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single ormulti-family)
o Residential Addition 10
o Any accessory structure requiring a building permit F I L h C 0
o Any non-residential structure.
• Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D
4. Design Wind Velocity 132 mph X ASD _LRFD End Zone Width: 7 ft
5. Mean Roof Height ` 25 ft Roof Pitch: 5 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +24/-39 Zone 2: +24/-67 Zone 3: +24/-100 Zone 4: +42/-46 Zone 5: +42/-57 Garage: N/A
7. Design Loads: Floor: N/A PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: W(U.) PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? _Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Michael A. Lue, P.E. 47520
Sig ature, Date, and Seal
Print Name
M L Engineering, Inc
Cert # & Co. Cert Auth.
2030 37th Ave Vero Beach, FL 32960
Company Name & Address
x-