HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 6GANNED
By
Certification for Design Load Compliance St. Luce Ca1nh7
Project Name: Sands I Condominium - Concrete Restoration
Project Address: 3212 South Lakeview Circle (Building 10), Fort Pierce, Florida
Permit#: 1704-0525 Occupancy Type: R-2 Construction Type:VB
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida FBCEB Code Fifth Edition with 20 17 Supplements using ASCE 7-10
2, Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D
4. Design Wind Velocity 161 mph _ASD X LRFD End Zone Width: 5 ft
5. Mean Roof Height 25 ft Roof Pitch: 5 :12 Parapet: - ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +26/-41 Zone 2: +26/-71 Zone 3: +26/-106 Zone 4: +45/-49 Zone 5: +45/-60 Garage: N/A
7. Design Loads: Floor: 40 PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: 60 PSF
Dock: - PSF Deck: - PSF Stairs: 100 PSF Fence:- PSF Railings: PSF
8. Were Shear Walls Considered For Structure? _Yes x Not Applicable Explain Why Not:
No, work to done on existing shearwalls; No changes to shearwalls.
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? _Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also ce i \tNNUdYgmal elements depicted on these plans provide adequate resistance to the design
forcesspecifi4\�,p VILL,q�/
All
Rodolfo Villamizar, P.E. 61000 & SI #7021620
61000 Print Name Cert ft& Co. Cert Auth.
MBV Engineering, Inc.
signature' hd SFaI _.
SIOFIP\-��?
Revised 07/25/201/ // / I I I I I I\ \ \\\
1835 20th Street, Vero Beach, FL 32960
Company Name & Address
v:Y �
r
t
Om�
'�'f +Planning & Development Services Department
x, 'r r Building &Code Regulations Division
' r7
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: The Sands Section 1 - Building 10 (Structural Repairs)
Project Address: 3212 South Lakeview Circle
Fort Pierce, FL 34949
Permit #: Occupancy Type: R-2 Construction Type: Ii
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building
Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one):
X Enclosed _Partially Enclosed
_Open
3. Risk Category: _I X II _III
IV Exposure Category: _B X
C _D
4. Design Wind Velocity 732
mph X ASD _LRFD End Zone Width:
7 ft
5. Mean Roof Height < 25
ft Roof Pitch: 5 :12 Parapet:
N/A ft.
6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +241-39 Zone 2: +24/-57 Zone 3: +24/-100 Zone 4: +421-46 Zone 5: +421-57 Garage: N/A
7. Design Loads: Floor: N/A PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: 60(LW) PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? _Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Michael A. Lue, P.E. 47520
Signature, Date, and Seal
Print Name
M L Enqineerinq, Inc
Cert # & Co. Cert Auth.
2030 37th Ave Vero Beach, FL 32960
Company Name & Address
Revised 07/25/2014
r5� Planning & Development Services Department \
o, Building & Code Regulations Division
230D Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: The Sands Section 1 - Building 10 (Structural Repairs)
Project Address: 3212 South Lakeview Circle Fort Pierce, FL 34949
Permit #: Occupancy Type: R-2 Construction Type: II
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit ILE
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D
4. Design Wind Velocity 132 mph X ASD _LRFD End Zone Width: 7 ft
5. Mean Roof Height ' 25 ft Roof Pitch: 5 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings)
Zone 1: +241-39 Zone 2: +24/-67 Zone 3: +241-100 Zone 4: +421-46 Zone 5: +42/-57 Garage: NIA
7. Design Loads: Floor: N/A PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: way: PSF
Dock: NIA PSF Deck: N/A PSF Stairs: NIA PSF Fence: N/A PSF Railings: NIA PSF
8. Were Shear Walls Considered For Structure? N Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
AA _
l G%�
Signature, Date, and Seal
Michael A. Lue, P.E. 47520
Print Name
M L Engineering, Inc
Cert # & Co. Cert Auth.
2030 37th Ave Vero Beach, FL 32960
Company Name & Address
Revised 07/25/2014