HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: Sands I Condominium - Concrete Restoration
Project Address: 3215 South Lakeview Circle (Building 12), Fort Pierce, Florida
Permit #: 1704-0529 Occupancy Type: R-2 Construction Type: VB
6L ANNED
BY
St. Lucie county
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida FBCEB Code Fifth Edition with 20 17 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B _C X D
4. Design Wind Velocity 161 mph _ASD X LRFD End Zone Width: 5 ft
S. Mean Roof Height 25 ft Roof Pitch: 5 :12 Parapet: - It
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +26/-41 Zone 2: +261-71 Zone 3: +26/-105 Zone 4: +45/-49 Zone 5: +45/-60 Garage: N/A
7. Design Loads: Floor: 40 PSF Roof/Dead: 20 PSF Roof/Live:.20 Balcony: 60 PSF
Dock: - PSF Deck: - PSF Stairs: 100 PSF Fence:- PSF Railings: PSF
8. Were Shear Walls Considered For Structure? _Yes X Not Applicable Explain Why Not:
No, work to done on existing sheamalls; No changes to shearwalls.
9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not
10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, \0 I I wledge and belief, the attached plans & specifications have been designed to
comply wit1k3XWbel-1 caVblsEa1�ortions of the building codes currently adopted and enforced by St. Lucie
County. Lat igrt /hat s�truc 4, F%nents depicted on these plans provide adequate resistance to the design
forces sp_ecityi: 61000
NO' — Rodolfo Villamizar, P.E. 61000 & SI #7021620
' W — Print Name Cent# & Co. Cent Auth.
STTSOF ;?�
MBV Engineering, Inc.
PIL
Signature, �4PI N11P1�� a 1835 2Oth Street, Vero Beach, FL 32960
Company Name & Address
Revised 07/25/2014
Planning & Development Services Department
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: The Sands Section 1 - Building 12 (Structural Repairs)
Project Address: 3215 South Lakeview Circle
Fort Pierce, FL 34949
Permit#: Occupancy Type: R-2 Construction Type: II
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D
4. Design Wind Velocity 132 mph X ASO _LRFD End Zone Width: 7 ft
5. Mean Roof Height ` 25 ft Roof Pitch: 5 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +241-39 Zone 2: +241-67 Zone 3: +241-100 Zone 4: +42/-46 Zone 5: +421-57 Garage: N/A
7. Design Loads: Floor: N/A PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony: W(LNi PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: NIA PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
Michael A. Lue, P.E. 47520
-Sigi ature, Date, and Seal
Print Name
M L Engineering, Inc
Cert # & Co. Cart Auth.
2030 37th Ave Vero Beach, FL 32960
Company Name & Address
Revised 07/25/2014
Jjja-~% Planning & Development Services Department
,y alm
Building & Code Regulations Division
2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553
Certification for Design Load Compliance
Project Name: The Sands Section 1 - Building 12 (Structural Repairs)
Project Address: 3215 South Lakeview Circle Fort Pierce, FL 34949
Permit #:
Occupancy Type: R-2 Construction Type: II
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition Py
o Any accessory structure requiring a building permit F I LEE` DO
o Any non-residential structure.
* Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Building Code Fifth Edition with 20 14 Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D
4. Design Wind Velocity 132 mph X ASD _LRFD End Zone Width: 7 ft
5. Mean Roof Height < 25 ft Roof Pitch: 5 :12 Parapet: N/A ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: +24/-39 Zone 2: +24/-67 Zone 3: +24/-100 Zone 4: +42/-46 Zone 5: +42/-57 Garage: N/A
7. Design Loads: Floor: N/A PSF Roof/Dead: 20 PSF Roof/Live: 20 Balcony:. 6Ma) PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: N/A PSF Soil Test Reports Submitted? Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
0
Sig ature, Date, and -Seal
Michael A. Lue, P.E. 47520
Print Name
M L Engineering, Inc
Cert # & Co. Cert Auth.
2030 37th Ave Vero Beach, FL 32960
Company Name & Address
Revised 07/25/2014