Loading...
HomeMy WebLinkAboutNOAMIALMI'MIR ma SCANNtij BY St•LUCie rnrinf DEPARTMENT OF REGULATORY AND ECONOJffC RESOURCES (MR) BOARD AND CODE ADIMNISTRATIONDMSION NOTICE OF ACCEPTANCE (NOA) Firestone Building Products Company, LLC 250 W. 96`s Street Indianapolis, IN 46260 IMAW-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 Miami, Florida 33175-2474 T (786)315-2590 F (786) 315-2599 immroiamidadc.eor/r onoroy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami Dade County RER - Product Control Section to be used in Miami -Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami Dade County Product Control Section (in Miami -Dade County) and/or the AHJ (in areas other than Miami -Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Firestone Modified Bitumen Roof Systems over Concrete Decks. LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process_ Misuse of this NOA as`an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. ]INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA No. 15-0224.09 and consists of pages 1 through 135. The submitted documentation was reviewed by Alex Tigera. apswaftlem �.. APPROVED NOA No.: 16-0202.10 Expiration Date: 03/08/21 Approval Date: 03/24/16 Page 1 of 135 ROOFING SYSTEM APPROVAL Cateeorv' Roofing Sub -Category: Modified Bitumen Material: APP/SBS Deck Type: Concrete Maximum Design Pressure: -547.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Test Product Product Dimensions Specification Description APP 80 Glass Base 39.4" x 654" ASTM D6509 Fiberglass reinforced modified bitumen, smooth surfaced base sheet. SBS Glass Torch Base 39.4" x 3310" ASTM D6163 Modified bitumen base sheet with a bum -off film and reinforced with non -woven fiberglass mat. SBS Base 39.4" x 50' ASTM D6163 Fiberglass reinforced SBS base sheet. Applied in hot asphalt or mechanically attached. SBS Premium Base 39.6" x 50' ASTM D6163 Fiberglass reinforced SBS base sheet. Applied in hot asphalt or Multi -Purpose MB Cold Adhesive. SBS PolyBase 39.6" x 50' ASTM D6164 A smooth surfaced, non -woven polyester reinforced, modified bitumen base sheet. SBS Poly Torch Base 45" x 39" ASTM D6164 Fiberglass reinforced' modified bitumen membrane, SBS rubber modified asphalt reinforced with a non -woven polyester mat 3Ply IV 33" x 180" ASTM D2178 Fiberglass reinforced, asphalt impregnated, roofing ply. Applied in hot asphalt, Ply VI 33" x 180" ASTM D2178 Fiberglass reinforced, asphalt impregnated, roofing ply. Applied in hot asphalt. I MB Base / 36" x 108' ASTM D4601 Fiberglass reinforced base sheet, asphalt coated on both sides. Applied in hot asphalt or mechanically attached. SBS Smooth 39.4" x 33'10" ASTM D6164 Smooth surfaced, modified bitumen membrane reinforced with non -woven polyester mat. Applied in hot asphalt. APP 160-P 39.4" x 32'9" ASTM D6222 Polyester reinforced modified bitumen, smooth surfaced membrane. Torch applied for use as a base or ply sheet only. APP 170 Cool 39.6" x 33'6" ASTM D6222 Polyester reinforced modified bitumen, smooth surfaced membrane. APP I80 39.4" x 32'10" ASTM D6222 Polyester reinforced modified bitumen, granule surfaced membrane. Torch applied. FILE CQPY.2.10 Expiration Date: 03/08/21 Approval Date: 03/24/16 Page 2 of 135 APP 180-P 39.4" x 32'9" ASTM D6222 Polyester reinforced modified bitumen, granule surfaced membrane. Torch applied. APP 180 UltraWhite 39.4" x 32'10" ASTM D6222 Polyester reinforced modified bitumen, UltraWhite granule surfaced membrane. Torch applied. APP 180 FR 39.4" x 32'10" ASTM D6222 Polyester reinforced, fire retardant modified bitumen, granule surfaced membrane. Torch applied. APP 180 FR 39A" x 32'10" ASTM D6222 Polyester reinforced, fire retardant modified UltraWhite bitumen, UltraWhite granule surfaced membrane. Torch applied. APP 180 Cool 39.4" x 3T10" ASTM D6222 Polyester reinforced modified bitumen, granule surfaced membrane. APP 180 FR Cool 39.4" x 32'l0" ASTM D6222 Polyester reinforced, fire retardant modified bitumen, granule surfaced membrane. Torch applied. SBS Glass 39.4" x 33'10" ASTM D6163 Fiberglass reinforced, granule surfaced, modified bitumen membrane. Applied in hot asphalt. (04- SBS Glass FR -- 39.4" x 33'10" ASTM D6163 Fiberglass reinforced, fire rated, granule surfaced, modified bitumen membrane. Applied in hot asphalt. SBS Glass FR 39.4" x 33'l0" ASTM D6163 UltraWhite fiberglass reinforced, granule UltraWhite surfaced, modified bitumen membrane. Applied in hot asphalt. SBS Torch 48" x 39" ASTM D6164 Granule surfaced, SBS cap reinforced with a non- woven polyester mat, with bum off film and fiberglass enhanced. SBS Torch UltraWhite 48" x 39" ASTM D6164 UltraWhite granule surfaced, SBS cap reinforced with a non -woven polyester mat, with burn off film and fiberglass enhanced. SBS FR Torch 48" x 39" ASTM D6164 Granule surfaced, fire rated, SBS cap reinforced with a non -woven polyester mat, with burn off film and fiberglass enhanced. SBS FR Torch 48" x 39" ASTM D6164 UltraWhite granule surfaced, fire rated, SBS cap UltraWhite reinforced with a non -woven polyester mat, with bum off film and fiberglass enhanced. SBS Glass FR Torch 39.4" x 33'10" ASTM D6163 Fiberglass reinforced, fire rated, granule surfaced, modified bitumen membrane. with bum off film and fiberglass enhanced. SBS Glass FR Torch 39.4" x 33'l0" ASTM D6163 UltraWhite fiberglass reinforced, fire rated, UltraWhite granule surfaced, modified wbitum Linwribrane. with bu ff JW arC It ed. NOA No.: 16-0202.10 Expiration Date: 03/08/21 Approval Date: 03/24/16 Page 3 of 135 SBS Cap 39.4" x 33'10" ASTM D6164 Granule surfaced, modified bitumen membrane reinforced with non -woven polyester mat SBS Cap UltraWhite 39.4" x 33'10" ASTM D6164 U1traVJhite granule surfaced, modified bitumen membrane reinforced with non -woven polyester mat. SBS FR Cap 39.4" x 33'10" ASTM D6164 Granule surfaced, modified bitumen membrane reinforced with non -woven polyester mat. SBS FR Cap 39.4" x 33'10" ASTM D6164 UltraWhite granule surfaced, modified bitumen UltraWhite membrane reinforced with non -woven polyester mat. SBS Premium FR 39.4" x 3TI0" ASTM D6164 Granule surfaced, fire rated, modified bitumen membrane reinforced with non -woven polyester mat. SBS Premium FR 39.4" x 33'10" ASTM D6164 UltraWhite granule surfaced, fire rated, modified UltraWhite bitumen membrane reinforced with non -woven polyester mat_ SBS Premium 39A" x 33'10" ASTM D6164 Granule surfaced, modified bitumen membrane reinforced with polyester mat. Applied in hot asphalt. SBS Premium Torch 39.4" x 33'10" ASTM D6164 Granule surfaced, modified bitumen membrane with a bum -off film -and reinforced with non- woven polyester mat. SBS Premium Torch 39.4" x 33'10" ASTM D6164 UltraWhite granule surfaced, modified bitumen UltraWbite membrane with a bum -off film and reinforced with non -woven polyester mat. SBS Premium FR 39.4" x 33'10" ASTM D6164 Granule surfaced, fire rated, modified bitumen Torch membrane with a burn -off film and reinforced with non -woven polyester. mat. SBS Premium FR 39.4" x 33'10" ASTM D6164 UltraWhite granule surfaced, fire rated, modified Torch UltraWhite bitumen membrane with a burn -off film and reinforced with non -woven polyester mat. I.S.O. Twin Pack Dual 750 ml Proprietary A two -component polyurethane insulation Insulation Adhesive cartridges adhesive- I.S.O. FIX 11 30 lb. Proprietary A single component polyurethane insulation adhesive. I.S_O. Stick 5 gal. Proprietary A two -component polyurethane insulation adhesive. Multi -Purpose MB 55 gal. Proprietary An asphalt based adhesive. Cold Adhesive LiquiGard Membrane 6 gal. Proprietary A two -component, solvent -free, asphalt -based --Adhesive urethane adhesive. 1i VIP C ARA It UPI MIAMI•DADECOUNTY NOA No.: 16-0202.10 �FjAmExpiration Date: 03/OS/21 Approval Date: 03/24/16 Page 4 of 135 APPROVED INSULATIONS: Product Name ISO + GL (and Tapered), RESISTA (and Tapered) ISOGARD HD ISOGARD HD Composite DensDeck, DensDeck Prime SECUROCK Gypsum -Fiber Roof Board High Density Wood Fiberboard Perlite Insulation Board APPROVED FASTENERS: Fastener Product Number Name I. Firestone All -Purpose 2. Firestone Heavy -Duty TABLE 2 Product Description Polyisocyanurate Insulation board with glass reinforced organic facer Polyisocyanurate Insulation board with coated fiberglass facer High density Polyisocyanurate roof board with a coated fiberglass -facer Polyisocyanurate foam core laminated to ISOGARD HD board Silicon treated gypsum Gypsum Cover board High Density Wood Fiber insulation board. Perlite Insulation TABLE 3 Product Description Dimensions Insulation and membrane Various fastener Insulation and membrane fastener 3. Concrete Drive Fastener I/4" diameter concrete deck fastener. 4. 5. 6. 7. 8. MB 2" Barbed Metal Metal plates used for Seam Plate membrane securement. 2" Metal Plate Membrane attachment plate. Insulation Fastening Plate Insulation plate for use with Firestone Fasteners #14 Roofgrip Firestone Coiled Metal Batten Strip Insulation and membrane fastener Galvalume AZ55 Batten Bar Various Various 2" dia 2" dia 3" round Various Manufacturer ith Current NOA Firestone Building Products Company, LLC Firestone Building Products Company, LLC Firestone Building Products Company, LLC Firestone Building Products Company, LLC Georgia Pacific Gypsum LLC United States Gypsum Corporation Generic Generic Manufacturer ith Current NOA Firestone Building Products Company, LLC Firestone Building Products Company, LLC Firestone Building Products Company, LLC Firestone Building Products Company, LLC Firestone Building Products Company, LLC Firestone Building Products Company, LLC OMG, Inc. Products MIAMI•DADE COUNTY NOA No.. 16-0202.10 • • • . , Expiration Date: 03/08/21 Approval Date: ,03/24/16 Page 5 of 135 EVIDENCE SUBMITTED: Test Ay yen_ S_ Test Identifier Description Date FM Approvals 1D5A8.AM FM 4470 09/09/98 3003597 FM 4470 07/14/99 3004786 FM 4470 05/16/00 3005030 FM 4470 08/08/00 3014031 FM 4470 07/22/02 3022502 FM 4470 01/29/07 3030227 FM 4470 06/18/07 3007328 FM 4470 07/12/02 3012321 FM 4470 07/29/02 3014692 FM 4470 08/05/03 3033218 FM 4470 08/04/10 3035017 FM 4470 08/04/10 3031943 FM 4470 09/25/09 3033921 FM 4470 08/04/10 3030107 FM 4470 12/24/09 3009613 FM 4470 03/03/11 3028093 FM 4470 03/03/11 3040795 FM 4470 03/24/11 3041534 FM 4470 03/09/11 3042392 FM 4470 06/08/11 3035560 FM 4470 01/11/10 3038191 FM 4470 08/04/11 3040306 FM 4470 09/07/11 3046333 FM 4470 08/10/12 3047398 FM 4470 08/15/13 3037346 FM 4470 03/09/11 3040109 FM 4470 03/09/11 3030227 FM 4470 06/18/07 3044047 FM 4470 08/15/13 Underwriters Laboratories R9516 UL 790 01/25/13 Trinity]ERD 48101.96-1 TAS 114-C & TAS 114-D 01/31/96 F880018-R1 TAS 114 04/21/08 F1037058 ASTM C1289 05/08/08 F10500.108-1 ASTMD6163 08/26/08 F319605.10-1 ASTM D4977 05/19/10 17319605.10-2 ASTM D4977 05/19/10 F319608.10-1 ASTM D4977 08/25/10 F319608.10-2 ASTM D4977 08/25/10 17354005.11 ASTM Physical Properd im V51/11 F410708.12 D 4/12 U41790.05.12-2-R2 DC 10 1/13 U41790.05.12-1-RI F _ 01/21/13 -IRT=ARGON,-Inc. 02-010, 02-011 TAS 114 01/28/02 Atlantic & Caribbean Roof 03-002 TAS 114 03/06/03 Consulting, LLC. NW NOA No.: 16-0202.10 M �®u Expiration Date: 03/08)21 Approval Date: 03/24/16 Page 6 of 135 PRI Construction Materials FBP-018-02-01 Technologies LLC FBP-011-02-01 FBP-008-02-01 FBP-009-02-01 FBP-010-02-01 FBP-014-02-01 FBP-015-02-01 FBP-016-02-01 FBP-017-02-01 FBP-019-02-01 FBP-023-02-01 FBP-007-02-01 FBP-020-02-01 FBP-038-02-03 FBP-038-02-04 FBP-038-02-02 FBP-038-02-01 FBP-043-02-03 FBP-043-02-02 FBP-043-02-04 FBP-043-02-01 FBP-042-02-01 FBP-042-02-02 FBP-058-02-01 FBP-057-02-01 FBP-056-02-01 F13P-087-02-01 FBP-088-02-01 FBP-106-02-01 FBP-109-02-01 FBP-] 13-02-01 FBP-114-02-01 FBP-118-02-01 Rev.I FBP-123-02-01 FBP-118-02-01 FBP-124-02-01 FBP-126-02-01 FBP-127-02-01 FBP-130-02-01 FBP-132=02-01 FBP-133-02-01 Rev.3 FBP-133-02-02 Rev.] FBP-141-02-01 FBP-142-02-01 Rev.l FBP-142-02-02Rev.1 FBP-152-02-01 FBP-059-02-01.4 ASTM 136163 09/07/04 ASTM D6164 09/02/04 ASTM D6222 09/10/04 ASTM D6222 08/31/04 ASTM D6164 09/04/04 ASTM D6164 09/02/04 ASTM D6509 09/02/04 ASTM D6509 09/02/04 ASTM D6163 09/13/04 ASTM D4601 09/14/04 ASTM D6223 09/01/04 ASTM D6222 09/14/04 ASTM D2178 09/14/04 ASTM D6164 01/12/11 ASTM D6164 01/12/11 ASTM D6164 01/12/11 ASTM D6164 12/27/10 ASTM D6164 07/26/11 ASTM D6164 08/02/11 ASTM D6164 07/26/11 ASTM D6164 08/02/11 ASTM D6164 07/26/11 ASTM D6164 07/27/11 ASTM D4601 12/12/08 ASTM D2178 12/12/08 ASTM D2178 12/12/08 ASTM D4798 03/22/13 ASTM D4798 03/22/13 TAS 114(J) 04/19/13 TAS 114(J) 04/19/13 TAS 114(J) 04/17/13 TAS 114(J) TAS 114(J) 01/02/14 TAS 114(J) 07/26/13 TAS 114(J) 01/02/14 TAS 114(J) 08/02/13 ASTM D6163 12/03/13 ASTM D6164 11/20/13 TAS 114(D) 08/23/14 TAS 114LD mPT83/14 I I2/14 12/18/13 TAS 114(J) 01/02/14 TAS 114(J) 10/01/13 TAS 114(D) 12/18/13 ASTMD90301876/135147 06/03/14 TAS 117(B)/114(D) &(H) NOA No.: 16-0202.10 Expiration Date: 03/08/21 Approval Date: 03/24/16 Page 7 of 135 Membrane Type: SBS Deck Type 3I: Concrete Decks, Insulated Deck Description: 2500 psi structural concrete or concrete plank System Type A(17): One or more layers of insulation adhered with approved asphalt. All General and System Limitations apply. One or more layers of any of the following insulations: Base Insulation Laver Insulation Fasteners Fastener able 3 Density/ft' ISO 95+ GL, RESISTA or other Approved polyisocyanurate listed in Table 2 Minimum''%" thick N/A N/A Too Insulation Laver Insulation Fasteners Fastener Table 3 Density/ft= —�� Approved High Density Wood Fiberboard Minimum %" thick N/A N/A Approved Perlite Minimum'/d' thick N/A N/A Note: Concrete deck shall be primed with ASTM D 41 asphalt primer and allowed to dry prior to application of insulation. All insulation shall be adhered to the deck in full mopping of approved asphalt within the EVT range and at a rate of 20-40 lbs./100 ftr. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels used as a top layer shall be placed with the polyisocyanurate side facing down. Base Sheet: One ply of Firestone MB Base or Firestone Ply IV , Ply IV (4) M, Ply VI or Ply VI (6) M ply sheet bonded in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbs./sq. Ply Sheet: 3 �% f j- (Optional) One or more plies of SBS Smooth, MB Base, Firestone Ply IV , Ply IV (4) M, Ply VI or Ply VI (6) M ply sheet, SBS Base or other Approved base or ply sheet adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 Ibs✓sq. Membrane: ) el ` One ply of Firestone SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, 7 SBS Smooth, SBS Premium, SBS Premium FR, SBS Premium FR UltraWhite, SBS Glass, SBS Glass FR or SBS Glass FR UltraWhite adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq. Or w MLAM4DADE COUNTY NOA No.; 16-0202.10 . • • • � , Expiration Date: 03/0821 Approval Date: 03/24/16 Page 37 of 135 (Not with MB Base) One ply of Firestone SBS Smooth, SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS Glass, SBS Glass FR, SBS Glass FR UltraWhite, SOBS Premium, SBS Premium FR, SBS Premium FR UltraWhite fully adhered with LiquiGard Membrane Adhesive squeegee applied at a rate of 1.5 — 2 gal./square. The minimum 3 in. wide side laps are sealed with LiquiGard Membrane Adhesive squeegee applied at a rate of 1.5 — 2 gal./sq. Or One ply of Firestone SBS Torch, SBS Torch UltraWhite, SBS FR Torch, SBS FR Torch UltraWhite, SBS Glass FR Torch, SBS Glass FR Torch UltraWhite, SBS Premium Torch, SBS Premium Torch UltraWhite, SBS Premium FR Torch or SBS Premium FR Torch UltraWhite, torch adhered. Or (Not with SBS Base, SBS Smooth) One ply of Firestone SBS Smooth, SBS Cap, SBS Cap UltraWhite, SBS FR Cap, SBS FR Cap UltraWhite, SBS Glass, SBS Glass FR, SBS Glass FR UltraWhite, SBS Premium, SBS Premium FR or SBS Premium FR UltraWhite cap sheet fully adhered to the base sheet with Firestone Multi -Purpose MB Cold Adhesive applied at 1 %a - 2 gal./sq. Surfacing: (Optional) Any coating, listed below, used as a surfacing, must be listed within a current NOA. Install one of the following to obtain required fire classification. 1. Gravel or slag at 400 lbs./sq. or 300 lbs./sq, respectively, in a flood coat of approved asphalt at 60 lbs./sq. 2. Karnak 97 Fibrated Aluminum Asphalt Roof Coating or Asbestos Free Aluminum Roof Coating at 1'/2 gal./sq. Maximum Design Pressure: -255 psf. (Perlite as top insulation layer) (See General Limitation 419) -520 psf. (High Density Wood Fiberboard as top insulation layer) (See General Limitation #9) NOA No.. 16-0202.10 Expiration Date: 03108t21 Approval Date: 03/24/16 Page 38 of 135 CONCRETE DECK SYSTEM LIMITATIONS: If mechanical attachment to the structural deck through the lightweight insulating concrete is proposed, a field withdrawal resistance testing shall be performed to determine equivalent or enhanced fastener patterns and density. All testing and fastening design shall be in compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117, calculations shall be signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance, refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. . Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 2040 lbsJsq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each sidelap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbsJsq. Note: Spot attached systems shall be limited to a maximum design pressure of 45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 2751b£, as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 2751bf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida Registered Engineer, Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform with Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and comers). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended comers and comers). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and — --Rule 61G20-3-of the Florida Administrative Code. END OF TMS ACCEPTANCE FILE ff'-k'PY NOA No.: 16-0202.10 MIAMI-DADE COUNTY ... � � Expiration Date: 03/08/21 Approval Date: 03/24/16 Page 135 of 135