Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning & Development Services Building S Code Regulation Division 2300 Virginia Avenue Fort Pierce,FL 34982 Phone:(772)462.2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 7091 US 1 City / State / Zip: Port St Lucie, FI 34952 Parcel#: 3422-211-0011-000/3 Zoning: CG APPLICATION INFORMATION Permit Number: 1705-0252 Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Robert F Jr Machen Business Name: Amant Homes Of Florida Inc Business Addr: 1672 Se Pleasantview St City / State / Zip: Port St Lucie, FI 34983 REVIEW COMMENTS S(;BYD E `S't. Lucie COlffiye 1 Owner(s): Jann D Rudd / Matthew H Rudd Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: 772-336-5764 Email: Mr-Planman@Yahoo.Com REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING 5/22/2017 Comment: i, RECORDED NOTICE OF COMMENCEMENT. 5/22/2017 Comment: SUB AGREEMENT FOR ELECTRICAL AND MECHANICAL. 5/22/2017 Comment: i GENERAL CONTRACTOR ON HOLD, WILL NEED TO UPDATE LICENSE WITH CONTRACTOR LIC. DER FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 5/1112017 511112017 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 6/812017 61812017 618/2017 Comment: PLANS EXAMINER MECHANICAL INCOMPLETE Carl Peterson Comment: PLEASE SHOW THE ASSEMBLY OCCUPANCY MEETING THE REQUIREMENTS FOR VENTILATION IN THE 6/8/2017 FLORIDA MECHANCIAL CODE CHAPTER 4 AS REQUIRED IN SECTION 1009 OF THE FLORIDA EXISTING BUILDING CODE. PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 61612017 6/6/2017 Comment: NEED CORRECT OCCUPANT COUNT TO RESUME THIS REVIEW.SECTION 403 FPC 2014 ' 6/7l2017 Comment: ENGINEER TO DESIGN THE PREP ROOM PER F.A.C. 69K-24.042 [ NOTE 2 ] ON PLANS' SHOW ALL NON- POROUS SURFACES, HAND WASH SINK, FLOOR DRAINS ETC FOR REVIEW w Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Faz:(772)462-6443 REVIEW COMMENTS PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 6/5/2017 Comment: OCCUPANT LOAD ON PLANS HAS BEEN CALCULATED INCORRECTLY • DESIGN PROFESSIONAL TO FOLLOW FBC TABLE 1004.1.2 FOR ALL ROOM AREAS OF THIS FACILITY • UN -FIXED CHAIRS IN THE 6/5/2017 CHAPEL, LOBBY, CAFE', CONFERENCE ROOM, PREP ROOM, ETC. CALCULATE THE NET AND GROSS FLOOR AREAS ON PLANS PER SAME TABLE • PER PROJECT DATA COMPLETE FACILITY IS A-3 CALCULATE ALL ROOM AREAS ON PLANS FOR LOADS OF 7.5 OR 15 NET • IF USING FIXED SEATING SHOW THE FIXATION DETAILS ON PLANS FBC 1004.4 6/5/2017 Comment: NEED ALL DETAILS FOR THE CAFE ON PLANS 6/5/2017 Comment: DESIGN AN INTERIOR WALL AND CEILING FINISHES TABLE ON PLANS PER FBC TABLE 803.9 • SHOW THE FLOOR FINISH REQUIREMENTS ON PLANS PER FBC SECTION 804 6/5/2017 Comment: ENGINEER TO MODIFY THE NOTE ON PAGE 1 OF PLANS • WE DO NOT ENFORCE THE 2010 FBC EXISTING BUILDING 6/5/2017 Comment: ENGINEER TO INCLUDE A BUCK DETAIL ON PLANS FOR THE FRONT DOORS AND SIDE WINDOW' FBC 1710.10 6/5/2017 Comment: IS THE BUILDING PROTECTED OR UN -PROTECTED [ TYPE A OR B ] NOTE ON PLANS PER FBC TABLE 601 6/5/2017 Comment: SHOW THE DETAILS AND LOCATION FOR THE MALTESE CROSS ON PLANS' F.A.C. 69A-60.0081 615/2017 Comment: SHOW THE TOILET AND BATHROOM FINISH MATERIAL REQUIREMENTS ON PLANS PER FBC SECTION 1210.2.1 AND 1210.2.2 6/5/2017 Comment: ENGINEER TO SHOW ALL GYPSUM BOARD AND ACCESSORY TESTING STANDARDS ON PLANS PER FBC TABLE 2506.2 6/5/2017 Comment: SHOW AN INTERIOR WALL DETAIL ON PLANS W/ ATTACHMENTS Comment: CONTRACTOR TO SUBMIT [ 3 ] SEALED ENERGY CALCS [ HAVE 1 ]' THIS IS NOT CANNON OFFICE 6/5/2017 PROJECT SUMMARY - DESCRIPTION IS NOT OFFICE, STATE THE CORRECT ADDRESS ON FORMS, ENGINEER TO FILL OUT THE MANDATORY REQUIREMENTS AND NOTE ALL REQUIRED ENERGY CRITERIA ON PLANS 6/6/2017 Comment: SHOW THE REFERIGERATION SPECIFICATIONS ON PLANS PER F.A.C. 69K-24.042 6/6/2017 Comment: CALCULATE THE EXHAUST VENTILATION ON PLANS PER F.A.C. 69K-24.042 CRITERIA FOR THE PREP ROOM 6/6/2017 Comment: DESIGN PROFESSIONAL TO STATE ALL RULES FROM FLORIDA STATUTES, FLORIDA BUILDING CODES AND FLORIDA ADMINISTRATIVE CODE FOR THIS FACILITY 6/6/2017 Comment: SHOW A FRONT WALL ELEVATION WITH THE REQUIRED DISPLAY THE NAME OF THE ESTABLISHMENT AND THE NAME OF THE FUNERAL DIRECTOR F.S. 497.380 NOTE:14 6/6/2017 Comment: ENGINEER TO DESIGN AN OCCUPANCY SEPARATION TABLE ON PLANS PER FBC 508.4 OR SHOW INCIDENTAL USES PER 509 Comment: PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED 6/6/2017 ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET OF PLANS CAN BE SUBMITTED PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. LUCIE COUNTY RESOLUTION #13-196 Comment: DEAR ST. LUCIE COUNTY PERMIT APPLICANT, THANK YOU FOR CHOOSING TO DO BUSINESS AND INVEST IN ST LUCIE COUNTY. ST LUCIE COUNTY IS COMMITTED TOASSISTING YOU NAVIGATE THE BUILDING REVIEW PROCESS. PLEASE KNOW THAT COUNTY STAFF IS COMMITTED TO CUSTOMER SERVICEAND PART OFTHAT SERVICE IS PROVIDING ASSISTANCE AND GUIDANCE WITH OUR PROCESSES. PLEASE DO NOT HESITATE TO CONTACT US TO FURTHER DISCUSS YOUR BUILDING PROJECT AS NEEDED. 6/6/2017 PLEASE SEE THE ATTACHED PLAN REVIEW COMMENTS WHICH HAVE BEEN GENERATED FOR YOUR PERMIT. AS SOON AS WE RECEIVE THE MODIFIED PLANS AND ANY ADDITIONAL REQUIRED DOCUMENTATION BACK FROM THE DESIGN PROFESSIONAL, CONTRACTOR OR OWNER WE WILL PERFORM TO PERMITTING FOR PERMIT ISSUANCE. THANKYOU Planning S Development Services Building S Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462-6443 Address: City / State / Zip: Parcel #: 7091 US 1 ,.Port St Lucie, FI 34962 3422-211-0011-000/3 REVIEW COMMENTS SCANNED BY St. bit ho r'rnintl 1 Owner(s): Jann D Rudd / Matthew H Rudd Jurisdiction: SAINT LUCIE COUNTY Zoning: CG Lot#: APPLICATION INFORMATION Permit Number: 1705-0252 Stories: Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Robert F Jr Machen Business Name: Amant Homes Of Florida Inc Business Addr: 1672 Se Pleasantview St City / State / Zip: Port St Lucie, FI 34983 REVIEWS AND COMMENTS Review Type DOCUMENTS MISSING Block: Automatic Sprinkler System? No Fax Number: 772-336-5764 Email: Mr-Planman@Yahoo.Com Status Reviewed By Date Started Date Completed Date Released PENDING 5/22/2017 Comment: RECORDED NOTICE OF COMMENCEMENT. 5/22/2017 Comment: SUB AGREEMENT FOR ELECTRICAL AND MECHANICAL. 512212017 Comment: I GENERAL CONTRACTOR ON HOLD, WILL NEED TO UPDATE LICENSE WITH CONTRACTOR LIC. DER FIRE DEPARTMENT REVIEW PENDING Tony Jerger i Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 5111/2017 5111/2017 Comment: PE REVIEW COMMENTS (2) INCOMPLETE Joe Ciclo 6/21/2017 Comment: OCCUPANT LOAD ON PLANS HAS BEEN CALCULATED INCORRECTLY' DESIGN PROFESSIONAL TO FOLLOW FBC TABLE 1004.1.2 FOR ALL ROOM AREAS OF THIS FACILITY' LOBBY, CAFE', CONFERENCE ROOM, PREP ROOM, ETC. CALCULATE THE NET AND GROSS FLOOR AREAS ON PLANS PER SAME TABLE' PER PROJECT DATA COMPLETE FACILITY IS A-3 • CALCULATE ALL ROOM AREAS ON PLANS FOR LOADS 6/5/2017 - OF 7,5 OR 15 NET "" SECOND REVIEW.... ENGINEER TO CALCULATE THE OCCUPANT LOADS CORRECTLY PER FBC TABLE 1004.1.2' LOBBY IS STANDING SPACE @ 5 NET AND CAFE WOULD BE 7 NET SHOW ALL UN -FIXED TABES AND CHAIRS ON PLANS FOR CAFE IF APPLICABLE TO BE 7 NET' CONFERENCE ROOM IS ASSEMBLY' OFFICE IS A GROUP B' OCCUPANT LOADS ON PLANS ARE INCOMPLETE 6/5/2017 Comment: NEED ALL DETAILS FOR THE CAFE ON PLANS ••'• INCOMPLETE.... Comment: DESIGN AN INTERIOR WALL AND CEILING FINISHES TABLE ON PLANS PER FBC TABLE 803.9 • SHOW THE 6/5/2017 FLOOR FINISH REQUIREMENTS ON PLANS PER FBC SECTION 804 "" SECOND REVIEW — ROOM FINISH TABLE ON SHEET 1 IS NOT TO CODE •••• Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172-Fax:(772)462.6443 REVIEW COMMENTS Page 2 6/512017 l.ommem:W 011U"InM IUILCI HIVU JHIIIRVVIV1 r11VIJf11VW ICRIML RCl.lU1RC1VICIVIJ U11 rLM1VJ rCR rOV JCVIIVIV 1210.2.1 AND 1210.2.2 ****SECOND REVIEW**** DETAILS NOT ON PLANS**** 6/6/2017 Comment: 0 SHOW THE REFERIGERATION SPECIFICATIONS ON PLANS PER F.A.C. 69K-24.042 •••• SECOND REVIEW ••" DETAILS ANS MANUFACTURERS SPECS NOT ON PLANS •••. 6/21/2017 Comment: 1p CORRIDORS AND ALL OPENINGS MUST BE RATED PER FBC TABLE 1018.1 / SHOW ALL DETAILS ON PLANS INCOMPLETE FROM FIRST REVIEW** 6/21/2017 Comment: SHOW REQUIRED PANIC HARDWARE ON PLANS PER FBC 1008.1.10 6/21/2017 Comment: ALL PLAN PAGES AND DETAILS MUST MATCH / FLOOR DRAIN STILL NOT SHOWN 6/21/2017 Comment: CONTRACTOR TO PAY ALL RE -REVIEW FEES UPON RE -SUBMITTAL OF PLANS Comment: PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS PLEASE NOTE: (1)ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED 6/21/2017 ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET OF PLANS CAN BE SUBMITTED PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. 4jL LUCIE COUNTY RESOLUTION #13-196 ". 6/21/2017 Comment: COMMENTS E-MAILED AS OF THIS DATE PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 618/2017 618/2017 61812017 Comment: PLANS EXAMINER MECHANICAL INCOMPLETE Carl Peterson Comment: PLEASE SHOW THEASSEMBLY OCCUPANCY MEETING THE REQUIREMENTS FOR VENTILATION IN THE 6/8/2017 FLORIDA MECHANCIAL CODE CHAPTER 4 AS REQUIRED IN SECTION 1009 OF THE FLORIDA EXISTING BUILDING CODE. 6/21/2017 Comment: SECOND REVIEW •" DID NOT ADDRESS COMMENT... PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 616/2017 6/6/2017 Comment: NEED CORRECT OCCUPANT COUNT TO RESUME THIS REVIEW.SECTION 403 FPC 2014 6/7/2017 Comment: ENGINEER TO DESIGN THE PREP ROOM PER F.A.C. 69K-24.042 [ NOTE 21 ON PLANS' SHOW ALL NOW POROUS SURFACES, HAND WASH SINK, FLOOR DRAINS ETC FOR REVIEW i PLANS EXAMINER REVIEW COMPLETE Joe Cicio 61512017 6/2112017 6121/2017 ! Comment: ZONING REVIEW COMPLETE Lydia Galbraith 512212017 5/22/2017 512212017 Comment: Joe Cicio From: Joe Cicio Sent: Wednesday, June 21, 2017 9:42 AM To: 'amanthomes@hotmail.com' Cc: jannrudd@comcast.net'; Joe Cicio Subject: Second Review Comments for Permit Number 1705-0252 Attachments: Report_FL_Review_Comments_Noncompliantjrf.pdf Dear St. Lucie County Permit Applicant, Thank you for choosing to do business and invest in St Lucie County. St Lucie County is committed to assisting you navigate the Building review process. Please know that County staff is committed to customer service and part of that service is providing assistance and guidance with our processes. Please do not hesitate to contact us to further discuss your building project as needed. Please see the attached plan review comments which have been generated for your permit. As soon as we receive the modified plans and any additional required documentation back from the design professional, contractor or owner we will perform to permitting for permit issuance. Thank You %deAd Wt. L:& Plans Examiner Standard Building Inspector Building Plans Examiner One and Two Family Dwelling Inspector One and Two Family Plans Examiner StLu.ci,&Cvu+4y PLaMKivtg a-,&DevttorAvzvL4-S2rvi"k How- way your serves today ** W-Kt Carl, Pefersew, fiu i 1d.i atg of facial, ah pie a�vt f@ytLuT izco orq fa- pow,� yvur suggevli vrly, c.vwvK-vew &+%4 fQed Via c lc Please Note: Florida has very broad public records laws. Most written communications to or from County officials regarding County business are public records _available to the public and media upon request. It is the policy of St. Lucie County that all County records shall beopen for personal inspection, examination and / or copying. Youre-mail communications will be subject to public disclosure unless an exemption applies to the communication. If you received this email in error, please notify the sender by reply e-mail and delete all materials from all computers. Planning 8 Development Services Building & Cade Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 7091 US 1 City / State / Zip: Port St Lucie, FI 34952 Parcel M 3422-211-0011-000/3 Zoning: CG APPLICATION INFORMATION Permit Number. 1705-0252 Permit Type: COMMERCIAL RENOVATION Contractor Name: Business Name: Business Addr. City / State / Zip: Robert F Jr Machen Amant Homes Of Florida Inc 1672 Se Pleasantview St Port St Lucie, FI 34983 REVIEWS AND COMME REVIEW COMMENTS SCANNED BY St. UJOP rh infi 1 RECEIVED JUL 172017 Owner(s): Jann D Rudd / Matthew H Rudd Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number 772-336-5764 Email: —M a'Vh c(:n'f {ror+os ci])'t'I Review Type Status Reviewed By Data Started Data Completed Date Released DOCUMENTS MISSING PENDING 5/22/2017 Comment RECORDED NOTICE OF COMMENCEMENT. 5/22/2017 Comment: SUE; AGREEMENT FOR ELECTRICAL AND MECHANICAL. 5122/2017 Comment GENERAL CONTRACTOR ON HOLD, WILL NEED TO UPDATE LICENSE WITH CONTRACTOR LIC. DER FIRE DEPARTMENT REVIEW PENDING Tony Jorger Comment: FRONT COUNTER REVIEW COMPLETE Lashahna Ingram SM1/2017 5111/2017 Comment: PE REVIEW COMMENTS (2) COMPLETE Joe Clcio 6/21/2017 7/3/2017 V3/2017 Comment: PE REVIEW COMMENTS (3) COMPLETE Joe Cicio 7/3/2017 7/14/2017 7/14/2017 -� - Comment. PE REVIEW COMMENTS (4) INCOMPLETE Joe Clcio 7/14/2017 Comment 7/32017 REAR CORRIDOR WIDTH NEEDS TO BE ADDRESSED / GURNEY TRAFFIC AND INCAPABLE OF SELF PRESERVATION "SEE FBC TABLE 1018.2 • • D 7/14/2017 Comment: FOURTH REVIEW FEE DUE < Comment: ENGINEER HAS NOW RE-CONFIGGURED THE REAR RESTROOM DOORS WHICH ARE NOT COMPLIANT 7/14/2017 WITH FBC 1005.7.1 •" DOORS IN ANY POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE THAT ONE HALF" Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)&62.2172 Fax:(772)462.6447 REVIEW COMMENTS Page 2 Comment: "`" 7/14/2017 REAR CORRIDOR OUTSIDE PREP„,ROOM-IS NOT TO.SCALE tOf�IGETH[SCOF2RIDORSCALWCORREC. Y% TEIEDOORTOTHF REP-ROCiaWlitiBI=COMRLMUE;.iOM'10t1,r:T- 7/14Y2017 Comment: PLEASE-RE-SU13MIT [ 3 ] SETS OF REVISED PLANS W/ 12 ] PDF DISCS Comment: PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED 7/14/2017 ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET OF PLANS CAN BE SUBMITTED PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. LUCIE COUNTY RESOLUTION #13-196 COMMENTS SENT 711412017 Comment COMMENTS E-MAILED AS OF THIS DATE 7/14/2017 Comment: HAVE FORWARDED THE PLANS TO THE PLUMBING REVIEWER PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 618/2017 6/812017 6/8/2017 Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 7/7/2017 7/7/2017 Comment: PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 6/612017 Comment: ASSEMBLY OCCUPANCY MUS <AVSNARATE SIX RESTROOMS 403.2 FPC 2014 7/5/2017 RELABLE UNISEX AS MENS RES MAf4=ONE WATERCL NE LAV ADA COMPLIANT IN WOMENS. PLANS EXAMINER REVIEW COMPLETE Joe Cl io 6/5/2017 6/21/2017 6/21/2017 Comment: ZONING REVIEW COMPLETE Lydla Galbraith 5/2212017 512212017 6/22I2017 Comment PAUL WELCH INC. MECH-ELECT-Cw ENG 1954 BILTMORE ST. S114 PORT ST. LUCIE, FL 34984 PAUL WELCH, P.E. FLA REG NO 29945 t & A 2011 S�•—.� Goy Planning & Development Services Building &Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462.6443 Address: 7091 US 1 City / State / Zip: Port St Lucie, FI 34952 Parcel#: 3422-211-0011-00013 Zoning: CG APPLICATION INFORMATION Permit Number: 1705-0252 REVIEW COMMENTS bLANNED BY St. Luria rnnntl, Page 1 Owner(s): Jann D Rudd / Matthew H Rudd Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION k E Contractor Name: Robert - F Jr Machen Fax Number: 772-336-5764 t Business Name: Amant Homes Of Florida Inc Business Addr: 1672 Se Pleasantview St Email: Mr-Planman@Yahoo.Com City I State / Zip: Port St Lucie, A 34983, REVIEWS AND COMMENTS Review Tyne Status Reviewed By .Date Started Date Completed Date Released DOCUMENTS MISSING PENDING 5/22/2017 Comment: RECORDED NOTICE OF COMMENCEMENT. 5/2212017 Comment: SUB AGREEMENT FOR ELECTRICAL AND MECHANICAL. 5/22/2017 Comment: GENERAL CONTRACTOR ON HOLD, WILL NEED TO UPDATE LICENSE WITH CONTRACTOR LIC. DER • FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: t FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 511112017 5/11/2017 Comment: PE REVIEW COMMENTS (2) COMPLETE Joe Ciclo 6/2112017 713/2017 71312017 Comment: PE REVIEW COMMENTS (3) COMPLETE Joe Cicio 713/2017 7/14/2017 7/1412017 Comment: PE REVIEW COMMENTS (4) INCOMPLETE Joe Cicio 7/1412017 7/3/2017 Comment: REAR CORRIDOR WIDTH NEEDS TO BE ADDRESSED / GURNEY TRAFFIC AND INCAPABLE OF SELF PRESERVATION "SEE FBC TABLE 1018.2 7/14/2017 Comment: FOURTH REVIEW' FEE DUE Comment: ENGINEER HAS NOW RE-CONFIGGURED THE REAR RESTROOM DOORS WHICH ARE NOT COMPLIANT 7/14/2017 WITH FBC 1005.7.1' —DOORS IN ANY POSITION SHALL NOT REDUCE THE REQUIRED WIDTH BY MORE THAT ONE HALF" a Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462.2172 Fax:(772)462-6443 REVIEW COMMENTS Page 2 7/14/2017 Comment: REAR CORRIDOR OUTSIDE PREP ROOM IS NOT TO SCALE' ONCE THIS CORRIDOR SCALES CORRECTLY THE DOOR TO THE PREP ROOM WILL BE COMPLIANT WITH 1005.7.1 7/14/2017 Comment: PLEASE RE -SUBMIT [ 3 ) SETS OF REVISED PLANS W/ [ 21 PDF DISCS Comment: PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED 7/1412017 ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET OF PLANS CAN BE SUBMITTED PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. LUCIE COUNTY RESOLUTION #13-196 COMMENTS SENT 7/1412017 Comment: COMMENTS E-MAILED AS OF THIS DATE 7/14/2017 Comment: HAVE FORWARDED THE PLANS TO THE PLUMBING REVIEWER PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 61812017 6/8/2017 61812017 Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 717/2017 7/7/2017 Comment: r PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 616/2017 Comment: ASSEMBLY OCCUPANCY MUST HAV E SEPARATE SEX RESTROOMS PER 403.2 FPC 2014 7/5/2017 RELABLE UNISEX AS MENS RESTROOM AND MAKE ONE WATERCLSET AND ONE LAV ADA COMPLIANT IN WOMENS. PLANS EXAMINER REVIEW COMPLETE Joe Cicio 6/512017 6/2112017 612112017 Comment: ZONING REVIEW COMPLETE Lydia Galbraith 512212017 5/2212017 5/2212017 Comment: a