HomeMy WebLinkAboutNOAFILE C
MIAM10 MIAMI-DADE COUNTY
mom PRODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy
Owens Corning SCANNED
Owens CorningParkway
Toledo, OH 43659 BY
St. Lucie County
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: WeatherLock G & WeatherLock MAT
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed
by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at thejob site at the request of the Building Official.
This renews NOA#08-0108.04 and consists of pages 1 through 3.
The submitted documentation was reviewed by Alex Tigera.
P NOA No.: 12-1114.01
MIAMI DAD' COUNTY Expiration Date: 04/03/18
Approval Date: 04/04/13
Page I of 3
71
ROOFING COMPONENT APPROVAL
Category:
Roofing
Sub -Category:
Underlayment
Material:
SBS
PRODUCTS DESCRIPTION:
Product Dimensions
WeatherLock G 36" x 33.3' rolls
36" x 66.6' rolls
Test Product
Specification Description
ASTM D 1970 SBS self -adhering modified asphalt underlayment
sheet material with a surfacing of opaque
granules; for use as an underlayment in sloped
roof assemblies.
WeatherLock MAT 36" x 33.3' rolls ASTM D 1970 SBS self -adhering modified asphalt underlayment
36';x 66.6' rolls sheet material with a polymeric asphalt film
surfacing; for use as an underlayment in sloped
roof assemblies.
MANUFACTURING LOCATION:
1. Brentwood, NH
EVIDENCE SUBMITTED:
Test Agency Test Identifier Test Name/Report Date
PRI Asphalt Technologies, Inc. NEI-006-02-01 ASTM D 1970 04/14/05
PRI Construction Materials NEI-008-02-01 ASTM D 1970 12/01/06
Technologies, LLC
APPROVED ASSEMBLIES:
eek Type I: Wood, non -insulated, new construction
Deck Description: 19/;2' or greater plywood or wood plank
System E(1): Anchor sheet mechanically fastened deck, membrane adhered.
Base Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" side lap and a
6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the laps and
two staggered rows 12" o.c. the field of the roll.
Membrane: One or more plies of WeatherLock G or WeatherLock MAT with a minimum 3" side lap and 6"
end lap. Place the first course of membrane parallel to the eave, rolling the membrane to obtain
maximum contact. Remove the release membrane as the membrane is applied. Vertical
strapping of the roof with WeatherLock G or WeatherLock MAT is acceptable.
Surfacing: Approved for Asphaltic shingles, wood shakes and shingles, quarry slate roof assemblies.
NOA No.: 12-1114.01
Expiration Date: 04/03/18
Approval Date: 04/04/13
Page 2 of 3
MIA
LIMITATIONS:
l . Fire classification is not part of this acceptance.
2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with
applicable building code. WeatherLock G and WeatherLock MAT underlayment shall be installed in strict
compliance with applicable Building Code.
3. WeatherLock G and WeatherLock MAT underlayment shall be applied to a smooth, clean and dry surface with
deck free of irregularities.
4. WeatherLock G and WeatherLock MAT underlayment shall not be applied over an existing roof membrane as a
recover, but may be applied over a roofing Base/Anchor sheet underlayment.
5. WeatherLock G and WeatherLock MAT underlayment shall not be left exposed as a temporary roof for longer than
30 days of application.
6. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with
specific prepared roofing products.
7. WeatherLock G or WeatherLock MAT underlayment may be used with any approved roof covering Notice of
Acceptance listing WeatherLock G or WeatherLock MAT underlayment as a component part of an assembly in the
Notice of Acceptance. If WeatherLock G or WeatherLock MAT underlayment is not listed, a request may be made
to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance,
and fire testing results.
8. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep
the deck thoroughly to remove any dust and debris prior to application.
9. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane
from the center outward in both directions. For ridge applications, center the membrane and roll from the center
outward in both directions.
10. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to
overlap areas.
11. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control
Notice of Acceptance and applicable Building Code.
12. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around, the protrusion to ensure a tight fit. A second layer of WeatherLock G or
WeatherLock MAT underlayment shall be applied over the underlayment.
13. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 9N-3 of the Florida Administrative Code.
14. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo and
the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product
Control Seal as shown below.
MIAMI-DADE COUNTY
END OF THIS ACCEPTANCE
NOA No.: 12-1114.01
Expiration Date: 04/03/18
Approval Date: 04/04/13
Page 3 of 3
MIMI m
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE
Ike Industries Ltd.
40 Hansen Rd. S.
Brampton, Ontario CANADA
L6W3H4
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.miamido de,gov/building/
Akinei ris yi
jga 1�1: INEZIly
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code,
DESCRIPTION: Cambridge AR
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 10-0913.02
Expiration Date: 05/05/16
Approval Date: 05/05/11
Page I of 4
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Asphalt Shingles
Materials
Laminate
Deck Type:
Wood
SCOPE
This approves a roofing system using Cambridge AR asphalt shingles manufactured by IKO Industries Ltd. as
described in Section 2 of his Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test
Product Description
Specifications
Cambridge AR 13
a/4" x 40 ?/e' TAS 110
A heavy weight, fiberglass reinforced
laminate asphalt shingle.
MANUFACTURING LOCATION
1. Kankakee, IL
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Report
Date
PRI Construction Materials Inc.
IKO-050-02-01
TAS 100
12/21/09
FM Approvals
3041689
ASTM D 3462
02/23/11
FM Approvals
3036971
ASTM D 3161 (TAS-I07)
01/04/09
FM Approvals
3042673
ASTM E 108
04/12/11
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 9B-72 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. Exposure and course layout shall be in compliance with Detail'A', attached,
5. Nailing shall be in compliance with Detail 'B', attached.
MIAMI-DADE COUNTY
M-6 1
It
NOA No.: 10-0913.02
Expiration Date: 05/05/16
Approval Date: 05/05/11
Page 2 of 4
11
LABELING
1. Shingles shall be labeled with the Miami -Dade Seal as seen below, or the wording "Miami -Dade County
Product Control Approved".
MIAMI•DADE COUNTY
...4 1
BUILDING PERMIT REQUIREMENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 10-0913.02
Expiration Date: 05/05/16
Approval Date: 05/05/11
Page 3 of 4
FIRSTCOURSE
13 �"
6
MIAMI-DADE COUNTY
,..,r r
a
DETAIL A
CAMBRIDGE AR COURSE LAYOUT
ROOF
Note: RooW Cement not shown In this layout.
This drawing is for course layout only. See Detail
for nailing and cement placement detala.
THIRD COURSE
SECOND COURSE
DETAIL B
CAMBRIDGE AR
40 e"
Roofing Cement
END OF THIS ACCEPTANCE
EXPOSURE
NOA No.: 10.0913.02
Expiration Date: 05/05/16
Approval Date: 05/05/11
Page 4 of 4