HomeMy WebLinkAboutPROJECT INFORMATION 2RECEI'.7 1 J Z017
'SALSBURY
INDUBYRIES
W W W.MAILBOXES.COM
SECTION 10550
(New SECTION 105513.13)
MAILBOXES
Display hidden notes to specter. (Don't know how? Click ere) JLN ViVE®
PART 1 GENERAL ,t rfrBr+/11/nPl/
1.1 SECTION INCLUDES
A. Cluster Box Units— Regency Decorative.
B. Outdoor Parcel Lockers.
1.2 RELATED SECTIONS
A. Section 04800- Masonry Assemblies.
B. Section 05500 - Metal Fabrications: Metal anchors.
C. Section 03300 - Cast -in -Place Concrete.
1.3 REFERENCES
A. United Stales Postal Service (USPS):
1. USPS-B-1118: United States Postal Service Standard, Cluster Box Units.
2. USPS PUBLICATION 16.
B. Architectural and Transportation Barriers Compliance Board (ATBCB): Americans with
Disabilities Act Accessibility Guidelines (ADAAG) for Buildings and Facilities.
C. IBC - International Building Code.
C � fi 'J r' :j :L ^• �
D. ASTM A 666 - Specification for Austenitic Stainless Steel Sheet,:Strip;�Plate and' Flat
Bar. 1 u cr
E. ASTM B 209 - Specification Aluminum and Aluminum Alloy Sheet and Plate:
F. ASTM B 221 - Specification Aluminum and Aluminum Alloy Extruded Bar; Rods, Wire,: •a
Shapes, and Tubes.
1.4 SUBMITTALS
A. Submit under provisions of Section 01300. - _
B. [ Product Data ]: Manufacturer's data sheets on each product to be dsed,�Including: _:.
1. Construction details, material descriptions, dimensions andf'ibishes:
2. Preparation instructions and recommendations.
3. Storage andhandlingrequirements and recommendations.-
4. Installation methods. -
10550-1 - -
D,
k?
AO -PROVED REVISE AND RESUMW
APPROVEDASNOTED 13NOTAPPROVED-RESU66118 MREQ(Mp
Approval is only for General Conformance with the design
concept of the project and does not relieve the Contractor of
responsibility for any deviation from the requirements of the
contract documents or spec69catlons unless tfea Contractor has
specifically informed the Engineer In writing of such deviation
at the time of submission and has obtained written approval of
the specific deviation. Approval shall not relieve the Contractor
of responsibility for errors or omissions In the shop drawings.
Contractor is responsible for dimensions to be confirmed
and correlated at the job site for information that pertains to
electrical and PIumIgPg connections and for Coordination of
veork to all udingolty suppilere.
ey: Dab. -1 &-- 201 i
Structural Engineering, hm
C. Shop Drawings: Prepared specifically for this project; show dimensions of mailboxes
and interface with other products.
D. Selection Samples: For each finish product specified, two complete sets of color chips
representing manufacturer's full range of available colors and patterns.
E. Verification Samples: For each finish product specked, two samples, minimum size 2
Inches (50 mm) square, representing actual color and texture.
1.5 REGULATORY REQUIREMENTS
A. Comply with USPS-13-1118 Specification.
B. Comply with Americans with Disabilities Act Accessibility Guidelines (ADAAG).
1.6 QUALITY ASSURANCE
A. Manufacturer Qualifications: Manufacturer shall have a Quality System in place to
ensure and be able to substantiate that manufactured units conform to requirements and
match the approved design and must be ISO 9001:2008 certified.
1.7 DELIVERY, STORAGE AND HANDLING
A. Inspect the materials upon delivery to ensure that specified products have been
received.
B. Store materials protected from exposure to harmful weather conditions.
C. Handle materials to prevent damage or marring of finish.
1.8 WARRANTY
A. Manufacturers standard warranty to repair or replace components of postal specialties
that fail in materials or workmanship within one year from date of Substantial
Completion.
PART 2 PRODUCTS
2.1 MANUFACTURERS
A. Acceptable Manufacturer: Salsbury Industries, 1010 East 62"d Street; Los Angeles, CA
90001-1598; Toll Free Tel: 800-MAILBOX (800-624-5269); Fax: 800-624-5299; Email:
salsbury@mailboxes.com; Web: www.mailboxes.com
B. Substitutions: Not permitted.
C. Requests for substitutions will be considered in accordance with provisions of Section
01600.
2.2 CLUSTER BOX UNITS - Regency Decorative
A. Front -Loading Outdoor Mailboxes: USPS approved Cluster Box Unit (CBU); aluminum
with one outgoing mail slat. 360 degree wrapped hinges on all doors. Tenant doors
equipped with five -pin cylinder lock cam with dust and rain shield. F-Spec as
manufactured by Salsbury Industries. Decorative trim on top and pedestal.
1. Model: 330OR Regency Series.
a. Made] 3308R, Type I: 8 compartments, 1 outgoing mail receptacle, 2 parce
lockers.
10550-2
b. Model 3312R, Type II: 12 compartments, 1 outgoing mail receptacle, 1 parcel
locker.
c. Model3316R, Type III: 16 compartments, 1 outgoing mail receptacle, 2
parcel lockers.
d. Model 3313R, Type IV: 13 compartments, 1 outgoing mail receptacle, 1
parcel locker.
2. Cabinet: 0.10 inch (2.5 mm) thick welded aluminum sheet.
3. Doors: Minimum 0.125 inch (3 mm) thick aluminum, with stainless steel hardware
and hinges.
4. Locks: 5-pin cylinder cam lock with spring -loaded cover on each unit, 3 keys each
lock; USPS-1172 910B lock.
5. Finish: Powder coated.
a. Color. Sandstone - standard.
b. Color. Bronze - standard.
c. Color. Green -standard.
d. Color. Black - standard.
e. Color. White - standard.
6. Box Identifications: Self-adhesive with black text on silver background; weather
resistant.
2.3 OUTDOOR PARCEL LOCKERS
A. Parcel Locker: USPS approved; aluminum with two parcel lockers. As supplied by
Salsbury Industries.
1. Model:3302.
2. Compartment Depth: 15 Inches (381 mm).
3. Pedestal: 14.5 inches (368 mm) high pedestal.
4. Cabinet: Heavy duty aluminum sheet.
5. Locks: 5-pin cylinder cam lock with spring -loaded cover on each unit, 3 keys each
lock; USPS-1172 91OB lock.
6. Finish: Powder coated.
a. Color. Sandstone - standard.
b. Color. Bronze -standard.
c. Color. Green - standard.
d. Color. Black - standard.
e. Color. While - standard.
f. Color. Gray - standard (for replacement units)
7. Box Identifications: Self-adhesive with black text on silver background; weather
resistant.
PART 3 EXECUTION
3.1 EXAMINATION
A. Verify that cast concrete pads are correctly located, afigned, and sized for mailboxes.
3.2 PREPARATION
A. Clean surfaces thoroughly prior to installation.
3.3 INSTALLATION
A. Install in accordance with manufacturers instructions.
B. Align, plumb, and level; anchor in accordance with manufacturer's requirements.
10550-3
3.4 CLEANING
A. Clean surfaces with mild dish detergent. Do not use harsh abrasive cleaners. Lubricate
locks with graphite type lubricants only.
3.5 PROTECTION OF INSTALLED PRODUCTS
A. Take care to protect finishes during installation and construction process. Touch-up,
repair or replace damaged products before Substantial Completion.
END OF SECTION
105504