HomeMy WebLinkAboutSUBMITTED PAPPERSFROM : 5 PHONE NO. : 462114E SCANNED } BY St. Lucie County REQUEST FOR 30 DAY TEMPORARY POWER RELEASE DATE• St Lucie County Comm. Devel. Dept. Code Compliance Division 9/2198 - 2300 Virginia Avenue Fort Pierce, FL 34982-6652 PERMrr NUMBER: Ph. (561) 462-2165 Few 561 i462-1735 PROPERTY ADDRESS: OCT 7 1998 IUI Lot 22 Block 41 6542 Gaviota CflMMI1NITY ❑FVFI (1PMFNT THE UNDERSIGNED HEREBY REQUEST RELEASE OF ELECTRICAL POWER TO THE ABOVE DESCRIBED PROPERTY, FORA PERIOD NOTTO EXCEED THIRTY (30) DAYS, FOR THE PURPOSE OF TESTING SYSTEMS AND EQUIPMENT IN PREPARA- TION FOR FINAL INSPECTION, IN CONSIDERATION OF APPROVAL OF THIS REQUEST WE HEREBY ACKNOWLEDGE AND AGREE AS FOLLOWS: 1. This temporary power release is requested for the above stated purpose only, and there will be no occupancy of arty type, other than that permitted by construction during this time period. 2. As witness by our signatures, we hereby agree to abide by all terms and conditions of this agreement, including Building Division Policy, which Is Incorporated herein by reference. 3. All conditions and requirements listed In the attached document entitled "Requirements for 30 Day Power for Testing" have been fulfilled and the premises is ready for compliance inspection. We hereby release and agree to hold harmless, St. Lucie County, and their employees from all liabilities and claims of any type or nature which may arise now or In the future out of this transaction, Including any damages -which may be Incurred due to the disconnection of electrical power in. the event of violation of this agreement. Wynne Development Corporation -Joe 's Electric wl I ELECTRICAL LOAD CALCULATIONS UNIT it 1 1820 SF @ 3 VA 5400 VA TWO 20 A APPLIANCE CKTS 3000 LAUNDRY 1500 DRYER 5000 RANGE 12000 WI -I 4500 DW 1200 TOTAL 32660 VA PIRST 10 KVA a 100% - 10000 X 1. = 10000 VA REMAINDER @ 40% - 22660 X .40 = 9064 TOTAL 19064 VA A/C HEAT @ 100% 5000 TOTAL 24064 VA 24064 240 = 100 AMPS USE 100 AMP SERVICE FRASER ENGINEERING AND TESTING, INC. 350/ INDUSTRIAL 33rd STREET • FORT PIERCE • FLORIDA - 34946 VERO BEACH (561) 567-6I67 FORT PIERCE (56I) 46I-7SM STUART (56I) 2M77I 1 FT. PIERCE 14M233.9011 Report i of DENSITY OF SOIL IN PLACE ' ASTM D2922. CLIENT: Wynne Development Corporation DATE: 10/14/98 CONTRACTOR Client PERMfR<#-i9809045430 SITE: 6542 Gaviota; Spanis Lakes, Fairways Lot 22, Bldg. 41- Slab Area DENSITY TEST DATE _ MOLS1'URE-DENSTI'Y RELATIONSHIP INPLACE DRY PERCENT TEST MAX. NO. TESTED LOCATION ELEVATION NO. DRY WT. DENSITY COMPACTION 155 10/14/98 S.W. Comer 0 -1' .101 124.2 123.3 99.3 Center 122.7 98.8 N.E. Comer 123.1 99.1 ALL ELEVATIONS BELOW SLAB GRADE Copies: Client - I RespectfWly CODnty Building j FRASER E R — r OC7 � 5 98 IS 1 f:A F"'Qoo f�1 �9L / f•I 1o. 1 � '7e•a..•69'� Y � •-'er't---- - J k1AaI"7T�TL'�IC I�7t�;'' - 1 it C,.f b Fla FCP- No. f6178 O0NMM1E. Baa AM ABR WILT TEstw W AI 166.00' 66 GAVIOTA 10 WITNESS CORNER SET I.R. & CAP 0 10 20 GRAPHIC SCALE IN FEET LOT 21 BLOCK 41 MIN. SETBACK REO, FRONT SIDES _ CNR SIDES REAR — — ZNG. TECH. LOT 17 BLOCK 41 0 0 O N t7 I� M O1 DO z I NO'22'28"E 55.00' 6 10' UTILITY EASEMENT a , Ld N WITNESS CORNER ____ 70' SET I.R. & CAP 7.0' r----------- 11 GARAGE I Li o PROPOSED UNIT 1 PROPOSED F.F.E. 25.58 0 lop,> LOT 23: ti LOT 22 BLOCK 41 BLOCK 41 w M 1 41I:00' n I N N c a SO'22'28"W 55.00' ` SET I.R. & CAP SET I,R, & CAP 20' UTILITY EASEMENT LOT 16 LOT 15 BLOCK 41 BLOCK 41 I LEGEND BEARINGS BASED ON CENTERLINE OF GAVIOTA, AS CAP PLASTIC CAP STAMPED LB#44286 SHOWN, HAVING A BEARING OF N 00'22'28" E PER PLAT. O.R. BOOK OFFICIAL RECORD BOOK j CENTERLINE DESCRIPTION I.R. IRON ROD LOT 22, BLOCK 41:OF SPANISH LAKES FAIRWAYS - NORTHEAST PHASE ACCORDING TO THE PLAT THEREOF AS RECORDED IN I ell, PROPOSED ELEVATION PLAT BOOK 35, PA'GES 5 & 5A - 5C, OF THE PUBLIC RECORDS P.C. POINT OF CURVATURE OF ST. LUCIE COUNTY, FLORIDA. P.C.P. PERMANENT CONTROL POINT FLOOD ZONE "X" PER F.I.R.M. P.R.M. PERMANENT REFERENCE MONUMENT MAP NUMBER 1211fCO175F F.F.E. FINISH FLOOR ELEVATION EFFECTIVE DATE: AUG. 19, 1991 LANDSRESER A71O N HEREON WERE NOT ABSTRACTED FOR RIGHT CO OF WAY. RESERVADONS,ACTiEEI@ITS, AND/OR EASElAER75 OF RECORD. SUCH BY:✓� /� Z%- Sad' INFORMATION, F DESIRED, SHOULD BE OBTAINED AND CONFIRMED BY BRETT CULPEPPE7R, P.L.S. IDA CFRDFICATE NO. 3333 DATE OTHERS THROUGH APPROPRIATE 7111.E VERSCATION, NOT VAUD UNLESS SIGNED, DATED AND EMBOSSED WTH SEAL OF SIGNING SURVEYOR EPPERm dG CONSULTING ENGINEERS & LAND SURVEYORS 2980 SOUTH 25th STREET FORT PIERCE, FLORIDA 34981 561-404-3537 CERTIFICATION NO. L.B. 4286 i BOUNDARY SURVEY WYNNE BUILDING CORPORATIONCT REF. JOB NO. DRAWN BY DATE SURVEY NO. 1 85140 D.F. 9-21-98 2166-22-41 F.B.;PG. CALCULATED'BY SCALE SHEET NO. D.F. , 1"=20' 1 OF 1 I 9 166.00' 6 GAVIOTA to , NO'22'28"E 55.00' r o � 1 0 10' UTILITY EASEM T o N N � WITNESS CORNER WITNESS CORNER SET I.R. & CAP 7 n' SET I.R. & CAP q ,0 20 GRAPHIC SCALE IN FEET LOT 21 BLOCK 41 it 0 0 O C4 M 1� M CA DO Z ,2.IY 5.0' v n FORMBOARDS ONLY FOP OF FORMBOARDS EL 25.80 LOT 22 n BLOCK 41 c 0 M S072'28"W. 55.00' SET I.R. & CAP 20' UTILITY EASEMENT LOT 16 BLOCK 41 0 0 0 w R N M n M C7 OD En LOT 23 BLOCK 41 SET I.R. & CAP LOT 15 BLOCK 41 A�CoMMUNl NTST. LUCINTY FL BUILDING PERMIT NO.-98090454� LEGEND BEARINGS BASED ON CENTERLINE OF GAVIOTA, AS CAP PLASTIC- CAP STAMPED LB#4286 SHOWN, HAVING A BEARING OF N 00-22'28" E PER PLAT. O.R. BOOK OFFICIAL RECORD BOOK CENTERLINE DESCRIPTION I.R. IRON ROD LOT 22, BLOCK 41 OF SPANISH LAKES FAIRWAYS - NORTHEAST PHASE ACCORDING TO THE PLAT THEREOF AS RECORDED IN PROPOSED ELEVATION PLAT BOOK 35, PAGES 5 & 5A - 5C, OF THE PUBLIC RECORDS P.C. POINT OF CURVATURE OF ST. LUCIE COUNTY, FLORIDA. P.C.P. PERMANENT CONTROL POINT FLOOD ZONE "X" PER F.I.R.M. REVISED 10-15-98 P.R.M. PERMANENT REFERENCE MONUMENT MAP NUMBER 12111CO175F ADDED FORMBOARDS F.F.E. FINISH FLOOR ELEVATION EFFECTIVE DATE: AUG. 19, 1991 LMIDS SHOW HEREON HERE NOT ABSTRACTED FOR RGH OF WAY. RESERVATOMAQMIENTS, MD/OR EA59MNTS OF RECORD. SUCH BY: MCINATION, F DESIRED. SHOIAD BE OBTAINED AND CONFRRMED BY BRETT CULPEPPER, P.L.S. FLORIDA CERTIFICATE NO. 3333 DATE OTHERS THROUGH APPROPRIATE TITLE VERFICATCN. NOT VAUD UNLESS SIGNED, DATED AND EMBOSSED WTH SEAL OF SIGNING SURVEYOR CULP CTIRENING�INQ CONSULTING ENGINEERS & LAND SURVEYORS 2980 SOUTH 25th STREET FORT PIERCE. FLORIDA 34981 561-484-3537 CERTIFICATION NO, L.B. 4286 BOUNDARY SURVEY WYNNE BUILDING CORPORATION, REF. JOB NO. I DRAWN BY I DATE I SURVEY NO. 85140 D.F. 6-12-98 2166-22-41 F.B..PG. PALCULATED B SCALE SHEET N0. 9833-12 D.F. V=20' 1 OF 1