HomeMy WebLinkAboutSUBMITTED PAPPERSDATE: FEES DUE:11�-DTrRECE1PT#: I Permit #: Qi
- t Planning & Development Services Department
Building & Code Regulation Division
®" SDAN
e � 2300 Virginia Avenue NED
Ft. Pierce, FL 34982-5652 By
Tel.772-462-1553 St Lucie Canty
APPLICATION FOR ROOF PERMIT
�/ SEE REVERSE 90E FOR IN U ONS //
1. Location/Site Address: 42� Mz r�l) G%�iGe
2. Parcel ID Number: �A4 _/*-000,S -000 —9
Office Use
Only
I Section
Townshi
I Range
I Map Page
I Zoning
Land Use
Initials
3
3. Description of Projector Work Activity: lk;�e/"007- %SOiI/% '61JLZ
/y 4. Total Roof Area (square feet): 00 5. Roof Pitch: A����/v�
6. Type of Roof: [ Fiberglass Shingle [ ] Concrete Roof Tile [ ] Wood Shake / Shingle
7.
[ ] Tar & Gravel [ ] Modified Bitumen [ ] Other
[ y�Product Approval required for all types of Roofing Material (2 Sets)
] All Commercial Roofing requires design by an Engineer or Architect (2 Sets) with Product
Approval attached
** Roof Mitigation per F.S. 553.844 will be required.
Owner Information / %� / 8. Contractor Information
Name: ✓i'J IVel 04' �Clit'/f V�/ttv Address: 2-5-07 4Q" 2 i11,
r7�Gi�771J9(JC/i Z
City: /�/�/(f' State: _
Zip: 0-5% Phone:
Z Reg/Cert#: Cf'. CO5Sl93
County Cert #• 19fd, i
Business Name: &Cl/J
Cell Phone: 772- 71' 9 47
9. Value of Construction: $
**Note Dry -in and Final Inspection Required. Additional inspection may be required per Product Approval.
CONTRACTOR/OWNER'S AFFIDAVIT: I certify that all of the information contained in Otis application is correct and that all work will be
done in cum liance with all applicable laws regulating construction and zoning.
PRINT QU IE /OWNERS NAME , SIGNATURF O QUALIFIEWOWnIt
STATE OF FLORIDA, COUNTY OF % "If
ACKNOWLEDGED BEFORE ME THIS DAYOF__1z 20�BY
PERSON LL KNO TO ME OR HAS PRODUCED/ AS ENTHtICATION
HARRY .SHAMROTH
SI F NOTAR /]y/TYPE OR PRINT NAME OF NOTARY ?:4 +_ C OMMISSION # DD9787S3r3
COMMISSION NUMBER_ �L�/ 3 EXPIRES April 05, 2074
(407)39MIS3 FIwWallotmy%awice.c
NOTICE TO OWNER: FAILURE TO RECORD A NOTICE OF COMMENCEMENT MAY RESULT IN YOUR PAYINGTW
FOR IMPROVEMENTS TO YOUR PROPERTY. IF YOU INTEND TO OBTAINFINANCING, CONSULT YOUR LENDER OR
ATTORNEY BEFORE RECORDING YOUR NOTICE OF COMMENCEMENT.
Revised 4262010
INSTRUCTIONS
Please complete all information in the space provided. All information must be printed (use black or blue ink
only) or typed. This roof permit application is to be used only for those activities that are not otherwise included
under a primary building permit. This application may not be used for any activity that includes structural
alteration. Building activities involving structural alteration, in addition to the roof work, must be permitted
through the regular building permit review process. The information to be provided with this application
includes:
1. Location/Site Address
2. Parcel ID Number
3. Description of Project or Work Activity
4. Total Roof Area
5. Type of Roof
6. Owner Information
7. Contractor Information
8. Value of Construction
Indicate the street address or general location of the
property where the building activity is taking place.
Indicate the tax identification number of the property where
the building activity is taking place.
Completely describe the building activity to take place.
Please indicate if tear -off or shingle over shingle etc.
Indicate total roof area to be affected by this permit. Also
indicate the pitch of the roof, expressed as a standard ratio
of run rise.
Indicate the type of roof being repaired or resurfaced.
Indicate the name and address of the owner of the property
on which building activity is taking place.
Indicate the State of Florida registration number (if
applicable), St. Lucie County contractor license number and
the name of the business doing the work.
Indicate the total value of the work to take place. Total cost
of construction includes all material and labor costs
associated with the building/construction activity.
Construction value is used to determine the permit fee. St.
Lucie County reserves the right to question and/or modify
the indicated value of construction if it is demonstrated that
the submitted figures are not consistent with similar types
of construction.
This application can be submitted to St. Lucie County Building and Zoning, 2300 Virginia Avenue, Fort Pierce,
FL 34982. All permit applications must be filled out completely before submission. No applications will be
accepted for processing after 4:30 P.M. For assistance in completing this application, please call (772)
462-1553, during regular office hours (8:00 AM - 5:00 PM), Monday through Friday.
Upon issuance of this permit, required inspections can be scheduled by calling (772) 462-1261.
St. Lucie County Roof Permit Application rev. 3/1@009
JOSEPH E. SMITH, CLERF,-r THE CIRCUIT COURT - SAINT LUCIE COX --
FILE H 3850730 OR BOI '534 PACE 1083, Recorded 07/01/2013 (1:43 AM
NOTICE OF COMMENCEMENT
Te be cemyleted when censunnin c , value exceeds $2,500.00
PERMUTE: TO FOBO a 2418-141-00054000-8
STATE OF RDRIDA COUNWOF
The undersigned herebyglves notice that Imprawmem will be made to certain real property, and In accordance with Chapter Tl3, Florldo
Statutes, the followinglnformationls provided in this Notloe of Commencement.
1EGAILDESCRIPRON DFPROPERW (AND SDIEETADORESS,IFAVAIGIBLE):
1215 HARTMAN RD, FORT PIERCE SEC: 18 7WN: 35S RANGE 40E
GENERAILDESCMPTIONOFIMPROVEMENTRE-ROOF
OWNER INFORMATION OR
Name: KAREN S. GE
Address: 25071AZYW
Nameand address of fee
CONTRACTOR'S NAME: GARY MARZO, INC. Phone No.: fT72) 871-2489
Address: B61 A- SW LAKEHURST DRWE.PORT SAINT LUCIE FL. 34983
SURETY COMPANY (if applicable, acon Ofthe payment bond is attached):
Nameand address:
Phone No.: Bond amount:
LENDER'S NAME: Phone No.:
PenomwIMnNe StateofFbrOadeslg:uwdbYowneruponwlwmmre sceotherdo memsmayboumdaspr dedby Sewon T13.13
(1) la) T, Florida statutes:
No.:
In addition to himselfor herself, owner designates of to
receive a copy of the Uenoes Notice as provided in Section 713.13111(b), Florida Statues.
Phone number of person or From, designated by Owner.
Expiration date On Notice of Commerm menD
(the expiratbndate maynot ba before the completion of mnsWNonand Mal payment to the contractor, butwill be Syearfrom the date of
recording unless different data Is specified):
."ANINCYC)OWNE0. NP AOE TN N RT E%PIR M ICE F ARE IOE
IMPROPER PAYMEIMS UNDER NAMR 713, PART TWICE
MPROVTMENTSTO YOUR PROPEM, A NOTICE OF COMMENCEMENT MUST BE RECORDED
the forefoingand met me facts In It me true to the beat of my knowledge and belief.
/a I e `g E%PIRES:Apr95,2015
sigmm sThle office 9 srawMT/ Bvtlal DmgWigtaaTgerim
Thefoxming im,bumentrsacknowledged before methls.�/ �dayof :/.LiiiO.
Personally Lnown produced Nentnicatlon 0
7ypeof1centAlutbn produced
(Pdnt Type, orStamp CommOsloned Name of Notary)
TABLDIDIdILFomuWmv Applicada.rTmauWotice Of CommencrmemDOca Rev. 9115/II
-STATE Of FLORIDA
ST. LUCIE COUNTY
Property Appraiser - St.Lucie ! '
tty, FL
Page 1 of 1
PROPERTY RECORD
CARD
Michael Getety Jr Record: 1 of 3
"Prev Next »
Spec.Assmnt Taxes
Exemptions Permits Home Print
Property Identification
1�UCIECC
Site Address: 1215 HARTMAN RD
ParceIID:
2418-141-0005-000-8
a�G�
Sec/Town/Range: 18 :35S :40E
Account #:
27267
m
Map ID: 24/18N
Use Type:
M-F < 10U
Zoning: RM-9
City/Cnty:
St Lucie County
4wk
Ownership and Mailing
Owner. Michael Gaiety Jr Karen S Getety
Address:
2507 Lazy Hammock Ln
Fort Pierce FL 34981-5411
Sales Information
Date
Price
Code
Deed
Book/Page
9/23/2009
388000
0112
SP
3133 / 2125
12/31/2008
100
01
CT
3051 / 0553
5/10/2002
210000
00
WD
1607 / 2444
11/3/2000
170000
00
WD
1341 / 1351
11/1/1984
220000
00
CV
0449/0471
Legal Description
18 35 40 FROM NE CDR OF SEC RUN S ALG E SEC LI 1899.22 FT
FOR POB, TH S 88 DEG 45 MIN W 265 FT, TH S
More...
Assessment 2012 Total Land and Building
2012 Final: 80700 Land Value: 26000 Acres: 0.96
Assessed: 80700 Building Value: 54700
Ag.Credit: 0 Finished Area: 5283 SgFt
Exempt:
Taxable:
Taxes: 1632.67
BUILDING INFORMATION
Exterior Features
View:
-
RoofCover:
SA-Asph Shingle
RoofStrucl:
GA - Gable
ExlType:
MFH - M.F. LOW RIS
YearBlt:
1955
Frame:
-
Grade:
D-D
EffYrBlt:
1955
PrimeWall:
BS - CB Stucco
StoryHghl:
0010 -1 Story
No.Units:
2
SecWall:
-
Interior Features
BedRooms:
2
Electric:
AV -AVERAGE
PrmintWall:
PN-PN
FullBath:
2
HeatType:
-
AvgHt/Fl:
STD
1/213ath:
0
HeatFuel:
-
Prm.Flors:
TZ-Terrazo
%A/C:
0
%Heated:
0
%Sprinkled:
0
Special Features and Yard Items
Land Information
Type Y/S
Qty. Units Qual.
Cond. YrBIL
No. Use Type
Type
Measure Depth
1 0800-M-F<IOU
150-Unit
13
THIS INFORMATION IS BELIEVED TO BE CORRECT AT THIS TIME BUT IT IS SUBJECT TO CHANGE AND IS NOT WARRANTED
J
http://www.paslc.org/paslc/prc.asp?prclid=241814100050008 7/3/2013
MIMI E
s
BUILDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE
Iko Industries Ltd.
40 Hansen Rd. S.
Brampton, Ontario CANADA
L6W3H4
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
www.nda midade.eov/build in
FILE COPY p7
l�%`OVA
SCOPE: �-Perw. 7, -1-
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
CDESC- RIRTI0N Ca—zaq Rd -
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. )f any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and -shall be available for ins ection at the job site at the request of the Building Official.
This revises NOA# 10-0913.02 and consists of pages 1 through 4.
The submitted documentation was reviewed by Alex Tigera.
QV1Dk-N`ej 11-05Vh09-
MIAMADADECOUNiY)ExPI[fit108te: 0 71-6�
rApproval Date: a 07/07/Y1
Page 1 of 4
ROOFING ASSEMBLY APPROVAL
Cateeory
Roofing
Sub-Caterorv:
Asphalt Shingles
Materials
Laminate
Deck Type:
Wood
SCOPE
This approves a roofing system using Cambridge AR asphalt shingles manufactured by IKO Industries Ltd. as
described in Section 2 of his Notice of Acceptance.
PRODUCT DESCRIPTION
Product Dimensions Test
Product Description
Specifications
Cambridge AR 13 3/4" x 40 7/8" TAS 110
A heavy weight, fiberglass reinforced
laminate asphalt shingle.
MANUFACTURING LOCATION
1. Kankakee, IL
EVIDENCE SUBMITTED
Test Aeenev Test Identifier
Test Name/Report Date
PRI Construction Materials Inc. IKO-050-02-01
TAS 100 12/21/09
FM Approvals 3041689
ASTM D 3462 02/23/11
FM Approvals 3036971
ASTM D 3161'(TAS-107) 01/04/09
FM Approvals 3042673
ASTM E 108 04/12/1 l
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory
for fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 9B-72 of the Florida Administrative Code.
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3. The manufacturer shall provide clearly written application instructions.
4. -Exposure and course layout shall be in compliance with Detail 'A', attached.
5. Nailing shall be in compliance with Detail'B', attached.
NOA No.: 11-0517.09
Expiration Date: 05/05/16
Approval Date: 07/07/11
Page 2 of 4
LABELING
1. Shingles shall be labeled with the Miami -Dade Seal as Seen below, or the wording "Miami -Dade County
Product Control Approved".
BUILDING PERMIT REQumEMENTs
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 11-0517.09
Expiration Date: 05/05/16
Approval Date: 07/07/11
Page 3 of 4
FIRST COURSE
DETAIL A
CAMBRIDGE AR COURSE LAYOUT
3E OF ROOF
Note: Roofing Cement not shown in this IayouL
ThIs drawing later course layout Dory. See DetailS
for nailing and cement placement details.
THIRD COURSE
SECOND COURSE
DETAIL B
CAMBRIDGE AR
40 8'
13 4"
ti erg
END OF THIS ACCEPTANCE
m
EXPOSURE
NOA No.: 11-0517.09
MIAMpDADE COlIN7Y
Expiration Date: 05/05/16
.,.r , Approval Date: 07/07/11
Page 4 of 4
M IAMI, XE AMI-DADE COUNTY
mma PRODUCT CONTROL SECTION
BUDDING AND NEIGHBORHOOD COMPLIANCE DEPARTMENT (BNC) 11805 SW 26 Street, Room 208
BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/buildine/
Polyglass USA Inc.
150 Lyon Drive
Fernley, NV 89408
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County BNC - Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AFIJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BNC
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Polyglass Polystick Underlayments
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall
be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA # 09-0806.07 and consists of pages 1 through 8.
The submitted documentation was reviewed by Alex Tigera.
J t�
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 1 of 8
ROOFING COMPONENT APPROVAL
Category Roofing
Sub -Category: Underlayment
Material: SBS , APP Self -Adhering Modified Bitumen
PRODUCTS DESCRIPTION:
Product
Dimensions
Polystick NITS
Roll:
underlayment
65'8" x 3'3 %,,
Manufacturing Location
60 mils thick
#2
Test
Specification
TAS 103
Product
Description
A homogeneous, rubberized asphalt
waterproofing membrane, glass fiber reinforced
with polyolefinic film on the upper surface for
use as an underlayment for metal roofing, roof
tile, slate tiles and shingle underlayment.
Polystick IR-Xe
Roll:
TAS 103 and
A fine granular/sand top surface self -adhering,
underlayment
65' x 3'3 =/g"
ASTM D 1970
APP polymer modified, fiberglass reinforced,
Manufacturing Location
Or 65' x 3'
bituminous sheet material for use as an
#1 & #2
80 mils thick
underlayment in sloped roof assemblies.
Designed as an ice & rain shield and as a flat
roof tile underlayment.
Polystick TU
Roll:
TAS 103 and
A heavy granuled surface self adhering, APP
underlayment
32' 10" x 3'3 '/,"
ASTM D 1970
polymer modified, fiberglass or polyester
Manufacturing Location
100 mils thick
reinforced, bituminous sheet material for use as
#1 & #2
an underlayment in sloped roof assemblies.
Designed as a a roof tile underlayment.
Polystick TU Plus
Roll:
TAS 103 and
A non -wicking fabric surfaced, self -adhering,
underlayment
65' x 3'3-'/s"
ASTM D 1970
APP polymer modified, fiberglass reinforced
(Facer of Membrane
80 mils thick
with a high strength polyester fabric, bituminous
with surface printing)
sheet material for use an an underlayment in
Manufacturing Location
sloped roof assemblies. Designed as a metal
#1 & #2
roofing and roof tile underlayment.
Polystick TU P
Roll:
TAS 103 and
A rubberized asphalt waterproofing membrane,
underlayment
32' 10" x 3'3 3/,"
ASTM D 1970
glass-fiber/polyester reinforced, with a granular
Manufacturing Location
130 mils thick
surface designed for use as a tile roof
#2
underlayment.
Polystick Tile Pro
Roll:
TAS 103 and
A rubberized asphalt self -adhering, glass -
Manufacturing Location
6 P x 3'3 '/,"
ASTM D 1970
fiber/polyester reinforced waterproofing
#2
60 mils thick
membrane. Designed as a metal roofing and roof
tile underlayment.
NOA No.: 11-0601.10
Expiration Date: 09/13/16
nuaiwapEcouNrr
..., ,
Approval Date: 09/15/11
Page 2 of 8
PRODUCTS DESCRIPTION:
Test
Product
Product Dimensions
Specification Description
Polystick Dual Pro Roll:
ASTM D 1970 A rubberized asphalt self -adhering, glass -
Manufacturing Location 61' x 3'V4"
fiber/polyester reinforced waterproofing
#2 60 mils thick
membrane, specific for use as a high
temperature underlayment. Designed as a metal
roofing.
MANUFACTURING PLANTS:
1. Hazelton, PA
2. Winter Haven, FL
EVIDENCE SUBMITTED:
Test Agency
Test Identifier
Test Name/Reuort
Date
Exterior Research & Design, LLC
11756.04.01-1
TAS 103
04/27/01
11756.08.01-1
ASTM D 1970
08/14/01
02202.08.05
TAS 103
08/29/05
Trinity) axD
P5110.08.07
TAS 103
08/29/07
P10870.09.08-R1
TAS 103
12/04/08
P10870.04.09
TAS 103/ASTM D4798 & G155
04/13/09
P33360.06.10
ASTM D1970
07/01/10
P33370.03.11
TAS 103
03/02/11
P36900.09.11
TAS 103/ASTM D4798 & G155
09/01/11
PRI Asphalt Technologies
PRI01111
ASTM D 4977
04/09/02
PUSA-005-02-01
ASTM D 4977
01/31/02
PUSA-018-02-01
ASTM D 2523
07/14/03
PUSA-035-02-01
TAS 103
09/29/06
PUSA-033-02-01
ASTM D 1970
01/12/06
PUSA-055-02-02
TAS 103
12/10/07
PUSA-083-02-01
TAS 103
06/30/08
PUSA-089-02-01
TAS 103/ASTM D4798 & G155
07/06/09
Momentum Technologies, Inc.
JX20117A
TAS 103/ASTM D4798 & G155
04/01/08
RX14E8A
TAS 103/ASTM D4798 & G155
11/09/09
DX23D8B
TAS 103/ASTM D4798 & G155
02/18/10
DX23D8A
TAS 103/ASTM D4798 & 0155
02/18/10
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 3 of 8
INSTALLATION PROCEDURES:
Deck Type 1: Wood, non -insulated
Base Sheet: One or more plies of ASTM D 226 Type 11 or ASTM D 2626.
Fastening: Per FBC 1518.2 & 1518.4 Nails and tin caps 12" grid, 6" o.c. at a minimum 4" head lap. (for
base sheet only)
Membrane: Polystick membranes self -adhered.
Surfacing: None
1. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels,
and sweep the deck thoroughly to remove any dust and debris prior to application.
2. Place the underlayment over metal drip edge in accordance with RAS 111.
3. Place the first course of membrane parallel to the eave, rolling the membrane to obtain maximum contact.
Remove the release film as the membrane is applied.. All side laps shall be a minimum of 3 ''/2" and end
laps shall be a minimum of 6." Roll the membrane into place after removing the release strip. Vertical
strapping of the roof with Polystick is acceptable. Membrane shall be back nailed in accordance with
applicable building code.
4. When applying the membrane in the valley, start at the low point and work to the high point, rolling the
membrane from the center outward in both directions.
5. For ridge applications, center the membrane and roll from the center outward in both directions.
6. Roll or broom the entire membrane surface so as to have full contact with the surface, giving special
attention to lap areas.
7. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product
Control Notice of Acceptance.
8. All protrusions or drains shall be initially taped with a 6" piece of underlayment. The flashing tape shall be
pressed in place and formed around the protrusion to ensure a tight fit. A second layer of Polystick shall be
applied over the underlayment.
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 4 of 8
GENERAL LIIVHTATIONS:
1. Fire classification is not part of this acceptance.
2. Polystick MTS, TU Plus, and Tile Pro may be used in asphaltic shingles, wood shakes and shingles, non-
structural metal roofing, roof tile systems and quarry slate roof assemblies. IR-Xe, TU, and TU P may be used
in all the previous assemblies listed except metal roofing. Dual Pro may be used in all the previous
assemblies listed except roof tile systems.
3. Deck requirements shall be in compliance with applicable building code.
4. Polyglass Polystick membranes shall be applied to a smooth, clean and dry surface. The deck shall be free of
irregularities.
5. Polyglass Polystick membranes and underlayments shall not be adhered directly over a pre-existing roof
membrane as a recover system.
6. Polyglass Polystick membranes shall not be left exposed as a temporary roof for longer than the amount of
days listed in the table below after application. Polyglass reserves the right to revise or alter product
exposure times; not to exceed the preceeding maximum time limitations.
Exposure Limitations da
MTS
H1-Xe
TU
TU Plus
TU P
Tile Pro
Dual Pro
Winter Haven, FL.
180
180
180
180
1 180
1 180
180
Hazelton PA.
N/A
30
30
180
1 N/A
I N/A
N/A
7. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 9B-72 of the Florida Administrative Code.
S. In roof tile application, data for the attachment resistance of roof tiles shall be as set forth in the roof tile
manufacturer's Notice of Acceptance. Polystick TU and TU Plus may be used in both adhesive set and
mechanically fastened roof tile applications. Polystick IR-Xe, and Tile Pro are limited to mechanically
fastened roof tile applications. Polystick MTS is limited to mechanically fastened with battens roof tile
applications. Polystick TU P may be used in both adhesive set and mechanically fastened roof tile
applications with the exception of mortar set tile applications.
9. The maximum roof slope for use as roof tile underlayment for (direct -to -deck) tile assemblies shall be as
follows: (See Table Below)
Tile Profile
Polystick MTS
Polystick IR-Xe
Polystick TU, TU
Plus, TU P, Tile Pro
Fiat Tile
Prohibited without battens
5:12
No limitation
Profiled Tile
Prohibited without battens
Prohibited
No limitation
The above slope limitations can be exceeded only by using battens and counter battens in accordance with the
Approved Tile System Notice of Acceptance and applicable Florida Building Code requirements. Battens
are required for both loading and installation of tiles at all times.
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 5 of 8
GENERAL LIMITATIONS: (CONTINUED)
10. Care should be taken during the loading procedure to keep foot traffic to a minimum and to avoid dropping of
tile directly on the underlayment. Refer to Polyglass' Tile loading detail below for loading procedure for all
underlayments except Polystick MTS which shall be loaded onto battens.
W
11. Refer to prepared roofing system Product Control Notice of Acceptance for listed approval of this product
with specific prepared roofing products. Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro
may be used with any approved roof covering Notice of Acceptance listing Polystick MTS, IR-Xe, TU, TU
Plus, TU P, Dual Pro and Tile Pro as a component part of an assembly in the Notice of Acceptance. If
Polystick MTS, IR-Xe, TU, TU Plus, TU P, Dual Pro and Tile Pro is not listed, a request may be made to the
Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval
provided that appropriate documentation is provided to detail compatibility of the products, wind uplift
resistance, and fire testing results.
LABELING:
1. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo,
city and state of manufacturing facility and the following statement: "Miami -Dade County Product Control
Approved" or the Miami -Dade County Product Control Seal as shown below.
MIAMHX40ECOUNW
BUILDING PERMIT REQUIREMENTS:
Application for building permit shall be accompanied by copies of the following:
1. This Notice of Acceptance.
2. Any other documents required by the Building Official or applicable building code in order to properly evaluate
the installation of this materials.
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 6 of 8
POLYGLASs GENERAL APPLICATION GUIDELINES FOR POLYSTICK MEMBRANES:
1. Polyglass does accept the direct application of Polystick underlayment membranes to wood decks. Installers
are cautioned to refer to applicable local building codes prior to direct deck installation to ensure this is
acceptable. Please also refer to applicable Product Data Sheets of the corresponding products.
2. All rolls, with the exception of Polystick TU Plus should be back -nailed in selvage edge seam as per Polyglass
Back Nailing Guide. Nails shall be, 11 gauge ring shank type, applied with a minimum 1" metal disk as
required in Dade County or simplex type nail as otherwise allowable in other regions, at a minimum rate of
12" o.c. Polystick TU Plus should be back nailed in designated area marked "nail area, area para clavar" on
the face of membrane, with the above stated nails and/or disks. The head lap membrane is to cover the area
being back -nailed. (Please refer to applicable local building codes prior to installation.)
3. All seal lap seams (selvage laps) must be rolled with a hand roller to ensure full contact.
4. All fabric over fabric; and granule over granule end laps, shall have a 6" wide, uniform layer of Polyglass
Polyplus 55 Premium Modified Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement,
Polyglass PG500 MB Flashing Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251
Premium Wet/Dry Elastomeric Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel
Grade mastic, applied in between the application of the lap. The use of mastic between the laps does not apply
to Polystick MTS.
5. A maximum of 6 tiles per stack are allowed when loading tile on the underlayments. Refer to the Polyglass
Tile Loading Guidelines. See General Limitations #9 and #10.
6. Battens and/or Counter -battens, as required by the tile manufacturers NOA's, must be used on all projects for
pitch/slopes of T712" or greater. It is suggested that on pitch/slopes in excess of 6'/<"/12", precautions
should be taken, such as the use of battens to prevent tile sliding during the loading process.
7. Minimum cure time after membrane installation & before loading of roofing tiles is Forty -Eight (48) Hours.
& Polystick membranes may not be used in any exposed application such as crickets, exposed valleys, or
exposed roof to wall details.
9. Repair of Polystick membranes is to be accomplished by applying Polyglass Polyplus 55 Premium Modified
Flashing Cement, Polyglass Polyplus 50 Premium MB Flashing Cement, Polyglass PG500 MB Flashing
Cement, Mule -Hide 241 Premium Modified Flashing Cement, Mule -Hide 251 Premium Wet/Dry Elastomeric
Flashing Cement, or Mule -Hide 421 Mod Bit Flashing Adhesive Trowel Grade mastic to the area in need of
repair, followed by a patch of the Polystick material of like kind should be set and hand rolled in place over
the area needing such repair. Patching membrane shall be a minimum of 6 inches in either direction. The
repair should be installed in such a way so that water will run parallel to or over the top of all laps of the
patch.
10. All self -adhered membranes must be rolled to ensure full contact with approved substrates. Polyglass
requires a minimum of 40 lbs for a weighted roller for the rolling of the field membrane. Hand rollers are
acceptable for rolling of patches or small areas of the roof. Brooming may be used where slope prohibits
rolling.
11. All approved substrates should be dry, clean and properly prepared, before any application of Polystick
membranes commences. An approved substrate technical bulletin can be furnished upon request. It is
recommended to refer to applicable building codes prior to installation to verify acceptable substrates.
12. The Polyglass Miami -Dade Notice of Acceptance (NOA) approval for Polystick membranes and
PolyProtector UDL can be famished upon request by our Technical Services Department by calling 1 (800)
894-4563.
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11
Page 7 of 8
13. Questions in regards to the application of Polyglass products should be directed to our Technical Services
Department at 1 (800) 8944563.
14. Polyglass recommends that applicators follow good roofing practices and applicable procedures as outlined
by the National Roofing Contractors Association (NRCA).
PLEASE CHECK wrM LOCAL BUILDING CODES REGARDING LIMITATIONS OF SPECIFIC
APPLICATIONS. LOCAL CODES MAY SUPERSEDE POLYGLASS REQUIREMENTS AND
RECOMMENDATIONS.
END OF THIS ACCEPTANCE
NOA No.: 11-0601.10
Expiration Date: 09/13/16
Approval Date: 09/15/11