Loading...
HomeMy WebLinkAboutSUBMITTED PAPERSIK r O MB. NO. 3067.0077 8T� p_#lS�lSl� ELEVATION CERTIFICATE �S¢'re;May3,,,996 FEDERAL EMERGENCY MANAGEMENT AGENCY NATIONAL FLOOD INSURANCE PROGRAM ATTENTION: Use of this certificate does not provide a waiver of the flood insurance purchase requirement. This form is used only to provide elevation information necessary to ensure compliance with applicable community floodplain management ordinances, to determine the proper insurance premium rate, and/or to support a request for a Letter of Map Amendment or Revision (LOMA or LOMR). Instructions for completing this form can be found on the following pages. BUILDING OWNER'S NAME SECTION A PROPERTY INFORMATION I FOR INSURANCE COMPANY USE I POLICY NUMBER STREET ADDRESS (Including Apt., Unit, Suite and/or Bldg. Number) OR P.O. ROUTE AND BOX NUMBEFr%lmt �' — COMPANY NAIC NUMBER 9801 S. Ocean Dr.. #901-2 BY OTHER DESCRIPTION (Lot and Block Numbers, etc.) St. Lot 901 Section 2, Nettles Island Project CITY STATE ZIP CODE Jensen Beach Florida 34957 SECTION B FLOOD INSURANCE RATE MAP (FIRM) INFORMATION Provide the following from the proper FIRM (See Instructions): 1. COMMUNITY NUMBER 2. PANEL NUMBER 3. SUFFIX 4. DATE OF FIRM INDEX 6. BASE FLOOD ELEVATION 1 F5..FIRMZONE (in AO Zones, use depth) 120285 0311 F 8-19-91 AE 7' 7. Indicate the elevation datum system used on the FIRM for Base Flood Elevations (BFE): ❑ NGVD'29 ❑ Other (describe on back) 8. For Zones A or V, where no BFE is provided on the FIRM, and the community has established a BFE for this building site, indicate the community's BFE: I I I I I . ❑ feet NGVD (or other FIRM datum -see Section B, Item 7). SECTION C BUILDING ELEVATION INFORMATION 1. Using the Elevation Certificate Instructions, indicate the diagram number from the diagrams found on Pages 5 and 6 that best describes the subject building's reference level 7 . 2(a). FIRM Zones Al-A30, AE, AH, and A (with BFE). The top of the reference level floor from the selected diagram is at an elevation of I I I 11 10J, i❑ feet NGVD (or other FIRM datum -see Section B, Item 7). CAI -1y'llf2{4S (b). FIRM Zones V1-V30, VE, and V (with BFE). The bottom of the lowest horizontal structural member of the reference level from the selected diagram, is at an elevation of I i I I I .❑ feet NGVD (or other FIRM datum -see Section B, Item 7). (c). FIRM Zane A (without BFE). The floor used as the reference level from the selected diagram is L-❑.❑ feet above ❑ or below ❑ (check one) the highest grade adjacent to the building. (d). FIRM Zone AO. The floor used as the reference level from the selected diagram is L-❑.❑ feet above ❑ or below ❑ (check one) the highest grade adjacent to the building. If no flood depth number is available, is the building's lowest floor (reference level) elevated in accordance with the community's floodplain management ordinance? ❑ Yes ❑ No ❑ Unknown 3. Indicate the elevation datum system used in determining the above reference level elevations: ® NGVD'29 ❑ Other (describe under Comments on Page 2). (NOTE: If the elevation datum used in measuring the elevations is different than that used on the` IRM [see Section B, Item 7], then convert the elevations to the datum system used on the FIRM and show the conversion equon under Comments on Page 2.) 4. Elevation reference mark used appears on FIRM: ❑ Yes ® No (See Instructions on Page 4) 5. The reference level elevation is based on: ❑X actual construction ❑ construction drawings (NOTE: Use of construction drawings is only valid if the building does not yet have the reference level floor in place, in which case this certificate will only be valid for the building during the course of construction. A post -construction Elevation Certificate will be required once construction is complete.) 6. The elevation of the lowest grade immediately adjacent to the building is: I I.❑ feet NGVD (or other FIRM datum -see Section B, Item 7). SECTION D COMMUNITY INFORMATION 1. If the community official responsible for verifying building elevations specifies that the reference level indicated in Section C, Item 1 is not the "lowest floor" as defined in the community's floodplain management ordinance, the elevation of the building's "lowest floor" as -defined by the ordinance is: ❑ I I . feet NGVD (or other FIRM datum -see Section B, Item 7). 2. Date of the start of construction or substantial improvement FEMA Form 81-31, MAY 93 REPLACES ALL PREVIOUS EDITIONS SEE REVERSE SIDE FOR CONTINUATION SECTION E CERTIFICATION This certification is to be signed by a land surveyor, engineer, or architect who is authorized by state or local law to certify elevati& information when the elevation information for Zones Al—A30, AE, AH, A (with BFE),V1—V30,VE, and V (with BFE) is required. Community officials who are authorized by local law or ordinance to provide floodplain management information, may also sign the certification. In the case of Zones AO and A (without a FEMA or community issued BFE), a building official, a property owner, or an owner's representative may also sign the certification. Reference level diagrams 6, 7 and 8 - Distinguishing Features —If the certifier is unable to certify to breakaway/non-breakaway wall, enclosure size, location of servicing equipment, area use, wall openings, or unfinished area Feature(s), then list the Feature(s) not included in the certification under Comments below. The diagram number, Section C, Item 1, must still be entered. l certify that the information in Sections B and C on this certificate represents my best efforts to interpret the data available. I understand that any false statement maybe punishable.by fine or imprisonment under 18 U.S. Code, Section 1001. CERTIFIER'S NAME LICENSE NUMBER (or Affix TITLE COMPANY NAME CITY DATE PHONE STATE ZIP Copies should be made of this Certificate for: 1) community official, 2) insurance agent/company, and 3) building owner. COMMENTS: ' ON WITH ON PILES, SLAB BASEMENT PIERS, OR COLUMNS A V A A V ZONES ZONES ZONES ZONES ZONES REFERENCE REFERENCE BASE LEVEL REFERENCE LEVEL FLOOD LEVEL ELEVATION 7 � '. BABE "' "' REFERENCE .. ... AGACE >: BASE FLOOD FLOOD ELEVATION REFERENCEgp�gCElR GRADE ': LEVEL ELEVATION LEVEL GRADE .,!AWACENT:'� GRADE '. The diagrams above illustrate the points at which the elevations should be measured in A Zones and V Zones. Elevations for all A Zones should be measured at the top of the reference level floor. Elevations for all V Zones should be measured at the bottom of the lowest horizontal structural member. Page 2 Department of Community Affairs SN: 5048 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION FORM 60OA-93 Residential Whole Building Performance Method A CENTRAL PROJECT NAME: !BUILDER: Dennis Witherow AND ADDRESS: Lot 901-II !PERMITTING !CLIMATE Nettles Island !OFFICE: SLC !ZONE: 411 511 6! I OWNER: Keck !PERMIT NO. (JURISDICTION No.661000 CK L. New construction or addition 2. Single family detached or Multifamily 7. If Multifamily -No. of units 1. If Multifamily, is this a worst case 5. Conditioned floor area (sq.ft.) S. Predominant eave overhang (ft.) 7. Porch overhang length (ft.) 3. Glass area and type: a. Clear Glass b. Tint, film or solar screen 3. Floor type and insulation: b. Wood, raised (R-value, area ) 10.Net Wall type area and insulation: a. Exterior: 2. Wood frame (Insulation 11.Ceiling type area and insulation: a. Under attic (Insulation R-value) 12.Air distribution systems a. Ducts (Insulation + Location) 13.Cooling system 14.Heating System: 5.Hot water system: 1. New Construction attached 2. Single -Family ---- 3. V (yes/no) 4. 5. 966.00 ---- 6. 0.50 ---- 7. 0.00 _-__-- Single Pane Double Pane Ga. O.Osgft 0.00sgft ____ Bb.192.8sgft 0.00sg4t ____ 9b.R=11.00 , 966.00 soft ____ R-value) 10a-2 R=11.00, 915.00sgft_ 16.Hot Water Credits: (HR-Heat Recovery, DHP-Dedicated Heat Pump) 1.7.Infiltration practice: 1, 2 or 3 B.HVAC Credits (CF-Ceiling Fan, CV -Crass vent, HF-Whole house fan, RB-Attic radiant barrier, MZ-Multizone) 19.EPI (must not exceed 100 points) a. Total As -Built points b. Total Base points -------------------------------- -------------------------------------- I Hereby certify that the plans and specifications covered by this calcu- lation are in compliance with the Florida Energy Code. PREPARED BY:G2G------ DATE:------------- eZ aJ_= ��-------- I hereby certify that this building is in compliance with the Florida Energy Code. OWNER/AGENT: -------------------------- DATE: 11a.R.=19.00 , 966.00sgft__-_ 12a. R= 6.00 , uncond V,. Type: Central A/C EER: 10.00 14. Type: Heat Pump HSPF: 6.80 It. Type: Electric EF: 0.94 16. 17. 18. CF 19. 19a. 19b. IF 95.20 15851.85 16651.56 -------------------------------------- Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance in accordance with Section 553.908 F.S. BUILDING OFFICIAL: DATE: SUMMER CALCULATIONS _-= BASE __= 1 =_= AS -BUILT GLASS---------------- 1 ORIEN AREA x BSPM = POINTS 1 TYPE SC ORIEN AREA x SFM x SOF = POINTS N 66.70 82.2 5482.7 1 SGL TINT N 10.7 51.5 .95 914.9 1 SGL TINT N 24•.0 51.5 .97 1201.7 1 SGL TINT N 24.0 51.5 .97 1201.7 E 7.10 82.2 583.6 1 SGL TINT- E 7.1 107.1 .96 728.7 S 39.00 82.2 3205.9 1 SGL TINT S 13.0 98.3 .96 1224.7 1 SGL TINT S 13.0 99.3 .95 1209.4 1 SGL TINT S 13.0 98.3 .95 1209.4 W 80.00 82.2 6576.0 1 SGL TINT W 90.0 107.1 .98 8369.7 ------------------------------------------------------------------------------- .15 x COND. FLOOR / TOTAL GLASS = ADJ. GLASS = ADJ GLASS 1 GLASS AREA AREA FACTOR POINTS POINTS 1 POINTS -------------------------------------------------------------------------------- .15 966.00 192.80 .752 15,848.16 11,910.70 1 16,060.16 NON GLASS------------ 1 AREA x BSPM = POINTS 1 TYPE R-VALUE AREA x SFM = POINTS ------------------------------------------------------------------------------- WALLS-------------•---- 1 Ext 91.5.0 1.0 915.0 1 Ext Wood Frame 11.0 915.0 1.90 1738.5 DOORS ---------------- Ext 20.0 4.8 96.0 CEILINGS •------------- 1 Ext Insulated UA 966.0 .6 579.6 1 Under Attic FLOORS--------------- 1 20.0 4.80 96.0 19.0 966.0 1.10 1062.6 Rsd 966.0 -3.4 -3 13.4 1 Rsd Wood (Stem-UFI 11.0 966.0 -2.20-2125.2 INFILTRATION --------- 1 966.0 10.9 10329.4 1 Practice #2 966.0 10.90 10529.4 TOTAL SUMMER POINTS 1 20,717.40 1 TOTALx SYSTEM = COOLING 1 TOTAL SUM PTS MULT POINTS 1 COMPON ------------------------------------- 27,361.46 CAP x DUCT x SYSTEM x CREDIT -=-COOLING RATIO MULT MULT MULT POINTS 20,717.40 .37 7,665.44 1 27,361.46 1.00 1.070 .340 .960 8,560.53 WATER HEATING BASE __= 1 -_= AS -BUILT NUM OF x MULT = TOTAL 1 TANK VOLUME EF TANK x MULT x CREDIT = TOTAL BEDRMS 1 RATIO MULT 1 3527.0 3,527.00 1 40 .94 1.000 3302.0 1.00 3,302.00 SUMMARY BASE ___ __= AS -BUILT COOLING HEATING HEATING HOT WATER TOTAL 1 COOLING HEATING HOT WATER': TOTAL POINTS + POINTS + POINTS = POINTS : POINTS + POINTS + POINTS = POINTS 7665.4 5459.1 3527.0 16,651.56 8560.5 3989.3 1302.0 15,851.85 ################# # EPI = 95.20 # Ia NOTE:PROPOSED MINIMUM FINISHED FLOOR ELEV. TO BE 7,00! N.G.V.D. LEGAL DESCRIPTION - r"_1 LOT 901 SECTION 2 SHEET 1 OF 1 NETTLES ISLAND PROJECT PLAT BOOK 16 PAGES 1, 1A-1J SAINT LUCIE COUNTY, FLORIDA T-11 BATH HOUS EXISTING BATH HOUSE - LOT 918 4' OVERHANG _ SECTION 2 `-EXISTING RESIDENCE ' FND. #5 o FND. #5 REBAR1011' N 7003 '0 " E REBAR v� 34.64'(P&M) 6.2' 9.6 cP 0.5' 11 I LOT 901 1 • "c,}_ p SECTION 2 i EXISTING RESIDENCE! NO OVERHANG I py p W ma's, PROPOSED \ $ �� EXISTING RESIDENCE RESIDENCE � �s �� 1.0' OVERHANG LOT 902 _ -/,6"2' LOT 900 SECTION 2 / ' m \ Y gyp' SECTION 2 .... -' - PROPOSED 8' X 8,.. - . 20.2 PARKING AREA P90O_-�D' 'o �• PARKING ARE 10' 34.60'�M)0 3 .64'(P) 5.6' FND.--# REBAR FND. 5 REBAR asphalt pavement 5.62' 7C 5.58 % 5.73'A COMMON USE BENCHMARK=PAINTED ED "X" 22' PRIVATE R/W-OPEN ELEV.=5.58' N.G.V.D. SETBACKS, LOCATIO & CITY SEWER & WATER AVAILABILITIES TO BE VERIFIED BY CONTRACTOR ❑ = PLOT PLAN & TOPO SURVEY BOUNDARY SURVEY ❑ = FORM BOARD SURVEY ❑ = AS -BUILT SURVEY 0 - ELEV. ARE ASSUMED ❑ =ELEV. ARE N.G.V.D., 1929 DATA LEGEND: D = DEED C =CAL LATED X = EXISTING GRADE PRO. = PRORATION DISTANCE M = MEASURED DISTANCE P - PLAT DISTANCE P.C.P. = PERMANENT CONTROL POINT P.R.M. -PERMANENT REFERENCE MONUMENT ELEV. = ELEVATIONS R/R - RAILROAD CONC. = CONCRETE MON. = MONUMENT C/L = CENTERLINE FND. = FOUND BLVD. = BOULEVARD ST. = STREET AVE. = AVENUE DR. = DRIVE RD. = ROAD LA. = LANE CIR. = CIRCLE ,aN.G.V.D. = NATIONAL GEODETIC VERTICAL DATUM SQ. = SQUARE FT. = FEET F.F. = FINISHED FLOOR # = NUMBER N = NORTH S = SOUTH E = EAST W = WEST " = DEGREES = MINUTES OR FEET " = SECONDS OR INCHES RW = RIGHT OF WAY RAD. = RADIAL ASP. = ASPHALT P.C.'- POINT OF CURVE P.R.C. = POINT OF REVERSE CURVE P.T. =POINT OF TANGENT P.P. = POWERPOLE N&D = NAIL & DISK C.M.P = CORRUGATED METAL PIPE PG = PAGE DB = DEED BOOK PB = PLAT BOOK BLK = BLOCK CH = CHORD CB = CHORD BEARING BEARINGS HEREON ARE REFERRED TO,AN ASSUMED VALUE OF N 700 30' 00" E FOR THE SOUTH RAN LINE OF COMMON USE I , SAID BEARING IS IDENTICAL WITH THE PLAT OF RECORD. THE SURVEY OF THE PROPERTY SHOWN HEREON IS IN NOTES: LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR ACCORDANCE WITH THE DESCRIPTION FURNISHED BY EASEMENTS AND/OR RIGHTS -OF -WAY OF RECORD. DENNIS WITHEROW NO SEARCH OF THE PUBLIC RECORDS HAS BEEN MADE BY THIS OFFICE FOR ACCURACY OR OMISSIONS. I HEREBY CERTIFY THAT THIS SURVEY MEETS MINIMUM TECHNICAL STANDARDS AS SET FORTH BY THE FLORIDA BOARD OF PROFESSIONAL LAND SURVEYORS IN CHAPTER 21HH-6 FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION 472.027. FLORIDA STATUTES. REPRODUCTION IN ANY FORM IS PROHIBITED. REBARS & CAPS ON ALL CORNERS UNLESS OTHERWISE NOTED. LB4602 #5 REBARS. THIS SURVEY SUBJECT TO EASEMENTS & ALL OTHER MATTERS OF RECORD AS RECORDED, WHETHER SHOWN ON SURVEY OR NOT. I HEREBY CERTIFY THAT THE SURVEY SHOWN HEREON IS A TRUE AND CORRECT SUR MADE UNDER MY SUPERVISION AND DIRECTION, AND THAT SAID SURVEY IS ACCURATE TO THE BEST OF MY KNOWLEDGE AND BELIEF, THAT THERE ARE NO APPARENTABOVE GROUND ENCROACHMENTS UNLESS SHOWN OR NOTED. THIS SURVEY NOT TO BE USED FOR F CE INSTALLATION, SPRINKLER SYSTEMS, SHRUBS OR ANY OTHER UTILITIES WITHOUT REVERIFICATION OF PROPERTY CORNERS. THIS SURVEY NOT VALID UNLESS SEALED GEORGE M. AYLOR, JR. WITH AN EMBOSSED SURVEYORS SEAL. REGISTERED LAND SURVEYOR, FLORIDA CERTIFICATE #4015 SCALE V° - 20' AYL®RINC.CHECKED BY JOBNO. 7713-95 , DRAWN BY GMA FIELD BK. N0. LAND SURVEYING 4933 S.E. PINE KNOLL WAY, STUART, FLORIDA 34997 — MAILING ADDRESS REFERENCES FIELD WORK DATE 1-25-95 2201 S.E. INDIAN STREET, UNIT H-19, STUART, FLORIDA 34997 —(OFFICE) FLOOD ZONE "AE" DATE 2-14-95 TELEPHONE (407) 287-0664 DFVTFFn-i-ID-Q5-CHANGE S E OF HOUSE