PROJECT INFORMATION 2
+wrightsoft Right -Suite® Universal 2017 Short Form UNIT ONE SCANNED BY St. Lucie County Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI Job: Date: Jun 14, 2017 By: Htg Clg Htg Clg Outside db (OF) 42 90 Inside db (OF) 70 75 Outside RH N - 60 Inside RH M - 50 Outside wb (OF) - 78 Inside wb (OF) - 63 Daily range (OF) - 15 Design TD (OF) 28 15 Moisture dill (gr/Ib) - 61 Heating Equipment Cooling Equipment Make Make Goodman Mfg. Model Model GSX140601 K Type Elec strip Type Split AC Efficiency 100 EFF COP / EER / SEER 14.0 Heating Input 9.0 kW Sensible Cooling 42.8 MBtuh Heating Output 30.8 MBtuh Latent Cooling 14.3 MBtuh Humidifier 3.6 gpd Total Cooling 57.0 MBtuh Leaving Air Temp 120.0 OF Leaving Air Temp 55.0 OF Actual Heating Fan 560 cfm Actual Cooling Fan 1775 cfm Equipment Location UNIT ONE System Type PEAKCV Fan Motor Heat Type PACKAGE Fan & Motor Combined Efficiency 0 % Static Pressure Across Fan 0 in H2O NAME I Area ft2 I Heat Loss I Sensible Gain I Latent Gain I Htg drn I Clg cfm I Time OFFICE 1 273 10198 14852 2255 197 559 Jul 1700 LDT OFFICE 3 108 2950 4841 974 53 169 Jul 1700 LDT OFFICE 4 108 2235 4532 974 37 157 Jul 1700 LDT OFFICE 5 296 6200 9336 1958 109 323 Jul 1700 LDT OFFICE 2 247 8332 13173 2119 158 513 Jul 1700 LDT MECH 1 80 879 1677 827 7 54 Jul 1700 LDT UNIT ONE 1112 30794 1 48409 1 9107 560 1 1775 Jul 1700 LDT wri htsoft- 2017Jun-1418-16-58 9 PightSuite® thwersal 201717.0.17 MU06570 Page 1 ... r%ManualAStates Anomay OKce2nd Floor.mp CeIc=CLTD Front Doorfaces: E 4wrightsoft Right~Suite®Universal 2017Short Form Date: Jun 14,20,7 UNIT THREE By: Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI Htg Clg Htg Clg Outside db (OF) 42 90 Inside db (OF) 70 75 Outside RH N - 60 Inside RH N - 50 Outsidewb (OF) - 78 Insidewb (OF) - 63 Daily range (OF) - 15 Design TD (OF) 28 15 Moisture diff. (gr/Ib) - 61 Heating Equipment Cooling Equipment Make Make Goodman Mfg. Model Model GSX140601 K Type Else strip Type Split AC Efficiency 100 EFF COP / EER / SEER 14.0 Heating Input 8.2 kW Sensible Cooling 42.8 MBtuh Heating Output 28.1 MBtuh Latent Cooling 14.3 MBtuh Humidifier 4.2 gpd Total Cooling 57.0 MBtuh Leaving Air Temp 120.0 OF Leaving Air Temp 55.0 OF Actual Heating Fan 512 cfm Actual Cooling Fan 1775 cfm Equipment Location UNIT THREE System Type PEAKCV Fan Motor Heat Type PACKAGE Fan & Motor Combined Efficiency 0 % Static Pressure Across Fan 0 in H2O NAME I Area ft2 I Heat Loss I Sensible Gain I Latent Gain I Htg cfm Clg cfm I Time OFFICE 7 234 7696 12097 2051 152 525 Jul 1700 LOT MEDIA RM 144 3634 4807 1162 68 185 Jul 1700 LOT OFFICE 9 325 6705 10806 2109 124 421 Jul 1700 LDT OFFICE 8 192 4474 6284 1413 83 246 Jul 1700 LDT MECH 3 108 1111 2145 974 9 78 Jul 1700 LDT H3 102 1062 2045 943 9 74 Jul 1700 LDT lobby 2 90 3457 6172 1298 66 245 Jul 1700 LDT UNIT THREE 1195 1 28139 I 44356 9950 1 512 11 1775 Jul 1700 LDT wrightsoft, Right -Suite® lhlversal 201717.0.17 MU06570 2017Jun447e:Page age2 2 ... Mlanual JlSWtes Attamey Once 2nd Floor.tup CeIc=DLTD FmM Daarracas: E Right -Suite® Universal 2017 Short Form Job: wrightSOft' UNIT TWO Date: Jon 14, 2017 Project• • For: State Attorney Office 2sec Street, Fort Pierce, FI Htg Clg Htg Clg Outside db (OF) 42 90 Inside db (OF) 70 75 Outside RH N - 60 Inside RH N - 50 Outside wb (OF) - 78 Inside wb (OF) - 63 Daily range (OF) - 15 Design TD (OF) 28 15 Moisture dill (gr/lb) - 61 Heating Equipment Cooling Equipment Make Make Goodman Mfg. Model Model GSX140601 K Type Elec strip Type Split AC Efficiency 100 EFF COP / EER / SEER 14.5 Heating Input 5.0 kW Sensible Cooling 42.8 MBtuh Heating Output 17.2 MBtuh Latent Cooling 14.3 MBtuh Humidifier 5.7 gpd Total Cooling 57.0 MBtuh Leaving Air Temp 120.0 "F Leaving Air Temp 55.0 OF Actual Heating Fan 313 cfm Actual Cooling Fan 1775 cfm Equipment Location UNIT TWO System Type PEAKCV Fan Motor Heat Type PACKAGE Fan & Motor Combined Efficiency 0 % Static Pressure Across Fan 0 in H2O NAME I Area ft2 I Heat Loss Sensible Gain I Latent Gain I Htg cfm I Clg cfm Time MECH 2 108 2235 4532 974 31 189 Jul 1700 LOT KITCHEN 120 3778 6823 1454 57 289 Jul 1700 LDT LOBBY 80 3323 5971 1245 51 254 Jul 1700 LDT RECEPTION 504 4400 8775 3046 35 350 Jul 1700 LDT BATH 1 30 464 840 566 2 31 Jul 1700 LDT BATH 2 30 464 840 566 2 31 Jul 1700 LDT STORAGE 1 72 1170 1140 786 12 68 Jul 1700 LDT OFFICE 6 234 7696 12097 2051 122 563 Jul 1700 LDT UNIT TWO I 1178 I 23529 I 41617 I 10688 I 313 I 1775 I Jul 1700 LDT 2017-Jun-14 18:16:58 Wrightson' WghtSuite® 11 ivemal 201711.0.17 FSW6570 Page ...Manual Mtales Allomey Office 2nd Floor.rup Calo=CLTD Fmnt Doorfaces: E RightSuite® Universal 2017 Load Summary Job: wrightsofr UNIT ONE Date: Jun 14, 2017 By: Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI Zone.�_.UNIT ONE... _ ,-____-_..--..- -- -- -- - --- ---_ _._ ._ _-COOLING.LOAD -..-_--_..--__---- __---_�--i 1. DESIGN CONDITIONS at Jul 1700 LDT Peak load at Jul 1600 LOT Inside: 75 OF Outside: 90 OF TD: 15 OF RH: 60 % MoistDiff: 61.5 gr/lb Mult: 1.0 Ins.wb 63 OF Sensible Latent 2. SOLAR RADIATION THROUGH GLASS 16490 - 3. TRANSMISSION GAINS Sensible 12994 - Walls: 1554 _ _ Glass: 8596 _ Doors: 0 _ Partitions: 0 _ Floors: 0 - _ Ceilings: 2844 _ _ 4. INTERNAL HEAT GAIN Sensible Latent 15118 2683 Occupants: 3353 2683 - - Lights: 9109 - Motors: 0 - Appliances: 2656 0 - - 5. INFILTRATION: Outside air cfm: 20 320 835 6. SUBTOTAL: Space load Sensible Latent 44922 3518 Envelope 44922 3518 - - Less external 0 - Redistribution 0 0 - 7. SUPPLY DUCT 1348 _ 8. SUBTOTAL:. Space load + supply duct 46270 - Actual cfm: 1775 at supply TD: 20 9. VENTILATION: Make-up air cfm: 134 2139 5589 10. RETURN AIR LOAD: Lighting + plenum (net) 0 - 11. RETURN DUCT 0 _ 12. TOTAL LOADS ON EQUIPMENT 48409 9107 _- __-- _-- _----.-- _ ---_--- ., --- HEATING LOAD _-- _--- 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 21845 Walls: 2727 - Glass: 16599 - Doors: 0 - Partitions: 0 - Floors: 276 - Ceilings: 2243 - 15. INFILTRATION: Outside air cfm: 90 2771 16. SUBTOTAL: Spaceload 24616 Envelope 24616 - Less external 0 - Less transfer 0 - Redist6bution 0 - 17. SUPPLY DUCT: 738 18. VENTILATION: Make-up air cfm: 134 4117 — - - - - 19. HUMIDIFICATION 1323 Piping 0 20. RETURN DUCT. 0 21. TOTAL HEATING LOAD ON EQUIPMENT 30794 wrtghItsoft 2017-Jun-1418:16:58 RighlSuite® lhivema1201717.0.17 PSU06570 Page 1 ...rWanual Mtates Attorney Office 2nd Floocrup Calc=CLTD Fmnt Door feces: E RightSuite® Universal 2017 Load Summary Job: wrrightsoft- UNIT THREE Date: Jun 14, 2017 By: Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI Zone:_ __UNIT_THREE_. _ — COOLING.LOAD_ 1. DESIGN CONDITIONS at Jul 1700 LDT Inside: 75 OF Outside: 90 OF RK 60 % MoistDiff: 61.5 gr/lb 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls: 2420 Glass: 6276 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 3057 4. INTERNAL HEAT GAIN Sensible Occupants: 3742 Lights: 9788 Motors: 0 Appliances: 2854 5. INFILTRATION: Outside air cfm: 6. SUBTOTAL: Space load Sensible Envelope 40789 Less external 0 Redistribution 0 7. SUPPLY DUCT 8. SUBTOTAL: Space load + supply duct Actual cfm: 1775 at supply TD: 9. VENTILATION: Make-up air cfm: 10. RETURN AIR LOAD: Lighting + plenum (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT Peak load at Jul 1700 LDT TD: 15 OF Mult: 1.0 Ins.wb 63 OF Sensible Latent 12332 11753 Latent 16384 2993 2993 - - 0 20 320 835 Latent 40789 3829 3829 - - 0 1224 42013 20 - - 147 2343 6121 0 0 44356 9950 _..HEATING -LOAD-_-_ 13. DESIGN CONDITIONS Mult: Inside: 70 OF Outside: 42 OF TD: 14. TRANSMISSION LOSSES Walls: 3710 Glass: 12119 Doors: 0 Partitions: 0 Floors: 296 Ceilings: 2411 15. INFILTRATION: Outside air cfm: 16. SUBTOTAL: Space load Envelope 21422 Less external 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT: 18. VENTILATION: Make-up air cfm: 19. _ HUMIDIFICATION Piping 20. RETURN DUCT 21. TOTAL HEATING LOAD ON EQUIPMENT 94 147 1.0 28 OF 18536 2886 21422 643 4509 1565 0 0 28139 wrighttsoft- 20174un-14 18:16:58 RightSuite® thivereal 201717.0.17 FSU06570 Page 2 ...rWanual AStates Attomey Office 2nd Floor.rup Calc=CLTD Front Doorfaces: E RightSuite® Universal 2017 Load Summary Job: wrightsoft• UNIT TWO Date: Jun 14, 2017 By: Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI .COOLING LOAD.. 1. DESIGN CONDITIONS at Jul 1700 LDT Inside: 75 OF Outside: 90 OF RH: 60 % MoistDiff. 61.5 gr/lb 2. SOLAR RADIATION THROUGH GLASS 3. TRANSMISSION GAINS Sensible Walls: 838 Glass: 4540 Doors: 0 Partitions: 0 Floors: 0 Ceilings: 3013 4. INTERNAL HEAT GAIN Sensible Occupants: 3963 Lights: 9649 Motors: 0 Appliances: 2814 5. INFILTRATION: Outside air cfm: 6. SUBTOTAL: Space load Sensible Envelope 38077 Less external 0 Redistribution 0 7. SUPPLY DUCT 8. SUBTOTAL: Space load + supply duct Actual cfm: 1775 at supply TD: 9. VENTILATION: Make-up air cfm: 10. RETURNAIRLOAD: Lighting + plenum (net) 11. RETURN DUCT 12. TOTAL LOADS ON EQUIPMENT Peak load at Jul 1700 LDT TD: 15 OF Mult: 1.0 Ins.wb 63 OF Sensible Latent 12780 8391 Latent 3171 0 30 Latent 4424 0 20 150 -- — - -- -- - HEATING_LOAD — —'-- 16426 480 38077 1142 39219 2398 0 0 41617 13. DESIGN CONDITIONS Mult: 1.0 Inside: 70 OF Outside: 42 OF TD: 28 OF 14. TRANSMISSION LOSSES 12801 Walls: 1366 - Glass: 8767 - Doors: 0 - Partitions: 0 - Floors: 292 - Ceilings: 2376 - 15. INFILTRATION: Outside air cfm: 113 3478 16. SUBTOTAL: Space load 16278 Envelope 16278 - Less external 0 - Less transfer 0 - Redistribution 0 - 17. SUPPLY DUCT: 488 18. VENTILATION: Make-up air cfm: 150 4614 19. HUMIDIFICATION- - - 2148 Piping 0 20. RETURN DUCT 0 21. TOTAL HEATING LOAD ON EQUIPMENT 23529 4�11- wrightsoft- kghtSuite® thiversal201717.0.17 fSU06570 ...rlManual A\States Attomey Offra2nd Floor.mp Calc=CLTD Front Doorfaces: E 3171 1253 4424 6264 10688 2017Jun-14 18:16:58 Page 3 FIR INTAKE Ut Ore.Ide FRESHAIRE 134 Cm. Un0 Two aeside FRESPoURE 150 CFM UrJt Three onside Frg Wri, 147 CM Each sntemw reed a5- fi Maw (make at59A pmsswe Job M Performed for: State Attorney Office 2see Street Fort Pierce, FI Scale: 1 : 152 Page 1 RightSuite® Universal 2017 17.0.17 RSU06570 2017-Jun-14 18:17:59 ...es AttomeyOffim 2nd Floor.rup +�- wrightsoft Duct System Summary UNIT ONE Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 560 cfm Job: Date: Jun 14, 2017 By: Cooling 0.10 in H2O 0 in H2O 0.10 in H2O 0.043 / 0.057 in H2O 0.025 in/100ft 1775 cfm 403 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk MECH1 C 1477 7 54 0.025 4.0 Ox0 VIFx 10.0 160.0 st7 OFFICE 1-B c 7622 99 279 0.025 9.0 Ox 0 VIFx 14.0 160.0 st3 OFFICE I-C c 7622 99 279 0.028 9.0 Ox0 VIFx 15.9 140.0 st3 OFFICE2-A c 7000 79 257 0.025 9.0 OXO VIFx 22.0 150.0 st9 OFFICE 2-13 c 7000 79 257 0.025 9.0 Ox0 VIFx 30.3 140.0 st9 OFFICE 3-A C 4600 53 169 0.026 7.0 OXO VIFx 24.7 140.0 st8 OFFICE C 4290 37 157 0.031 7.0 Ox0 VIFx 20.8 120.0 sib OFFICE C 4407 55 162 0.026 7.0 Ox0 VIFx 16.0 150.0 st7 OFFICE5-a C 4407 1 551 162 1 0.025 7.0 OxO VIFx 8.0 165.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st8 Peak AVF 89 326 0.026 597 10.0 0 x 0 RectFbg st7 st7 Peak AVF 151 542 0.025 690 12.0 0 x 0 RectFbg st2 st2 Peak AVF 205 703 0.025 895 12.0 0 x 0 RectFbg st3 Peak AVF 355 1072 0.025 1003 14.0 0 x 0 RectFbg st9 Peak AVF 158 513 0.025 653 12.0 0 x 0 RectFbg st3 OuldrItalic values have been manually ovenfdden Wrl ht50ft' 2017Jun-1418.18:58 9 Right-SuiteQt Universal 201717.0.17 fSU08570 ...AManual AStates Attorney Once 2nd Floor.rup Calc=CLTD Front Door faces: E Page 1 0 L a 9 m ��Quu w 0) m 3 CD 0000o m� x x x x x 0000.o - n _ 3 � (O Ut W>(P V W V m m �n vt»w(n 3� (O (O V J W NN» m N N A A m �n how who �NIV O(O 0 00000 Rly O O O O O O V wD VNi((n0 N O mo 3 w m N -�mN W ^, O N J V O N o OOOo pp O pp O 0 _ X X X x X = X G 0 0 0 O o W (D O 0 O _ GGGGG g0 x Tx1 x1x X X x x N C J x -�- wrightsuftDuct System Summary UNIT THREE Project Information For: State Attorney Office 2sec Street, Fort Pierce, A External static pressure Pressurelosses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0 in H2O 0 in H2O 0 in H2O 0.000 / 0.000 in H2O 0 in/100ft 512 dim Job: Date: Jun 14, 2017 By: Cooling 0.10 in H2O 0 in H2O 0.10 in H2O 0.053 / 0.047 in H2O 0.023 in/100ft 1775 cfm 438 ft Supply Branch Detail Table Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FIR Diann (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk H3 c 1813 9 74 0.034 5.0 Ox0 VIFx 8.0 150.0 st4 MECH 3 c 1904 9 78 0.034 5.0 Ox 0 VIFx 7.0 150.0 st4 MEDIA RM C 4512 68 185 0.023 7.0 Ox0 VIFx 24.0 210.0 st11 OFFICE 7-9 c 6393 76 263 0.027 9.0 Ox0 VIFx 20.4 175.0 st10 OFFICE 7-C C 6393 76 263 0.027 9.0 Ox0 VIFx 13.9 185.0 st10 OFFICE C 2994 42 123 0.028 6.0 Ox0 VIFx 15.5 175.0 st10 OFFICE 8-A. C 2994 42 123 0.023 6.0 Ox0 VIFx 22.2 210.0 st11 OFFICE C 5121 62 210 0.026 8.0 Ox0 VIFx 20.1 185.0 st4 OFFICE 9-13 C 5121 62 210 0.024 8.0 Ox0 VIFx 27.4 195.0 st4 lobby 2-A C 5957 66 245 0.026 9.0 Ox0 VIFx 21.9 185.0 st4 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FIR (fpm) (in) (in) Material Trunk st4 Peak AVF 208 818 0.024 765 14.0 0 x 0 ReCtFbg st10 Peak AVF 304 957 0.023 895 14.0 0 x 0 RectFbg sty st5 Peak AVF 304 957 0,023 895 14.0 0 x 0 RectFbg st11 Peak AVF 110 308 0.023 565 10.0 0 x 0 RectFbg st10 6oldritalic values have been manually oveTnCtlen 20174un-1418:16:58 wfi 1ght50ft' Rght-SaltaO Universal 201717.0.17 MU06570 Page 3 ... AManual J4States Aaomey OFim 2nd Fimr.mp Cato = CLTD From Doorfaces: E 0 aeed BS:9L:SL bL•unl`LLOZ 3:saael+oo0 iuold OLIO=oleo dw'loaldPuyeow0,(awowsopISVlenueM- OLS90nStl LL'0'LL LLOZ lewamn *9ingl46.r8 .UoS,461,M + uappluaeo,fllenuaw uaaq aaeq sonlsa ogeJyploe Imms 0 x 0 0"86 OSL £ZO'0 8L£L 8Zb 3AVWOd by Nunil leualepq fond (ul) M x H (ul) weld (wdl) Dolan a� u61saO (w;0) 610 (wlo) 6lH ad6l �IunLl aweN a!gel !le;a4 Nunal uan;ab 4J lW4S 0 x0 O*G 699 9b0'0 O'lU 9Z9 M Ox0 Llgj 4u IMS 0 x0 01 1769 bZ0'0 O'E6L 98L 89 Ox0 ZLgj 43i IMS 0 x0 0'6 L99 LZO'0 O'9LL 9bZ £8 Ox0 ELgj Mi iW4S 0 x0 O'OL LLL £ZO'O O'40Z M, 4ZL Ox0 hlgL IMS 0 x0 O'OL 6ZL 7LO'O 0'£9 L6£ 48 Ox0 Blgl Aural Real (u1) 6u1uad0 (ul) (u1) (wdl) 213 W) N40) (w;o) (LID azlS aweN ;on(] lsl0flPnlS M x H we14 0018n u61sa0 131 610 6lH 911PJ a!gel !!e;ad yauea8 uanjaa wrightsoft• Duct System Summary UNIT TWO Project Infibirmation For: State Attorney Office 2sec Street, Fort Pierce, FI Job: Date: Jun 14, 2017 By: Heating Cooling External static pressure 0 in H2O 0.10 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0.10 in H2O Supply / return available pressure 0.000 / 0.000 in H2O 0.075 / 0.025 in H2O Lowest friction rate 0 in/100ft 0.021 in/100ft Actual air flow 313 cfm 1775 cfm Total effective length (TEL) 480 ft Supply Branch Detail Table Name Design (Biuh) Htg (cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 1 c 715 2 31 0.041 4.0 Ox 0 VIFx 12.0 170.0 st1 13ATH2 c 715 2 31 0.029 4.0 Ox0 VIFx 21.3 235.0 st1 KITCHEN c 6564 57 289 0.032 9.0 Ox0 VIFx 16.1 220.0 st1 LOBBY-B c 5772 51 254 0.025 9.0 Ox0 VIFx 29.1 265.0 st6 MECH 2-A c 4290 31 189 0.042 7.0 Ox 0 VIFx 11.1 165.0 st1 OFFICE 6-13 c 6393 61 281 0.021 9.0 Ox0 VIFx 49.0 310.0 st6 OFFICE 6-C c 6393 61 281 0.021 9.0 Ox0 VIFx 45.3 310.0 st6 RECEPTION c 2648 12 117 0.023 6.0 Ox0 VIFx 45.0 275.0 st6 RECEPTION -A c 2648 12 117 0.024 6.0 OXO VIFX 38.0 275.0 st6 RECE"ION-B c 2648 12 117 0.032 6.0 OX0 VIFX 16.0 220.0 st1 STORAGEI c 1553 12 68 0.074 5.0 ox0 VIFx 6.1 95.0 Supply Trunk Detail Table Trunk Htg I Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st1 Peak AVF 301 1707 0.021 966 1&0 0 x 0 ShtMetl st6 PeakAVF 197 1050 0.021 752 16.0 0 x 0 ShtMetl st1 Bold italic values have been manually ovenitlGen 20174un-1418:16:58 wright50ft' Right -Suite® Universal 201717.0.17 FWD6570 Page 5 ... rXManuai JlStates Allomey Office2nEFloor.mp Calc=CLTD Front DcorfacesE Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening (in) Matl Trunk rb10 Ox0 122 563 107.0 0.024 716 12.0 Ox 0 VIFx rt5 rb9 Ox0 87 604 116.0 0.022 655 13.0 Ox 0 VIFx rt5 rb4 Ox0 104 609 121.0 0.021 661 13.0 Ox 0 VIFx rt1 Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk rt1 Peak AVF 313 1775 0.021 1004 18.0 0 x 0 RectFbg rt5 Peak AVF 209 1166 0.022 1091 14.0 0 x 0 RectFbg rt1 Bold/ifalic values have been manually overridden Wfl9t1Y50ft' RightSuile® lhiversa1201717.0.17 fSU06570 2017Jun-1418:16.58Page 6 ...rWanual AlStates Attomey Offim2nd Floor.mp Calc=CLTD Front Doorfaces: E RightSuite® Universal 2017 Load Calculation Job: wrightsoft BATH 1 Date: Jun 14, 2or By: Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI Zone LWH: 5.0 x 6.0 x 9.0 1. DESIGN CONDITIONS - COOLING ( Jul 1700 LDT ) Dry Bib RH Moisture Range Wet Bib Outdoor Conditions —> 90 60 15 78 Indoor Conditions —> 75 50 63 TOD Correction Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Area —> 0 15 ( Let = Tilt ShdF IntShd Mult = 1.0 ] — 3. TRANSMISSION GAINS ®#- Type Orien GrArea .NtArea Uval Grp CLTD Jr Shad Cir Sens FLOR-01 - 30 30 0.009 0 - 0 CEIL-01 - 30 30 0.072 RC-7 35.5 - d 77 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft'/prsn # people Btuh/prsn Btuh/prsn Office 150 1 1 250 200 300 240 8to6-E 0 0 0 0 0 0 0 LIGHTS Lamp/blst+fixture W/fta W Total Factor Space Sens Schedule W fract Fluor MB + Rao trof 2.00 0 60 1.20 1.0 246 8to6-E Fluor MB + Rec trot 0 0 0 1.20 1.0 0 Fluor MB + Rao trof 0 0 0 1.20 1.0 0 Fluor MB + Rao trof 0 0 0 1.20 1.0 0 20174un-1418.50:02 W ightsoft' PightSuile® Universal 201717.0.17 RSU06570 Page 1 ... rWanual A\SWes AOomey OKoe2nd Floor.mp Calc=CLTD Front Doorfaoes: E APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 72 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 0 cfm x db Temp Diff 14.6 x 1.10 0 —> x Moist. Diff 61.5 x 0.68 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 694 566 Envelope 694 240 Less external coaling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 21 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6 ) & Drawthru Fan = 715 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 715) / ( 1.10 x 20.0 ) = 33 Actual Cooling Fan = 31 9. VENTILATION CA 8 cfm —> x db Temp Diff 14.6 x 1.10 125 —� x Moist. Diff 61.5 x 0.68 326 10. RETURN AIR PLENUM Lights Total power(W) 60 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 840 566 +wr1ghtsof * Right-SUKeOlhiversal20171Zge 0.17MU06570 2077JuM47 Pat Page 2 ...MAanuel JlStates Attorney Office 2ntl Floor.rup Cale=CLTD Frorrt Door faces: E SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TO = (Inside DB - Outside DB) _ ( 70 - 42) = 28 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss FLOR-01 30 30 0.009 28.0 7 CEIL-01 30 30 0.072 28.0 61 15. INFILTRATION Loss 1 cfm x db Temp Diff 28.0 x 1.10 42 16. SUBTOTAL HEATING LOAD FOR SPACE 109 Envelope 109 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 3 Less transfer 0 Redistribution 0 18. VENTILATION OA 8 cfm x db Temp Diff 28.0 x 1.10 240 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 9 cfm x 0.20 g/100cfm/d = 0.3 gpd 11 m Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 464 Loss factor x Line 16 Loss Wii htsofC 2017Jun-1418:50:02 9 Right-SuHe® Ihiversal 201717.0.17 MU06570 Page 3 ... rUanual JlStates AHorney Ofiim2nd Floor.rup Cale=CLTD Front Doorfams: E RightSuite® Universal 2017 Load Calculation Job: WrightsoftBArH 2 Date: Jun 14, 2017 By: Project Information For. State Attorney Office 2sec Street, Fort Pierce, FI Zone__ BATH 2 -' - - -- - - - _ - - ---- -- - - - --- - ---- - ---,1 LWH: 5.0 x 6.0 x 9.0 1. DESIGN CONDITIONS -COOLING Outdoor Conditions —> Indoor Conditions —> TOD Correction —> Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Area Tilt ( Jul 1700 LDT ) Dry Bib RH Moisture Range 90 60 15 75 50 0 15 61.5 ( Let = 27.45 oN Const Wt = M ShdF IntShd SCMult SC Sens/A Wet Bib 78 63 Mutt = 1.0 ] — Sens 3. TRANSMISSION GAINS Type Orion GrArea NtArea Uval Grp CLTD Shad Clr Sens FLOR-01 - 30 30 0.009 0 - 0 CEIL-01 - 30 30 0.072 RC-7 35.5 - d 77 4. INTERNAL HEAT GAIN PEOPLE Activity Total Sensible Latent Schedule ft2lprsn # people Btuh/prsn Btuh/prsn Office 150 1 1 250 200 8to6-E 0 0 0 0 0 LIGHTS Lamp/blst+fixture W/ft2 W Total Factor Space Schedule W fract Fluor MB + Rec trot 2.00 0 60 1.20 1.0 8to6-E Fluor MB + Rec trof 0 0 0 1.20 1.0 Fluor MB + Rec trof 0 0 0 1.20 1.0 Fluor MB + Rec trof 0 0 0 1.20 1.0 + wrightsoft• PighlS.R.8 Wiwrsal 201717.0.17 RSU06570 ...Wanual AStates Attomey Office 2nd Floor.rup Calcm CLTD Front Door faces: E Sens Latent 300 0 Sens 246 0 0 0 240 0 2017-Jun-1418:50+02 Page 1 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ftz W 8to6-E 0.70 0 1.00 3.412 0 72 0 #Ift2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # A 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 S. INFILTRATION Sens Latent 0 cfm x db Temp Diff 14.6 x 1.10 0 —> x Moist. Diff 61.5 x 0.68 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 694 566 Envelope 694 240 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 21 S. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 715 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 715) / ( 1.10 x 20.0 ) = 33 Actual Cooling Fan = 31 9. VENTILATION OA 8 cfm > x db Temp Diff 14.6 x 1.10 125 —> x Moist. Diff 61.5 x 0.68 326 10. RETURN AIR PLENUM Lights Total power (W) 60 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 840 566 wrightsoft' Right -Suite® Lhiverse1201717.0.17 MU06570 2017-Jun-1476:Raeege2 z ...rlManual JlStates Altomey Office2nd Floocrup Calc=DLTD Front Door (aces: E SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss FLOR-01 30 30 0.009 CEIL-01 30 30 0.072 28.0 28.0 7 61 15. INFILTRATION Loss 1 cfm x db Temp Diff 28.0 x 1.10 42 16. SUBTOTAL HEATING LOAD FOR SPACE 109 Envelope 109 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 3 Less transfer 0 Redistribution 0 18. VENTILATION CA 8 cfm x db Temp Diff 28.0 x 1.10 240 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 9 cfm x 0.20 g1100cfm1d = 0.3 gpd 1111) Piping 0 21. TOTAL HEATING LOAD ON EQUIPMENT (Btuh) 464 Loss factor x Line 16 Loss 20174un-1418:50:02 wrightsoft' Right -Suite® lhiversal 201717.0.17 RSU06570 Page 3 ...iAManual JIStates Attomey ORce2nd Floor.mp Calc=CLTD Front Doorfaces: E RightSuite® Universal 2017 Load Calculation Job: wrightsofts H3 Date: Jun 14, 2017 By: Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI Zone: H3 LWH: 102.0 x 1.0 x 9.0 -- -- —� — — — ^ — 1. DESIGN CONDITIONS - COOLING ( Jul 1700 LDT ) Dry Blb RH Moisture Range Wet Blb Outdoor Conditions —> 90 60 15 78 Indoor Conditions —> 75 50 63 TOD Correction —> 0 Difference 15 61.5 Mult = 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Let = 27.45 °N Const Wt = M) Type Orien Area Tilt ShdF IntShd SCMult Sc Sens/A Sens 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens FLOR-01 - 102 102 0.009 0 - 0 CEIL-01 - 102 102 0.072 RC-7 35.5 - d 261 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 1 2 250 200 420 336 8to6-E 0 0 0 0 0 0 0 LIGHTS Lamp/blst+fixture W/ft2 W Total Factor Space Sens Schedule W fract Fluor MB + Rec trof 2.00 0 204 1.20 1.0 836 8to6-E Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 wrightsoft� RighlSuite® Lhiversal201717.0.17 2017Jun-1418:50:02 FSU06570 Page 1 ... rWanual J%States Attomey Ofrice2nd Floor.mp celc=CLTD Fmnt Doorfacest E APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 244 0 #/fta # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 0 cfm —> x db Temp Diff 14.6 x 1.10 0 �> x Moist. Diff 61.5 x 0.68 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 1760 943 Envelope 1760 336 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 53 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 1813 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 1813) / ( 1.10 x 20.0 ) = 82 Actual Cooling Fan = 74 9. VENTILATION CA 15 cfm x db Temp Diff 14.6 x 1.10 232 x Moist. Diff 61.5 x 0.68 607 10. RETURN AIR PLENUM Lights Total power (W) 204 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 2045 943 wrightsoft' Nghl-Suite®lhiversal2017l7.0.17MU06570 2017-Jun-14 18 50 02 ... rlManual J\Slales AHomey O<fice 2nC Floouup CeIc=CLTD Front Door faces: E Page 2 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 [ = ] - Mult 1.0 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss FLOR-01 102 102 0.009 28.0 25 CEIL-01 102 102 0.072 28.0 206 15. INFILTRATION Loss 5 cfm x db Temp Diff 28.0 x 1.10 141 16. SUBTOTAL HEATING LOAD FOR SPACE 372 Envelope 372 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 11 Less transfer 0 Redistribution 0 18. VENTILATION OA 15 cfm x db Temp Diff 28.0 x 1.10 447 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 19 cfm x 0.20 g/100cfm/d = 0.6 gpd 230 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 1062 Loss factor x Line 16 Loss + wri htsoR^ 2017-Jun-1418:50:02 9 Right -Suite® lhiversa1201717.0.77 fSUG6570 Page 3 ...rlManual JlStates Attorney Office 2ntl Floor.rup Cale =CLTD Front Door laces: E RightSuite@ Universal 2017 Load Calculation Job: wrightsofte KITCHEN Date: Jun 14, 2017 By: Project Information For. State Attorney Office 2sec Street, Fort Pierce, FI Zone: KITCHEN i LWH: 12.0 x 10.0 x 9.0 _- - --' - ---------_ --- -'� 1. DESIGN CONDITIONS - COOLING Outdoor Conditions Indoor Conditions TOD Correction Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Area GLAZ-01 w 20 GLAZ-02 w 25 Dry Bib —> 90 —> 75 —> 0 ( Jul 1700 LDT ) RH Moisture 60 50 Range Wet Bib 15 78 63 15 61.5 i Mult = 1.0 ] — ( Let = 27.45 ON Const Wt = M ) Tilt ShdF IntShd SCMuit Sc Sens/A Sens 90 --- n 1.00 0.63 69.7 1422 90 — n 1.00 0.63 69.7 1765 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad CIr Sens GLAZ-01 w 20 20 1.270 14.5 N - 1797 GLAZ-02 w 25 25 1.270 14.5 N - 2232 WALL-01 w 90 44 0.230 D 15.4 N m 157 FLOR-01 - 120 120 0.009 0 - 0 CEIL-01 - 120 120 0.072 RC-7 35.5 - d 307 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft'/prsn # people Btuh/prsn Btuh/prsn Office 150 1 2 250 200 450 360 8to6-E 0 0 0 0 0 0 0 wrightsofz017Jun-1418:50:02 C RightSulte® lhiversal 201717.0.17 MUD6570 Page 1 ... r%Manual RStates Attomey Of w2nd Floor.rup C21a=CLTD Front Doorfaws: E LIGHTS Lamp/blst + fixture W/ft2 W Total Factor Space Sens Schedule W fract Fluor MB + Rec trof 2.00 0 240 1.20 1.0 983 8to6-E Fluor MB + Rec trot 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 287 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 10 cfm -> x db-Temp Diff 14.6 x 1.10 160 -> x Moist. Diff 61.5 x 0.68 418 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 6373 1454 Envelope 6373 778 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 191 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 6564 (L 8 Sens ) / (Xfar x Supply TD ) = cfm Est Cooling cfm = ( 6564) / ( 1.10 x 20.0 ) = 299 Actual Cooling Fan = 289 9. VENTILATION CA 16 cfm x db Temp Diff 14.6 x 1.10 259 -> x Moist. Diff 61.5 x 0.68 677 Wr19Mtt_SOft' gightSulte® 2017Jun-141e:50:02 Universal 201717.0.17 r6U06570 Page 2 ._rWanual JlStates Aftomey Ofrim2nd Floor.rup Calc=CLTO Front Doorfaoes: E 10. RETURN AIR PLENUM Lights Total power (W) 240 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 6823 1454 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 [ Mult = 1.0 ] — 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HID Loss GLAZ-01 w 20 20 1.270 28.0 725 GLAZ-02 w 25 25 1.270 28.0 901 WALL-01 w 90 44 0.230 28.0 285 FLOR-01 120 120 0.009 28.0 30 CEIL-01 120 120 0.072 28.0 242 15. INFILTRATION Loss 25 cfm x db Temp Diff 28.0 x 1.10 782 16. SUBTOTAL HEATING LOAD FOR SPACE 2964 .Envelope 2964 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 89 Less transfer 0 Redistribution 0 18. VENTILATION OA 16 cfm x db Temp Diff 28.0 x 1.10 499 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 42 cfm x 0.48 g/100cfm/d = 0.6 gpd 226 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 3778 Loss factor x Line 16 Loss 2017Jun-14 13:50:02 wrightsoft' PoghlSuite® lhiversal201717.0.17 MU06570 Page 3 ...OManual J\Stales Attomey URca2nd Floor.mp CaIc=CLTD Front Doorfaces: E RightSuite(D Universal 2017 Load Calculation Job: wrightsoft- Date: Jun 14, 2017 LOBBY By: Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI -_Zone_-. LOBBY_.- LWH: 10.0 x 8.0 x 9.0 1. DESIGN CONDITIONS - COOLING Outdoor Conditions Indoor Conditions TOD Correction Difference Dry Bib —> 90 —> 75 —> 0 2. GLAZING SOLAR HEAT GAIN Type Orien Area Tilt GLAZ-01 w 24 90 GLAZ-02 w 20 90 ( Jul 1700 LDT ) RH Moisture Range Wet Bib 60 15 78 50 63 15 61.5 [ Mult = 1.0 ] — ( Let = 27.45 °N Const Wt = M ) ShdF IntShd SCMult SC Sens/A Sens n 1.00 0.63 69.7 1673 n 1.00 0.63 69.7 1422 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ-01 w 24 24 1.270 14.5 N - 2115 GLAZ-02 w 20 20 1.270 14.5 N - 1797 WALL-01 w 72 28 0.230 D 15.4 N m 98 FLOR-01 - 80 80 0.009 0 - 0 CEIL-01 - 80 80 0.072 RC-7 35.5 - d 205 4. INTERNAL HEAT GAIN PEOPLE Activity Total Sensible Schedule ft2/prsn # people Btuh/prsn Office 150 1 2 250 8to6-E 0 0 0 0 + wrightsoft' RightSuite® thiversel 201717.0.17 fW06570 ...rWanualAStates Attomey0frcw2nd Floor.mp Calc=CLTD Front Doorfaces: E Sens Latent Latent Btuh/prsn 200 383 307 0 0 0 2017Jun-1418:50:02 Page 1 LIGHTS Lamp/blst + fixture W/ft2 W Total Factor Space Sens Schedule W fract Fluor MB + Rec trot 2.00 0 160 1.20 1.0 655 8to6-E Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 191 0 #/ft2 # 0 0 1.00 0 0 0 0 #Ift2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 S. INFILTRATION Sens Latent 10 cfm -> x db Temp Diff 14.6 x 1.10 160 > x Moist. Diff 61.5 x 0.68 418 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 5604 1245 Envelope 5604 724 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 168 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 5772 (L 8 Sens ) 1 (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 5772) / ( 1.10 x 20.0 ) = 263 Actual Cooling Fan = 254 9. VENTILATION CA 12 cfm -> x db Temp Diff 14.6 x 1.10 199 -> x Moist. Diff 61.5 x 0.68 521 2017-Jun-1418.50.02 WflQ�1fC50fi fC' RightSuite® universal 201717.0.17 RSU06570 Paget ...Manuel AStates Aftomey Office 2nd Floor.rup Calc=CLTD Front Doorfaces: E 10. RETURN AIR PLENUM Lights Total power (W) 160 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 5971 1245 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TO = (Inside DB - Outside DB) _ ( 70 - 42) = 28 [ Mult = 1.0 ] — 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ-01 w 24 24 1.270 28.0 853 GLAZ-02 w 20 20 1.270 28.0 725 WALL-01 w 72 28 0.230 28.0 177 FLOR-01 80 80 0.009 28.0 20 CEIL-01 80 80 0.072 28.0 161 15. INFILTRATION Loss 24 cfm x db Temp Diff 28.0 x 1.10 726 16. SUBTOTAL HEATING LOAD FOR SPACE 2664 Envelope 2664 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 80 Less transfer 0 Redistribution 0 18. VENTILATION OA 12 cfm x db Temp Diff 28.0 x 1.10 384 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 36 cfm x 0.48 g/100cfm/d = 0.5 gpd 196 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 3323 Loss factor x Line 16 Loss WPC htscft- 20n,lun-1418.50:02 9 Wg�t-Suite® lhiversa1207717.0.i7 fSU06570 ...AManual AStates Attomey Office 2nd Floor.mp Cale =CLTD Fronl Door faces: E Page 3 RightSuite® Universal 2017 Load Calculation Job: wrightsofr Date: Jun 14, 2017 lobby 2 By. Project. • For: State Attorney Office 2sec Street, Fort Pierce, FI Zone: lobby 2 LWH: 10.0 x 9.0 x 9.0 1. DESIGN CONDITIONS - COOLING ( Jul 1700 LDT ) Dry Blb RH Moisture Range Wet Blb Outdoor Conditions —> 90 60 15 78 Indoor Conditions —> 75 50 63 TOD Correction —> 0 Difference 15 61.5 [ Mult = 1.0 .] — 2. GLAZING SOLAR HEAT GAIN ( Lat = 27.45 °N Const Wt = M ) Type Orien Area Tilt ShdF IntShd SCMult Sc Sens/A Sens GLAZ-01 w 24 90 — n 1.00 0.63 69.7 1673 GLAZ-02 w 20 90 -- n 1.00 0.63 69.7 1422 3. TRANSMISSION GAINS Type Orien GrArea N1Area Uval Grp CLTD Shad Clr Sens GLAZ-01 w 24 24 1.270 14.5 N - 2115 GLAZ-02 w 20 20 1.270 14.5 N - 1797 WALL-01 w 81 37 0.230 D 15A N m 130 FLOR-01 - 90 90 0.009 0 - 0 CEIL-01 - 90 90 0.072 RC-7 35.5 - d 230 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft2lprsn # people Btuh/prsn Btuh/prsn Office 150 1 2 250 200 400 320 8to6-E 0 0 0 0 0 0 0 2017Jun-1418:50:02 wrightsoft, Right-Sude® Wivemal 2017 17.0.17 MU06570 Page 1 ...rUAanualAStates Attomey ORce2nd Floor.mp Calc=CLTD Front Doorfaces: E LIGHTS Lamp/blst + fixture W/fta W Total Factor Space Sens Schedule W frail Fluor MB + Rec trof 2.00 0 180 1.20 1.0 737 8to6-E Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft' W 8to6-E 0.70 0 1.00 3.412 0 215 0 #/fta # 0 0 1.00 0 0 0 0 #/fta # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft' # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #12 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 10 cfm -> x db Temp Diff 14.6 x 1.10 160 -> x Moist. Diff 61.5 x 0.68 418 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 5784 1298 Envelope 5784 738 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 174 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 5957 (L 8 Sens ) / (Xfer x Supply TO ) = cfm Est Cooling cfm = ( 5957) / ( 1.10 x 20.0 ) = 271 Actual Cooling Fan = 245 9. VENTILATION CA 13 cfm x db Temp Diff 14.6 x 1.10 214 -> x Moist. Diff 61.5 x 0.68 560 2017-Jun-1418:50:02 W ightsoft Right -Suites universal 2017 17.0.17 FCU06570 page 2 ...rWanual JlStates Attomey Ofriice2nd Floor.rup Calc=CLTD %nt Doorfaces: E 10. RETURN AIR PLENUM Lights Total power (W) 180 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 6172 1298 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 Mult [ = 1.0 ] - 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ-01 w 24 24 1.270 28.0 853 GLAZ-02 w 20 20 1.270 28.0 725 WALL-01 w 81 37 0.230 28.0 235 FLOR-01 90 90 0.009 28.0 22 CEIL-01 90 90 0.072 28.0 182 15. INFILTRATION Loss 24 cfm x db Temp Diff 28.0 x 1.10 740 16. SUBTOTAL HEATING LOAD FOR SPACE 2758 Envelope 2758 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 83 Less transfer 0 Redistribution 0 18. VENTILATION CA 13 cfm x db Temp Diff 28.0 x 1.10 412 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 37 cfm x 0.48 g/100cfm/d = 0.6 gpd 20D Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 3457 Loss factor x Line 16 Loss wrightsoft^ RlghlSutle® 2017Jun-1418:50:02 Utiversal 201717.0.17 FZSUD6570 ...rNAanual JlStates Altomey Office2nd Flocr.rup Calc=DL7D Front Doorlaces: E Page 3 RightSuite® Universal 2017 Load Calculation Job: wrightsoW MECH 1 Data: Jun 14, 2017 By: Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI Zone:- _-MECH 1 LWH: 10.0 x 8.0 x 9.0 1. DESIGN CONDITIONS - COOLING Outdoor Conditions —> Indoor Conditions —> TOD Correction —> Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Area Tilt Dry Bib 90 75 0 15 ( Let ShdF IntShd ( Jul 1700 LDT ) RH Moisture 60 50 Range Wet Bib 15 78 63 61.5 27A5 °N Const Wt = M SCMult SC Sens/A Mult = 1.0 ] Sens 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens FLOR-01 - 80 80 0.009 0 - 0 CEIL-01 - 80 80 0.072 RC-7 35.5 - d 205 4. INTERNAL HEAT GAIN PEOPLE Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 1 2 250 200 8to6-E 0 0 0 0 0 LIGHTS Lamp/blst+fixture W/ft2 W Total Factor Space Schedule W fract Fluor MB + Rec trof 2.00 0 160 1.20 1.0 8to6-E Fluor MB + Rec trof 0 0 0 1.20 1.0 Fluor MB + Rec trof 0 0 0 1.20 1.0 Fluor MB + Rec trof 0 0 0 1.20 1.0 + vvrlghtSOft- Right -Suite® Universal 201717.0.17 FZSU06570 ...Manual AStates Attorney Office 2nd Floor.rup Calc=CLTD Front Door faces: E Sens Latent 383 0 Sens 655 0 0 0 307 0 2017Jun-14 18:50:02 Page 1 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 191 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Stuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 S. INFILTRATION Sens Latent 0 cfm —> x db Temp Diff 14.6 x 1.10 0 —> x Moist. Diff 61.5 x 0.68 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 1434 827 Envelope 1434 307 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain. 43 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 1477 (L 8 Sens ) ) (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 1477) / ( 1.10 x 20.0 ) = 67 Actual Cooling Fan = 54 9. VENTILATION OA 12 cfm > x db Temp Diff 14.6 x 1.10 199 —> x Moist. Diff 61.5 x 0.68 521 10. RETURN AIR PLENUM Lights Total power (W) 160 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 1677 827 Wil ht50tt° 2017Jun-1418:50:02 9 Right -Suite® lhiversa1201717.0.17 PSU06570 ...rWanual JlStates Attomey Offce2nd Flwr.mp Calc=CLTD Front Doorfaces: E Page 2 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 [ = ] - Mult 1.0 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss FLOR-01 80 80 0.009 28.0 20 CEIL-01 80 80 0.072 28.0 161 15. INFILTRATION Loss 4 cfm x db Temp Diff 28.0 x 1.10 111 16. SUBTOTAL HEATING LOAD FOR SPACE 292 Envelope 292 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 9 Less transfer 0 Redistribution 0 18. VENTILATION OA 12 cfm x db Temp Diff 28.0 x 1.10 384 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 16 cfm x 0.20 g/100cfm/d = 0.5 gpd 194D Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 879 Loss factor x Line 16 Loss ' 1" wrighftoft- RightSuite® Wiven:al 201717.0.17 MU06570 2017Jun-1418:50:02 Page 3 ...rlManual JlStetes Attorney ORca 2nd Floor.rup CeIc=CLTD Front Door faces: E wri htsoft° RightSuite® Universal 2017 Load Calculation Job: 9 MECH 2 Date: Jun 14, 2017 By: For: State Attorney Office 2sec Street, Fort Pierce, FI ;_.._Zone:.: MECH 2 - - -- - - - — - - - -- ---- ---- —� LWH: 12.0 x 9.0 x 9.0 1. DESIGN CONDITIONS - COOLING Outdoor Conditions Indoor Conditions TOD Correction Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Area GLAZ-01 w 24 Dry Bib —> 90 —> 75 —> 0 ( Jul 1700 LDT ) RH Moisture 60 50 Range Wet Bib 15 78 63 15 61.5 ( Lat = 27.45 °N Const Wt = M) Mult = 1.0 ] — Tilt ShdF IntShd SCMult SC Sens/A Sens 90 — n 1.00 0.63 69.7 1673 3._ TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad CIr Sens GLAZ-01 w 24 24 1.270 14.5 N - 2115 WALL-01 w 81 57 0.230 D 15.4 N m 202 FLOR-01 - 108 108 0.009 0 - 0 CEIL-01 - 108 108 0.072 RC-7 35.5 - d 276 4. INTERNAL HEAT GAIN PEOPLE Activity Schedule Office 8to6-E LIGHTS Total ft2/prsn # people 150 1 2 0 0 0 Lamp/blst+fixture W/fta W Schedule Fluor MB + Rec trof 2.00 0 8to6-E Fluor MB + Rec trof 0 0 Fluor MB + Rec trot 0 0 Fluor MB + Rec trof 0 0 + wrightsof , tight-SuiteO Unwersal 201717.0.17 RSU08570 ...Manual AStates Attomey Office 2nd Floocmp Calc=CLTD Front Dcor faces: E Sens Latent ' Sensible Latent Btuh/prsn Btuh/prsn 250 200 430 344 0 0 0 0 Total Factor Space Sens W fract 216 1.20 1.0 885 0 1.20 1.0 0 0 1.20 1.0 0 0 1.20 1.0 0 2017Jun-1418:50:02 Page 1 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 258 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 0 cfm —> x db Temp Diff 14.6 x 1.10 0 > x Moist. Diff 61.5 x 0.68 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 4165 974 Envelope 4165 344 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 125 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 4290 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 4290) / ( 1.10 x 20.0 ) = 195 Actual Cooling Fan = 189 9. VENTILATION CA 15 cfm x db Temp Diff 14.6 x 1.10 241 —> x Moist. Diff 61.5 x 0.68 630 10. RETURN AIR PLENUM Lights Total power( W) 216 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 4532 974 Wil ht50ft" 9 Right Lhiversal 201717.0.17 2017Jun4418:50:02 -Suite® MUG6570 Page 2 ...rwanual Jlstates ABomey Office 2nd Floonmp Calc=CLTD Front Door faces: E SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TO = (Inside DB - Outside DB) _ ( 70 - 42) = 28 [ = ] - Mult 1.0 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ-01 w 24 24 1.270 28.0 853 WALL-01 w 81 57 0.230 28.0 366 FLOR-01 108 108 0.009 28.0 27 CEIL-01 108 108 0.072 28.0 218 I5. INFILTRATION Loss 5 cfm x db Temp Diff 28.0 x 1.10 150 16. SUBTOTAL HEATING LOAD FOR SPACE 1614 Envelope 1614 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 48 Less transfer 0 Redistribution 0 18. VENTILATION CA 15 cfm x db Temp Diff 28.0 x 1.10 464 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 20 cfm x 0.48 g/100cfm/d = 0.3 gpd 106 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 2235 Loss factor x Line 16 Loss + wright50ft- FghtSuMQ Universal 201717.0.17 FCU06570 20174un 1418:50:02 Page 3 ...rlMenual JlStates Attorney Once 2nd Floocrup Calc=CLTD Fronl Door laces: E RightSuite® Universal 2017 Load Calculation Job: wrightsoft' MECH 3 Date: Jun 14, 2017 By: Project Information For. State Attorney Office 2sec Street, Fort Pierce, FI Zone;�MECH 3- J ---- - LWH: 12.0 x 9.0 x 9.0 1. DESIGN CONDITIONS - COOLING ( Jul 1700 LDT ) Dry Bib RH Moisture Range Wet Bib Outdoor Conditions —> 90 60 15 78 Indoor Conditions —> 75 50 63 TOD Correction —> 0 Difference 15 61.5 Mult = 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Let = 27.45 ON Const Wt = M j Type Orien Area Tilt ShdF IntShd SCMult Sc Sens/A Sens 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens FLOR-01 - 108 108 0.009 0 - 0 CEIL-01 - 108 108 0.072 RC-7 35.5 - d 276 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 1 2 250 200 430 344 8to6-E 0 0 0 0 0 0 0 LIGHTS Lamp/blst+fixture W/ft2 W Total Factor Space Sens Schedule W fract Fluor MB + Rec trof 2.00 0 216 1.20 1.0 885 8to6-E Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trot 0 0 0 1.20 1.0 0 + wrightsoft' RigMSuite® Lh"rsa1201717.0.17 FGU05570 2017Jun-1418:50:02 ... rlMenual JlStatee Atlomey OKce 2ntl Floor.rup CeIc=CLTD Front Door (aces: E Page 1 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 258 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #Ift' # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #Ift' # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 0 cfm x db Temp Diff 14.6 x 1.10 0 —> x Moist. Diff 61.5 x 0.68 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 1849 974 Envelope 1849 344 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 55 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6 ) & Drawthru Fan = 1904 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 1904) / ( 1.10 x 20.0 ) = 87 Actual Cooling Fan = 78 9. VENTILATION OA 15 cfm —> x db Temp Diff 14.6 x 1.10 241 —> x Moist. Diff 61.5 x 0.68 630 10. RETURN AIR PLENUM Lights Total power (W) 216 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 2145 974 Wil ht saft- 9 2017Jun-141e:50:02 PoghlSu0e4>l lhiversal 201717.0.77 F6U06570 ... twenual Astates Attomey OKce2nd Floor.mp Calo=CLTD Frorrt Doorfaoes: E Page 2 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TO = (Inside DB - Outside DB) _ ( 70 - 42) = 28 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss FLOR-01 108 108 0.009 28.0 27 CEIL-01 108 108 0.072 28.0 218 15. INFILTRATION Loss 5 cfm x db Temp Diff 28.0 x 1.10 150 16. SUBTOTAL HEATING LOAD FOR SPACE 394 Envelope 394 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 12 Less transfer 0 Redistribution 0 18. VENTILATION OA 15 cfm x db Temp Diff 28.0 x 1.10 464 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 20 cfm x 0.20 g1100cfm/d = 0.6 gpd 240 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 1111 Loss factor x Line 16 Loss �J}} W19 17tsOfr 2017-Jun-1418:50:02 f 9 PightSuiteg universal 201717.0.17 ISU06570 Page 3 ...Manual JlStates Attomey Ofoe 2nd Floor.rup Colo =CLTD Front Door faces: E RightSuite® Universal 2017 Load Calculation Job: wrightsofr MEDIA RM Date: Jun 14, 2017 By: Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI Zone;- _MEDIA RM__ LWH: 16.0 x 9.0 x 9.0 1. DESIGN CONDITIONS - COOLING Outdoor Conditions Indoor Conditions TOD Correction Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Area GLAZ-01 s 30 Dry Bib —> 90 —> 75 —> 0 ( Jul 1700 LDT ) RH Moisture 60 50 Range Wet Bib 15 78 63 15 61.5 [ Mult = 1.0 ] — ( Lat = 27.45 ON Const Wt = M ) Tilt ShdF IntShd SCMuit Sc Sens/A Sens 90 -- n 1.00 0.63 16.5 496 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ-01 s 30 30 1.270 14.5 N - 1048 WALL-01 e 81 81 0.230 D 27.9 N m 519 WALL-02 s 144 114 0.230 D 16.5 N m 432 FLOR-01 - 144 144 0.009 0 - 0 CEIL-01 - 144 144 0.072 RC-7 35.5 - d 368 4. INTERNAL BEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 1 2 250 200 490 392 8to6-E 0 0 0 0 0 0 0 wrightsoft' Pight-SuHe® UnNersal 2017 17.0.17 MU06670 2017Jun-1418:Page age 1 7 ... rVvlanual JlSlates Attorney OKce 2ntl Floor.rup CaIc=CLTD Frant Dcor (aces: E LIGHTS Lamp/blst + fixture W/ft2 W Total Factor Space Sens Schedule W fract Fluor MB + Rec trof 2.00 0 288 1.20 1.0 1180 8to6-E Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 344 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 0 cfm -> x db Temp Diff 14.6 x 1.10 0 �> x Moist. Diff 61.5 x 0.68 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 4381 1162 Envelope 4381 392 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 131 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 4512 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 4512) / ( 1.10 x 20.0 ) = 205 Actual Cooling Fan = 185 9. VENTILATION CA 18 cfm x db Temp Diff 14.6 x 1.10 295 x Moist. Diff 61.5 x 0.68 770 + wright5Otft• PightSu@e0 universal 201717.0.17 FEU06570 2017Jun-1418:50:02 Page 2 ...AManual JlStates Attorney OffKe 2ntl Floor.nry CeIc=DLTD Frant Door faces: E 10. RETURN AIR PLENUM Lights Total power (W) 288 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 4807 1162 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TO = (Inside DB - Outside DB) _ ( 70 - 42) = 28 Mult [ = 1.0 ] - 14. TRANSMISSION LOSSES Type Expos GrArea NetArea UvalHTD Loss GLAZ-01 s 30 30 1.270 28.0 1067 WALL-01 e 81 81 0.230 28.0 521 WALL-02 s 144 114 0.230 28.0 733 FLOR-01 - 144 144 0.009 28.0 36 CEIL-01 144 144 0.072 28.0 291 IS. INFILTRATION Loss 6 cfm x db Temp Diff 28.0 x 1.10 199 16. SUBTOTAL HEATING LOAD FOR SPACE 2846 Envelope 2846 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 85 Less transfer 0 Redistribution 0 18. VENTILATION CA 18 cfm x db Temp Diff 28.0 x 1.10 567 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 25 cfm x 0.48 g/100cfm/d = 0.4 gpd 135 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 3634 Loss factor x Line 16 Loss + wrightSOW RighlSuile® lhivemal 201717.0.17 RSU06570 2017Jun-1418:50:02 ...rVvlanual JlBtates Attorney OKce 2nd Floouup CaIc=CLTO Front Door faces: E Page 3 Right -Suite® Universal 2017 Load Calculation Job: wrightsoft OFFICE 1 Date: Jun 14, 2017 6y: For. State Attorney Office Project Information 2sec Street, Fort Pierce, FI Zone: OFFICE 1.-- LWH: 13.0 x 21.0 x 9.0 1. DESIGN CONDITIONS -COOLING Outdoor Conditions Indoor Conditions TOD Correction Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Area GLAZ-01 n 42 GLAZ-02 a 20 GLAZ-03 a 112 Dry Bib —> 90 —> 75 —> 0 ( Jul 1700 LOT) RH Moisture 60 50 15 ( Let = Tilt ShdF IntShd 90 -- n 90 shd n 90 shd n 61.5 Range Wet Bib 15 78 63 27.45 oN Const Wt = M SCMult Sc Sens/A 1.00 0.63 21.1 1.00 0.63 36.5 1.00 0.63 36.5 Mult = 1.0 1— Sens 885 744 4083 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ-01 n 42 42 1.270 14.5 N - 1659 GLAZ-02 a 20 20 1.270 14.5 N - 1119 GLAZ-03 a 112 112 1.270 14.5 N - 6145 WALL-01 n 117 75 0.230 D 12.1 N m 209 WALL-02 a 189 57 0.230 D 27.9 N m 362 FLOR-01 - 273 273 0.009 0 - 0 CEIL-01 - 273 273 0.072 RC-7 35.5 - d 698 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 1 3 250 200 705 564 8to6-E 0 0 0 0 0 0 0 + wright5oft' RightSuite® thNersal 201717.0.17 f5U06570 2017-Jun-1418:50:02 Page 1 ...MAenual JlStetee Attorney Office 2nd Floocrup Cate =CLTD Front Door (aces: E LIGHTS Lamp/blst + fixture W/ft2 W Total Factor Space Sens Schedule W fract Fluor MB + Rec trof 2.00 0 546 1.20 1.0 2236 8to6-E Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 652 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #tft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft' # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft' # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 10 cfm x db Temp Diff 14.6 x 1.10 160 -> x Moist. Diff 61.5 x 0.68 418 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 13946 2255 Envelope 13946 982 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 418 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 14364 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 14364) / ( 1.10 x 20.0 ) = 654 Actual Cooling Fan = 559 9. VENTILATION OA 30 cfm x db Temp Diff 14.6 x 1.10 487 x Moist. Diff 61.5 x 0.68 1273 wrightsoft Right -Suite® lhiversal 201717.0.17 FBU06570 2017Jun-1416:50:02 ...rVNanual J4States Attorney Office 2nd Floor.rup CeIc=DLTD Front Door feces: E Page 2 10. RETURN AIR PLENUM Lights Total power( W) 546 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 14852 2255 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 [ = Mult 1.0 ] - 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ-01 n 42 42 1.270 28.0 1494 GLAZ-02 a 20 20 1.270 28.0 725 GLAZ-03 e 112 112 1.270 28.0 3983 WALL-01 n 117 75 0.230 28.0 482 WALL-02 a 189 57 0.230 28.0 364 FLOR-01 273 273 0.009 28.0 68 CEIL-01 273 273 0.072 28.0 551 15. INFILTRATION Loss 32 cfm x db Temp Diff 28.0 x 1.10 993 16. SUBTOTAL HEATING LOAD FOR SPACE 8659 Envelope 8659 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 260 Less transfer 0 Redistribution 0 IS. VENTILATION OA 30 cfm x db Temp Diff 28.0 x 1.10 938 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 63 cfm x 0.48 g/100cfm/d = 0.9 gpd 340 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 10198 Loss factor x Line 16 Loss + wrightsOft, gightSude® universal 201717.0.17 MU06570 2017Jun-1418:50:02 Page 3 ...rVvianual JlStates Attorney Office 2ntl Floor.rup CaIc=DLTD Front Door faces: E RightSuite® Universal 2017 Load Calculation Job: wrightsofr OFFICE 2 Date: Jun 14, 2017 By: Project. For: State Attorney Office 2sec Street, Fort Pierce, FI j._Zone:ROFFICE 2 LWH: 13.0 x 19.0 x 9.0 1. DESIGN CONDITIONS - COOLING Outdoor Conditions Indoor Conditions TOD Correction Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Area GLAZ-01 a 128 GLAZ-02 a 20 Dry Bib —> 90 —> 75 —> 0 ( Jul 1700 LDT ) RH Moisture 60 50 15 ( Lat = Tilt ShdF IntShd 90 shd n 90 shd n 61.5 Range Wet Bib 15 78 63 27.45 °N Const Wt = M SCMult SC Sens/A 1.00 0.63 36.5 1.00 0.63 36.5 Mult = 1.0 ] — Sens 4666 744 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ-01 a 128 128 1.270 14.5 N - 7023 GLAZ-02 a 20 20 1.270 14.5 N - 1119 WALL-01 e 171 23 0.230 D 27.9 N m 145 FLOR-01 - 247 247 0.009 0 - 0 CEIL-01 - 247 247 0.072 RC-7 35.5 - d 632 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 1 3 250 200 662 529 8to6-E 0 0 0 0 0 0 0 + wrilghtsoft' Right-SudeG Uivemal 201717.0.17 FEU05570 2017-Jun-1418:50:02 Page 1 ... rVdanual JlSfates Attorney DHce 2ntl Flocr.rup CaIc=DLTO Front Door faces: E LIGHTS Lamp/blst + fixture Schedule Fluor MB + Rec trof 8to6-E Fluor MB + Rec trof Fluor MB + Rao trof Fluor MB + Rao trof APPLIANCES / PLUG LOADS Application Schedule Plug load 8to6-E MOTORS Power (hp) #/ft2 Schedule 0 0 0 0 0 0 W/ft' 0.70 #12 0 #/ft2 0 #/fta 0 #/ft2 0 #/ft2 0 0 0 0 W/fta W Total Factor Space Sens W fract 2.00 0 494 1.20 1.0 2023 0 0 0 1.20 1.0 0 0 0 0 1.20 1.0 0 0 0 0 1.20 1.0 0 Usage W 0 1.00 0 1.00 0 1.00 0 1.00 0 1.00 0 1.00 Total Per mtr Stun 0 0 0 0 0 0 Sensible Btuh 3.412 0 0 0 0 0 Load factor 1.00 1.00 1.00 Latent Btuh 0 0 0 0 0 0 Sens Latent 590 0 0 0 0 0 0 0 0 0 0 0 Sens 0 0 0 5. INFILTRATION Sens Latent 10 cfm -> x db Temp Diff 14.6 x 1.10 160 -> x Moist. Diff 61.5 x 0.68 418 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 12354 2119 Envelope 12354 947 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 371 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 12724 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 12724) / ( 1.10 x 20.0 ) = 579 Actual Cooling Fan = 613 9. VENTILATION CA 28 cfm x db Temp Diff 14.6 x 1.10 449 x Moist. Diff 61.5 x 0.68 1172 ' 'wrightsoft^ RightSPaageUHe® lhlversal 201717.0.17 FEU06570 2017Jun-1418:ge2 ` 2 ...rVvlanual JtStetes Attorney OKce 2ntl Floor.rup CeIc=CLTD Fronl Door (etas: E 10. RETURN AIR PLENUM Lights Total power (W) 494 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 13173 2119 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 = ] - [ Mult 1.0 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ-01 a 128 128 1.270 28.0 4552 GLAZ-02 a 20 20 1.270 28.0 725 WALL-01 e 171 23 0.230 28.0 145 FLOR-01 247 247 0.009 28.0 61 CEIL-01 - 247 247 0.072 28.0 498 15. INFILTRATION Loss 31 cfm x db Temp Diff 28.0 x 1.10 957 16. SUBTOTAL HEATING LOAD FOR SPACE 6939 Envelope 6939 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 208 Less transfer 0 Redistribution 0 18. VENTILATION OA 28 cfm x db Temp Diff 28.0 x 1.10 863 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 59 cfm x 0.48 g/100cfm/d = 0.9 gpd 320 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 8332 Loss factor x Line 16 Loss Wrightsoft' RightSuke4DLk ivemal20l7l7.0.17 FEU06570 2017Jun-1418:50:02 ...Nvlanual JlStates Attorney office 2nd Floor.rup Gale =CLTD Front Door faces: E Page 3 RightSuite® Universal 2017 Load Calculation Job: wrightsof r OFFICE 3 Date: Jun 14, 2017 By: Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI j_Zone:OFFICE 3 -•____ _ LWH: 12.0 x 9.0 x 9.0 1. DESIGN CONDITIONS - COOLING ( Jul 1700 LOT) Dry Bib RH Moisture Range Wet Bib Outdoor Conditions —> 90 60 15 78 Indoor Conditions —> 75 50 63 TOD Correction —> 0 Difference 15 61.5 Mult = 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Let = 27.45 °N Const Wt = M) Type Orien Area Tilt ShdF IntShd SCMult SC Sens/A Sens GLAZ-01 w 24 90 — n 1.00 0.63 69.7 1673 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Cir Sens GLAZ-01 w 24 24 1.270 14.5 N - 2115 WALL-01 n 108 108 0.230 D 12.1 N m 300 WALL-02 w 81 57 0.230 D 15.4 N m 202 FLOR-01 - 108 108 0.009 0 - 0 CEIL-01 - 108 108 0.072 RC-7 35.5 - d 276 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 1 2 250 200 430 344 8to6-E 0 0 0 0 0 0 0 2017Jun-1418:50:02 W rItjht50t3' RlghtSuite® universal 201717.0.17 FSU06570 Page 1 ... M7anual .AStates Attomey Office 2nd Floocmp Cale = CLTD Fmnt Doorfaces: E LIGHTS Lamp/blst + fixture W/ft' W Total Factor Space Sens Schedule W frail Fluor MB + Rec trof 2.00 0 216 1.20 1.0 885 8to6-E Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 APPLIANCES/PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 258 0 #/ft2 # 0 0 1.00 0 0 0 0 #/fta # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/fta # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 S. INFILTRATION Sens Latent 0 cfm x db Temp Diff 14.6 x 1.10 0 > x Moist. Diff 61.5 x 0.68 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 4466 974 Envelope 4466 344 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 134 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 4600 (L 8 Sens ) / (Xfer x SupplyTD ) = cfm Est Cooling cfm = ( 4600) / ( 1.10 x 20.0 ) = 209 Actual Cooling Fan = 189 9. VENTILATION OA 15 cfm -> x db Temp Diff 14.6 x 1.10 241 -> x Moist. Diff 61.5 x 0.68 630 WrightSoft' Mghtsuita® lhiversal 201717.0.17 FEU06570 20174un-1418:50:02 Page 2 ...rlManual JlStates AQomey Office 2nd Floor.rup Cate =CLiD Front Door races: E 10. RETURN AIR PLENUM Lights Total power (W) 216 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 4841 974 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TO = (Inside DB - Outside DB) _ ( 70 - 42) = 28 Mult [ = 1.0 ] - 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ-01 w 24 24 1.270 28.0 853 WALL-01 n 108 108 0.230 28.0 694 WALL-02 w 81 57 0.230 28.0 366 FLOR-01 108 108 0.009 28.0 27 CEIL-01 108 108 0.072 28.0 218 15. INFILTRATION Loss 5 cfm x db Temp Diff 28.0 x 1.10 150 16. SUBTOTAL HEATING LOAD FOR SPACE 2308 Envelope 2308 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 69 Less transfer 0 Redistribution 0 18. VENTILATION OA 15 cfm x db Temp Diff 28.0 x 1.10 464 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 20 cfm x 0.48 g/100cfm/d = 0.3 gpd 108 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 2950 Loss factor x Line 16 Loss Wri htsoft' 9 20174un-1418:50:02 wgnt-smte® universal zon lzan rsuassio ... rUAanuel JlStates Attorney ice 2nd Floocrup CaIc=DLTD Front Door far»s: E Page 3 RightSuite® Universal 2017 Load Calculation Job: wrightsoft OFFICE 4 Date: Jun 14, 2017 6y: For: State Attorney Office 2sec Street, Fort Pierce, FI Zone: OFFICE 4 LWH: 12.0 x 9.0 1. DESIGN CONDITIONS - COOLING Outdoor Conditions Indoor Conditions TOD Correction Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Area GLAZ-01 w 24 x 9.0 ( Jul 1700 LDT ) Dry Bib RH Moisture Range Wet Bib —> 90 60 15 78 —> 75 50 63 —> 0 15 61.5 ( Lat = 27.45 °N Const Wt = M) Mult = 1.0 ] — Tilt ShdF IntShd SCMult SC Sens/A Sens 90 -- n 1.00 0.63 69.7 1673 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad CIr Sens GLAZ-01 w 24 24 1.270 14.5 N - 2115 WALL-01 w 81 57 0.230 D 15.4 N m 202 FLOR-01 - 108 108 0.009 0 - 0 CEIL-01 - 108 108 0.072 RC-7 35.5 - d 276 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft2lprsn # people Btuh/prsn Btuh/prsn Office 150 1 2 250 200 430 344 8to6-E 0 0 0 0 0 0 0 LIGHTS Lamp/blst+fixture W/ft2 W Total Factor Schedule W Fluor MB + Rec trof 2.00 0 216 1.20 8to6-E Fluor MB + Rec trof 0 0 0 1.20 Fluor MB + Rec trof 0 0 0 1.20 Fluor MB + Rec trof 0 0 0 1.20 + wrightsoft' Right -Suite® lhwersal201717.0.17 FEU06570 ... rWanual JlSfales Aftomey Ofce2nd Floor.mp CeIc=CLTD Front Doorfams: E Space fract 1.0 1.0 1.0 1.0 Sens 885 0 0 0 2017Jun-14 18:50:02 Page 1 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 258 0 #/ft2 # 0 0 1.00 0 0 0 0 #/fta # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 0 cfm x db Temp Diff 14.6 x 1.10 0 — > x Moist. Diff 61.5 x 0.68 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 4165 974 Envelope 4165 344 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 125 S. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 4290 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 4290) / ( 1.10 x 20.0 ) = 195 Actual Cooling Fan = 157 9. VENTILATION CA 15 cfm —> x db Temp Diff 14.6 x 1.10 241 —� x Moist. Diff 61.5 x 0.68 630 10. RETURN AIR PLENUM Lights Total power (W) 216 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 4532 974 + wrightsoft• Plight -Such® Ihwersal 201717.0.17 FEUD6570 2017Jun-1418:50:02 Page 2 ...rwlanual JVStates Attamey Office 2nd Flocr.rup Cale =CLTD Front Door faces: E SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 [ = ] - Mult 1.0 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ-01 w 24 24 1.270 28.0 853 WALL-01 w 81 57 0.230 28.0 366 FLOR-01 108 108 0.009 28.0 27 CEIL-01 108 108 0.072 28.0 218 15. INFILTRATION Loss 5 cfm x db Temp Diff 28.0 x 1.10 150 16. SUBTOTAL HEATING LOAD FOR SPACE 1614 Envelope 1614 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 48 Less transfer 0 Redistribution 0 18. VENTILATION OA 15 cfm x db Temp Diff 28.0 x 1.10 464 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 20 cfm x 0.48 g/100cfm/d = 0.3 gpd 108 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 2235 Loss factor x Line 16 Loss wr1ghtS0ft' Right -Suite® lhivemal Zan 17.0.17 PSU06670 2017Jun-1418:50:02 Page 3 --- rwanual JlSlales ALLomey Once 2ntl Floor.rup Caic=CLTD Front Door (aces: E wri htsoft Right -Suite® Universal 2017 Load Calculation Job: g OFFICE 5 Date: Jun 14, 2017 By: Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI --Zone:OFFICE 5 LWH: 296.0 x 1.0 x 9.0 1. DESIGN CONDITIONS - COOLING Outdoor Conditions Indoor Conditions TOD Correction Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Area GLAZ-01 n 96 Dry Blb —> 90 —> 75 —> 0 ( Jul 1700 LDT ) RH Moisture 60 50 Range Wet Bib 15 78 63 15 61.5 ( Lat = 27.45 °N Const Wt = M � Mult = 1.0 ] — Tilt. ShdF IntShd SCMult Sc Sens/A Sens 90 -- n 1.00 0.63 21.1 2024 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ-01 n 96 96 1.270 14.5 N - 3792 WALL-01 n 144 48 0.230 D 12.1 N m 134 FLOR-01 - 296 296 0.009 0 - 0 CEIL-01 - 296 296 0.072 RC-7 35.5 - d 757 4. INTERNAL BEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule R'/prsn # people Btuh/prsn Btuh/prsn Office 150 1 3 250 200 743 595 8to6-E 0 0 0 0 0 0 0 LIGHTS Lamp/blst + fixture W/fta W Total Factor Schedule W Fluor MB + Rec trot 2.00 0 592 1.20 8to6-E Fluor MB + Rec trof 0 0 0 1.20 Fluor MB + Rec trof 0 0 0 1.20 Fluor MB + Rec trof 0 0 0 1.20 Space fract 1.0 1.0 1.0 1.0 Sens 2425 0 0 0 + wrightsoft^ Right -Suite® lhiversal201717.0.17 MU05570 20174ur 1418:50:02 Page 1 ... rlMenual JlStates Atlomey Office 2ntl Flocr.rup CaIc=CL7D Frant Ooor faces: E APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 707 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 0 cfm > x db Temp Diff 14.6 x 1.10 0 > x Moist. Diff 61.5 x 0.68 0 6. -SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 8557 1958 Envelope 8557 595 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 257 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 8814 (L 8 Sens ) / ()(far x Supply TD ) = cfm Est Cooling cfm = ( 8814) / ( 1.10 x 20.0 ) = 401 Actual Cooling Fan = 323 9. VENTILATION CA 33 cfm —> x db Temp Diff 14.6 x 1.10 522 > x Moist. Diff 61.5 x 0.68 1363 10. RETURN AIR PLENUM Lights Total power (W) 592 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 9336 1958 + wrilghtSOft' Right 2017Jun-1418:50:02 -Suite lhivemal201717.0.17 PSU08570 ...rwianual JlStates AHomey Once 2ntl Floocmp CaIc=CLTD Front Door faces: E Page 2 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (insideDB- OutsideDB) _ ( 70 - 42) = 28 Mult 1.0 [ = ] - 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ-01 n 96 96 1.270 28.0 3414 WALL-01 n 144 48 0.230 28.0 309 FLOR-01 - 296 296 0.009 28.0 73 CEIL-01 296 296 0.072 28.0 597 15. INFILTRATION Loss 13 cfm x db Temp Diff 28.0 x 1.10 410 16. SUBTOTAL HEATING LOAD FOR SPACE 4803 Envelope 4803 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 144 Less transfer 0 Redistribution 0 18. VENTILATION OA 33 cfm x db Temp Diff 28.0 x 1.10 1004 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 46 cfm x 0.48 g/100cfm/d = 0.7 gpd 249 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 6200 Loss factor x Line 16 Loss Y' Wrightsoft' RightSUHe® universal 201717.0.17 R61106570 2017-Jun-1418:50:02 Page 3 ...Manual JlStates Attorney Office 2nd Floor.rup CaIc=DLTD Front Door (aces: E - wrightsoft' Right -Suite® Universal 2017 Load Calculation Date: Jun 14, 2017 OFFICE 6 By, Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI Zone: OFFICE 6 LWH: 13.0 x 18.0 x 9.0 1. DESIGN CONDITIONS - COOLING ( Jul 1700 LDT ) Dry Bib RH Moisture Range Wet Bib Outdoor Conditions —> 90 60 15 78 Indoor Conditions —> 75 50 63 TOD Correction —> 0 Difference 15 61.5 Mult = 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Lat = 27.45 °N Const Wt = M) Type Orien Area Tilt ShdF IntShd SCMult Sc Sens/A Sens GLAZ-01 a 20 90 shd n 1.00 0.63 36.5 744 GLAZ-02 a 112 90 shd n 1.00 0.63 36.5 4083 3. TRANSMISSION GAINS Type Oden GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ-01 a 20 20 1.270 14.5 N - 1119 GLAZ-02 a 112 112 1.270 14.5 N - 6145 WALL-01 a 162 30 0.230 D 27.9 N m 190 FLOR-01 - 234 234 0.009 0 - 0 CEIL-01 - 234 234 0.072 RC-7 35.5 - d 599 4. INTERNAL HEAT GAIN PEOPLE Activity Schedule Office 8to6-E Sens Latent Total Sensible Latent ft21prsn # people Btuh/prsn Btuh/prsn 150 1 3 250 200 640 512 0 0 0 0 0 0 0 + wrightsof , gight-Su@e® lhiversal 201717.0.17 FSU05570 2017-Jun-1418.50:02 Page 1 ... rlMenual J\States Attorney Once 2ntl Fleor.rup Caic=CLTD Frant Door faces: E LIGHTS Lamp/blst + fixture W/fta W Total Factor Space Sens Schedule W fract Fluor MB + Rec trof 2.00 0 468 1.20 1.0 1917 8to6-E Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 559 0 #/fta # 0 0 1.00 0 0 0 0 #/fta # 0 0 1.00 0 0 0 0 #/fta # 0 0 1.00 0 0 0 0 #/fta # 0 0 1.00 0 0 0 0 #/fta # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/fta # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 S. INFILTRATION Sens Latent 10 cfm -> x db Temp Diff 14.6 x 1.10 160 -� x Moist. Diff 61.5 x 0.68 418 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 11328 2051 Envelope 11328 930 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 340 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 11668 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 11668) / ( 1.10 x 20.0 ) = 531 Actual Cooling Fan = 563 9. VENTILATION OA 27 cfm x db Temp Diff 14.6 x 1.10 429 x Moist. Diff 61.5 x 0.68 1121 + wri htsoft' 2017-Jun-1418:50:02 9 Right-SuEe�Lhiversa1201717.0.17 F6UW570 ... Mlanual AStates Attomey Dffce2ne Floor.mp Calc=CLTD Front Doorfaces: E Paget 10. RETURN AIR PLENUM Lights Total power (W) 468 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 12097 2051 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TO = (Inside DB - Outside DB) _ ( 70 - 42) = 28 [ = Mult 1.0 ] - 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ-01 a 20 20 1.270 28.0 725 GLAZ-02 a 112 112 1.270 28.0 3983 WALL-01 a 162 30 0.230 28.0 190 FLOR-01 - 234 234 0.009 28.0 58 CEIL-01 234 234 0.072 28.0 472 15. INFILTRATION Lass 31 cfm x db Temp Diff 28.0 x 1.10 939 16. SUBTOTAL HEATING LOAD FOR SPACE 6368 Envelope 6368 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 191 Less transfer 0 Redistribution 0 18. VENTILATION CA 27 cfm x db Temp Diff 28.0 x 1.10 826 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1. pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 57 cfm x 0.48 g/100cfm/d = 0.8 gpd 31D Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (11 7696 Loss factor x Line 16 Loss + wrightSoft° Right -Suite® Lhiversal201717.0.17 MU06570 2017.J.n-1418:50:02 Page 3 ...rVvlanua1 J15tates Altomey Office 2nE Floor.rup CaIc=CLTD Front Door faces: E RightSuite® Universal 2017 Load Calculation Job: wrightsoft OFFICE 7 Date: Jun 14, 2017 By: Project Information For. State Attorney Office 2sec Street, Fort Pierce, FI LWH: 13.0 x 18.0 x 9.0 1. DESIGN CONDITIONS - COOLING ( Jul 1700 LDT ) Dry Bib RH Moisture Range Wet Bib Outdoor Conditions —> 90 60 15 78 Indoor Conditions —> 75 50 63 TOD Correction —> 0 Difference 15 61.5 [ Mult = 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Let = 27.45 °N Const Wt = M ) Type Orien Area Tilt ShdF IntShd SCMuit Sc Sens/A Sens GLAZ-01 a 20 90 shd n 1.00 0.63 36.5 744 GLAZ-02 a 112 90 shd n 1.00 0.63 36.5 4083 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ-01 a 20 20 1.270 14.5 N - 1119 GLAZ-02 a 112 112 1.270 14.5 N - 6145 WALL-01 a 162 30 0.230 D 27.9 N rn 190 FLOR-01 - 234 234 0.009 0 - 0 CEIL-01 - 234 234 0.072 RC-7 35.5 - d 599 4. INTERNAL HEAT GAIN PEOPLE Activity Schedule Office 8to6-E Sens Latent Total Sensible Latent ft2/prsn # people Btuh/prsn Btuh/prsn 150 1 3 250 200 640 512 0 0 0 0 0 0 0 wrightsoft RightSudeat Ihiversa1201717.0.17 fSU06570 2017Jun-1418:50:02paae i ...fWanuel Mtates Anomey Of<Ioo 2no Floocmp Calc=CLTD Front Door faces: E LIGHTS Lamp/blst + fixture W/ft2 W Total Factor Space Sens Schedule W frail Fluor MB + Rec trof 2.00 0 468 1.20 1.0 1917 8to6-E Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 559 0 #/fta # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 10 cfm x db Temp Diff 14.6 x 1.10 160 �> x Moist. Diff 61.5 x 0.68 418 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 11328 2051 Envelope 11328 930 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 340 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 11668 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 11668) J ( 1.10 x 20.0 ) = 531 Actual Cooling Fan = 525 9. VENTILATION CA 27 cfm -> x db Temp Diff 14.6 x 1.10 429 -> x Moist. Diff 61.5 x 0.68 1121 Wrightsoft' MghtSuHe® universal 201717.0.17 MU06570 20174un 1418:50:02 ...MAanual J\States Attorney OKce 2nd Floor.rup Cale =CLTD Frant Door (aces: E Page 2 10. RETURN AIR PLENUM Lights Total power (W) 468 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 12097 2051 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 Mult [ = 1.0 ] - 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ-01 a 20 20 1.270 28.0 725 GLAZ-02 a 112 112 1.270 28.0 3983 WALL-01 e 162 30 0.230 28.0 190 FLOR-01 234 234 0.009 28.0 58 CEIL-01 234 234 0.072 28.0 472 15. INFILTRATION Loss 31 cfm x db Temp Diff 28.0 x 1.10 939 16. SUBTOTAL HEATING LOAD FOR SPACE 6368 Envelope 6368 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 191 Less transfer 0 Redistribution 0 18. VENTH.ATION OA 27 cfm x db Temp Diff 28.0 x 1.10 826 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 57 cfm x 0.48 g/100cfm/d = 0.8 gpd 31D Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 7696 Loss factor x Line 16 Loss Wf4 htsoR' 9 Righl-SuitePJ lhiversal 201717.0.17 fSU06570 2017Jun-1418:50:02 ... MManual J%Slales Attomey0Rce2nd Floor.mp Calc=CLTD Front Doorfaces: E Page 3 RightSuite® Universal 2017 Load Calculation Job: wrightsofr oFFrce a Date: Jun 14, 2017 By: Project Information For. State Attorney Office 2sec Street, Fort Pierce, FI Zone:_ - OFFICE __8-- .- - —i LWH: 12.0 x 16.0 x 9.0 I. DESIGN CONDITIONS - COOLING ( Jul 1700 LDT ) Dry Bib RH Moisture Range Wet Bib Outdoor Conditions —> 90 60 15 78 Indoor Conditions —> 75 50 63 TOD Correction —> 0 Difference 15 61.5 Mult = 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Let = 27.45 °N Const Wt = M) Type Orien Area Tilt ShdF IntShd SCMult SC Sens/A Sens GLAZ-01 s 72 90 — n 1.00 0.63 16.5 1190 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ-01 s 72 72 1.270 14.5 N - 2516 WALL-01 s 108 36 0.230 D 16.5 N m 136 FLOR-01 - 192 192 0.009 0 - 0 CEIL-01 - 192 192 0.072 RC-7 35.5 - d 491 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 1 2 250 200 570 456 8to6-E 0 0 0 0 0 0 0 LIGHTS Lamp/blst + fixture W/ft2 W Total Factor Space Sens Schedule W fract Fluor MB + Rec trof 2.00 0 384 1.20 1.0 1573 8to6-E Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 — -- Fluor MB + Rec trof 0 0 0 1.20 1.0 0 + wrightsofr Right-Suite(g) universal 201717.0.17 FSU05570 2017Jun-1418:50:02 Page 1 ...rlManual JlStates Attorney Office 2ntl Flooruup CaIc=CLTD Front Doorfaces: E APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 459 0 #/ft' # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 0 cfm —> x db Temp Diff 14.6 x 1.10 0 x Moist. Diff 61.5 x 0.68 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 5745 1413 Envelope 5745 456 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 172 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 5917 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 5917) / ( 1.10 x 20.0 ) = 269 Actual Cooling Fan = 246 9. VENTILATION OA 23 cfm > x db Temp Diff 14.6 x 1.10 367 —> x Moist. Diff 61.5 x 0.68 957 10. RETURN AIR PLENUM Lights Total power( W) 384 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 6284 1413 2017-Jun-1418:50:02 + WrIghtSoft' {tight -Sucre® Ihiversai 201717.0.17 PSU08570 Page 2 ... Manual J\States Altomey Office 2nd Flocr.rup Cale=CLTD Fiunt Dcorfaces: E SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ-01 s 72 72 1.270 28.0 2560 WALL-01 s 108 36 0.230 28.0 231 FLOR-01 192 192 0.009 28.0 48 CEIL-01 192 192 0.072 28.0 387 15. INFILTRATION Loss 9 cfm x db Temp Diff 28.0 x 1.10 266 16. SUBTOTAL HEATING LOAD FOR SPACE 3493 Envelope 3493 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 105 Less transfer 0 Redistribution 0 18. VENTILATION OA 23 cfm x db Temp Diff 28.0 x 1.10 705 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 32 cfm x 0.48 g/100cfm/d = 0.5 gpd 171) Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 4474 Loss factor x Line 16 Loss 2017Jun-1418.50:02 wrightSGf`t" Right SOe® universal 201717.0.17 PSU05570 Page 3 ... rXManual ftStates Atlomey Office2ne Floor.mp Calc=CLM Front Doorfaces: E wtlghtsOft' Right -Suite® Universal 2017 Load Calculation Job:DateJunta, zon OFFICE 9 By, For: State Attorney Office 2sec Street, Fort Pierce, FI Zone: OFFICE 9 LWH: 13.0 x 25.0 x 9.0 1. DESIGN CONDITIONS - COOLING ( Jul 1700 LDT ) Dry Bib RH Moisture Range Wet Bib Outdoor Conditions —> 90 60 15 78 Indoor Conditions —> 75 50 63 TOD Correction —> 0 Difference 15 61.5 Mult = 1.0 ] — 2. GLAZING SOLAR HEAT GAIN ( Let = 27.45 °N Const Wt = M) Type Orien Area Tilt ShdF IntShd SCMult SC Sens/A Sens GLAZ-01 s 30 90 — n 1.00 0.63 16.5 496 GLAZ-02 w 32 90 — n 1.00 0.63 69.7 2230 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens GLAZ-01 s 30 30 1.270 14.5 N - 1048 GLAZ-02 w 32 32 1.270 14.5 N - 2819 WALL-01 s 117 87 0.230 D 16.5 N m 330 WALL-02 w 225 193 0.230 D 15.4 N m 684 FLOR-01 - 325 325 0.009 0 - 0 CEIL-01 - 325 325 0.072 RC-7 35.5 - d 831 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 1 3 250 200 792 633 8to6-E 0 0 0 0 0 0 0 + wrightsOft glghlSuite® lhiversal 201717.0.17 FISU06570 ...rXMa ualJl6tates Attomey Of(Ice2nd Floor.rup Calc=CLTD Fmnl Doorfaces: E 2017-Jun-1416:50:02 Page 1 LIGHTS Lamp/blst + fixture W/ft2 W Total Factor Space Sens Schedule W fract Fluor MB + Rec trof 2.00 0 650 1.20 1.0 2662 8to6-E Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W12 W 8to6-E 0.70 0 1.00 3.412 0 776 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 0 cfm -> x db Temp Diff 14.6 x 1.10 0 -> x Moist. Diff 61.5 x 0.68 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 9943 2109 Envelope 9943 633 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 298 S. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 10241 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 10241) / ( 1.10 x 20.0 ) = 466 Actual Cooling Fan = 421 9. VENTILATION OA 35 cfm x db Temp Diff 14.6 x 1.10 565 �> x Moist. Diff 61.5 x 0.68 1476 - wright�sofr Rghl-Suite® lhivemal 201717.0.17 MU06570 2017-Jun-1418:Paagege2 2 ... rNAanual JlStates Attorney Office 2ntl Floor.rup CaIc=CLTO Front Door races: E 10. RETURN AIR PLENUM Lights Total power (W) 650 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 10806 2109 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 Mult [ = 1.0 ] - 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss GLAZ-01 S 30 30 1.270 28.0 1067 GLAZ-02 w 32 32 1.270 28.0 1138 WALL-01 s 117 87 0.230 28.0 559 WALL-02 w 225 193 0.230 28.0 1241 FLOR-01 325 325 0.009 28.0 81 CEIL-01 325 325 0.072 28.0 656 15. INFILTRATION Loss 15 cfm x db Temp Diff 28.0 x 1.10 450 16. SUBTOTAL HEATING LOAD FOR SPACE 5191 Envelope 5191 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 156 Less transfer 0 Redistribution 0 18. VENTILATION CA 35 cfm x db Temp Diff 28.0 x 1.10 1087 19. HUMIDIFICATION Inside RH desired 32.0 (Max = 32.0 for 1 pane ) # of Glazing panes 1.0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 50 cfm x 0.48 g1100cfm/d = 0.7 gpd 270 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 6705 Loss factor x Line 16 Loss wrightSOW RightSuite® lhivemal 201717.0.17 MU06570 2017Jun-1418:50:02 _.riManual JlStalas Attorney Office 2ntl Floor.rup CaIc=CLTD Front Door faces: E Page 3 Right -Suite® Universal 2017 Load Calculation Job: wrightsoft RECEPTION Date: Jun 14, 2017 By: Project Information For: State Attorney Office 2sec Street, Fort Pierce, FI ;__ Zone___RECEPTION l LWH: 504.0 x 1.0 x 9.0 1. DESIGN CONDITIONS - COOLING ( Jul 1700 LDT ) Dry Bib RH Moisture Range Wet Bib Outdoor Conditions —> 90 60 15 78 Indoor Conditions —> 75 50 63 TOD Correction —> 0 Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Area 15 61.5 [ Mult = 1.0 ] — ( Lat = 27.45 °N Const Wt = M ) Tilt ShdF IntShd SCMult Sc Sens/A Sens 3. TRANSMISSION GAINS Type Orien GrArea NtArea Uval Grp CLTD Shad Clr Sens FLOR-01 - 504 504 0.009 0 - - 0 CEIL-01 - 504 504 0.072 RC-7 35.5 - d 1289 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 1 4 250 200 1090 872 8to6-E 0 0 0 0 0 0 0 LIGHTS Lamp/blst + fixture Schedule Fluor MB + Rec trof 8to6-E Fluor MB + Rec trof Fluor MB + Rec trot Fluor MB + Rec trof W/ft2 W Total Factor Space Sens W fract 2.00 0 1008 1.20 1.0 4128 0 0 0 1.20 1.0 0 0 0 0 1.20 1.0 0 0 0 0 1.20 1.0 0 wrightsof2017Jun-1418:50:02 C RightSune® universal201717.0.17 PSU06570 Page 1 ...Manoal AStates AHonney Office 2nd Floocrup Cak=CLTD Front Doorfaoes: E APPLIANCES / PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 1204 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 0 cfm � x db Temp Diff 14.6 x 1.10 0 —> x Moist. Diff 61.5 x 0.68 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 7711 3046 Envelope 7711 872 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 231 8. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 7943 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 7943) / ( 1.10 x 20.0 ) = 361 Actual Cooling Fan = 350 9. VENTILATION OA 52 cfm x db Temp Diff 14.6 x 1.10 832 —> x Moist. Diff 61.5 x 0.68 2174 10. RETURN AIR PLENUM Lights Total power (W) 1008 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 8775 3046 WI'1 httscfY 9 Right -Suite® Universal 201717.0.17 FCUD6570 2017Jun-1418.50:02 ...r%Manual JlStates Attomey OKce2nd Floocmp Calc=CLTD Front Dcorfaces: E Page 2 SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TO = (Inside DB - Outside DB) _ ( 70 - 42) = 28 [ = ] - Mult 1.0 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss FLOR-01 504 504 0.009 28.0 125 CEIL-01 504 504 0.072 28.0 1017 15. INFILTRATION Loss 23 cfm x db Temp Diff 28.0 x 1.10 698 16. SUBTOTAL HEATING LOAD FOR SPACE 1840 Envelope 1840 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 55 Less transfer 0 Redistribution 0 18. VENTILATION OA 52 cfm x db Temp Diff 28.0 x 1.10 1601 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 75 cfm x 0.20 g1100cfm/d = 2.4 gpd 900 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 4400 Loss factor x Line 16 Loss Wri ht50ft 2017Jun-141e:50:02 9 Righl-Suite® Universal 201717.0.17 FOU06570 Page 3 ...rlManual JlStales AUomey Offim2nd Floor.mp Calc=CLTD Front Doorfaces: E RightSuite® Universal 2017 Load Calculation Job: wrightsoftDate: Jun 14, 2017 STORAGE 1 By: InformationProject For: State Attorney Office 2sec Street, Fort Pierce, FI --- -------------- _Zones�_ ST-ORAGE 1 LWH: 12.0 x 6.0 x 9.0 1. DESIGN CONDITIONS - COOLING Outdoor Conditions —> Indoor Conditions —> TOD Correction —> Difference 2. GLAZING SOLAR HEAT GAIN Type Orien Area Tilt Dry Bib 90 75 0 15 ( Let ShdF IntShd ( Jul 1700 LDT ) RH Moisture 60 50 Range 15 61.5 27.45 °N Const Wt = M SCMult Sc Sens/A Wet Bib 78 63 Mult = 1.0 ] — Sens 3. TRANSMISSION GAINS Type Orien GrArea WALL-01 w 54 FLOR-01 - 72 CEIL-01 - 72 NtArea 54 72 72 Uval 0.230 0.009 0.072 Grp D RC-7 CLTD 15.4 0 35.5 Shad N - - Clr In d Sens 191 0 184 4. INTERNAL HEAT GAIN PEOPLE Sens Latent Activity Total Sensible Latent Schedule ft2/prsn # people Btuh/prsn Btuh/prsn Office 150 1 1 250 200 370 296 8to6-E 0 0 0 0 0 0 0 LIGHTS Lamp/blst+fixture W/ft2 W Total Factor Space Sens Schedule W fract Fluor MB + Rec trof 2.00 0 144 1.20 1.0 590 8to6-E Fluor MB + Rec trot 0 0 0 1.20 1.0 0 Fluor MB + Rec trof 0 0 0 1.20 1.0 0 Fluor MB_+ Rec trof 0 0 0 1.20 1.0 0 wrightsoft' RightSuite® Lhivemal 201717.0.17 MUD6570 2017Jun-1418:50:02 ...rUAanual JlSlates Attorney Once 2ntl Floor.rup Cale =CLTD Front Doorfaces: E Page 1 APPLIANCES/PLUG LOADS Application Usage Sensible Latent Sens Latent Schedule Btuh Btuh Plug load W/ft2 W 8to6-E 0.70 0 1.00 3.412 0 172 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 #/ft2 # 0 0 1.00 0 0 0 0 Wit" # 0 0 1.00 0 0 0 0 #Ift' # 0 0 1.00 0 0 0 0 MOTORS Power (hp) #/ft2 # Total Per mtr Load Sens Schedule Btuh factor 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 0 0 0 0 0 1.00 0 5. INFILTRATION Sens Latent 0 Dim -> x db Temp Diff 14.6 x 1.10 0 —> x Moist. Diff 61.5 x 0.68 0 6. SUBTOTAL COOLING LOAD FOR SPACE Sensible Latent 1507 786 Envelope 1507 296 Less external cooling 0 Redistribution 0 0 7. SUPPLY DUCT HEAT GAIN Gain factor 0.03 x Line 6 Sensible Gain 45 S. COOLING FAN SIZING Sum of Duct Gain (7 ), Line (6) & Drawthru Fan = 1553 (L 8 Sens ) / (Xfer x Supply TD ) = cfm Est Cooling cfm = ( 1553) / ( 1.10 x 20.0 ) = 71 Actual Cooling Fan = 68 9. VENTILATION CA 12 cfrn > x db Temp Diff 14.6 x 1.10 187 > x Moist. Diff 61.5 x 0.68 490 10. RETURN AIR PLENUM Lights Total power (W) 144 0 Transmission load (plenum upper surface) 0 Space load credit (plenum lower surface) 0 11. RETURN DUCT HEAT GAIN Gain factor 0 x Line 6 Sensible Gain 0 12. TOTAL COOLING LOADS ON EQUIPMENT (Btuh) 1740 786 wrightsOft Rght-Sui.GUnwersal 201717.0.17 FSUWPaage570 2017Jun-1418:ge2 2 ...rlManual JlStetes Attorney Office 2ntl Floot.rup CaIc=CLTD Front Door faces: E SPACE HEATING LOAD CALCULATION 13. HEATING DESIGN TEMPERATURE Heating TD = (Inside DB - Outside DB) _ ( 70 - 42) = 28 [ Mult 1.0 = ] - 14. TRANSMISSION LOSSES Type Expos GrArea NetArea Uval HTD Loss WALL-01 w 54 54 0.230 28.0 347 FLOR-01 72 72 0.009 28.0 18 CEIL-01 72 72 0.072 28.0 145 15. INFILTRATION Loss 3 cfm x db Temp Diff 28.0 x 1.10 100 16. SUBTOTAL HEATING LOAD FOR SPACE 610 Envelope 610 Less external heating 0 Less transfer 0 Redistribution 0 17. SUPPLY DUCT HEAT LOSS Loss factor 0.03 x Line 16 Loss 18 Less transfer 0 Redistribution 0 18. VENTILATION OA 12 cfm x db Temp Diff 28.0 x 1.10 361 19. HUMIDIFICATION Inside RH desired 40.0 (Max = 32.0 for 1 pane ) # of Glazing panes 0 (Max = 52.0 for 2 pane ) 20. RETURN DUCT HEAT LOSS 15 cfm x 0.20 g/100cfm/d = 0.5 gpd 180 Piping 0 21. TOTAL HEATING LOAD ON EQUPMENT (Btuh) 1170 Loss factor x Line 16 Loss wri htsoft' 2017Jun-1418:50:02 9 RightSuite® lhiversal 207717.0.17 PSU06570 ... rlManualAStates ARomey0ffee2nd F)oor.mp Calc=CLTD Fmnt Doorfaces: E Page 3 FR INTAKE Unt Cneanaide FRESHAIRE 134tlm UnATwowmlde FRESHAIRE IN CFM Unit Trite odedMe Fmhaire 147 CFM Eat, system wM need a V hesll NMke a5 Wt,eSwe Job M Performed for: Stale Attomey Office 2see Street Fort Medea, FI Scale: 1 : 152 Page 1 RightSuile® Universal 2017 17.0.17 RSU06570 2017Jun-14 18:50:42 ...es Attomey Office 2nd Floomp