HomeMy WebLinkAboutMISC EMAIL7
i
PAT L WELCH INC.
Mechanical * Electrical * Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com
SCANNED
BY
July 7, 2017 St. Lucie County
Re: Lakewood Park Ass. Shutter Installation
7508 Jennings Way
Fort Pierce, FL 34951
To Whom It May Concern:
Our office has calculated the required design pressures in accordance with ASCE 7-10
and Florida Building Code 2014 for the installation of the shutters at the above referenced
address.
Wind speed:
Vic: 160 mph, Via: 124 mph
Exposure:
C
Enclosure Type:
Enclosed
Shutter Size:
58" Maximum Height
Shutter Location:
See Attached Sketch
Required Design Pressure: +38.7/ -51.8 PSF (Worst Case / Zone 5)
Shutters to be installed shall be equal to, or exceed the required design pressures as listed
above "Required Design Pressure".
Shutters shall be installed in accordance with the shutter manufacturer's installation
instructions and Florida Product Approval and Florida Building Code 2014.
Shutters shall be Eastern Metal Supply Storm Panels (FL# 11968.4) for "Panels"
And American Shutter Systems Association, Inc (FL# 389.2) for "Accordion"
Thank you for your attention to this matter.
Subn4tted by:
PAT ill WELCH INC.
Paul elch, P:E.
Reg. No 29945 ti