Loading...
HomeMy WebLinkAboutMISC EMAIL7 i PAT L WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pwelchinc@aol.com SCANNED BY July 7, 2017 St. Lucie County Re: Lakewood Park Ass. Shutter Installation 7508 Jennings Way Fort Pierce, FL 34951 To Whom It May Concern: Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2014 for the installation of the shutters at the above referenced address. Wind speed: Vic: 160 mph, Via: 124 mph Exposure: C Enclosure Type: Enclosed Shutter Size: 58" Maximum Height Shutter Location: See Attached Sketch Required Design Pressure: +38.7/ -51.8 PSF (Worst Case / Zone 5) Shutters to be installed shall be equal to, or exceed the required design pressures as listed above "Required Design Pressure". Shutters shall be installed in accordance with the shutter manufacturer's installation instructions and Florida Product Approval and Florida Building Code 2014. Shutters shall be Eastern Metal Supply Storm Panels (FL# 11968.4) for "Panels" And American Shutter Systems Association, Inc (FL# 389.2) for "Accordion" Thank you for your attention to this matter. Subn4tted by: PAT ill WELCH INC. Paul elch, P:E. Reg. No 29945 ti