Low -Voltage Automatic Transfer Switches
C
GE's Zenith ZTG Series switches are built for
standard applications requiring the dependability
and ease of operation found in a power
itactor switch.
Ratings 40 to 3000 amps (2, 3 or 4 poles)
UL 1008 listed at 480 VAC
• CSA certified at 600 VAC
(200-260 amps - 480V)
• NFPA 70, 99, 101 and 110
• IEEE 446 and 241
• NEC 517. 700, 701 and 702
• NEMA ICS2-447
• UL 508 and 50
•. ANSI C33.76
• ICS 6
• NEMA 250
• Equipment (Controls and Power Section)
Seismic Test Qualified to:
✓ IBC-2006
✓ IEEE-693-2005
• Double throw, mechanically
interlocked contactor mechanism
• Electrically operated, mechanically held
C�esigned for emergency and
.,mndby applications
• Available in standard (ZTG) or
delayed transition (ZTGD) models
Fully Approved
• UL and CSA listed
• NFPA 70. 99 101 and 110
• IEEE 446 and 241
• NEC 517. 700.701 and 702
• NEMA ICS2-447
• UL 508 and 50
• ANSI C33.76
• ICS 6
• NEMA 250
• IBC-2006
• IEEE-693-2005
• Ringing wave immunity per
IEEE 472 (ANSI C37.90A)
ZTG switches are equipped with GE's Zenith
MX150 microprocessor panel, which controls
the operation and displays the status of the
transferswitch's position, timers and available
sources. As an embedded digital controller,
the MX150 offers high reliability and ease of
unattended operation across a range of
applications. The MX150 features include:
• Timer and voltage/frequency settings
adjustable without disconnection from
the power section
• Built-in diagnostics with an LCD display
for immediate troubleshooting
• LED/LCD indicators for ease of viewing
and long life
• Nonvolatile memory —clock battery backup
not required for standard switch operation
• Processor and digital circuitry isolated
from line voltage
• Inputs optoisolated for high electrical
immunity to transients and noise
• Communications network interface
• Conducted and Radiated Emissions per
EN55022 Class B (CISPR 22) (Exceeds
EN55011 & MILSTD 461 Class 3)
• ESD immunity test per EN61000-4-2
Class B (Level 4)
• Radiated RF, electromagnetic field
immunity test per EN61000-4-3
(ENV50140) 10v/m
• Electrical fast transient/burst immunity
test per EN61000-4-4
• Surge immunity test per EN61000-4-5
IEEE C62.41(1.2 X 50ps, 0.5 & 4 kV)
• Conducted immunity test per
EN61000-4-6IENV50141)
• Voltage dips and interruption immunity
EN61000-4-11
Design and Construction Features
• Close differential 3 phase under -voltage
sensing of Source 1(normal)—factory
standard setting 90% pickup, 80%
dropout (adjustable): under -frequency
sensing of Source 1 factory setting
95% pickup (adjustable)
• Voltage and frequency sensing of the
Source 2 (emergency) —factory standard
setting 90% pickup voltage, 95% pickup
frequency (adjustable)
• Test switch (fast test/lood/no load) to
simulate Source 1 [normal) failure —
automatically bypassed should the
Source 2 (emergency) fail
• NEMA Type 1 enclosure is standard —
also available in open style or NEMA .
Types 3R, 4, 4X or 12
PS-1201 • Page 2
MX150 Control Panel
F
tNON 1 a,. pP�R 2va 1(a
i
e
nln�nin,
Front View
C
Standard Features (MSTDG Option Pkg.)
6/P Test Switch, Momentary
A3 Auxiliary Contact Closed when the switch Is in the Source 2 position (S2)
A4 Auxiliary Contact Closed when the switch is in the Source 1 position IS1)
CALIBRATE Capabilities are available for Frequency and AS, BC, CA Phase to Phase
voltage for both Sources
CDT Daily 7.14, 28 timed exercise (CDT memory backup battery included),
pushbutton/timer operation
E Engine Start Contact
EL/P Event Log of 16 Events that track date, time, reason and action taken
.11E Adjustable under frequency sensor for S2
KIP Voltage and Frequency Indication for Sl and S2
L Indicating LED Pilot Lights:
Ll Indicates switch in S2 position
L2 Indicates switch in Sl position
L3 Indicates Sl source available
L4 Indicates S2 source available
P3 Time Delay to Engine Start
Q2 Peak Shave / Remote Load Test
RSO In -Phase Monitor, self-adjusting
T Time Delay on Retransfer to Normal: To delay retransfer to Sl
(immediate retransfer on S2 failure)
R2E Under voltage sensing of S2
S13 Microprocessor activated commit / no commit on tronferring to S2
U Time Delay for Engine Cool Down: Allows engine to run unloaded after
switch retransfer to Sl
W Time Delay onTransfertoEmergency.Todelay transfer toS2after availability
YEN Pushbutton Bypass of T & W Timers
When specified for use with a ZTGD Series delayed transition switch, the control panel
also includes the following:
DT Time Delay from Neutral Switch Position to Sl on Retransfer
DW Time Delay from Neutral Switch Position to S2
LN/P Center -Off position/Off Delay Timing indicating lights
Additional Standard Features WEXEG Option Pkg.)
CDP Clock Exerciser Load/No Load (Replaces CDT Exerciser Option)
VI Voltage Imbalance Monitor (Three Phase)
Page 3 . PS-1201
Zenith ZTG Series Ordering Information
I`I JI I AO ❑ �— ZEC ZVC
('EL/IY9E CONTROL APPLICATION AMPERESIZE SWITCHEDENCLOSURET'PE OPERATIONAL VOLTAGE ACCESSORIES
PANEL POLES
Z IT, G, 16.1 01: _6
SwMa (Open Tmm oN
Z T G D 0 F01
DdryeETra t.
Switch Types
A. 0'
K
GUif 3wnsh 130
U64y-Gmerotas
Mia4pmcess4r
ca�trdud2
U
❑
uany-uu4y
M❑
Monad Tmmfer
• Standard: Unless otherwise noted, the
standard switch with quick transfer will
be supplied.
• Delayed Transition: When ordered as
the ZTGD, the delayed transition switch
offers time delay during transfer from
one position to the other. This is primarily
for transfer of large motor or inductive
loads. The operation of the delayed
transition switch Is totally independent
the synchronism of the power sources.
_,Im noting the need for in -phase monitors
or extensive motor -disconnect control
wiring between the transfer switch and
motor control centers.
Example
ZTGO00A00040E-ZECOMC4014STD
This number string shows the correct format
for a ZTG Series Automatic Transfer Switch
with an MX150 microprocessor control unit,
Utility - Generator, 400 amps, 4 pole, NEMA
Type 1 enclosure,120/208V 3�, 4 wire, 60 Hz
system with the standard group of accessories.
UL 1008 Withstand
and Closing Ratings
Please refer to GE Publication TB-1102.
A,. 0, 4
El
40mnps 2M.
mks 3N.
30 ., Opole:
sso mws
zoo amps
ti3 amps
2E0mnps
Oro amps
6 6' O'
600 amps
84p mops
loon mope
Szao mop:
1 § 70
1604 m1ip5
12 Q ,0
zaoopmn
Z400 amps
34oa amps
M
Type 3 End..
Type 12 eWosme
3 R
Type 3R Endosme
4 0
Toe4Endo m
4 X
Type4%e m.
0 0
opmsveum
A B
cmwnraei4 edon
M E X E
M A N O
0
120
1
2 wire
60
0
120/240
1
3 wire
60
2
110/220
1
3 wire
50
0
240
3
3 wire
60
1
208
3
3 Wire
60
2
220
3
3 wire
50
5
139/240
3
4 wire
60
0
120/208
3
4 wire
60
1
127/220
;3
4 wire
60
2
127/220
3
4 wire
50
0
480
3
3 wire
60
1
440
3
3 Wire
60
2
440
3
3 Wire
50
5
460
1
3 wire
50
7
480
1
2 wire
60
8
254/440
3
4 wire
60
0
575
3
3 wire
60
1
347/600
3
4 Wire
60
3
575
1
2 Wire
60
0
277/480
3
4 Wire
60
1
277
1
2 Wire
60
4
266/460
3
4 wire
60
5
460
3
3 wire
60
2
380
1
2 wire
50
0
240/416
3
4 wire
60
1
2201380
3
4 Wire
60
2
220/380
3
4 wire
50
3
240/416
3
4 wire
50
7
380
3
3 wire
60
Note Operating voltage must bespecified attime of order.
Only the most common voltages are shown above.
Then dcose
ad&fiwW as<ecwdes
6A
6AP
Al
AlE
A3
A4
A62
ATGEW-X
CTAP
DS
LCM
M90
M90A
M908
M91
M91A
M91B
MCM
OCVR-15G
OCVR-15S
T3/1N3;
UMD�
>�VI
None
PS-1201 • Page 4
Options
6A Test Switch, Maintained
6AP Test Switch, Maintained Programmable
Al Auxiliary Contact, operates on Source 1 line failure
A3E Auxiliary Contact, operates on Source 2 line failure
A3 Auxiliary Contacts: Closed when the transfer switch is in Source 2 position
A4 Auxiliary Contacts: Closed when the transfer switch is in Source 1 position
A62 Sequential Universal Motor Load Disconnect Circuit. Normally closed
Auxiliary contacts for Motor Loads. Open 0-60 seconds plor to transfer,
after transfer, or both in either direction then reclose in timed sequence
after transfer.
ATGEW-X[Extended annual parts and labor warranty (1-4years for a totol of 5 years max)
CLAP Alarm panel on transfer to emergency w/silence button & light
DS Inhibits transfer in either direction when in inhibit. Allows automatic
operation when in Auto (Standard on 800A and above)
HT Heater and Thermostat
LCM LonWorks Communication Module
MCM Modbus RTU Communication Module
M90 Series Power Measurement Meters (Not available in NEMA 4 enclosure)
M90
EPM2000 True RMS Digital Meter with display (Amps, Volts, Power,
Energy, Power Factory and Frequency). 3 Line LED Display.50/60 Hz
Universal Operation. 1 or 3 phase. Standard Modbus RTU RS485
C_
communications capability. 40 -1200 Amps.
M90A
Adds Pre -Wiring for Enervista Viewpoint Monitoring of M90
Accessory & ATS Status using Modbus RS485 Serial Communications
M90B
Adds Pre -Wiring for Enervista Viewpoint Monitoring of M90
Accessory & ATS Status using Ethernet TCP/IP Communications
M91
EPM6000 True RMS Digital Meter with display (Amps, Volts, Power,
Energy, Power Factory and Frequency, THD). Certified energy and
demand metering. Meets ANSI C12.20 and IEC 687 Accuracy Classes.
Front IrDA Part Laptop Connection. Standard Modbus RTU RS485 or
DNP 3.0 communications capability.
M91A
Adds Pre -Wiring for Enervista Viewpoint Monitoring of M91
Accessory & ATS Status using Modbus RS485 Serial Communications
M91B
Adds Pre -Wiring for Enervista Viewpoint Monitoring of M91
Accessory & ATS Status using Ethernet TCP/IP Communications
OCVR-1SG
Lockable see -through microprocessor cover for NEMA 3R or 12
OCVR-1SS
Lockable see -through microprocessor and meters cover for NEMA 311 or 12
—
T3/W3;
T
Elevator _Pre Signal Auxiliary Contacts Open 0-60 seconds.prior to
iransfer`t_oeitherdirectiori re closesaftertrarisfer
�Unwersal Motor Load Disconnectiircmt Auxiligry Contact opens,
0 5 minutes priorto transfer in either dir6di n, re closes after transfer'
;Can be configured by end user forPre transfer, Pos[ transfer or both.
VI
Voltage Imbalance Monitor (Three Phase)
NOTE:
For additional options or other configurations, contact the GE factory.
Page 5 • PB-1201
Reference Charts
Testing Standards
JL and CSA listed
UL 1008, CSA 22.2 No.178
Ringing wave Immunity
IEEE 472 (ANSI C37.90A)
Conducted and radiated emissions
EN55022 Class B (CISPR 22)
(Exceeds EN55011 & MILSTD 461 Class 3)
ESD immunity test
EN61000-4-2 Class B (Level 4)
Radiated RF, electromagnetic field immunity test
EN61000-4-3 (ENV50140)10v/m
Electrical fast, transient/burst immunity test
EN61000-4-4
Surge Immunity test
EN61000-4-5 IEEE C62.41 1.2 X 50Ns, 0.5 to 4 kV
Conducted immunity test
EN61000-4-6 (ENV50141)
Voltage dips and interruption immunity
EN61000-4-11
18-1201 • POge 6
Dimensional and Weight Specifications
.. Tg.
Am•Model Application
RaHelght Width Depth Ref. Open NEMA1Notes
(A) (a) (C) Figure Type'W0_ 14_(6j� ,691311i
;1.00, 1$Oi i2416_ll! 18:1461'4 111281
20T9)!_. '75J34)'
v_ _ _ _ _ _59 (27)69131)/
225, r -- — - 'A --
4 70(321,., - 751341
, - 591271t — 4114 (52)'
t260' �23 -46 (1171 24(61) 14(36)
--- 2 3' _ '71132)__..: 224 (102),'
ZTGi '�600� 4 ; '66 (1681 ,- 24 (61) 19S (50)� _ _ _ ..
'-_2141971'
toa1901861_�.;. 460_I209)i
4, _ 210;1951"._ 490 (2221,
—'741188) ' 4011021, 19.5 —_ _.
,10_00 1200' 3 ----" ' - - ..' '- _ ...._ 190.(815... :47512161P
' -- - - -- - - _- 210(951..a 560:1254)1
34511561- 103014671!
147 7. 450 (204) 1180 (535P
;90(229) "35.5190) �481122) C.
3- - -- , - - - . 46512111- _ 11501522i
I260Q 3000 _ _ _
_. _ .c.. _ •._.; .- _ ... -_- -, .. _ _ _6701304)_ 1_ (635)!
C 40.80 2.3 18(8) 1271581
100,150
200,225 1- 6
4 4611171 241611 14(36) A 241111 133 (601
260,400 2.3 651291 176180)
4 76 f34) 188 (851 1 5
• ZTGD 600 2.3
66(168) 24(61) 19.5 (50) 77(35) 2211100)
4 8 87 (391 230 (104)
1-5,7
800.1000,1200 43 74 (188) 40(1.021 19.5 (50) 210 (951 475 (2151
230 (104) 560 (254)
1600, 2000 4 365 (166) 1030 (467)
901229) 35.5(90) 48 (122) C 470(213) 11801535)
2600, 3000 4 4851220/ 11501522) 1- 5, 7-8
69013131 14001635)
L Metric dimensions Icm) and weights (kg) shown in
Parentheses adjacent to English measurements. Reference Figures
2. Includes 1.25" door projection beyond base depth
Mavaminimum of3chies. orwldepth far
etc. coon
of handle, lights, swatches, pushbuttons, etc. I I M
3. Alldimensionsandweghtsareapproximato and J,
subject to change without notice.❑4. Pocking materials must be added to weights shownAllow IS% additional weight for cartons, skids, A AA
crates, etc5. Special enclosure (NEMA 3R, 4,4x, 12, etcJ
GE
i ensions factoryford tails.5may ddfer. Consuitthe
GEfactory for details.
6. AZTG(D)40-225A,when ordered with the fallowing FgureA Figure6
G options, will require a larger enclosure:A62M. Figure C
Digital Meter, HT, OCVR-1SG, OCVR-1SS.
Contact the GE factory for dimensions.
7. Add 3' in height for removable firing eyes.
8. Ventilation lowers on side and rear of enclosure
at 1600-3000 amps. One set of lowers must be
clear for airflow With standard cable connections.
Page 7 • PS-1201
View full-size in new tab
Rheem RH1P3617STANDA - 3 Ton Air Handier,17" Wide,
PSC Motor, Single -Stage Airflow, Aluminum Evaporator
Coil, 480/3/60
Item: RH1P3617STANDA MFR: RH1P3617STANDA
What's the price?
Sign in or register for pricing.
Quantity `
1
Add to Cart
Your Order Templates
Save products for later, or create lists to quickly re -buy items for routine jobs.
Add to Order Template
Inventory At Nearby Branches
Florida
0 Boynton Beach #106
0 Hollywood #111
0 Kendall #116
0 Miami #113'
0 Naples #165
28 Pompano Beach #109
0 Port St Lucie #103
0 Tamarac #108
0 West Palm Beach #105
All Branches
Skip To Section
Description
Specifications
Parts List
Description
Features include:
• Versatile 4-way convertible design for upflow, downflow, horizontal left and horizontal right
applications.
• Factory -installed indoor coil.
• Sturdy cabinet construction with 1.0 inch [25A mm] of foil faced insulation for excellent sound and
insulating characteristics.
• Field -installed auxiliary electric heater kits provide exact heat for indoor comfort. Kits include
circuit breakers which meet U.L. and cUL requirements for service disconnect.
• 11/2 ton [5.3 kW] through 5 ton [17.6 kW] models are between 421/2 to 551/2 inches [1080 to 1410
mm] tall and 22 inches [559 mm] deep.
• All models meet or exceed 330 to 400 CFM [156 to 189 Us] per ton at .3 inches [.7 kPa] of external
static pressure.
• Enhanced airflow up to .7" external static pressure.
• Evaporator is constructed of aluminum fins bonded to internally grooved aluminum tubing.
Specifications
32
Suction Line Fitting
Sweat
Suction Line Size
3/4"
Motor Type
PSC
Liquid Line Fitting
Sweat
Liquid Line Size
318"
Certifications
AHRI, ISO 9001:2008
Color
Gray
Warranty Offered
10 Year Conditional Parts with Registration
Energy Star Rated
No
LEED Certified
No
UL Listed
Yes
UL Recognized
No
Product Family
RH1P
Tonnage
3
Tier
Standard Efficiency
GEM - Case Quantity
Parts List
Online Only via Direct Ship
PROTECH 42-19736-02 - Relay - SPDT (24VAC coil)
MFR: 4249736-02
Inventory Details
270 Online Only
via Direct Ship
What's the price?
Sign in or register for pricing.
Add to Cart
On Sale: 10% Off In Cart
PROTECH 43-25136-08 - Capacitor-15/370 Single Round
MFR: 43-25136-08
Inventory Details
0 Pompano Beach #109
83 All Branches
Name
Rheem RH1P3617STANDA - 3 Ton Air Handler, 17"Wide, PSC Motor, Single -Stage Airflow,
Aluminum Evaporator Coil, 480/3/60
(Brand
Rheem
Gemaire Item Number
RH1P3617STANDA
Manufacturer Product
Number
RH1P3617STANDA
SKU - PIM Number
1399041970764
ERP Number
350864
UPC
662021359460
Unit of Measure
EA
Weight
97.0 LB
Length
21.7IN
Width
17.5 IN
Height
42.5IN
Hazardous Material
No
EPA Cert Required
No
Country of Origin
MEX
Equipment Type
Heat Pump
Stage
Single
SEER
15
Refrigerant
R-410a
CFM
1054-1148
Cooling Capacity
18000-24000
Air Flow
Convertible
Voltage
460 VAC
Phase
Three
Cycle/Hertz
60
Minimum Circuit Amps
2
Maximum Fuse Size
15
Blower Motor HP
1/3 HP
Blower Motor RPM
1075
Filter Size
16" x 20"
RPM
1075
Drain Connection Size
3/4"
An-D3� _
kck J-5
ciJ�
View full-size in new tab
Rheem RA1336AD1NB - Classic 3 Ton 13 SEER, Condenser
With High/Low Pressure, 460 Volt, 3 Phase, 60 Hz
Item: RA1336ADlNB MFR: RA1336ADlNB
What's the price?
Sign in or register for pricing.
Quantity'
1
Add to Cart
Your Order Templates
Save products for later, or create lists to quickly re -buy items for routine jobs.
Add to Order Template
J
• Diagnostic service window with two -fastener opening - provides access to the high and low
pressure.
• External gauge port access - allows easy connection of "low -loss" gauge ports
• Single -row condenser coil - makes unit lighter and allows thorough coil cleaning to maintain "out
of the box" performance
• 35% fewer cabinet fasteners and fastener -free base - allow for faster access to internal
components and hassle -free panel removal
• Service trays - hold fasteners or caps during service calls
• OR code - provides technical information on demand for faster service calls
• Fan motor harness with extra long wires allows unit top to be removed without disconnecting fan
wire.
• General Terms Of Limited WarrantyCompressor: Five (5) Years
• Parts: One (1) Year
• Rheem will furnish a replacement for any part of this product which fails in normal use and service
within the applicable period stated, in accordance with the terms of the limited warranty.
Specifications
Name
Rheem RA1336ADlNB - Classic 3 Ton 13 SEER, Condenser With High/Low Pressure, 460 Volt, 3 Phase,
60 Hz
Brand
Rheem
Gemaire Item
Number
RA1336ADlNB
Manufacturer
Product Number
RA1336ADlNB
SKU - PIM Number
1405358021531
ERP Number
( 348811
UPC
N/A
. Unit of Measure
EA
Weight
1143.0 LB
i Length
29.8 IN
Width
29.81N
Height
27.0IN
Hazardous Material
No -
EPA Cert Required
No
Country of Origin
MEX .
Tier
Classic
Equipment Type
Straight Cool
Stage
Single
SEER
13-15.1
EER
11
Refrigerant
R410a
.CFM
2900
Cooling Capacity
36000
Voltage
460 VAC
Full Load Amps
1.3
Phase
Three
Cycle/Hertz
60
Minimum Circuit
Amps
23
Maximum Fuse Size
15
Condenser Motor
HP
1/4 HP
Condenser Motor
Speeds
Variable
Rated Load Amps
16.7
Locked Rotor Amps
83.9
Suction Line Fitting
Sweat
Suction Line Size
3/4"
Liquid Line Fitting
Sweat
Liquid Line Size
3/8"
Certifications
AHRI
Color
Gray
Compressor
(1) Scroll
Inverter
No
Number of Fan
Blades
1 '
Sound Level (dBA)
77.5
Warranty Offered
Rheem will furnish a replacement for any part of this product which fails in normal use and service
within the applicable period stated, in accordance with the terms of the limited warranty. Conditional
Parts (Registration required) Ten Years
Energy Star Rated
Yes
UL Listed
Yes
UL Recognized
No
Fins per Inch
22
Product Family I RA13
Tonnage I3
' GEM -Case
Quantity
Documentation
Use & Care Instructions
Specification Sheet
,t
Installation Instructions
Warranty Document
J}�
Consumer Literature 3
Parts List
PROTECH 42-10266444 - Contactor - 30A 3-Pole (24V coil) w/Auxiliary Contacts
MFR: 42-10266444
Inventory Details
0 Pompano Beach #109
6 All Branches
What's the price?
Sign in or register for pricing.
Add to Cart
Capacitor - 5/370 Single Round
MFR: 43-25136-03
Copeland 45-100834-80 - Molded Plug
MFR: 45-100834-80
Inventory Details
9 Pompano Beach #109
1223 All Branches
What's the price?
Sign in or register for pricing.
—Add-to—Cart—
Snap-in Bushing - Conductor Protection
MFR: 45403252-02