HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online CPage 1 of 2
aI IIL_
1
acts Home Log In User Registration Not Topics Submit Surcharge Stats & Facts Publlc.t ons FFlBCC Staff acts Site Map Links Search
do
err a{� Product Approval SCA m�a�ar--tte r', jj''� r
U-11 �. @�51 USER: Public User B4�Fa7.4i tr — l \.
Pro.ua Approval Meru >PrnauR or Amllation Search> Aoolicat on List> Application Detail St. �uCie Coj% 18 2!3S7
FL ;* FL10674'R12 r ? i .3
Application Type Re son St. Lucie C:OL!li:}. j L
Code Version 2014
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Small
Category
Subcategory
Compliance Method
N
n�wens -cmYng
Comin Parkway
Toledo, OH 43659
(740) 404-7829
greg.keeler@owenscorning.com
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Greg Keeler
greg.keeler@owenscorning.com
Mel Sancrant
1 Owens Corning PKWY
Toledo, OH 43659
(419) 376-8360
mel.sancrant@owenscornig.com
Roofn
Asphalt Shin les
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORAEC i IONS
-REQUIRED BY FIELD INSP[CTORS TH4T
. MAYBE NECESSARY IN ORDE'N1 TO
COMiPLY WITH h ALL APr UCAI E COVES.
ST/LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COMPLIAN1E
°D BY
DATE
MUST BE KEPT ON JbB OR
NO INSPECTION WILL BE MADE
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
CONCEALED FASTENERS OR ATTACHMENTS
Robert J.M. Nieminen ARE THE RESPONSouTY OF THE
PE-591fi6 UL LLC CONTRAOTOROFRECORD
08/20/2017
John W. Knezevich, PE
.r Validation Checklist - Hardcopy Received
pQrP.i�3Y;Ri7i3iII3.II�I�I - a�i .T--LII.T•ll
Standard
year
ASTM D3161
2009
ASTM D3462
2009
ASTM D7158
2008
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V %2... 1 /19/2017
Florida Building Code Online
Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
04/18/2016
04/19/2016
04/20/2016
06/08/2016
FL #
Model, Number or Name
Description
10674.1
Owens Corning Asphalt Roofing
3-tab, 4-tab, 5-tab, laminated, starter and hip & ridge
Shingles and Starters
shingles
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL10674 RIZ 11 2016 04 FINAL ER QC ASPHALT
SHINGLES FL10674-R12.Ddf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert 3. M. Nieminen PE - 59166
Design Pressure: N/A
Created by Independent Third Party: Yes
Other: Refer to ER, Section 5.
Evaluation Reports
EL10674 R12 AE n16 04 FINAL Eft OC ASPHALT
SHINGLES FL10674-R12.odf
Created by Independent Third Party: Yes
Back Next
Contact Us 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Forida :: Prlvacv Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to apublic-records request, do not send
electronic mail to this amity. Instead, contact the once by phone or by traditional mall. If you have any questions, please contact 850.487.1395.'Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a Dersonal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
= ® [[!cY
SCCUIILyA1kTItICS'
i y
*T.: a :,+r�; LA` iF if 7,
r
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V %2... 1 /19/2017
EXTERIOR RESEARCH & DESIGN, LLC.
Certificate of Authorization #9503
TRINJTREET, UNIT #13
N ERD
D 353 CHRISTIAOXFORD, CT 01111
EVALUATION REPORT f F I PHOAX: (203) 262-9243
Owens Corning
One Owens Corning Parkway
Toledo, OH 43659
Evaluation Report 037940.02.12-117
FL10674-R12+ecum
Date of Issuance:02/06/2012
Revision 7: 04/18/2016
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: Owens Corning Asphalt Roof Shingles
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. Trinity[ERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida OCA ANE1983
The facsimile seal appearing was authorhed by Robert Nleminen,
P.E. on 04/18/2016. This does not serve as an electronically signed
dawmenl. Signed, sealed hardcoples have been transmitted to the
P,oductApFreva l Administrator and to the named die nt
CERTIFICATION OF INDEPENDENCE:
1. Trinity[ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products It evaluates, a
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
FILE COPYTRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Asphalt Shingles
Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated
compliance with the following sections of the Florida Building Code and Florida Building Code, Residential Volume
through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements
and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1507.2.5, R905.2.4
Physical Properties
ASTM D3462
2009
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D3161
2009
1507.2.7.1, R905.2.6.1
Wind Resistance
ASTM D7158
2008
3. REFERENCES:
Entity Examination Reference Date
UL LLC (CER9626) Physicals & Wind Resistance File R2453, Vol. 3 02/15/2007
UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012
UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006
UL LLC(TST9628) Wind Resistance IICA34308 02/18/2012
UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014
UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014
UL LLC (TST9628) Physical Properties Classification letter 02/13/2014
UL LLC (TST9628) Physical Properties Classification letter 10/02/2015
Miami -Dade (CER1592) FBC HVHZ Compliance Various NOAs Various
UL LLC (QUA9625) Quality Control Service Confirmation, R2453 Exp. 08/20/2017
4. PRODUCT DESCRIPTION:
4.1 Asphalt Shingles:
4.1.1 Classic d Supreme Ce fiberglass reinforced, 3-tab asphalt roof shingles.
4.1.2 Berkshire erg ass reinforced, 4-tab asphalt roof shingles.
4.1.3 DevonshireT" are fiberglass reinforced, 5-tab asphalt roof shingles.
4.1.4 Duration*, TruDefinition Duration, Duration Premium Cool, TruDefinition Duration Designer Color
Collection, TruDefinition0akridge, Oakridge and WeatherGuard' HP are fiberglass reinforced, laminated
asphalt roof shingles.
4.2 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard* HP Hip & Ridge Shingles, ProEdge Hip & Ridge
Shingles and DuraRidge'" Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles.
4.3 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory
for fire ratings of this product.
Exterior Research and Design, LLC. Evaluation Report 037940.02.12-R7
certificate o/Authorization 99503 FL10674-R12
Revision 7:04/18/2016
Page 2 of 8
711,
FILt
COPY- TRINITY ERp
5.4 Wind Classification:
5.4.1 All Owens Corning shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and
R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for
use in all wind zones up to Va,d = 150 mph (V„ h = 194 mph). Refer to Section 6 for installation requirements
to meet this wind rating.
5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified
in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are
acceptable for use in all wind zones up to Va,d = 150 mph (Vvl, = 194 mph). Refer to Section 6 for installation
requirements to meet this wind rating.
5.4.3 Classification by ASTM D7158 applies to exposure category B or C and a building height of 60 feet or less.
Calculations by a qualified design professional are required for conditions outside these limitations. Contact
the shingle manufacturer for data specific to each shingle.
5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations.
5.5 All products in the roof assembly shall have quality assurance audit in accordance with the Florida Building
Code and F.A.C. Rule 61G20-3.
6. INSTALLATION:
6.1 Underlavment:
6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product
Approval, or be Locally Approved per -Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3.
6.2 Asphalt Shingles:
6.2.1 Installation of asphalt shingles shall comply with the manufacturer's current published instructions, using
minimum four (4) nails per shingle in accordance with FBC Sections 1507.2 or R905.2, with the following
exceptions:
➢ Berkshire shingles require minimum five (5) nails per shingle.
➢ WeatherGuard HP shingles require minimum six (6) nails per shingle.
➢ Devonshire TM shingles require minimum six (6) nails per shingle.
➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip.
Refer to Owens Corning published information on wind resistance and installation limitations.
6.2.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.2.4 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are
required. See figures below for details.
6.2.5 Minimum Nailing —Starter Strip Shingle and Starter Strip Plus:
Felt undenaymem 3 Deck
Self
-adhered
r underlayment
DripDrip edge
edgy —
`Nails located
T-3' hom save
Install first $fit 01 ng adhesive
Starter 6t y passion ed along eave
shinglewith '+..
6' removed Starter Strip shingle overhangs eaves and rakes tf-%'
Exterior Research and Design, U.C.
Certificate of Authorization 99503
Falt undedaymam Ded sdadh.red
unaadarment
Ce
- 0dp cdae
odp—
edge
N.hlautad
2--3-hom eava
Instal erstsu .stri PM Sa[sealin9 adxesive
p pod4aneddons ear.
With 6' removed-----..--y
st.ner snip PWs Overhangs vaea and rakes V.'-LT
Evaluation Report 037940.02.12-R7
FL10674-R32
Revision 7: 04/18/2016
Page 3 of 8
6.2.6 Minimum Nailing — Classic&Su tame:
Normel Menaerd or Aroe pare
Wind Aree• High Wind d•.ven•sy
Area pare vienros norms/es Ane. vianio• Warta•
t 1. (AI r•1• rl• z• IB .rz. 1.
a'E.po.un
F+po.icl6n
6.2.7 Minimum Nailing — Berkshire®:
seahm
-i • •� I • A tee I • r--y
gYY 9Yf 9Yf giY
1' I 1"
Standard Fastening Pattern
TRINITY ERD
Norrnel Mansard or Arse pars
Wind Area. High Wind dem.nea y
A... p.. vienros normale. Are.. vienro. ru."..
Iz 1 (A) s11
s� 1• z' (gl ra' �' ,
6 67b" Exposure
Expo.lcidn
Salem strip
lrib]deselhd.,
a IA" I A Ye" I a th'
1'
6-Nail Fastening Pattern
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R7
Certi/kate of Authorization 89503
FL10674-R32
Revision 7: 04/18/2016
Page 4 of 9
6.2.8 Minimum Nailing—DevonshirelM:
��= 1 7" 1 8"
5-5/8'exposureI Sealant legation
Exposicidn de 5.518 pulg Uhiwcidn del selladar
TRINITY ERD
a•
Nails
Ten t" Spots of Asphalt Roof Cement 1
otanaar0 o-rvan fastening Pattern Mansard or Steep Slope Fastening Pattern
6.2.9 Minimum Nailing — Duration®, TruDefinition® Duration, Duration`9 Premium Cool & TruDefinition• Duration'
-
Designer Color Collection:
4�all Fastening Pattern
SunNa11D 3m3Nne an]MM
r Nai, W-.
1" IS• \\L'' 12• 1•
F1 D F�
F1n• S.yy
Standard Fastening Pattern
6-Nall Fastening Pattern
SwNeiW hsaMne ana MM
NN, lyplul
J 1•
I I
• tiws.`a •atiaic�a� m
6-Nail Fastening Pattern
Fastening rot slope Greater Than 21:11
III/( sx..x.na o.:.nmg a... Mam
1,-
.
41 rt- SpS'e- a
1-Spau m4pnm awMp nrrxnl
Mansard or Steep Slope Fastening Pattern
F.
Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R7
Certificate ofAtnhori2oNon 99563 FL10674-R12
Revision 7: 04/18/2016
Page 5 of 8
FILE COPY
TRINITY
ERD
6.2.1 Minimum Nailing—TruDefinition OakridgeO, Oakridge°:
R
4 Nail Pattern
Esquema con 4 claws
r t•
Ir
55/g"Fxposu re Nags 55lg"Exposure
FrposW6. de 55/Spins, claws Erposisidn de55/8pde.
Standard Fastening Pattern
6 Nail Pattern
Esquema con 6 claws
r r
66/g"Exposure Nails flows 65/8"Exposure�
EeporWa de 6618pulg Erpatiddn de 5518pufg
Fastening for Slopes Greater Than 21:12
•� Su=�NalW lea,aNne.rte MTN
N, hcNn�
Mansard or Steep Slope Fastening Pattern
6.2.1 Minimum Nailing—WeatherGuard®HP:
6-Nail Fastening Pattern
aingle Wtb View
VISE. 1LEu111
Fee" 1 ��f lErn u.
Owtrw4lfewif}db
Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R7
Certificate o/Authorization 99503 Fl-10674-1112
Revision 7: 04/18/2016
Page 6 of 8
FILE
COPY,
6.3 Hip & Ridge Shingles:
6.3.1 Installation of Berkshire* Hip and Ridge Shingles, High Ridge, WeatherGuard' HP Hip and Ridge Shingles and
ProEdge Hip & Ridge Shingles shall comply with the manufacturer's current published instructions, using four
(4) nails per shingle. Installation of DuraRidge'" Hip & Ridge Shingles shall comply with the manufacturer's
current published instructions, using two (2) nails per shingle. Refer to Owens Corning published
information on wind resistance and installation limitations, including the use of hand -sealing for wind
warranties.
6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC
1507.2.6 or R905.2.5. Staples are not permitted.
6.3.3 Minimum Nailing — Berkshire® Hip & Ridge and High Ridge:
Fig. t 4
F PlMlhg was
otreaon a
4 I
I
a I
i
A I 1
{ ♦
r Expose H
Fig. 2
ranw.w suewel
xau N4N
t" [' rPP� lnalm r 1
P.
e P I
r r
i I
I
I
I
gl
�l
1
�l
I
I� _-�
6.3.4 Minimum Nailing — WeatherGuardO HP Hip and Ridge:
Fig. A
PlevaYlnp W.MG
�—Preclbn
Nolla —
A I
\� A
\1
E[pPtula H
Exterior Research and Design, LLC.
Ceru lcate of Authorization 49903
Fig. C Hip & Ridge Shingle Fastening
ropbw
Nalls tlill9
r,.
R" Y"
1' 1'
r• p•
g• Faporvra
Evaluation Report 037940.02.12-R7
F1.10674-1112
Revision 7: 04/18/2016
Page 7 of 8
FIL.a.�,s �' � i' 'OP
6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles:
Prevailing
Wind Direction Sealant Strip
,j*-� 6' Exposure J
7'h'
Standard
Fastening
Pattern
12' 1 Sealant
7 W 6' Expoture
II
6.3.6 Minimum Nailing — DuraRidge'" Hip & Ridge Shingles:
Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning
published installation instructions for their minimum requirements.
Praniing W M 6ira<'
� eineien domiranre d"�me
Oirordanddtiaim prdxnimnn
Rail,— - ?-.-.---'+;-2
t I I I
I
I i i
TnpY
Vu in iran HII- Vu up for I IH
NA
a.o
I
' j, Ovrent Cwrirq SurtHvr _ r"`
I
16
sjEs
a.
V I�pc
7. LABELING:
7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC
Table 1507.2.7.1 / R905.2.6.1.
B. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Contact the named QA entity for information on which plants produce products covered by Florida Rule 9N-3 QA
requirements.
10. QUALITY ASSURANCE ENTITY:
UL LLC—QUA9625; (414) 248-6409; karen.buchmann(@ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, I.I.C.
Certificate of Authorization a9503
Evaluation Report 037940.02.12-R7
F1.10674-1112
Revision 7: 04/18/2016
Page 8 of 8
Florida Building Code Online Page 1 of 2
db
a�r
.
IL_
I-�
ll
ProfessiQnAl—
r
EMS Home I Log T. I User Registration a Hot Tcplce Submit Surcharge 1 State&Facts Publlcatianp I FEC Stall p£IS Site. MjR Links Search
�. Product Approval
USER: Public User
Protud Approval Menu > ProdProdya or Applicationscand > Aoogcatlon List> Appnestion Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL16048-R4
2014
Approved
X
Tri-Built Materials Group, LLC
_ _ SY S
Rutherford, NJ 07070
(800) 516-1485
david.ruiz@tribuiltmg.com
JUL ; s 2g��
PER ,7117iidG
St. Lucie CDun4,, FL
SCANNED
BY
St. LUcie
County
THESE PLANS AND ALL PROPOSED WORK
David Ruiz ARE SUBJECT TO ANY COPMECTIONS
david.ruiz@tribulltmg.com ' REQUIRED BY FIELD INSPECTORS THAT
David Ruiz MAY BE NECESSARY IN ORD2R TO
East Rutherford, Route 17 North
07073 CCit u'M WITH ALL MPL1CABLE CCrDEG.
(201) 842-2449
david.ruiz@tribuiltmater'ialsgroup.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
n Evaluation Report - Hardcopy Received
Robert Nleminen
PE-59166
UL LLC
10/16/2017
John W. Knezevich, PE
M Validation Checklist - Hardcopy Received
FL16048 R4 COI 2016 91 COT Nieminen.ndf
Standard
year
ASTM D1970
2009
ASTM G155
2005
FRSA/TRI April 2012 (04-12)
2012
TAS 103
1995
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtFPmdYiND Wr... 6/23/2017
Florida Building Code Online Page 2 of 2
1
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products r
i
Method 1 Option D FILE
10/06/2016 AAL
10/1/2016 ��
10/19/2016
12/13/2016
06/12/2017
FL #
Model, Number or Name
Description
16048.1
TRI-BUILT Roof Underlayments
Self -adhering, modified bitumen roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
EL16048 R4 II 2016 SO FINAL ER TRI-
Approved for use outside HVHZ: Yes
BUILT UNDERLAYMENT FL36046-R4 df
Impact Resistant: N/A
Verified By: Robert Nleminen PE-59166
Design Pressure: +N/A/-67.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use
Evaluation Reports
of foam -on tile systems overtop the self -adhering
FL16048 R4 AE 2016 10 FINAI ER TRI
underlayment for one particular application. See ER Section
BUILT UNDERL6YMENT5 FL36048-R4 df
5.6.4 for details. 2.) Refer to ER Section 5 for other Limits of
Created by Independent Third Party: Yes
Use.
Back Fert
Contact Op3:; 2601 Blar Sion Road, I h ' phone: 850-487-1924
The state of Hard.A( lis on AEEO employee Caovrloht 2007-20 3 f Florida. FL
Statement :: A<ressibillty Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mall to Nis entity. Instead, contact the office by phone or by traditional mail. if you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Rance Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The Smalls pmvided may be used For oRcial communication with Me licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can bS made available to the public. To determine If you are a licensee under
Chapter ass, F.s., please cock Pere .
Product Approval Accepts:
Credit Card
Safe
http://www. floridabuilding.org/prlpr_app_dtl.aspx?param=wGEV XQ WtDgtFPmdYiND Wr... 6/23/2017
�INITYI ERD
EVALUATION
Allied Building Products Corp.
dba TRI-BUILT Roofing Products
9050 Louisiana Street
Merrillville, IN 46410
EXTERIOR RESEARCH & DESIGN,LLC.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
Evaluation Report A42960.10.12-R4
FL16048-R4 '=n
Date of Issuance:10/25/2012
Revision 4: 10/06/2016
SCOPE:
This Evaluation Report is issued under Rule 51G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the Su, Edition (2014) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity) ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 5
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The Iacslmile seal appearing was authorized by Robert Nieminen,
P.E. on 10/06/2016. This does not serve as an eledron callysigned
document. 519ned, sealed hardtop],, have been transmitted to the
Product Approval Administrator sod to the named dent
CERTIFICATION OF INDEPENDENCE:
1. Trinityl ERD does not have, nor does it Intend to acquire or will it acquire, a financial interest In any company manufacturing or
distributing products It evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have,.nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
�j TRINrry ERD
ROOFING COMPONENT EVALUATION:
1. COPE: FILE
Product Category: Roofing
Sub{ategory: Underlayment
Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section Property Standard Year
1507.2.4, 1507.2.8, 1507.2.9.2, Physical Properties ASTM D1970 2009
1507.4.5.1, 1507.5.3, 1S07.7.3
1504.6 Accelerated Weathering ASTM G155 2005
1507.3.3 Installation Practice FRSA/TRI April 2012 (04-12) 2012
1523.6.5.2.1 Physical Properties TAS 103 1995
3. REFERENCES:
Entity Examination Reference Date
ERD (TST6049) Physical Properties 540540.02.13-1 02/19/2013
ERD (TST6049) Physical Properties 540540.11.13 11/19/2013
ERD (TST6049) Physical Properties 540540.03.14 03/26/2014
ERD (TST6049) Physical Properties 544870.04.14-2 04/02/2014
ERD (TST6049) Physical Properties 544870.04.14-3 04/02/2014
ERD (TST6049) Physical Properties 544870.04.14-1 04/10/2014
ERD (TST6049) Physical Properties 544870.04.14-4 04/10/2014
ERD (TST6049) Physical Properties 543530.02.14-1-R1 05/14/2014
ERD (TST6049) Physical Properties 543530.05.14 05/28/2014
ERD (TST6049) Physical Properties 540540.10.14 10/31/2014
ERD (TST6049) Physical Properties SC7645.02.15 02/13/2015
ERD (TST6049) Accelerated Weathering SC8520.04.15 05/27/2015
UL, LLC. (QUA9625) Quality Control Multiple -Listing R16814 09/04/2015
UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 10/16/2017
4. PRODUCT DESCRIPTION:
4.1 Self -Adhering Underlayments:
4.1.1 `Sii-BLn t,3 an A';'Sh ng e�Underlayment-is +self -adhering, glass -mat reinforced, sand -surfaced, SBS
modifiedrMUmMoo` rrideria rhifii, 4wrtfi a 36-inch sheet width.
4.1.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof underlayment
4.1.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS
modified bitumen roof underlayment.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R4
reniJkate of AuthaHzatlon#9503 FBC NON-HVHZ EVALUATION FL16048-R4
Revision 4: 10/06/2016
Page 2 of 5
FILE -COPY
\I TRINITY ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the AHJ for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable roof covers applied atop the underlavments are as follows:
TABLE 1: ROOF COVER OPTIONS
Underlayment
Asphalt
Shingles
Nail -On Tile
Foam-OnTile
Metal
Wood Shakes
Slate
& Shingles
Tri-Built Sand-R SA Shingle
Underlayment
Yes
No
No
No
Yes
Yes
Tri-Built 5/A HT TU
Yes
Underlayment
Yes
Yes
See 5.5.1
Yes
Yes
Yes
Tri-Built Smooth HTS/A
Underlayment
Yes
No
No
Yes
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long
term aging data from an accredited testing laboratory is provided.
D Tri-Built S/A HT TU Underlayment with 3M'" 2-Component Roof Tile Adhesive AH-160 (FL6332) or
Dow TileBoncl Roof Tile Adhesive (FL717)
5.6 Allowable substrates are noted below:
5.6.1 Direct -Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
D Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT recommends
priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT
requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the
self -adhering underlayment.
5.6.2 Bond -to -Insulation:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations
under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D or TAS 114, Appendix J.
5.6.3 Bond to Mechanically Attached Base Laver:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226, Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam=on tile systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12).
Exterior Research and Design, U.C. Evaluation Report A42960.10.12-114
CeWJkate ofA.th0d t1on #9503 FBC NON-HVHZ EVALUATION FL16048-R4
Revision 4:10/06/2016
Page 3 of 5
f.1
5.6.4 Wind Resistance for Underlayment Systems in Foam On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems that are not addressed in FRSA/TRIApril 2012 (04-12) and are used in foam -on tile
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind pressures.
5.6.4.1 Maximum Design Pressure = -45 0 psf.
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of AHJ.
Primer: (Optional) ASTM D41
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
5.6.4.2 Maximum Design Pressure =-67 5 psf.
Deck: Structural concrete to meet project requirements to satisfaction of AHJ.
- Primer: Soprema Elastocol 600c
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
5.6.4.3 Maximum Design Pressure =-60 0 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of AHJ.
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered.
5.7 Exposure Limitations:
5.7.1 Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
5.7.2 Tri-Built S/A HTTU Underlayment shall not be left exposed for longer than 180-days after installation.
INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT published installation
requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Tri-Built Sand-R SA Shingle Underlayment Tri-Built S/A HT TU Underlayment or Tri Built Smooth HT S/A
Underlayment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
While priming is optional, TRI-BUILT recommends priming the deck if the final roof cover is not slated for
installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT requirements.
Exterior Research and Design, LLG Evaluation Report A42960.10.12-R4
CertlJ![ote oJAuthortrotlon #9503 FRC NON-HVHZ EVALUATION FL16D48.R4
Revision 4: 10/06/2016
Page 4 of 5
7.
8.
9.
When installing at slopes above 8:12,
the sheet at 12-inch o.c.
TRINITY f ERD
TRI-BUILT recommends back -nailing in the overlap area at the top of
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward.
6.3.3 Tile Applications fTri-Built S/A HT TU Underlavment only):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
MANUFACTURING PLANTS:
Contact the noted CIA agency for information on product locations covered for F.A.C. Rule 9N-3 CIA requirements.
QUALITY ASSURANCE ENTITY:
UL, LLC— QUA9625; (314) 578-3406; k.chancellor@us.ul.com
END OF EVALUATION REPORT-
Exterior Research and Design, I.I.C.
Certxfioate of Authatlmtlon#9503 FBC NON-HVHZ EVALUATION
-sI
a )a i9w1@ "S,. "N 5
yy �; N . �i a�f�'
Evaluation Report A42960.10.12-R4
FL16048-R4
Revision 4: 10/D6/2016
Page 5 of 5